Felix Burkhardt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Felix Burkhardt has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Benedikt Christopher Spies
Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
21 shared publications - Ralf-Joachim Kohal
Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, 79106 Freiburg, Germany
9 shared publications - Kirstin Vach
Center for Data Science, Eberswalde University for Sustainable Development, Schicklerstr. 5, 16225 Eberswalde, Germany
8 shared publications - Christian Wesemann
Department of Orthodontics, Justus Liebig University Giessen, Schlangenzahl 14, Giessen, 35392, Germany
5 shared publications Kirstin Vach
Medical Center – University of Freiburg Institute of Medical Biometry and Statistics Freiburg Germany
5 shared publications- Stefano Pieralli
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
4 shared publications
Latest Publications
- Open Access
- 24 October 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 177
Clinical evaluation of 3D-printed stabilization splints for probable bruxism: An exploratory cohort analysis of a randomized prospective single-blinded crossover trial
- 24 October 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 177
Open AccessClinical evaluation of 3D-printed stabilization splints for probable bruxism: An exploratory cohort analysis of a randomized prospective single-blinded crossover trial
- Open Access
- 25 September 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 176
Digitization of a single tissue-level implant without scan body – a feasibility study
- 25 September 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 176
Open AccessDigitization of a single tissue-level implant without scan body – a feasibility study
- Open Access
- 3 June 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 173, 106810
Feasibility of digitizing multiple tissue-level implants without scan bodies for fixed dental prostheses
- 3 June 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 173, 106810
Open AccessFeasibility of digitizing multiple tissue-level implants without scan bodies for fixed dental prostheses
- Open Access
- 5 May 2026
- Published by Wiley in Macromolecular Materials and Engineering
- Vol. 311 (5) , e70226
Self‐Texturing Scratch‐Resistant and Bacteria‐Repellent Superhydrophobic Polypropylene Surfaces Through Extrusion‐Based Additive Manufacturing
Superhydrophobic surfaces with hierarchical nano‐ and micro‐structures are of immense importance for applications in highly frequented public spaces due to their self‐cleaning and germ‐repellent properties. Additive manufacturing enables creating such bioinspired multifunctional textures by digital design in just one 3D printing step. However, fused filament fabrication (FFF), also known as fused deposition modeling (FDM), is strictly limited to microstructure formation due to its comparatively low resolution. Herein, we overcome this limitation by exploiting in‐situ surface nanostructure formation via self‐assembly of innocuous behenic acid (BA) which was melt‐blended with glass fiber‐reinforced nanophase‐separated polypropylene (PP) reactor blends to produce superhydrophobic, scratch‐resistant and self‐healing PP surfaces. The digitized 3D printing process controls the formation of the PP microstructures and the BA nanocrystals on the PP surface, rendering the PP superhydrophobic. Moreover, the continuous migration and nanostructure formation of behenic acid enables self‐regeneration assuring durability of superhydrophobicity even after cleaning using surfactants. Microscopic surface imaging along with the measurement of contact angles (163°) and roll‐off angles (12°) confirm the superhydrophobic properties. Mechanical analyses and scratch tests demonstrate the outstanding robustness of these self‐texturing PP surfaces. According to adherence tests with salivary bacteria, the reduction in initial bacterial adhesion was found to be 87%.
- 5 May 2026
- Published by Wiley in Macromolecular Materials and Engineering
- Vol. 311 (5) , e70226
Open AccessSelf‐Texturing Scratch‐Resistant and Bacteria‐Repellent Superhydrophobic Polypropylene Surfaces Through Extrusion‐Based Additive Manufacturing
Superhydrophobic surfaces with hierarchical nano‐ and micro‐structures are of immense importance for applications in highly frequented public spaces due to their self‐cleaning and germ‐repellent properties. Additive manufacturing enables creating such bioinspired multifunctional textures by digital design in just one 3D printing step. However, fused filament fabrication (FFF), also known as fused deposition modeling (FDM), is strictly limited to microstructure formation due to its comparatively low resolution. Herein, we overcome this limitation by exploiting in‐situ surface nanostructure formation via self‐assembly of innocuous behenic acid (BA) which was melt‐blended with glass fiber‐reinforced nanophase‐separated polypropylene (PP) reactor blends to produce superhydrophobic, scratch‐resistant and self‐healing PP surfaces. The digitized 3D printing process controls the formation of the PP microstructures and the BA nanocrystals on the PP surface, rendering the PP superhydrophobic. Moreover, the continuous migration and nanostructure formation of behenic acid enables self‐regeneration assuring durability of superhydrophobicity even after cleaning using surfactants. Microscopic surface imaging along with the measurement of contact angles (163°) and roll‐off angles (12°) confirm the superhydrophobic properties. Mechanical analyses and scratch tests demonstrate the outstanding robustness of these self‐texturing PP surfaces. According to adherence tests with salivary bacteria, the reduction in initial bacterial adhesion was found to be 87%.
- Open Access
- 2 October 2025
- Published by Wiley in Clinical Oral Implants Research
- Vol. 37 (1) , 33-44
Ten‐Year Results of a Prospective Study on One‐Piece Zirconia Oral Implants for Single‐Tooth Reconstruction
Objectives: The intention of this 10‐year prospective cohort investigation was to clinically and radiographically investigate the outcomes of a one‐piece zirconia implant system for single‐tooth replacement. Materials and Methods: A total of 65 patients received 66 single‐tooth implants restored with all‐ceramic crowns. Follow‐up assessments were conducted at the time of prosthetic delivery, after 1, 3, 5, and 10 years. Peri‐implant soft tissue parameters were evaluated. To assess peri‐implant bone loss, standardized radiographs were taken at implant placement, prosthetic delivery, at the 1‐, 3‐, 5‐, and 10‐year follow‐ups. Statistical analysis was conducted using linear mixed regression models and Wilcoxon Signed Rank tests to compare differences over time and between groups ( p < 0.05). Results: Over the course of 10 years, 16 implants were lost, yielding a cumulative survival rate of 73.3%. Fifteen patients were lost to follow‐up over the 10‐year period. The average marginal bone loss of the remaining implants was 1.09 mm. Probing depth, attachment level, and bleeding showed an increase over time, while plaque index slightly decreased. Conclusions: Given the high implant loss rate after 10 years and the high occurrence of advanced bone loss observed in this study, the implant was not recommended for routine clinical use.
- 2 October 2025
- Published by Wiley in Clinical Oral Implants Research
- Vol. 37 (1) , 33-44
Open AccessTen‐Year Results of a Prospective Study on One‐Piece Zirconia Oral Implants for Single‐Tooth Reconstruction
Objectives: The intention of this 10‐year prospective cohort investigation was to clinically and radiographically investigate the outcomes of a one‐piece zirconia implant system for single‐tooth replacement. Materials and Methods: A total of 65 patients received 66 single‐tooth implants restored with all‐ceramic crowns. Follow‐up assessments were conducted at the time of prosthetic delivery, after 1, 3, 5, and 10 years. Peri‐implant soft tissue parameters were evaluated. To assess peri‐implant bone loss, standardized radiographs were taken at implant placement, prosthetic delivery, at the 1‐, 3‐, 5‐, and 10‐year follow‐ups. Statistical analysis was conducted using linear mixed regression models and Wilcoxon Signed Rank tests to compare differences over time and between groups ( p < 0.05). Results: Over the course of 10 years, 16 implants were lost, yielding a cumulative survival rate of 73.3%. Fifteen patients were lost to follow‐up over the 10‐year period. The average marginal bone loss of the remaining implants was 1.09 mm. Probing depth, attachment level, and bleeding showed an increase over time, while plaque index slightly decreased. Conclusions: Given the high implant loss rate after 10 years and the high occurrence of advanced bone loss observed in this study, the implant was not recommended for routine clinical use.
- Open Access
- 13 June 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 160, 105911
One-piece zirconia oral implants supporting three-unit fixed dental prostheses: Ten-year results from a prospective case series
- 13 June 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 160, 105911
Open AccessOne-piece zirconia oral implants supporting three-unit fixed dental prostheses: Ten-year results from a prospective case series
- Open Access
- 27 January 2025
- Published by Wiley in Clinical Oral Implants Research
- Vol. 36 (5) , 589-599
Five‐Year Results of One‐Piece Zirconia Oral Implants Supporting Three‐Unit Fixed Dental Prostheses
Objectives: The purpose of the present prospective case series was to investigate the clinical and radiological outcome of one‐piece zirconia implants fabricated from 3Y‐TZP with a moderately roughened endosseous surface (Sa = 1.24 μm) to support three‐unit fixed dental prostheses (FDP) after five years in function.Materials and Methods: Twenty‐seven patients received a total of 54 implants in a one‐stage surgery with immediate provisionalization. Peri‐implant bone loss was assessed using standardized radiographs. Additionally, soft‐tissue parameters were analyzed. Statistical analyses were conducted using linear mixed regression models and Wilcoxon Signed Rank tests (p < 0.05). All patients participated in an annual maintenance program.Results: Eighteen implants were lost up to the 5‐year follow‐up, resulting in a cumulative survival rate of 66.67%. The mean marginal bone loss of the remaining implants amounted to 1.89 mm. Probing depth, clinical attachment loss, and bleeding on probing increased from prosthesis insertion to the 5‐year follow‐up, while the plaque index showed no significant changes during the same period.Conclusions: The investigated one‐piece zirconia implant showed low survival rates as compared to previously reported survival rates of one‐piece zirconia or two‐piece titanium implants. Implant failure was attributed to peri‐implantitis, leading to the necessity of implant removal. The implant is not commercially available.
- 27 January 2025
- Published by Wiley in Clinical Oral Implants Research
- Vol. 36 (5) , 589-599
Open AccessFive‐Year Results of One‐Piece Zirconia Oral Implants Supporting Three‐Unit Fixed Dental Prostheses
Objectives: The purpose of the present prospective case series was to investigate the clinical and radiological outcome of one‐piece zirconia implants fabricated from 3Y‐TZP with a moderately roughened endosseous surface (Sa = 1.24 μm) to support three‐unit fixed dental prostheses (FDP) after five years in function.Materials and Methods: Twenty‐seven patients received a total of 54 implants in a one‐stage surgery with immediate provisionalization. Peri‐implant bone loss was assessed using standardized radiographs. Additionally, soft‐tissue parameters were analyzed. Statistical analyses were conducted using linear mixed regression models and Wilcoxon Signed Rank tests (p < 0.05). All patients participated in an annual maintenance program.Results: Eighteen implants were lost up to the 5‐year follow‐up, resulting in a cumulative survival rate of 66.67%. The mean marginal bone loss of the remaining implants amounted to 1.89 mm. Probing depth, clinical attachment loss, and bleeding on probing increased from prosthesis insertion to the 5‐year follow‐up, while the plaque index showed no significant changes during the same period.Conclusions: The investigated one‐piece zirconia implant showed low survival rates as compared to previously reported survival rates of one‐piece zirconia or two‐piece titanium implants. Implant failure was attributed to peri‐implantitis, leading to the necessity of implant removal. The implant is not commercially available.
- Top Cited PapersOpen Access
- 4 January 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 153, 105559
Accuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study
- 4 January 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 153, 105559
Top Cited PapersOpen AccessAccuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study
- 16 October 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 151, 105410
Feasibility of using two generative AI models for teeth reconstruction
- 16 October 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 151, 105410
Feasibility of using two generative AI models for teeth reconstruction
- Open Access
- 13 March 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 153, 106507
Dimensional accuracy and simulation-based optimization of polyolefins and biocopolyesters for extrusion-based additive manufacturing and steam sterilization.
- 13 March 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 153, 106507
Open AccessDimensional accuracy and simulation-based optimization of polyolefins and biocopolyesters for extrusion-based additive manufacturing and steam sterilization.