Valeria Ottaviani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Valeria Ottaviani has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Raffaele Lorenzo Dellacà
Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
3 shared publications - Chiara Veneroni
Politecnico di Milano, Department of Electronics, Information and Bioengineering, Milano (MI), Italy
2 shared publications Fabio Mosca
NICU, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy
2 shared publicationsAnna Lavizzari
NICU, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy
1 shared publication- Anna Lavizzari
Neonatal Intensive Care Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
1 shared publication - Daniele De Luca
Division of Pediatrics and Neonatal Critical Care, “A. Béclère” Medical Center, Paris Saclay University Hospital, APHP – Paris, Clamart, France
1 shared publication
Latest Publications
- Open Access
- 21 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 10, 1-8
Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study
Objective: Monitoring infants’ breathing activity is crucial in research and clinical applications but remains a challenge. This study aims to develop a contactless method to monitor breathing patterns and thoracoabdominal asynchronies in infants inside the incubator, using depth cameras. Methods: We proposed an algorithm to extract the 3D displacements of the ribcage and abdomen from the analysis of depth images. We evaluated the accuracy of the system in-vitro vs. a reference motion capture analyzer. We also conducted a feasibility study on 12 patients receiving non-invasive respiratory support to estimate the mean and the variability of the chest wall displacements in preterm infants and evaluate the suitability of the proposed system in the clinical setting. Results: In-vitro, the mean (95% CI) error in the measurement of amplitude, frequency and phase shift between compartmental displacements was -0.14 (-0.57, 0.28) mm, 0.02 (-0.99, 1.03) bpm, and -0.40 (-1.76, 0.95)°, respectively. In-vivo, the mean (95% CI) amplitude of the ribcage and abdomen displacements were 0.99 (0.34, 2.67) mm and 1.20 (0.40, 2.15) mm, respectively. Conclusions: The developed system proved accurate in-vitro and was suitable for the clinical environment. Clinical Impact: The proposed method has value for evaluating infants’ breathing patterns in research applications and, after further development, may represent a simple monitoring tool for infants’ respiratory activity inside the incubator.
- 21 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 10, 1-8
Open AccessContactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study
Objective: Monitoring infants’ breathing activity is crucial in research and clinical applications but remains a challenge. This study aims to develop a contactless method to monitor breathing patterns and thoracoabdominal asynchronies in infants inside the incubator, using depth cameras. Methods: We proposed an algorithm to extract the 3D displacements of the ribcage and abdomen from the analysis of depth images. We evaluated the accuracy of the system in-vitro vs. a reference motion capture analyzer. We also conducted a feasibility study on 12 patients receiving non-invasive respiratory support to estimate the mean and the variability of the chest wall displacements in preterm infants and evaluate the suitability of the proposed system in the clinical setting. Results: In-vitro, the mean (95% CI) error in the measurement of amplitude, frequency and phase shift between compartmental displacements was -0.14 (-0.57, 0.28) mm, 0.02 (-0.99, 1.03) bpm, and -0.40 (-1.76, 0.95)°, respectively. In-vivo, the mean (95% CI) amplitude of the ribcage and abdomen displacements were 0.99 (0.34, 2.67) mm and 1.20 (0.40, 2.15) mm, respectively. Conclusions: The developed system proved accurate in-vitro and was suitable for the clinical environment. Clinical Impact: The proposed method has value for evaluating infants’ breathing patterns in research applications and, after further development, may represent a simple monitoring tool for infants’ respiratory activity inside the incubator.
- 26 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 144, 105352
Simultaneous monitoring of vocal doses and breathing patterns in professional singers
- 26 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 144, 105352
Simultaneous monitoring of vocal doses and breathing patterns in professional singers
- 27 May 2020
- Published by Wiley in Pediatric Pulmonology
- Vol. 55 (8) , 1955-1962
Accuracy of volume and pressure delivery by mechanical ventilators in use in neonatal intensive care units: A quality control study
Objective: Despite technical specifications of neonatal mechanical ventilators (MVs) guarantee clinically irrelevant discrepancies between the set and the delivered values of ventilation parameters, previous studies reported large deviations. Most studies characterized performances of a given model/brand by studying a single device, disregarding possible intramodel differences, and leaving the accuracy of the ventilation parameters effectively delivered in clinical settings unknown. The aim of this study was to evaluate the real‐life accuracy of pressure and volume parameters delivered by neonatal ventilators ready to be used on patients in neonatal intensive care units (NICUs).Study Design: In vitro study.Subjects Selection: Neonatal ventilators (n = 33 of 8 different models) available in four European NICUs.Methodology: The MVs were connected to a test lung (resistance = 50 cmH2O*s/L, compliance = 0.35 mL/cmH2O) provided with pressure and flow sensors. MVs were tested over two different ventilation modes randomly: (a) pressure controlled (PC) with a peak inspiratory pressure (PIP) of 22 cmH2O, and (b) PC with volume targeted ventilation (VTV) with a tidal volume (VT) of 6 mL. In all tests, positive end‐expiratory pressure (PEEP) was set to 6 cmH2O, respiratory rate to 45 breaths/min, inspiratory time to 0.33 seconds, and oxygen fraction to 0.3.Results: During PC the median (min‐max) values delivered were: PEEP = 5.84(4.95‐6.48) cmH2O, PIP = 21.63(20.04‐22.62) cmH2O. During VTV, VT was 5.94(4.63‐8.01) mL. VT was considerably variable, ranging from −22% to +33% of the set and displayed values. Differences in accuracy among devices of the same model were comparable to those found among different models.Conclusions: Our findings suggest that loss of accuracy in ventilation variables is likely related to daily use of the devices rather than weakness in the design or manufacturing process, urging the improvement of maintenance and quality control procedures to preserve the performances of neonatal MVs during their entire lifespan.
- 27 May 2020
- Published by Wiley in Pediatric Pulmonology
- Vol. 55 (8) , 1955-1962
Accuracy of volume and pressure delivery by mechanical ventilators in use in neonatal intensive care units: A quality control study
Objective: Despite technical specifications of neonatal mechanical ventilators (MVs) guarantee clinically irrelevant discrepancies between the set and the delivered values of ventilation parameters, previous studies reported large deviations. Most studies characterized performances of a given model/brand by studying a single device, disregarding possible intramodel differences, and leaving the accuracy of the ventilation parameters effectively delivered in clinical settings unknown. The aim of this study was to evaluate the real‐life accuracy of pressure and volume parameters delivered by neonatal ventilators ready to be used on patients in neonatal intensive care units (NICUs).Study Design: In vitro study.Subjects Selection: Neonatal ventilators (n = 33 of 8 different models) available in four European NICUs.Methodology: The MVs were connected to a test lung (resistance = 50 cmH2O*s/L, compliance = 0.35 mL/cmH2O) provided with pressure and flow sensors. MVs were tested over two different ventilation modes randomly: (a) pressure controlled (PC) with a peak inspiratory pressure (PIP) of 22 cmH2O, and (b) PC with volume targeted ventilation (VTV) with a tidal volume (VT) of 6 mL. In all tests, positive end‐expiratory pressure (PEEP) was set to 6 cmH2O, respiratory rate to 45 breaths/min, inspiratory time to 0.33 seconds, and oxygen fraction to 0.3.Results: During PC the median (min‐max) values delivered were: PEEP = 5.84(4.95‐6.48) cmH2O, PIP = 21.63(20.04‐22.62) cmH2O. During VTV, VT was 5.94(4.63‐8.01) mL. VT was considerably variable, ranging from −22% to +33% of the set and displayed values. Differences in accuracy among devices of the same model were comparable to those found among different models.Conclusions: Our findings suggest that loss of accuracy in ventilation variables is likely related to daily use of the devices rather than weakness in the design or manufacturing process, urging the improvement of maintenance and quality control procedures to preserve the performances of neonatal MVs during their entire lifespan.