Nazan Puluca

Nazan Puluca

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nazan Puluca has a total of 70 co-authors. Here are the top co-authors by number of shared publications:

  • Sean M. Wu

    Stanford Cardiovascular Institute, Stanford University School of Medicine, Stanford, CA 94305

    3 shared publications
  • Markus Krane

    Department of Cardiovascular Surgery, Institute Insure, German Heart Center Munich, School of Medicine & Health, Technical University of Munich, Lazarettstrasse 36, 80636 Munich, Germany

    2 shared publications
  • Martina Dreßen

    Department of Cardiovascular Surgery, Institute Insure, TUM University Hospital German Heart Center, School of Medicine and Health, Technical University of Munich , Lazarettstraße 36, D-80636 Munich

    2 shared publications
  • Rüdiger Lange

    Department of Cardiovascular Surgery, German Heart Center Munich, Technische Universität München, Germany

    2 shared publications
  • Stefanie A. Doppler

    Department of Cardiovascular Surgery, Institute Insure, TUM University Hospital German Heart Center, School of Medicine and Health, Technical University of Munich , Lazarettstraße 36, D-80636 Munich

    2 shared publications
  • Alessandra Moretti

    First Department of Medicine, Cardiology, Klinikum Rechts der Isar Technical University of Munich Munich Germany

    1 shared publication

Latest Publications

  • Open Access

    In vivo visualization and molecular targeting of the cardiac conduction system

    by William R. Goodyer, Benjamin M. Beyersdorf, Lauren Duan, Nynke S. van Den Berg, Sruthi Mantri, Francisco X. Galdos, Nazan Puluca, Jan W. Buikema, Soah Lee, Darren Salmi, et al.

    Accidental injury to the cardiac conduction system (CCS), a network of specialized cells embedded within the heart and indistinguishable from the surrounding heart muscle tissue, is a major complication in cardiac surgeries. Here, we addressed this unmet need by engineering targeted antibody-dye conjugates directed against the CCS, allowing for the visualization of the CCS in vivo following a single intravenous injection in mice. These optical imaging tools showed high sensitivity, specificity, and resolution, with no adverse effects on CCS function. Further, with the goal of creating a viable prototype for human use, we generated a fully human monoclonal Fab that similarly targets the CCS with high specificity. We demonstrate that, when conjugated to an alternative cargo, this Fab can also be used to modulate CCS biology in vivo, providing a proof of principle for targeted cardiac therapeutics. Finally, in performing differential gene expression analyses of the entire murine CCS at single-cell resolution, we uncovered and validated a suite of additional cell surface markers that can be used to molecularly target the distinct subcomponents of the CCS, each prone to distinct life-threatening arrhythmias. These findings lay the foundation for translational approaches targeting the CCS for visualization and therapy in cardiothoracic surgery, cardiac imaging, and arrhythmia management.


  • Open Access

    Sequential Defects in Cardiac Lineage Commitment and Maturation Cause Hypoplastic Left Heart Syndrome

    by Markus Krane, Martina Dreßen, Gianluca Santamaria, Ilaria My, Christine M. Schneider, Tatjana Dorn, Svenja Laue, Elisa Mastantuono, Riccardo Berutti, Hilansi Rawat, et al.

    Background: Complex molecular programs in specific cell lineages govern human heart development. Hypoplastic left heart syndrome (HLHS) is the most common and severe manifestation within the spectrum of left ventricular outflow tract obstruction defects occurring in association with ventricular hypoplasia. The pathogenesis of HLHS is unknown, but hemodynamic disturbances are assumed to play a prominent role. Methods: To identify perturbations in gene programs controlling ventricular muscle lineage development in HLHS, we performed whole-exome sequencing of 87 HLHS parent–offspring trios, nuclear transcriptomics of cardiomyocytes from ventricles of 4 patients with HLHS and 15 controls at different stages of heart development, single cell RNA sequencing, and 3D modeling in induced pluripotent stem cells from 3 patients with HLHS and 3 controls. Results: Gene set enrichment and protein network analyses of damaging de novo mutations and dysregulated genes from ventricles of patients with HLHS suggested alterations in specific gene programs and cellular processes critical during fetal ventricular cardiogenesis, including cell cycle and cardiomyocyte maturation. Single-cell and 3D modeling with induced pluripotent stem cells demonstrated intrinsic defects in the cell cycle/unfolded protein response/autophagy hub resulting in disrupted differentiation of early cardiac progenitor lineages leading to defective cardiomyocyte subtype differentiation/maturation in HLHS. Premature cell cycle exit of ventricular cardiomyocytes from patients with HLHS prevented normal tissue responses to developmental signals for growth, leading to multinucleation/polyploidy, accumulation of DNA damage, and exacerbated apoptosis, all potential drivers of left ventricular hypoplasia in absence of hemodynamic cues. Conclusions: Our results highlight that despite genetic heterogeneity in HLHS, many mutations converge on sequential cellular processes primarily driving cardiac myogenesis, suggesting novel therapeutic approaches.


  • Open Access

    In vitro comparison of everting vs. non-everting suture techniques for the implantation of a supra-annular biological heart valve

    by Nazan Puluca, Andrea Münsterer, Anatol Prinzing, Zachary A. Sexton, Rüdiger Lange, Roza Meyer-Saraei, Michael Scharfschwerdt

    Background: The aim of this study was to evaluate the hemodynamic effect of different suturing techniques for aortic valve replacement (AVR) in vitro. Whether or not the applied suturing technique impacts the outflow tract diameter by narrowing the annulus diameter was examined. Methods: The commonly applied non-everting pledget forced suture technique (NE, n=13) was compared with an everting pledget forced suture (ET, n=13) for AVR using the 25 mm St. Jude Trifecta aortic valve. Hemodynamic parameters were obtained in a pulsatile flow simulator. A high speed camera captured the visual aspects of the suturing technique. Results: Despite some kind of left ventricular outflow narrowing due to protruding pledgets using the NE suture technique, mean pressure gradients of both techniques were nearly similar (NE 5.88±2.7 mmHg, ET 5.23±1.31 mmHg, P=0.44). Closing volume (NE 3.16±0.48 mL; ET 3.51±0.68 mL; P=0.14) and the leakage volume (NE: 8.09±2.53 mL; ET: 8.35±3.65 mL; P=0.83) also showed no differences. Conclusions: AVR using either suturing techniques leads to a similar hemodynamic performance in vitro. The impact of the suturing technique may be higher in a smaller annulus. Therefore, further studies using smaller prostheses are necessary.


  • Bioprinting Approaches to Engineering Vascularized 3D Cardiac Tissues

    by Nazan Puluca, Soah Lee, Stefanie Doppler, Andrea Münsterer, Martina Dreßen, Markus Krane, Sean M. Wu

    Purpose of Review 3D bioprinting technologies hold significant promise for the generation of engineered cardiac tissue and translational applications in medicine. To generate a clinically relevant sized tissue, the provisioning of a perfusable vascular network that provides nutrients to cells in the tissue is a major challenge. This review summarizes the recent vascularization strategies for engineering 3D cardiac tissues. Recent Findings Considerable steps towards the generation of macroscopic sizes for engineered cardiac tissue with efficient vascular networks have been made within the past few years. Achieving a compact tissue with enough cardiomyocytes to provide functionality remains a challenging task. Achieving perfusion in engineered constructs with media that contain oxygen and nutrients at a clinically relevant tissue sizes remains the next frontier in tissue engineering. Summary The provisioning of a functional vasculature is necessary for maintaining a high cell viability and functionality in engineered cardiac tissues. Several recent studies have shown the ability to generate tissues up to a centimeter scale with a perfusable vascular network. Future challenges include improving cell density and tissue size. This requires the close collaboration of a multidisciplinary teams of investigators to overcome complex challenges in order to achieve success.


  • Consecutive operative procedures in patients with Marfan syndrome up to 28 years after initial aortic root surgery

    by Nazan Puluca, Melchior Burri, Julie Cleuziou, Markus Krane, Rüdiger Lange

    Most patients (75%) with Marfan syndrome present with aortic root dilatation that may require surgical intervention. However, associated cardiovascular disorders are not limited to the aortic root. These patients frequently require consecutive operations on the remaining thoracic aorta or the heart valves. Our intent was to characterize the spectrum of such procedures. Data from all patients with Marfan syndrome undergoing aortic root surgery at our centre between 1988 and 2016 were analysed retrospectively. Overall, 73 patients (26 women) were selected for the study. The median age at 1st operation was 30 years (3–68 years). Indications for aortic root surgery were aneurysm (78%) and dissection (22%). Initially, 33 Bentall procedures and 40 valve-sparing root replacement procedures were performed, with a 97% rate of follow-up completion. The median follow up was 8 years (0–28 years). Survival at 1, 10 and 15 years was 100%, 85% and 82%, respectively. During follow-up monitoring, 48 subsequent procedures were performed in 33 patients (aorta, 23; aortic valve, 11; mitral valve, 7 and combined procedures, 7). The 30-day mortality rate after subsequent procedures was 4.2%. Freedom from subsequent operation and death (combined end-point) after 5, 10 and 15 years was 70%, 53% and 34%, respectively. After the initial surgery, subsequent procedures required in the setting of Marfan syndrome most often involve the remaining native aorta, followed by the aortic and mitral valves. The continued need for additional operative procedures remains high, even decades after the initial surgeries are undertaken. Therefore, long-term patient monitoring at specialized centres is imperative.