JSJiangtao Su

Jiangtao Su

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jiangtao Su has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Characteristics Prediction and Optimization of GaN CAVET Using a Novel Physics-Guided Machine Learning Method

    by Wenbo Wu, Jie Wang, Jiangtao Su, Zhanfei Chen, Zhiping Yu

    This paper presents a physics-guided machine learning (PGML) approach to model the I–V characteristics of GaN current aperture vertical field effect transistors (CAVET). By adopting the method of transfer learning and the shortcut structure, a physically guided neural network model is established. The shallow neural network with tanh as the basis function is combined with a hypernetwork that dynamically generates its weight parameters. The influence of transconductance is added to the loss function. This model can synchronously predict the output and transfer characteristics of the device. Under the condition of small samples, the prediction error is controlled within 5%, and the R2 value reaches above 0.99. The proposed PGML approach outperforms conventional approaches, ensuring physically meaningful and robust predictions for device optimization and circuit-level simulations.


  • Open Access

    Biosensor with Microchannel for Broadband Dielectric Characterization of Nanoliter Cell Suspensions up to 110 GHz

    by Wen Sun, Jianhua Wang, Jin Chen, Xiwei Huang, Xin Rao, Jiangtao Su, Yuqiao Huang, Boyu Zhang, Lingling Sun

    Cell dielectric property measurement holds significant potential for application in cell detection and diagnosis due to its label-free and noninvasive nature. In this study, we developed a biosensor designed to measure the permittivity of liquid samples, particularly cell suspensions at the nanoliter scale, utilizing microwave and millimeter wave coplanar waveguides in conjunction with a microchannel. This biosensor facilitates the measurement of scattering parameters within a frequency domain ranging from 1 GHz to 110 GHz. The obtained scattering parameters are then converted into dielectric constants using specific algorithms. A cell capture structure within the microchannel ensures that cell suspensions remain stable within the measurement zone. The feasibility of this biosensor was confirmed by comparison with a commercial Keysight probe. We measured the dielectric constants of three different cell suspensions (HepG2, A549, MCF-7) using our biosensor. We also counted the number of cells captured in multiple measurements for each cell type and compared the corresponding changes in permittivity. The results indicated that the real part of the permittivity of HepG2 cells is 0.2–0.8 lower than that of the other two cell types. The difference between A549 and MCF-7 was relatively minor, only 0.2–0.4. The fluctuations in the dielectric spectrum caused by changes in cell numbers during measurements were smaller than the differences observed between different cell types. Thus, the sensor is suitable for measuring cell suspensions and can be utilized for label-free, noninvasive studies in identifying biological cell suspensions.


  • Open Access

    Review of RF Device Behavior Model: Measurement Techniques, Applications, and Challenges

    by Haode Li, Jiangtao Su, Ruijin Wang, Zhenyu Liu, Mengmeng Xu

    This review presents a concise overview of RF (radio frequency) power transistor behavior models, which is crucial for optimizing RF performance in high-frequency applications like wireless communication, radar, and satellites. The paper highlights the significance of accurate modeling in understanding transistor behavior and traces the evolution of behavior modeling techniques. Different behavior modeling strategies, such as LUT (look-up table) based models, polynomial equation-based models, and machine learning based models, are discussed along with their unique characteristics and modeling challenges. The review explores the difference between behavior models and the conventional empirical or physics-based modeling approaches, addressing the challenges of the accurate characterization of transistors at high frequencies and power levels. This paper concludes with an outlook of emerging trends, such as physical models combined with behavior models, shaping the future of RF power transistor modeling for more efficient communication systems.


  • Open Access

    RF Characterization of GaAs HBT under Load Mismatch with Reverse Wave Injection Technique

    by Yidong Xu, Yuxiu Tong, Jiangtao Su

    RF PAs need to be reliable enough to protect them from damage under load mismatch conditions. This paper investigated the characteristics of GaAs heterojunction bipolar transistors (HBTs) under load mismatch conditions using a novel reverse wave injection technique to realize large VSWR ruggedness measurement with the circle centered at 50 Ohm and optimal impedance separately to analyze the device in real applications. With a real-time waveform measurement system, the RF voltage and current waveform information can be acquired, which provide a more-accurate view of what is occurring at the current generator plane of the HBT device. Thereby, the potential failure mechanisms and load impedance can be identified to design the most-suitable PA circuits in communication systems.


  • Open Access

    Design and Implementation of Broadband Hybrid 3-dB Couplers with Silicon-Based IPD Technology

    by Mengmeng Xu, Jiangtao Su, Ruijin Wang, Zhongjie Lin, Weiyu Xie, Jun Liu

    Heterogeneous integration (HI) is a rapidly developing field aimed at achieving high-density integration and miniaturization of devices for complex practical radio frequency (RF) applications. In this study, we present the design and implementation of two 3 dB directional couplers utilizing the broadside-coupling mechanism and silicon-based integrated passive device (IPD) technology. The type A coupler incorporates a defect ground structure (DGS) to enhance coupling, while type B employs wiggly-coupled lines to improve directivity. Measurement results demonstrate that type A achieves <−16.16 dB isolation and <−22.32 dB return loss with a relative bandwidth of 60.96% in the 6.5–12.2 GHz range, while type B achieves <−21.21 dB isolation and <−23.95 dB return loss in the first band at 7–13 GHz, <−22.17 dB isolation and <−19.67 dB return loss in the second band at 28–32.5 GHz, and <−12.79 dB isolation and <−17.02 dB return loss in the third band at 49.5–54.5 GHz. The proposed couplers are well suited for low cost, high performance system-on-package radio frequency front-end circuits in wireless communication systems.


  • Open Access

    Modeling the Effects of Threading Dislocations on Current in AlGaN/GaN HEMT

    by Censong Liu, Jie Wang, Zhanfei Chen, Jun Liu, Jiangtao Su

    The aim of this paper is to model the effects of threading dislocations on both gate and drain currents of AlGaN/GaN high electron mobility transistors (HEMTs). The fraction of filled traps increases with the threading dislocations, while the trapping effects cause a decrease in drain current and an increase in gate leakage current. To model the drain current drop, the two simplified RC subcircuits with diodes are proposed to capture the charge trapping/detrapping characteristics. The trap voltages Vg_trap and Vd_trap generated by RC networks are fed back into the model to capture the effects of traps on drain current. Considering acceptor-decorated dislocations, we present a novel Poole–Frenkel (PF) model to precisely describe the reverse leakage gate current, which plays a dominant role in the gate leakage current. The proposed model, which uses physical parameters only, is implemented in Verilog-A. It is in excellent agreement with the experimental data.


  • Open Access

    Multiphysics Analysis and Optimal Design of Compressible Micro-Interconnect for 2.5D/3D Heterogeneous Integration

    by Peng Zhang, Da-Wei Wang, Wen-Sheng Zhao, Jiangtao Su, Bin You, Jun Liu

    Compressible Micro-Interconnect (CMI) shows tremendous potential in 2.5D/3D heterogeneous integration due to its outstanding performance in integration, electrical isolation, and thermal management. In this work, an optimal design approach for CMIs is developed based on a coupling framework of multiphysics simulation and particle swarm optimization (PSO). In the framework, the mechanical simulation was conducted firstly to obtain the stress distributions as CMI switched from the initial state to the working position. The contact resistance between CMI and the top pad was modeled and quantitively analyzed. Subsequently, the PSO method was utilized to implement the structural optimization of CMI to improve the performance. Multiphysics simulations of both the original and optimized CMIs were carried out and compared. With the implementation of the optimized CMIs, the contact resistance dropped from 155.3 mΩ to 108.8 mΩ, which brought significant improvement in both DC voltage drop and self-heating effect. The influence of the self-heating effect on the electrical performance of CMI is also discussed qualitatively.


  • Open Access

    Realization of Accurate Load Impedance Characterization for On-Wafer TRM Calibration

    by Jiangtao Su, Jianhua Wang, Fei Wang, Lingling Sun

    In this paper, the uncertainty and the impact of imperfect load calibration standard for on-wafer Through-Reflect-Match calibration method are analyzed with the help of 3D electromagnetic simulations. Based on the finding that load impedance can lead to significant errors in calibration, an automatic algorithm to determine the complex impedance of the load standard is proposed. This method evaluates the resistance as well as the parasitic inductance introduced by the misalignment of the probe tip to the substrate pad at mm-wave frequencies or the non-precize load standard. The proposed algorithm was verified by practical measurement, and the results show that by incorporating actual load impedance into the calibration algorithm, the deviations of RF measurement results are greatly suppressed.


  • Open Access

    128.76–129.56 GHz Fundamental Voltage Control Oscillator in 65 nm CMOS

    by Guodong Su, Dirong Chen, Kaixuan Pang, Haijun Gao, Jiangtao Su, Lingling Sun

    This paper presented a fundamental voltage control oscillator (VCO), and its operating frequency ranged from 128.76 GHz to 129.56 GHz. A differential low negative coupling shield switch (DLNCSS) inductor was proposed and analyzed, which helped to improve the tuning range and phase noise of the presented VCO. Meanwhile, an improved transformer-coupled resonant tank, which consisted of DLNCSS inductor and differential varactor using the common-cathode structure, was used to improve the phase noise of the proposed VCO further. This presented VCO was designed and fabricated by using 65 nm CMOS process, which occupied a compact area of 0.23 mm2, including all testing pads. The measurement results showed that this VCO consumed 11.2 mW from a 1.4 V supply and had the tuning range of 0.8 GHz. The output power ranged from −11.8 dBm to −10.6 dBm in its operating frequency band. The post-layout simulation showed that the phase noise at 1 MHz was better than −82 dBc/Hz.


  • A Surface Acoustic Wave Pumped Lensless Microfluidic Imaging System for Flowing Cell Detection and Counting

    by Xiwei Huang, Umar Farooq, Jin Chen, Yakun Ge, Haijun Gao, Jiangtao Su, Xiang Wang, Shurong Dong, Ji-Kui Luo

    The future point-of-care diagnostics requires miniaturizing the existing bulky and expensive bioanalysis instruments, where lab-on-CMOS-chip-based technology can provide a promising solution. In this paper, we presented a surface acoustic wave (SAW) pumped lensless microfluidic imaging system for flowing cell detection and counting. Different from the previous lensless systems, which employ external bulky syringe pump for cell driven, the developed system directly integrates the SAW pump on the CMOS image sensor chip to drive the cell-containing microfluid. Moreover, an efficient temporal-differencing-based motion detection algorithm is proposed for continuous flowing cell detection and counting. Experimental results show that the SAW pump can drive the cells to flow at different driven powers, and also can keep the channel temperature below 40 °C so as not to harm the cells. The human bone marrow stromal cells flowing in the microfluidic channel can be automatically detected and counted with a low statistical error rate of −6.53%. The developed system thereby is competitive for point-of-care cell detection and counting application.