Kirill Sharko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kirill Sharko has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Dmitrii Kaplun
School of Computer Science and Technology/School of Artificial Intelligence, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Irina Arustamyan
ENT Department with Clinic, Pavlov First Saint Petersburg State Medical University, 197022 St Petersburg, Russia
1 shared publication - Mikhail I. Bogachev
Saint Petersburg Electrotechnical University LETI
1 shared publication - Olga A. Stancheva
Pavlov First Saint Petersburg State Medical University
1 shared publication - Sergey Anatol'EVich Karpishchenko
Pavlov First Saint Petersburg State Medical University
1 shared publication
Latest Publications
- Open Access
- 28 May 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (6) , 350
Intraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography
Isolated sphenoid sinus disease (ISSD) is where there is a group of pathologies characterized by inflammation in one or both sphenoid sinuses. Although computer tomography (CT)-based 3D reconstruction remains the gold standard among noninvasive approaches to ISSD diagnostics, no standardized techniques for direct intraoperative measurements of the sphenoid sinus volume in ISSD patients have been documented. We suggest a novel technique for the intraoperative measurement of the sphenoid sinus volume. Our technique is based on filling the sinus with 0.01% methylene blue solution after an endoscopic endonasal sphenoidotomy. The proposed technique was applied to 40 ISSD patients during surgery. Obtained intraoperative measurements were compared to noninvasive measurements from 3D reconstructions based on preoperative CT scans. Our results demonstrated that the obtained measurements did not exhibit significant differences exceeding 0.4 cm3, with CT-scan-based measurements in 39 out of 40 cases (p < 10−6, Wilcoxon sign-rank nonparametric test), thus confirming the accuracy of the proposed technique. Disagreements between direct intraoperative and CT-based measurements in a single case have been attributed to the presence of remaining pathological masses in the sinus, which was further confirmed during the secondary check of the operated sinus. Accordingly, we suggest that the agreement between the CT-based and intraoperative volume measurements can be used as an indicator of the successful elimination of all pathological masses from the sinus without having to perform an adequate exposure of the entire sphenoid sinus to reduce intraoperative bleeding. The proposed technique is accurate and does not require the involvement of specialized intraoperative CT scanners and avoids additional radiation exposure for the patient during an additional postoperation CT scan to confirm the success of the surgery.
- 28 May 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (6) , 350
Open AccessIntraoperative Sphenoid Sinus Volume Measurement as an Alternative Technique to Intraoperative Computer Tomography
Isolated sphenoid sinus disease (ISSD) is where there is a group of pathologies characterized by inflammation in one or both sphenoid sinuses. Although computer tomography (CT)-based 3D reconstruction remains the gold standard among noninvasive approaches to ISSD diagnostics, no standardized techniques for direct intraoperative measurements of the sphenoid sinus volume in ISSD patients have been documented. We suggest a novel technique for the intraoperative measurement of the sphenoid sinus volume. Our technique is based on filling the sinus with 0.01% methylene blue solution after an endoscopic endonasal sphenoidotomy. The proposed technique was applied to 40 ISSD patients during surgery. Obtained intraoperative measurements were compared to noninvasive measurements from 3D reconstructions based on preoperative CT scans. Our results demonstrated that the obtained measurements did not exhibit significant differences exceeding 0.4 cm3, with CT-scan-based measurements in 39 out of 40 cases (p < 10−6, Wilcoxon sign-rank nonparametric test), thus confirming the accuracy of the proposed technique. Disagreements between direct intraoperative and CT-based measurements in a single case have been attributed to the presence of remaining pathological masses in the sinus, which was further confirmed during the secondary check of the operated sinus. Accordingly, we suggest that the agreement between the CT-based and intraoperative volume measurements can be used as an indicator of the successful elimination of all pathological masses from the sinus without having to perform an adequate exposure of the entire sphenoid sinus to reduce intraoperative bleeding. The proposed technique is accurate and does not require the involvement of specialized intraoperative CT scanners and avoids additional radiation exposure for the patient during an additional postoperation CT scan to confirm the success of the surgery.