Kornelia Gawlitza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kornelia Gawlitza has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Knut Rurack
Chemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, Berlin 12489, Germany
15 shared publications - Martha Kimani
Chemical and Optical Sensing Division
5 shared publications - Michael G. Weller
Federal Institute for Materials Research and Testing (BAM), Richard-Willstätter-Strasse 11, 12489 Berlin, Germany
5 shared publications - Virginia Valderrey
Bundesanstalt für Materialforschung und ‐prüfung (BAM) Berlin Germany
5 shared publications - Ines Feldmann
Federal Institute for Materials Research and Testing (BAM), Richard-Willstätter-Strasse 11, 12489 Berlin, Germany
4 shared publications - Anette Gjörloff Wingren
Department of Biomedical Sciences, Faculty of Health and Society, Malmö University, Malmö, Sweden
3 shared publications
Latest Publications
- Open Access
- 24 March 2026
- Published by Wiley in Advanced Sensor Research
- Vol. 5 (3) , e70145
Detection of Perfluoroalkylic Acids From Water Using a Guanidine‐Based Fluorescent Probe and Microfluidic Droplet Extraction
Perfluoroalkylic acids (PFAAs), a subclass of per‐ and polyfluoroalkyl substances (PFAS), are stable, widely used industrial compounds posing environmental concerns due to their persistence and toxicity. Regulatory actions and remediation strategies necessitate effective onsite analytical methods for PFAS management. We developed an optical sensing system using a fluorescent probe with a benzoxadiazole core and guanidine receptor in a droplet‐based microfluidic assay to detect PFAAs in water samples with low detection limits. The PFAAs binding enhances the probe's fluorescence in organic media through protonation‐mediated hydrogen bond‐assisted ion pairing, exploiting two complementary supramolecular forces. Direct detection employs a liquid‐liquid extraction protocol in the microfluidic device, achieving detection limits for PFOA and PFOS down to ≥0.5 µ m , with a dynamic range up to 200 µ m for sample volumes <100 µL. HCl/KCl buffering facilitates analyte desalting and phase transfer for quantitation from surface water. Additionally, we developed a method involving a thin polymer layer of the probe and a crosslinker on submicron silica particles for direct detection of PFAAs in water. Our approaches provide sensitive, direct recognition and indication of PFAAs, advancing the field beyond indirect sensing and offering improved background suppression, rapid assay times, and a modular design for targeting other PFAS subclasses.
- 24 March 2026
- Published by Wiley in Advanced Sensor Research
- Vol. 5 (3) , e70145
Open AccessDetection of Perfluoroalkylic Acids From Water Using a Guanidine‐Based Fluorescent Probe and Microfluidic Droplet Extraction
Perfluoroalkylic acids (PFAAs), a subclass of per‐ and polyfluoroalkyl substances (PFAS), are stable, widely used industrial compounds posing environmental concerns due to their persistence and toxicity. Regulatory actions and remediation strategies necessitate effective onsite analytical methods for PFAS management. We developed an optical sensing system using a fluorescent probe with a benzoxadiazole core and guanidine receptor in a droplet‐based microfluidic assay to detect PFAAs in water samples with low detection limits. The PFAAs binding enhances the probe's fluorescence in organic media through protonation‐mediated hydrogen bond‐assisted ion pairing, exploiting two complementary supramolecular forces. Direct detection employs a liquid‐liquid extraction protocol in the microfluidic device, achieving detection limits for PFOA and PFOS down to ≥0.5 µ m , with a dynamic range up to 200 µ m for sample volumes <100 µL. HCl/KCl buffering facilitates analyte desalting and phase transfer for quantitation from surface water. Additionally, we developed a method involving a thin polymer layer of the probe and a crosslinker on submicron silica particles for direct detection of PFAAs in water. Our approaches provide sensitive, direct recognition and indication of PFAAs, advancing the field beyond indirect sensing and offering improved background suppression, rapid assay times, and a modular design for targeting other PFAS subclasses.
- Open Access
Corundum Particles as Trypsin Carrier for Efficient Protein Digestion
Reusable enzyme carriers are valuable for proteomic workflows, yet many supports are expensive or lack robustness. This study describes the covalent immobilization of recombinant trypsin on micrometer-sized corundum particles and assesses their performance in protein digestion and antibody analysis. The corundum surface was cleaned with potassium hydroxide, silanized with 3-aminopropyltriethoxysilane and activated with glutaraldehyde. Recombinant trypsin was then attached, and the resulting imines were reduced with sodium cyanoborohydride. Aromatic amino acid analysis (AAAA) estimated an enzyme loading of approximately 1 µg/mg. Non-specific adsorption of human plasma proteins was suppressed by blocking residual aldehydes with a Tris-glycine-lysine buffer. Compared with free trypsin, immobilization shifted the temperature optimum from 50 to 60 °C and greatly improved stability in 1 M guanidinium hydrochloride. Activity remained above 80% across several reuse cycles, and storage at 4 °C preserved functionality for weeks. When applied to digesting the NISTmAb, immobilized trypsin provided peptide yields and sequence coverage comparable to soluble enzyme and outperformed it at elevated temperatures. MALDI-TOF MS analysis of Herceptin digests yielded fingerprint spectra that correctly identified the antibody and achieved >60% sequence coverage. The combination of low cost, robustness and analytical performance makes corundum-immobilized trypsin an attractive option for research and routine proteomic workflows.
Open AccessCorundum Particles as Trypsin Carrier for Efficient Protein Digestion
Reusable enzyme carriers are valuable for proteomic workflows, yet many supports are expensive or lack robustness. This study describes the covalent immobilization of recombinant trypsin on micrometer-sized corundum particles and assesses their performance in protein digestion and antibody analysis. The corundum surface was cleaned with potassium hydroxide, silanized with 3-aminopropyltriethoxysilane and activated with glutaraldehyde. Recombinant trypsin was then attached, and the resulting imines were reduced with sodium cyanoborohydride. Aromatic amino acid analysis (AAAA) estimated an enzyme loading of approximately 1 µg/mg. Non-specific adsorption of human plasma proteins was suppressed by blocking residual aldehydes with a Tris-glycine-lysine buffer. Compared with free trypsin, immobilization shifted the temperature optimum from 50 to 60 °C and greatly improved stability in 1 M guanidinium hydrochloride. Activity remained above 80% across several reuse cycles, and storage at 4 °C preserved functionality for weeks. When applied to digesting the NISTmAb, immobilized trypsin provided peptide yields and sequence coverage comparable to soluble enzyme and outperformed it at elevated temperatures. MALDI-TOF MS analysis of Herceptin digests yielded fingerprint spectra that correctly identified the antibody and achieved >60% sequence coverage. The combination of low cost, robustness and analytical performance makes corundum-immobilized trypsin an attractive option for research and routine proteomic workflows.
- Open Access
- 2 December 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1)
Ratiometric detection of perfluoroalkyl carboxylic acids using dual fluorescent nanoparticles and a miniaturised microfluidic platform
The widespread contamination of soil and water with perfluoroalkyl substances (PFAS) has caused considerable societal and scientific concern. Legislative measures and an increased need for remediation require effective on-site analytical methods for PFAS management. Here we report on the development of a green-fluorescent guanidine-BODIPY indicator monomer incorporated into a molecularly imprinted polymer (MIP) for the selective detection of perfluorooctanoic acid (PFOA). Complexation of PFOA by the indicator, which is mediated by concerted protonation-induced ion pairing-assisted hydrogen bonding, significantly enhances fluorescence in polar organic solvents. The MIP forms as a thin layer on silica nanoparticles doped with tris(bipyridine)ruthenium(II) chloride, which provides an orange emission signal as internal reference, resulting in low measurement uncertainties. Using a liquid-liquid extraction protocol, this assay enables the direct detection of PFOA in environmental water samples and achieves a detection limit of 0.11 µM. Integration into an opto-microfluidic system enables a compact and user-friendly system for detecting PFOA in less than 15 minutes.
- 2 December 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1)
Open AccessRatiometric detection of perfluoroalkyl carboxylic acids using dual fluorescent nanoparticles and a miniaturised microfluidic platform
The widespread contamination of soil and water with perfluoroalkyl substances (PFAS) has caused considerable societal and scientific concern. Legislative measures and an increased need for remediation require effective on-site analytical methods for PFAS management. Here we report on the development of a green-fluorescent guanidine-BODIPY indicator monomer incorporated into a molecularly imprinted polymer (MIP) for the selective detection of perfluorooctanoic acid (PFOA). Complexation of PFOA by the indicator, which is mediated by concerted protonation-induced ion pairing-assisted hydrogen bonding, significantly enhances fluorescence in polar organic solvents. The MIP forms as a thin layer on silica nanoparticles doped with tris(bipyridine)ruthenium(II) chloride, which provides an orange emission signal as internal reference, resulting in low measurement uncertainties. Using a liquid-liquid extraction protocol, this assay enables the direct detection of PFOA in environmental water samples and achieves a detection limit of 0.11 µM. Integration into an opto-microfluidic system enables a compact and user-friendly system for detecting PFOA in less than 15 minutes.
- Open Access
- 27 October 2025
- Published by MDPI AG in Preprints.org
Corundum Particles as Trypsin Carrier for Efficient Protein Digestion
Reusable enzyme carriers are valuable for proteomic workflows, yet many supports are expensive or lack robustness. This study describes the covalent immobilization of recombinant trypsin on micrometer‑sized corundum particles and assesses their performance in protein digestion and antibody analysis. The corundum surface was cleaned with potassium hydroxide, silanized with 3‑aminopropyltriethoxysilane and activated with glutaraldehyde. Recombinant trypsin was then attached, and the resulting imines were reduced with sodium cyanoborohydride. Aromatic amino acid analysis (AAAA) estimated an enzyme loading of approximately 1 µg/mg. Non‑specific adsorption of human plasma proteins was suppressed by blocking residual aldehydes with a Tris‑glycine‑lysine buffer. Compared with free trypsin, immobilization shifted the temperature optimum from 50 to 60 °C and greatly improved stability in 1 M guanidinium hydrochloride. Activity remained above 80 % across several reuse cycles, and storage at 4 °C preserved functionality for weeks. When applied to digesting the NISTmAb, immobilized trypsin provided peptide yields and sequence coverage comparable to soluble enzyme and outperformed it at elevated temperatures. MALDI‑TOF MS analysis of Herceptin digests yielded fingerprint spectra that correctly identified the antibody and achieved >60 % sequence coverage. The combination of low cost, robustness and analytical performance makes corun-dum‑immobilized trypsin an attractive option for research and routine proteomic workflows.
- 27 October 2025
- Published by MDPI AG in Preprints.org
Open AccessCorundum Particles as Trypsin Carrier for Efficient Protein Digestion
Reusable enzyme carriers are valuable for proteomic workflows, yet many supports are expensive or lack robustness. This study describes the covalent immobilization of recombinant trypsin on micrometer‑sized corundum particles and assesses their performance in protein digestion and antibody analysis. The corundum surface was cleaned with potassium hydroxide, silanized with 3‑aminopropyltriethoxysilane and activated with glutaraldehyde. Recombinant trypsin was then attached, and the resulting imines were reduced with sodium cyanoborohydride. Aromatic amino acid analysis (AAAA) estimated an enzyme loading of approximately 1 µg/mg. Non‑specific adsorption of human plasma proteins was suppressed by blocking residual aldehydes with a Tris‑glycine‑lysine buffer. Compared with free trypsin, immobilization shifted the temperature optimum from 50 to 60 °C and greatly improved stability in 1 M guanidinium hydrochloride. Activity remained above 80 % across several reuse cycles, and storage at 4 °C preserved functionality for weeks. When applied to digesting the NISTmAb, immobilized trypsin provided peptide yields and sequence coverage comparable to soluble enzyme and outperformed it at elevated temperatures. MALDI‑TOF MS analysis of Herceptin digests yielded fingerprint spectra that correctly identified the antibody and achieved >60 % sequence coverage. The combination of low cost, robustness and analytical performance makes corun-dum‑immobilized trypsin an attractive option for research and routine proteomic workflows.
- Open Access
- 9 October 2024
- Published by Taylor & Francis in Nanomedicine
- Vol. 19 (29) , 2463-2478
Detection of Tn-antigen in breast and prostate cancer models by VVL-labeled red dye-doped nanoparticles
Aim: Fluorescence detection of breast and prostate cancer cells expressing Tn-antigen, a tumor marker, with Vicia villosa lectin (VVL)-labeled nanoparticles.Materials & methods: Breast and prostate cancer cells engineered to express high levels of Tn-antigen and non-engineered controls were incubated with VVL-labeled or unlabeled red dye-doped silica-coated polystyrene nanoparticles. The binding to cells was studied with flow cytometry, confocal microscopy, and electron microscopy.Results: Flow cytometry showed that the binding of VVL-labeled nanoparticles was significantly higher to Tn-antigen-expressing cancer cells than controls. Confocal microscopy demonstrated that particles bound to the cell surface. According to the correlative light and electron microscopy the particles bound mostly as aggregates.Conclusion: VVL-labeled nanoparticles could provide a new tool for the detection of Tn-antigen-expressing breast and prostate cancer cells.
- 9 October 2024
- Published by Taylor & Francis in Nanomedicine
- Vol. 19 (29) , 2463-2478
Open AccessDetection of Tn-antigen in breast and prostate cancer models by VVL-labeled red dye-doped nanoparticles
Aim: Fluorescence detection of breast and prostate cancer cells expressing Tn-antigen, a tumor marker, with Vicia villosa lectin (VVL)-labeled nanoparticles.Materials & methods: Breast and prostate cancer cells engineered to express high levels of Tn-antigen and non-engineered controls were incubated with VVL-labeled or unlabeled red dye-doped silica-coated polystyrene nanoparticles. The binding to cells was studied with flow cytometry, confocal microscopy, and electron microscopy.Results: Flow cytometry showed that the binding of VVL-labeled nanoparticles was significantly higher to Tn-antigen-expressing cancer cells than controls. Confocal microscopy demonstrated that particles bound to the cell surface. According to the correlative light and electron microscopy the particles bound mostly as aggregates.Conclusion: VVL-labeled nanoparticles could provide a new tool for the detection of Tn-antigen-expressing breast and prostate cancer cells.
- Open Access
- 4 September 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (37) , 49944-49956
Ratiometric Molecularly Imprinted Particle Probes for Reliable Fluorescence Signaling of Carboxylate-Containing Molecules
In addition to sensitivity, selectivity, and portability, chemical sensing systems must generate reliable signals and offer modular configurability to address various small molecule targets, particularly in environmental applications. We present a versatile, modular strategy utilizing ratiometric molecularly imprinted particle probes based on BODIPY indicators and dyes for recognition and internal referencing. Our approach employs polystyrene core particles doped with a red fluorescent BODIPY as an internal standard, providing built-in reference for environmental influences. A molecularly imprinted polymer (MIP) recognition shell, incorporating a green-fluorescent BODIPY indicator monomer with a thiourea binding site for carboxylate-containing analytes, is grafted from the core particles in the presence of the analyte as the template. The dual-fluorescent MIP probe detects fexofenadine as the model analyte with a change in green emission signal referenced against a stable red signal, achieving a detection limit of 0.13 μM and a broad dynamic range from 0.16 μM to 1.2 mM, with good discrimination against other antibiotics in acetonitrile. By selecting a versatile dye scaffold and recognition element, this approach can be extended to other carboxylate-containing analytes and/or wavelength combinations, potentially serving as a robust multiplexing platform.
- 4 September 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (37) , 49944-49956
Open AccessRatiometric Molecularly Imprinted Particle Probes for Reliable Fluorescence Signaling of Carboxylate-Containing Molecules
In addition to sensitivity, selectivity, and portability, chemical sensing systems must generate reliable signals and offer modular configurability to address various small molecule targets, particularly in environmental applications. We present a versatile, modular strategy utilizing ratiometric molecularly imprinted particle probes based on BODIPY indicators and dyes for recognition and internal referencing. Our approach employs polystyrene core particles doped with a red fluorescent BODIPY as an internal standard, providing built-in reference for environmental influences. A molecularly imprinted polymer (MIP) recognition shell, incorporating a green-fluorescent BODIPY indicator monomer with a thiourea binding site for carboxylate-containing analytes, is grafted from the core particles in the presence of the analyte as the template. The dual-fluorescent MIP probe detects fexofenadine as the model analyte with a change in green emission signal referenced against a stable red signal, achieving a detection limit of 0.13 μM and a broad dynamic range from 0.16 μM to 1.2 mM, with good discrimination against other antibiotics in acetonitrile. By selecting a versatile dye scaffold and recognition element, this approach can be extended to other carboxylate-containing analytes and/or wavelength combinations, potentially serving as a robust multiplexing platform.
- Open Access
- 21 March 2024
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 5 (9) , 3783-3793
Polymerizable BODIPY probe crosslinker for the molecularly imprinted polymer-based detection of organic carboxylates via fluorescence
A novel polymerizable BODIPY-based probe targeting carboxylates for molecularly imprinted polymers (MIPs) was developed, exhibiting selective recognition of levofloxacin, enabling detection at submicromolar concentrations.
- 21 March 2024
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 5 (9) , 3783-3793
Open AccessPolymerizable BODIPY probe crosslinker for the molecularly imprinted polymer-based detection of organic carboxylates via fluorescence
A novel polymerizable BODIPY-based probe targeting carboxylates for molecularly imprinted polymers (MIPs) was developed, exhibiting selective recognition of levofloxacin, enabling detection at submicromolar concentrations.
- Open Access
- 16 October 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 11 (45) , 10873-10882
Towards molecularly imprinted polymers that respond to and capture phosphorylated tyrosine epitopes using fluorescent bis-urea and bis-imidazolium receptors
Fluorescent MIPs for rapid biomarker detection were developed, employing two functional crosslinkers, distinguishing phosphorylated peptides, and revealing insights into the influence of counterions and protective groups in the imprinting process.
- 16 October 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 11 (45) , 10873-10882
Open AccessTowards molecularly imprinted polymers that respond to and capture phosphorylated tyrosine epitopes using fluorescent bis-urea and bis-imidazolium receptors
Fluorescent MIPs for rapid biomarker detection were developed, employing two functional crosslinkers, distinguishing phosphorylated peptides, and revealing insights into the influence of counterions and protective groups in the imprinting process.
- Open Access
- 17 January 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-2
Author Correction: Fluorescent molecularly imprinted polymer particles for glyphosate detection using phase transfer agents
- 17 January 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-2
Open AccessAuthor Correction: Fluorescent molecularly imprinted polymer particles for glyphosate detection using phase transfer agents
- Open Access
- 16 November 2022
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 5 (12) , 17592-17605
Sialyl-Tn Antigen-Imprinted Dual Fluorescent Core–Shell Nanoparticles for Ratiometric Sialyl-Tn Antigen Detection and Dual-Color Labeling of Cancer Cells
Sialyl-Tn (STn or sialyl-Thomsen-nouveau) is a carbohydrate antigen expressed by more than 80% of human carcinomas. We here report a strategy for ratiometric STn detection and dual-color cancer cell labeling, particularly, by molecularly imprinted polymers (MIPs). Imprinting was based on spectroscopic studies of a urea-containing green-fluorescent monomer 1 and STn-Thr-Na (sodium salt of Neu5Ac alpha 2-6GalNAc alpha-O-Thr). A few-nanometer-thin green-fluorescent polymer shell, in which STn-Thr-Na was imprinted with 1, other comonomers, and a cross-linker, was synthesized from the surface of red-emissive carbon nanodot (R-CND)-doped silica nanoparticles, resulting in dual fluorescent STn-MIPs. Dual-color labeling of cancer cells was achieved since both red and green emissions were detected in two separate channels of the microscope and an improved accuracy was obtained in comparison with single-signal MIPs. The flow cytometric cell analysis showed that the binding of STn-MIPs was significantly higher (p < 0.001) than that of non-imprinted polymer (NIP) control particles within the same cell line, allowing to distinguish populations. Based on the modularity of the luminescent core- fluorescent MIP shell architecture, the concept can be transferred in a straightforward manner to other target analytes.
- 16 November 2022
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 5 (12) , 17592-17605
Open AccessSialyl-Tn Antigen-Imprinted Dual Fluorescent Core–Shell Nanoparticles for Ratiometric Sialyl-Tn Antigen Detection and Dual-Color Labeling of Cancer Cells
Sialyl-Tn (STn or sialyl-Thomsen-nouveau) is a carbohydrate antigen expressed by more than 80% of human carcinomas. We here report a strategy for ratiometric STn detection and dual-color cancer cell labeling, particularly, by molecularly imprinted polymers (MIPs). Imprinting was based on spectroscopic studies of a urea-containing green-fluorescent monomer 1 and STn-Thr-Na (sodium salt of Neu5Ac alpha 2-6GalNAc alpha-O-Thr). A few-nanometer-thin green-fluorescent polymer shell, in which STn-Thr-Na was imprinted with 1, other comonomers, and a cross-linker, was synthesized from the surface of red-emissive carbon nanodot (R-CND)-doped silica nanoparticles, resulting in dual fluorescent STn-MIPs. Dual-color labeling of cancer cells was achieved since both red and green emissions were detected in two separate channels of the microscope and an improved accuracy was obtained in comparison with single-signal MIPs. The flow cytometric cell analysis showed that the binding of STn-MIPs was significantly higher (p < 0.001) than that of non-imprinted polymer (NIP) control particles within the same cell line, allowing to distinguish populations. Based on the modularity of the luminescent core- fluorescent MIP shell architecture, the concept can be transferred in a straightforward manner to other target analytes.