AAAli Asghari Adib

Ali Asghari Adib

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ali Asghari Adib has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Advancing extrusion-based embedded 3D bioprinting via scientific, engineering, and process innovations

    by Ezgi Bakirci, Ali Asghari Adib, Syed Faaz Ashraf, Adam W Feinberg

    Extrusion-based embedded 3D bioprinting, where bioinks and biomaterials are extruded within a support bath, has greatly expanded the achievable tissue architectures and complexity of biologic constructs that can be fabricated. However, significant scientific, engineering, and process-related challenges remain to recreate the full anatomic structure and physiologic function required for many therapeutic applications. This perspective explores the future advances in extrusion-based embedded 3D bioprinting that could address these challenges, paving the way for clinical translation of bioprinted tissues.


  • Hybrid Control of Flowrate in Microextrusion-Based Direct-Write Additive Manufacturing

    by Ali Asghari Adib, David J. Hoelzle

    Flowrate control has been a continuous challenge in Direct-Write Additive Manufacturing (DW AM) due to capacitive energy storage in the system and the lack of suitable flowrate sensors at the microscale, resulting in poor dimensional control of material addition. While a pressure sensor can be used for pressure-based feedback control, the system will become marginally stable if the material loses contact with the pressure sensor, and thus feedback is lost. In this letter, we design and implement a pressure-based hybrid controller with a state-dependent switching strategy that eliminates the stability problem due to a loss of pressure feedback, and thus enables the real time, stable control of flowrate in DW AM. The stability of the hybrid controller is assessed using phase portraits and Multiple Lyapunov-like Functions. The hybrid dynamical model and the hybrid controller are experimentally implemented and validated. Stability results indicate that the hybrid controller resolved the marginal stability issue, and is stable in the sense of Lyapunov. Moreover, the hybrid control scheme implementation in the case study demonstrated that the shape fidelity of the parts is appreciably enhanced compared to the open loop control case.


  • Direct-write 3D printing and characterization of a GelMA-based biomaterial for intracorporeal tissue engineering

    by Ali Asghari Adib, Amir Sheikhi, Melika Shahhosseini, Andrej Simeunović, Shuai Wu, C E Castro, Ruike Zhao, Ali Khademhosseini, David John Hoelzle

    We develop and characterize a biomaterial formulation and robotic methods tailored for intracorporeal tissue engineering (TE) via direct-write (DW) 3D printing. Intracorporeal TE is defined as the biofabrication of 3D TE scaffolds inside of a living patient, in a minimally invasive manner. A biomaterial for intracorporeal TE requires to be 3D printable and crosslinkable via mechanisms that are safe to native tissues and feasible at physiological temperature (37 °C). The cell-laden biomaterial (bioink) preparation and bioprinting methods must support cell viability. Additionally, the biomaterial and bioprinting method must enable the spatially accurate intracorporeal 3D delivery of the biomaterial, and the biomaterial must adhere to or integrate into the native tissue. Current biomaterial formulations do not meet all the presumed intracorporeal DW TE requirements. We demonstrate that a specific formulation of gelatin methacryloyl (GelMA)/Laponite ® /methylcellulose (GLM) biomaterial system can be 3D printed at physiological temperature and crosslinked using visible light to construct 3D TE scaffolds with clinically relevant dimensions and consistent structures. Cell viability of 71%–77% and consistent mechanical properties over 21 d are reported. Rheological modifiers, Laponite ® and methylcellulose, extend the degradation time of the scaffolds. The DW modality enables the piercing of the soft tissue and over-extrusion of the biomaterial into the tissue, creating a novel interlocking mechanism with soft, hydrated native tissue mimics and animal muscle with a 3.5–4 fold increase in the biomaterial/tissue adhesion strength compared to printing on top of the tissue. The developed GLM biomaterial and robotic interlocking mechanism pave the way towards intracorporeal TE.


  • Engineered silica nanoparticles interact differently with lipid monolayers compared to lipid bilayers

    by Ali Asghari Adib, Saeed Nazemidashtarjandi, Alexander Kelly, Adelaide Kruse, Katherine Cimatu, Allan E. David, Amir M. Farnoud

    Despite a number of fundamental studies, the interactions of engineered nanoparticles with the cell plasma membrane are still not well understood. Membrane models, such as lipid monolayers and bilayers, have been used to provide a mechanistic understanding of nanoparticle effects on the structure and integrity of the cell membrane. However, the role of the membrane model itself in regulating nanoparticle–lipid interactions has generally been overlooked. In an effort to elucidate how changing the membrane model affects the resulting interactions with nanoparticles, the current study investigates the interaction of silica nanoparticles (104 ± 5 nm) with different surface-functional groups: plain (silanol), amine, and poly(ethylene glycol) (PEG), with various molecular weights of 2k, 5k, and 20k Daltons, with lipid monolayers and bilayers of the same composition. Studies with lipid monolayers demonstrated that PEGylated particles, regardless of the PEG molecular weight, and unlike plain and amine-modified particles, were able to penetrate the monolayer and disrupt the structure of lipids as evidenced by tensiometry and atomic force microscopy. In contrast, when interacting with lipid bilayers in suspension (i.e. vesicles), plain, amine-modified, and PEG 20k-modified particles disrupted vesicle structure, causing significant leakage, while PEG 2k- and 5k-modified particles did not affect the integrity of the vesicles. In summary, while the interactions of silica nanoparticles with membrane models is dependent on particle surface properties, a clear difference is observed in particle interactions with lipid monolayers compared to bilayers.