Emily A. Mirro
Emily A. Mirro has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
Nathan B. Fountain
University of Virginia, Charlottesville, Virginia, U.S.A.
3 shared publicationsBarbara C. Jobst
Geisel School of Medicine at Dartmouth, Lebanon, New Hampshire, U.S.A.
2 shared publicationsChristianne N. Heck
Keck School of Medicine at University of Southern California, Los Angeles, CA, USA
2 shared publicationsDavid C. Spencer
Oregon Health and Science University, Portland, Oregon, 97239, U.S.A.
2 shared publicationsDileep R. Nair
Cleveland Clinic Foundation, Cleveland, OH, USA
2 shared publicationsEdward F. Chang
Department of Neurological Surgery and Weill Institute for Neurosciences, University of California, San Francisco, CA, 94143, USA
2 shared publications
Latest Publications
- Open Access
- 30 October 2023
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 41 (6) , 522-529
Long-Term Intracranial EEG Lateralization of Epileptogenicity in Patients With Confirmed or Suspected Bilateral Mesial Temporal Lobe Onsets During Epilepsy Surgical Evaluation
Purpose: The data resulting from epilepsy surgical evaluation are occasionally unclear in cases of mesial temporal lobe (MTL) epilepsy. Long-term intracranial EEG (iEEG) collected by the Responsive Neurostimulation (RNS) System may be an approach for capturing additional seizure data while treating patients with neurostimulation. We reviewed iEEG seizure lateralization and clinical outcomes in bilateral MTL patients at University of Utah. Methods: Long-term RNS System iEEG seizure lateralization was compared with pre-RNS System lateralization obtained during surgical evaluation. Safety and clinical outcomes were extracted retrospectively from patient records. Results: Twenty-six patients received an RNS System with bilateral MTL leads. Fifteen of the patients had adequate follow-up to report clinical outcomes (>1 year), and 25 patients had enough recorded data (>6 months) to perform iEEG analysis. Median percent reduction in clinical seizures at last follow-up was 58%, and 40% reported being seizure-free at last follow-up, for variable durations. The electrographic seizure lateralization (unilateral vs. bilateral) differed between surgical evaluation and long-term iEEG in 44% of our patients. In the subset of eight patients (32%) who had only unilateral seizures recorded during surgical evaluation, but were implanted with bilateral MTL leads based on bilateral interictal epileptiform discharges, 62% (5/8) had bilateral seizures recorded on long-term iEEG. Interestingly, in the 18 patients who had bilateral seizures recorded during surgical evaluation, 28% (5/18) were found to be unilateral on long-term iEEG. Conclusions: Our data suggest that RNS System implantation in suspected bilateral MTL cases may be an option to assess a patient's true seizure lateralization on long-term iEEG. Responsive neuromodulation should be considered before resection or ablation in cases that have evaluation data suggesting bilaterality.
- 30 October 2023
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 41 (6) , 522-529
Open AccessLong-Term Intracranial EEG Lateralization of Epileptogenicity in Patients With Confirmed or Suspected Bilateral Mesial Temporal Lobe Onsets During Epilepsy Surgical Evaluation
Purpose: The data resulting from epilepsy surgical evaluation are occasionally unclear in cases of mesial temporal lobe (MTL) epilepsy. Long-term intracranial EEG (iEEG) collected by the Responsive Neurostimulation (RNS) System may be an approach for capturing additional seizure data while treating patients with neurostimulation. We reviewed iEEG seizure lateralization and clinical outcomes in bilateral MTL patients at University of Utah. Methods: Long-term RNS System iEEG seizure lateralization was compared with pre-RNS System lateralization obtained during surgical evaluation. Safety and clinical outcomes were extracted retrospectively from patient records. Results: Twenty-six patients received an RNS System with bilateral MTL leads. Fifteen of the patients had adequate follow-up to report clinical outcomes (>1 year), and 25 patients had enough recorded data (>6 months) to perform iEEG analysis. Median percent reduction in clinical seizures at last follow-up was 58%, and 40% reported being seizure-free at last follow-up, for variable durations. The electrographic seizure lateralization (unilateral vs. bilateral) differed between surgical evaluation and long-term iEEG in 44% of our patients. In the subset of eight patients (32%) who had only unilateral seizures recorded during surgical evaluation, but were implanted with bilateral MTL leads based on bilateral interictal epileptiform discharges, 62% (5/8) had bilateral seizures recorded on long-term iEEG. Interestingly, in the 18 patients who had bilateral seizures recorded during surgical evaluation, 28% (5/18) were found to be unilateral on long-term iEEG. Conclusions: Our data suggest that RNS System implantation in suspected bilateral MTL cases may be an option to assess a patient's true seizure lateralization on long-term iEEG. Responsive neuromodulation should be considered before resection or ablation in cases that have evaluation data suggesting bilaterality.
- Open Access
- 27 February 2021
- Published by Wiley in Epilepsia Open
- Vol. 6 (2) , 419-424
Brain‐Responsive Neurostimulation for the treatment of adults with epilepsy in tuberous sclerosis complex: A case series
Objective: Tuberous sclerosis complex (TSC) is a genetic disorder primarily characterized by the development of multisystem benign tumors. Epilepsy is the most common neurologic manifestation, affecting 80%‐90% of TSC patients. The diffuse structural brain abnormalities and the multifocal nature of epilepsy in TSC pose diagnostic challenges when evaluating patients for epilepsy surgery.Methods: We retrospectively reviewed the safety experience and efficacy outcomes of five adult TSC patients who were treated with direct brain‐responsive neurostimulation (RNS System, NeuroPace, Inc).Results: The average follow‐up duration was 20 months. All five patients were responders (≥50% disabling seizure reduction) at last follow‐up. The median reduction in disabling seizures was 58% at 1 year and 88% at last follow‐up. Three of the five patients experienced some period of seizure freedom ranging from 3 months to over 1 year.Significance: In this small case series, we report the first safety experience and efficacy outcomes in patients with TSC‐associated drug‐resistant focal epilepsy treated with direct brain‐responsive neurostimulation.
- 27 February 2021
- Published by Wiley in Epilepsia Open
- Vol. 6 (2) , 419-424
Open AccessBrain‐Responsive Neurostimulation for the treatment of adults with epilepsy in tuberous sclerosis complex: A case series
Objective: Tuberous sclerosis complex (TSC) is a genetic disorder primarily characterized by the development of multisystem benign tumors. Epilepsy is the most common neurologic manifestation, affecting 80%‐90% of TSC patients. The diffuse structural brain abnormalities and the multifocal nature of epilepsy in TSC pose diagnostic challenges when evaluating patients for epilepsy surgery.Methods: We retrospectively reviewed the safety experience and efficacy outcomes of five adult TSC patients who were treated with direct brain‐responsive neurostimulation (RNS System, NeuroPace, Inc).Results: The average follow‐up duration was 20 months. All five patients were responders (≥50% disabling seizure reduction) at last follow‐up. The median reduction in disabling seizures was 58% at 1 year and 88% at last follow‐up. Three of the five patients experienced some period of seizure freedom ranging from 3 months to over 1 year.Significance: In this small case series, we report the first safety experience and efficacy outcomes in patients with TSC‐associated drug‐resistant focal epilepsy treated with direct brain‐responsive neurostimulation.
- Open Access
- 28 May 2020
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 87 (3) , E409-E410
Letter: Using Continuous Intracranial Electroencephalography Monitoring to Manage Epilepsy Patients During COVID-19
- 28 May 2020
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 87 (3) , E409-E410
Open AccessLetter: Using Continuous Intracranial Electroencephalography Monitoring to Manage Epilepsy Patients During COVID-19
- Open Access
Mesial temporal resection following long‐term ambulatory intracranial EEG monitoring with a direct brain‐responsive neurostimulation system
Objective: To describe seizure outcomes in patients with medically refractory epilepsy who had evidence of bilateral mesial temporal lobe (MTL) seizure onsets and underwent MTL resection based on chronic ambulatory intracranial EEG (ICEEG) data from a direct brain‐responsive neurostimulator (RNS) system.Methods: We retrospectively identified all patients at 17 epilepsy centers with MTL epilepsy who were treated with the RNS System using bilateral MTL leads, and in whom an MTL resection was subsequently performed. Presumed lateralization based on routine presurgical approaches was compared to lateralization determined by RNS System chronic ambulatory ICEEG recordings. The primary outcome was frequency of disabling seizures at last 3‐month follow‐up after MTL resection compared to seizure frequency 3 months before MTL resection.Results: We identified 157 patients treated with the RNS System with bilateral MTL leads due to presumed bitemporal epilepsy. Twenty‐five patients (16%) subsequently had an MTL resection informed by chronic ambulatory ICEEG (mean = 42 months ICEEG); follow‐up was available for 24 patients. After MTL resection, the median reduction in disabling seizures at last follow‐up was 100% (mean: 94%; range: 50%‐100%). Nine patients (38%) had exclusively unilateral electrographic seizures recorded by chronic ambulatory ICEEG and all were seizure‐free at last follow‐up after MTL resection; eight of nine continued RNS System treatment. Fifteen patients (62%) had bilateral MTL electrographic seizures, had an MTL resection on the more active side, continued RNS System treatment, and achieved a median clinical seizure reduction of 100% (mean: 90%; range: 50%‐100%) at last follow‐up, with eight of fifteen seizure‐free. For those with more than 1 year of follow‐up (N = 21), 15 patients (71%) were seizure‐free during the most recent year, including all eight patients with unilateral onsets and 7 of 13 patients (54%) with bilateral onsets.Significance: Chronic ambulatory ICEEG data provide information about lateralization of MTL seizures and can identify additional patients who may benefit from MTL resection.
Open AccessMesial temporal resection following long‐term ambulatory intracranial EEG monitoring with a direct brain‐responsive neurostimulation system
Objective: To describe seizure outcomes in patients with medically refractory epilepsy who had evidence of bilateral mesial temporal lobe (MTL) seizure onsets and underwent MTL resection based on chronic ambulatory intracranial EEG (ICEEG) data from a direct brain‐responsive neurostimulator (RNS) system.Methods: We retrospectively identified all patients at 17 epilepsy centers with MTL epilepsy who were treated with the RNS System using bilateral MTL leads, and in whom an MTL resection was subsequently performed. Presumed lateralization based on routine presurgical approaches was compared to lateralization determined by RNS System chronic ambulatory ICEEG recordings. The primary outcome was frequency of disabling seizures at last 3‐month follow‐up after MTL resection compared to seizure frequency 3 months before MTL resection.Results: We identified 157 patients treated with the RNS System with bilateral MTL leads due to presumed bitemporal epilepsy. Twenty‐five patients (16%) subsequently had an MTL resection informed by chronic ambulatory ICEEG (mean = 42 months ICEEG); follow‐up was available for 24 patients. After MTL resection, the median reduction in disabling seizures at last follow‐up was 100% (mean: 94%; range: 50%‐100%). Nine patients (38%) had exclusively unilateral electrographic seizures recorded by chronic ambulatory ICEEG and all were seizure‐free at last follow‐up after MTL resection; eight of nine continued RNS System treatment. Fifteen patients (62%) had bilateral MTL electrographic seizures, had an MTL resection on the more active side, continued RNS System treatment, and achieved a median clinical seizure reduction of 100% (mean: 90%; range: 50%‐100%) at last follow‐up, with eight of fifteen seizure‐free. For those with more than 1 year of follow‐up (N = 21), 15 patients (71%) were seizure‐free during the most recent year, including all eight patients with unilateral onsets and 7 of 13 patients (54%) with bilateral onsets.Significance: Chronic ambulatory ICEEG data provide information about lateralization of MTL seizures and can identify additional patients who may benefit from MTL resection.
- Top Cited PapersOpen Access
- 8 January 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 88
Multi-day rhythms modulate seizure risk in epilepsy
Epilepsy is defined by the seemingly random occurrence of spontaneous seizures. The ability to anticipate seizures would enable preventative treatment strategies. A central but unresolved question concerns the relationship of seizure timing to fluctuating rates of interictal epileptiform discharges (here termed interictal epileptiform activity, IEA), a marker of brain irritability observed between seizures by electroencephalography (EEG). Here, in 37 subjects with an implanted brain stimulation device that detects IEA and seizures over years, we find that IEA oscillates with circadian and subject-specific multidien (multi-day) periods. Multidien periodicities, most commonly 20–30 days in duration, are robust and relatively stable for up to 10 years in men and women. We show that seizures occur preferentially during the rising phase of multidien IEA rhythms. Combining phase information from circadian and multidien IEA rhythms provides a novel biomarker for determining relative seizure risk with a large effect size in most subjects.
- 8 January 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 88
Top Cited PapersOpen AccessMulti-day rhythms modulate seizure risk in epilepsy
Epilepsy is defined by the seemingly random occurrence of spontaneous seizures. The ability to anticipate seizures would enable preventative treatment strategies. A central but unresolved question concerns the relationship of seizure timing to fluctuating rates of interictal epileptiform discharges (here termed interictal epileptiform activity, IEA), a marker of brain irritability observed between seizures by electroencephalography (EEG). Here, in 37 subjects with an implanted brain stimulation device that detects IEA and seizures over years, we find that IEA oscillates with circadian and subject-specific multidien (multi-day) periods. Multidien periodicities, most commonly 20–30 days in duration, are robust and relatively stable for up to 10 years in men and women. We show that seizures occur preferentially during the rising phase of multidien IEA rhythms. Combining phase information from circadian and multidien IEA rhythms provides a novel biomarker for determining relative seizure risk with a large effect size in most subjects.
- 1 June 2017
- Published by Elsevier in NeuroImage
- Vol. 153, 273-282
Chronic ambulatory electrocorticography from human speech cortex
- 1 June 2017
- Published by Elsevier in NeuroImage
- Vol. 153, 273-282
Chronic ambulatory electrocorticography from human speech cortex
Circadian and ultradian patterns of epileptiform discharges differ by seizure‐onset location during long‐term ambulatory intracranial monitoring
Summary: Objective: Previous studies reporting circadian patterns of epileptiform activity and seizures are limited by (1) short‐term recording in an epilepsy monitoring unit (EMU) with altered antiepileptic drugs (AEDs) and sleep, or (2) subjective seizure diary reports. We studied circadian patterns using long‐term ambulatory intracranial recordings captured by the NeuroPace RNS System.Methods: Retrospective study of RNS System trial participants with stable detection parameters over a continuous 84‐day period. We analyzed all detections and long device–detected epileptiform events (long episodes) and defined a subset of subjects in whom long episodes represented electrographic seizures (LE‐SZ). Spectrum resampling determined the dominant frequency periodicity and cosinor analysis identified significant circadian peaks in detected activity. Chi‐square analysis was used to compare subjects grouped by region of seizure onset.Results: In the 134 subjects, detections showed a strongly circadian and uniform pattern irrespective of region of onset that peaked during normal sleep hours. In contrast, long episodes and LE‐SZ patterns varied by region. Neocortical regions had a monophasic, nocturnally dominant rhythm, whereas limbic regions showed a more complex pattern and diurnal peak. Rhythms in some individual limbic subjects were best fit by a dual oscillator (circadian + ultradian) model.Significance: Epileptiform activity has a strong 24 h periodicity with peak nocturnal occurrence. Limbic and neocortical epilepsy show divergent circadian influences. These findings confirm that circadian patterns of epileptiform activity vary by seizure‐onset zone, with implications for treatment and safety, including SUDEP.
Circadian and ultradian patterns of epileptiform discharges differ by seizure‐onset location during long‐term ambulatory intracranial monitoring
Summary: Objective: Previous studies reporting circadian patterns of epileptiform activity and seizures are limited by (1) short‐term recording in an epilepsy monitoring unit (EMU) with altered antiepileptic drugs (AEDs) and sleep, or (2) subjective seizure diary reports. We studied circadian patterns using long‐term ambulatory intracranial recordings captured by the NeuroPace RNS System.Methods: Retrospective study of RNS System trial participants with stable detection parameters over a continuous 84‐day period. We analyzed all detections and long device–detected epileptiform events (long episodes) and defined a subset of subjects in whom long episodes represented electrographic seizures (LE‐SZ). Spectrum resampling determined the dominant frequency periodicity and cosinor analysis identified significant circadian peaks in detected activity. Chi‐square analysis was used to compare subjects grouped by region of seizure onset.Results: In the 134 subjects, detections showed a strongly circadian and uniform pattern irrespective of region of onset that peaked during normal sleep hours. In contrast, long episodes and LE‐SZ patterns varied by region. Neocortical regions had a monophasic, nocturnally dominant rhythm, whereas limbic regions showed a more complex pattern and diurnal peak. Rhythms in some individual limbic subjects were best fit by a dual oscillator (circadian + ultradian) model.Significance: Epileptiform activity has a strong 24 h periodicity with peak nocturnal occurrence. Limbic and neocortical epilepsy show divergent circadian influences. These findings confirm that circadian patterns of epileptiform activity vary by seizure‐onset zone, with implications for treatment and safety, including SUDEP.
- Open Access
Lateralization of mesial temporal lobe epilepsy with chronic ambulatory electrocorticography
Summary: Objective: Patients with suspected mesial temporal lobe (MTL) epilepsy typically undergo inpatient video–electroencephalography (EEG) monitoring with scalp and/or intracranial electrodes for 1 to 2 weeks to localize and lateralize the seizure focus or foci. Chronic ambulatory electrocorticography (ECoG) in patients with MTL epilepsy may provide additional information about seizure lateralization. This analysis describes data obtained from chronic ambulatory ECoG in patients with suspected bilateral MTL epilepsy in order to assess the time required to determine the seizure lateralization and whether this information could influence treatment decisions.Methods: Ambulatory ECoG was reviewed in patients with suspected bilateral MTL epilepsy who were among a larger cohort with intractable epilepsy participating in a randomized controlled trial of responsive neurostimulation. Subjects were implanted with bilateral MTL leads and a cranially implanted neurostimulator programmed to detect abnormal interictal and ictal ECoG activity. ECoG data stored by the neurostimulator were reviewed to determine the lateralization of electrographic seizures and the interval of time until independent bilateral MTL electrographic seizures were recorded.Results: Eighty‐two subjects were implanted with bilateral MTL leads and followed for 4.7 years on average (median 4.9 years). Independent bilateral MTL electrographic seizures were recorded in 84%. The average time to record bilateral electrographic seizures in the ambulatory setting was 41.6 days (median 13 days, range 0–376 days). Sixteen percent had only unilateral electrographic seizures after an average of 4.6 years of recording.Significance: About one third of the subjects implanted with bilateral MTL electrodes required >1 month of chronic ambulatory ECoG before the first contralateral MTL electrographic seizure was recorded. Some patients with suspected bilateral MTL seizures had only unilateral electrographic seizures. Chronic ambulatory ECoG in patients with suspected bilateral MTL seizures provides data in a naturalistic setting, may complement data from inpatient video‐EEG monitoring, and can contribute to treatment decisions.
Open AccessLateralization of mesial temporal lobe epilepsy with chronic ambulatory electrocorticography
Summary: Objective: Patients with suspected mesial temporal lobe (MTL) epilepsy typically undergo inpatient video–electroencephalography (EEG) monitoring with scalp and/or intracranial electrodes for 1 to 2 weeks to localize and lateralize the seizure focus or foci. Chronic ambulatory electrocorticography (ECoG) in patients with MTL epilepsy may provide additional information about seizure lateralization. This analysis describes data obtained from chronic ambulatory ECoG in patients with suspected bilateral MTL epilepsy in order to assess the time required to determine the seizure lateralization and whether this information could influence treatment decisions.Methods: Ambulatory ECoG was reviewed in patients with suspected bilateral MTL epilepsy who were among a larger cohort with intractable epilepsy participating in a randomized controlled trial of responsive neurostimulation. Subjects were implanted with bilateral MTL leads and a cranially implanted neurostimulator programmed to detect abnormal interictal and ictal ECoG activity. ECoG data stored by the neurostimulator were reviewed to determine the lateralization of electrographic seizures and the interval of time until independent bilateral MTL electrographic seizures were recorded.Results: Eighty‐two subjects were implanted with bilateral MTL leads and followed for 4.7 years on average (median 4.9 years). Independent bilateral MTL electrographic seizures were recorded in 84%. The average time to record bilateral electrographic seizures in the ambulatory setting was 41.6 days (median 13 days, range 0–376 days). Sixteen percent had only unilateral electrographic seizures after an average of 4.6 years of recording.Significance: About one third of the subjects implanted with bilateral MTL electrodes required >1 month of chronic ambulatory ECoG before the first contralateral MTL electrographic seizure was recorded. Some patients with suspected bilateral MTL seizures had only unilateral electrographic seizures. Chronic ambulatory ECoG in patients with suspected bilateral MTL seizures provides data in a naturalistic setting, may complement data from inpatient video‐EEG monitoring, and can contribute to treatment decisions.
- Open Access
Interrater reliability in interpretation of electrocorticographic seizure detections of the responsive neurostimulator
Summary: Objective: Electrocorticographic (ECoG) recordings from patients with medically intractable partial‐onset seizures treated with a responsive neurostimulator system (the RNS System) that detects and stores physician‐specified ECoG events provide a new data resource. Interpretation of these recordings has not yet been validated. The purpose was to evaluate the interrater interpretation of chronic ambulatory ECoG recordings obtained by the RNS System.Methods: Five pairs of five experts independently classified 7,221 ECoG recordings obtained from 128 patients with medically intractable partial seizures who participated in a randomized controlled trial of the safety and efficacy of the RNS System. ECoG detections—“long episodes” or “saturations”—were classified as “seizures” or “not seizures” based on a reference definition. Interrater agreement rates and kappa score reliabilities were calculated between rater pairs from the ECoG sample as a whole and within individual patients who had more than the median number of individual ECoG recordings.Results: The overall interrater agreement was 79%, with a reliability κ = 0.57 (moderate agreement). Agreement between pairs of reviewers ranged from 0.69 to 0.85. Agreement rates were 94% or better for 50% of patients. Only 25% of patients had ECoG recordings agreement rates worse than 75%. ECoGs with mixed interpretations (one reviewer “seizure”/the other—“not seizure”) consisted of periods of low amplitude activity that evolved in amplitude or periodic discharges near 2 Hz.Significance: Although reliability as a whole was moderate, for the majority of patients, detections yielded highly reliably interpreted events of either electrographic seizures or nonictal epileptiform activity.
Open AccessInterrater reliability in interpretation of electrocorticographic seizure detections of the responsive neurostimulator
Summary: Objective: Electrocorticographic (ECoG) recordings from patients with medically intractable partial‐onset seizures treated with a responsive neurostimulator system (the RNS System) that detects and stores physician‐specified ECoG events provide a new data resource. Interpretation of these recordings has not yet been validated. The purpose was to evaluate the interrater interpretation of chronic ambulatory ECoG recordings obtained by the RNS System.Methods: Five pairs of five experts independently classified 7,221 ECoG recordings obtained from 128 patients with medically intractable partial seizures who participated in a randomized controlled trial of the safety and efficacy of the RNS System. ECoG detections—“long episodes” or “saturations”—were classified as “seizures” or “not seizures” based on a reference definition. Interrater agreement rates and kappa score reliabilities were calculated between rater pairs from the ECoG sample as a whole and within individual patients who had more than the median number of individual ECoG recordings.Results: The overall interrater agreement was 79%, with a reliability κ = 0.57 (moderate agreement). Agreement between pairs of reviewers ranged from 0.69 to 0.85. Agreement rates were 94% or better for 50% of patients. Only 25% of patients had ECoG recordings agreement rates worse than 75%. ECoGs with mixed interpretations (one reviewer “seizure”/the other—“not seizure”) consisted of periods of low amplitude activity that evolved in amplitude or periodic discharges near 2 Hz.Significance: Although reliability as a whole was moderate, for the majority of patients, detections yielded highly reliably interpreted events of either electrographic seizures or nonictal epileptiform activity.