Charles C. Harb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Charles C. Harb has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
- Hans Albert Bachor
Research School of Physics and Engineering, Australian National University, Canberra, ACT 2601, Australia
27 shared publications - Timothy Cameron Ralph
The University of Queensland
15 shared publications - Ping Koy Lam
Quantum Innovation Centre(Q.InC), Agency for Science, Technology and Research(A*STAR), Singapore, Singapore
12 shared publications Toby K. Boyson
School of Engineering and Information Technology, UNSW Australia, Canberra, ACT 2600, Australia
10 shared publicationsV. Delaubert
Centre for Quantum-Atom Optics, The Australian National University, Canberra, ACT 0200, Australia; Laboratoire Kastler-Brossel, 4 place Jussieu, case 74, Paris 75252 Cedex 05, France
10 shared publicationsE. H. Huntington
School of IT and Electrical Engineering, University College, The University of New South Wales, Canberra, ACT, 2600
9 shared publications
Latest Publications
- 21 May 2021
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 55 (12) , 8090-8096
A Rapid and Sensitive Chemical Screening Method for E-Cigarette Aerosols Based on Runtime Cavity Ringdown Spectroscopy
Growing demand of Juul and other electronic cigarettes, despite critical knowledge gaps about their chemical composition, has led to concerns regarding their potential health effects. We introduce a novel analytical approach, runtime cavity ringdown spectroscopy (rtCRDS) for rapid detection of oxidative products in e-cigarette aerosols, to facilitate the study of aerosol from a single puff of e-liquid. We report a systematic investigation of three flavors of commercial Juul pods (Virginia tobacco, mango, and menthol) and known commercial e-liquid ingredients (propylene glycol (PG), vegetable glycerin (VG), nicotine, ethyl maltol, benzoic acid, and nicotine benzoate) vaped using Juul devices. Juul e-liquids and neat chemical additives spiked into a 30:70 PG/VG solution were vaped and their aerosols were collected in 1-L Tedlar gas bags and analyzed using rtCRDS. Acetaldehyde, formaldehyde, and acetone were identified as primary oxidative products in aerosolized PG/VG. Ethanol was detected as a major constituent of the three commercial Juul flavors. Spectral intensities of carbonyl compounds increased with the addition of spikes, benzoic acid, ethyl maltol, and nicotine to PG/VG, suggesting that oxidative product generation increases with common additives. The method of direct, rapid analysis of e-cig aerosols introduced here can be used to complement traditional methods in vaping exposures.
- 21 May 2021
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 55 (12) , 8090-8096
A Rapid and Sensitive Chemical Screening Method for E-Cigarette Aerosols Based on Runtime Cavity Ringdown Spectroscopy
Growing demand of Juul and other electronic cigarettes, despite critical knowledge gaps about their chemical composition, has led to concerns regarding their potential health effects. We introduce a novel analytical approach, runtime cavity ringdown spectroscopy (rtCRDS) for rapid detection of oxidative products in e-cigarette aerosols, to facilitate the study of aerosol from a single puff of e-liquid. We report a systematic investigation of three flavors of commercial Juul pods (Virginia tobacco, mango, and menthol) and known commercial e-liquid ingredients (propylene glycol (PG), vegetable glycerin (VG), nicotine, ethyl maltol, benzoic acid, and nicotine benzoate) vaped using Juul devices. Juul e-liquids and neat chemical additives spiked into a 30:70 PG/VG solution were vaped and their aerosols were collected in 1-L Tedlar gas bags and analyzed using rtCRDS. Acetaldehyde, formaldehyde, and acetone were identified as primary oxidative products in aerosolized PG/VG. Ethanol was detected as a major constituent of the three commercial Juul flavors. Spectral intensities of carbonyl compounds increased with the addition of spikes, benzoic acid, ethyl maltol, and nicotine to PG/VG, suggesting that oxidative product generation increases with common additives. The method of direct, rapid analysis of e-cig aerosols introduced here can be used to complement traditional methods in vaping exposures.
- 28 May 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (12) , 17741-17756
Quantum cascade laser-based reflectance spectroscopy: a robust approach for the classification of plastic type
The identification of plastic type is important for environmental applications ranging from recycling to understanding the fate of plastics in marine, atmospheric, and terrestrial environments. Infrared reflectance spectroscopy is a powerful approach for plastics identification, requiring only optical access to a sample. The use of visible and near-infrared wavelengths for plastics identification are limiting as dark colored plastics absorb at these wavelengths, producing no reflectance spectra. The use of mid-infrared wavelengths instead enables dark plastics to be identified. Here we demonstrate the capability to utilize a pulsed, widely-tunable (5.59 - 7.41 µm) mid-infrared quantum cascade laser, as the source for reflectance spectroscopy, for the rapid and robust identification of plastics. Through the application of linear discriminant analysis to the resulting spectral data set, we demonstrate that we can correctly classify five plastic types: polyethylene terephthalate (PET), high density polyethylene (HDPE), low density polyethylene (LDPE), polypropylene (PP), and polystyrene (PS), with a 97% accuracy rate.
- 28 May 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (12) , 17741-17756
Quantum cascade laser-based reflectance spectroscopy: a robust approach for the classification of plastic type
The identification of plastic type is important for environmental applications ranging from recycling to understanding the fate of plastics in marine, atmospheric, and terrestrial environments. Infrared reflectance spectroscopy is a powerful approach for plastics identification, requiring only optical access to a sample. The use of visible and near-infrared wavelengths for plastics identification are limiting as dark colored plastics absorb at these wavelengths, producing no reflectance spectra. The use of mid-infrared wavelengths instead enables dark plastics to be identified. Here we demonstrate the capability to utilize a pulsed, widely-tunable (5.59 - 7.41 µm) mid-infrared quantum cascade laser, as the source for reflectance spectroscopy, for the rapid and robust identification of plastics. Through the application of linear discriminant analysis to the resulting spectral data set, we demonstrate that we can correctly classify five plastic types: polyethylene terephthalate (PET), high density polyethylene (HDPE), low density polyethylene (LDPE), polypropylene (PP), and polystyrene (PS), with a 97% accuracy rate.
- 1 October 2015
- Published by Optica Publishing Group in Optics Letters
- Vol. 40 (19) , 4560-4562
Real-time multiplexed digital cavity-enhanced spectroscopy
Cavity-enhanced spectroscopy is a sensitive optical absorption technique but one where the practical applications have been limited to studying small wavelength ranges. This Letter shows that wideband operation can be achieved by combining techniques usually reserved for the communications community with that of cavity-enhanced spectroscopy, producing a multiplexed real-time cavity-enhanced spectrometer. We use multiple collinear laser sources operating asynchronously and simultaneously while being detected on a single photodetector. This is synonymous with radio frequency (RF) cellular systems in which signals are detected on a single antenna but decoded uniquely. Here, we demonstrate results with spectra of methyl salicylate and show parts-per-billion per root hertz sensitivity measured in real-time.
- 1 October 2015
- Published by Optica Publishing Group in Optics Letters
- Vol. 40 (19) , 4560-4562
Real-time multiplexed digital cavity-enhanced spectroscopy
Cavity-enhanced spectroscopy is a sensitive optical absorption technique but one where the practical applications have been limited to studying small wavelength ranges. This Letter shows that wideband operation can be achieved by combining techniques usually reserved for the communications community with that of cavity-enhanced spectroscopy, producing a multiplexed real-time cavity-enhanced spectrometer. We use multiple collinear laser sources operating asynchronously and simultaneously while being detected on a single photodetector. This is synonymous with radio frequency (RF) cellular systems in which signals are detected on a single antenna but decoded uniquely. Here, we demonstrate results with spectra of methyl salicylate and show parts-per-billion per root hertz sensitivity measured in real-time.
- 1 January 2015
- Published by Optica Publishing Group
- p. ATh1K.3
Advanced Wideband Cavity Enhanced Spectrosopy
We present new results from a variant of cavity enhanced spectroscopy that allows large spectral bandwidths to be analysed in real time, and demonstrate new methods to apply the technique to real-time monitoring of species with broad absorbances
- 1 January 2015
- Published by Optica Publishing Group
- p. ATh1K.3
Advanced Wideband Cavity Enhanced Spectrosopy
We present new results from a variant of cavity enhanced spectroscopy that allows large spectral bandwidths to be analysed in real time, and demonstrate new methods to apply the technique to real-time monitoring of species with broad absorbances
- Open Access
- 24 April 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (9) , 10519-10534
Pulsed quantum cascade laser based hypertemporal real-time headspace measurements
Optical cavity enhancement is a highly desirable process to make sensitive direct-absorption spectroscopic measurements of unknown substances, such as explosives, illicit material, or other species of interest. This paper reports advancements in the development of real-time cavity ringdown spectroscopy over a wide-bandwidth, with the aim to make headspace measurements of molecules at trace levels. We report results of two pulsed quantum cascade systems operating between (1200 to 1320)cm−1 and (1316 to 1613)cm−1 that measure the headspace of nitromethane, acetonitrile, acetone, and nitroglycerin, where the spectra are obtained in less than four seconds and contain at least 150,000 spectral wavelength datapoints.
- 24 April 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (9) , 10519-10534
Open AccessPulsed quantum cascade laser based hypertemporal real-time headspace measurements
Optical cavity enhancement is a highly desirable process to make sensitive direct-absorption spectroscopic measurements of unknown substances, such as explosives, illicit material, or other species of interest. This paper reports advancements in the development of real-time cavity ringdown spectroscopy over a wide-bandwidth, with the aim to make headspace measurements of molecules at trace levels. We report results of two pulsed quantum cascade systems operating between (1200 to 1320)cm−1 and (1316 to 1613)cm−1 that measure the headspace of nitromethane, acetonitrile, acetone, and nitroglycerin, where the spectra are obtained in less than four seconds and contain at least 150,000 spectral wavelength datapoints.
- 1 January 2014
- Published by Optica Publishing Group
- p. AW1P.1
Rapid, wideband cavity ringdown spectroscopy for the detection of explosives
We present results from a variant of CRDS that allows large spectral bandwidths to be analysed in real time. We have applied the technique to the analysis and detection of explosives and related compounds.
- 1 January 2014
- Published by Optica Publishing Group
- p. AW1P.1
Rapid, wideband cavity ringdown spectroscopy for the detection of explosives
We present results from a variant of CRDS that allows large spectral bandwidths to be analysed in real time. We have applied the technique to the analysis and detection of explosives and related compounds.
- 1 January 2014
- Published by Optica Publishing Group
- p. LW1D.5
Multiplexed Pulsed Quantum Cascade Laser Based Hypertemporal Real-time Headspace Measurements
Recent advances in digital signal processing have made it possible to make real-time hypertemporal spectroscopic measurements over several wavelength bands simultaneously. This talk will outline the progress made in this area of research and present a view of future application for this technology.
- 1 January 2014
- Published by Optica Publishing Group
- p. LW1D.5
Multiplexed Pulsed Quantum Cascade Laser Based Hypertemporal Real-time Headspace Measurements
Recent advances in digital signal processing have made it possible to make real-time hypertemporal spectroscopic measurements over several wavelength bands simultaneously. This talk will outline the progress made in this area of research and present a view of future application for this technology.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Rapid, wide bandwidth pulsed cavity ringdown spectroscopy in the mid infrared
We present a new variant of the Cavity Ringdown Spectroscopy (CRDS) that is able to scan across more than 1400 nm of spectral bandwidth around 6000 nm, acquiring and analysing more than 150,000 spectral datapoints in less than four seconds.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Rapid, wide bandwidth pulsed cavity ringdown spectroscopy in the mid infrared
We present a new variant of the Cavity Ringdown Spectroscopy (CRDS) that is able to scan across more than 1400 nm of spectral bandwidth around 6000 nm, acquiring and analysing more than 150,000 spectral datapoints in less than four seconds.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Kalman filter based estimation of decay time for a multimode optical cavity
We develop an extended Kalman filter to estimate the ring-down time of a multimode Fabry-Perot optical cavity with a pulse train input. First the extended Kalman filter is applied to data generated from a simulator to show that the estimate of the filter converges to the expected value of the ring-down time. It is also shown that the multimode filter improves the estimation performance, compared to a simplified filter designed from a single-mode model. Then the filter is applied to a set of experimentally obtained output intensity data.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Kalman filter based estimation of decay time for a multimode optical cavity
We develop an extended Kalman filter to estimate the ring-down time of a multimode Fabry-Perot optical cavity with a pulse train input. First the extended Kalman filter is applied to data generated from a simulator to show that the estimate of the filter converges to the expected value of the ring-down time. It is also shown that the multimode filter improves the estimation performance, compared to a simplified filter designed from a single-mode model. Then the filter is applied to a set of experimentally obtained output intensity data.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 75-79
Low pass filter model-based offline estimation of ring-down time for an experimental Fabry-Perot optical cavity
This paper presents offline extended Kalman filter (EKF) estimation results for the decay time-constant for an experimental Fabry-Perot optical cavity for cavity ring-down spectroscopy (CRDS). The decay time for an optical cavity is defined as the amount of time it takes for the light intensity inside the cavity to decay to 1/e times its original intensity in the absence of a sustained light source. An estimation of the decay time for a cavity depends upon the absorbing species inside the cavity along with other miscellaneous losses due to the elements used to construct the cavity. Once the miscellaneous losses are computed experimentally, the decay time due to the absorbing species can be directly computed. The decay rate, as a function of wavelength, can be used to identify trace gas elements such as chemicals and their compounds. For estimation purposes, the cavity is modeled as a low pass filter with unity DC gain and the experimentally obtained light intensity at the output of the cavity is used as measurement. During the process of recording the intensity data, the cavity's resonant frequency is held in sync with the input laser frequency via a proportional-integral (PI) controller. Finally, the estimation results for the decay time of the cavity using the low pass filter model presented in this paper, are compared with the estimation results using a quadrature model for the cavity from a previous work. The estimation results are also compared on filter execution times.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 75-79
Low pass filter model-based offline estimation of ring-down time for an experimental Fabry-Perot optical cavity
This paper presents offline extended Kalman filter (EKF) estimation results for the decay time-constant for an experimental Fabry-Perot optical cavity for cavity ring-down spectroscopy (CRDS). The decay time for an optical cavity is defined as the amount of time it takes for the light intensity inside the cavity to decay to 1/e times its original intensity in the absence of a sustained light source. An estimation of the decay time for a cavity depends upon the absorbing species inside the cavity along with other miscellaneous losses due to the elements used to construct the cavity. Once the miscellaneous losses are computed experimentally, the decay time due to the absorbing species can be directly computed. The decay rate, as a function of wavelength, can be used to identify trace gas elements such as chemicals and their compounds. For estimation purposes, the cavity is modeled as a low pass filter with unity DC gain and the experimentally obtained light intensity at the output of the cavity is used as measurement. During the process of recording the intensity data, the cavity's resonant frequency is held in sync with the input laser frequency via a proportional-integral (PI) controller. Finally, the estimation results for the decay time of the cavity using the low pass filter model presented in this paper, are compared with the estimation results using a quadrature model for the cavity from a previous work. The estimation results are also compared on filter execution times.