Jiyu Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jiyu Huang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Lin Guan
School of Electric Power, South China University of Technology, Guangzhou 510641, China
4 shared publications - Yinsheng Su
China Southern Power Grid Power Dispatching and Control Center, Guangzhou 510663, China
3 shared publications - Haicheng Yao
China Southern Power Grid,Dispatching Centre,Guangzhou,China
2 shared publications - Mengxuan Guo
School of Electric Power, South China University of Technology, Guangzhou, China
2 shared publications - Zhi Zhong
School of Electric Power, South China University of Technology, Guangzhou, China
2 shared publications Bingying Lin
1 shared publication
Latest Publications
- Open Access
- 18 December 2025
- Published by MDPI AG in Electronics
- Vol. 14 (24) , 4976
Enabling Fast Frequency Response with Adaptive Demand-Side Resource Control: Strategy and Field-Testing Validation
With the large-scale integration of new energy and power electronic devices into power systems, frequency stability has become an increasingly critical concern. To maintain frequency stability while mitigating the high capital expenditure of energy storage systems (ESSs), this paper develops a control framework centered on edge energy management terminals (EEMTs). The design is based on a demonstration project in which distributed energy resources (DERs) and flexible loads collaboratively provide frequency regulation. A monitoring station is implemented to make fast frequency response (FFR) resources dispatchable, detectable, measurable, and tradable. Furthermore, a control strategy tailored for building- and factory-level applications is proposed. This strategy enables real-time optimal scheduling of DERs and flexible loads through coordinated communication between EEMTs and net load units (NLUs). Two field tests further demonstrate the effectiveness and advantages of the proposed approach. In addition, this paper proposes a coordinated scheme in which wind farms and NLUs jointly participate in frequency regulation, aiming to mitigate the response delay of NLUs and the secondary frequency drop observed in wind farms. The feasibility and benefits of this scheme are validated through experimental tests.
- 18 December 2025
- Published by MDPI AG in Electronics
- Vol. 14 (24) , 4976
Open AccessEnabling Fast Frequency Response with Adaptive Demand-Side Resource Control: Strategy and Field-Testing Validation
With the large-scale integration of new energy and power electronic devices into power systems, frequency stability has become an increasingly critical concern. To maintain frequency stability while mitigating the high capital expenditure of energy storage systems (ESSs), this paper develops a control framework centered on edge energy management terminals (EEMTs). The design is based on a demonstration project in which distributed energy resources (DERs) and flexible loads collaboratively provide frequency regulation. A monitoring station is implemented to make fast frequency response (FFR) resources dispatchable, detectable, measurable, and tradable. Furthermore, a control strategy tailored for building- and factory-level applications is proposed. This strategy enables real-time optimal scheduling of DERs and flexible loads through coordinated communication between EEMTs and net load units (NLUs). Two field tests further demonstrate the effectiveness and advantages of the proposed approach. In addition, this paper proposes a coordinated scheme in which wind farms and NLUs jointly participate in frequency regulation, aiming to mitigate the response delay of NLUs and the secondary frequency drop observed in wind farms. The feasibility and benefits of this scheme are validated through experimental tests.
- Open Access
- 17 March 2025
- Published by MDPI AG in Electronics
- Vol. 14 (6) , 1180
Generator-Level Transient Stability Assessment in Power System Based on Graph Deep Learning with Sparse Hybrid Pooling
Aimed at increasingly challenging operation conditions in modern power systems, online pre-fault transient stability assessment (TSA) acts as a significant tool to detect latent stability risks and provide abundant generator-level information for preventive controls. Distinguished from “system-level” to describe terms concerning the whole system, here “generator-level” describes those concerning a generator. Due to poor topology-related expressive power, existing deep learning-based TSA methods can hardly predict generator-level stability indexes, unless they adopt the generator dynamics during and after faults by time-domain simulation (TDS) as the model input. This makes it difficult to fully leverage the speed advantages of deep learning. In this paper, we propose a generator-level TSA (GTSA) scheme based on topology-oriented graph deep learning which no longer requires time-domain simulation to provide the dynamic features. It integrates two modules to extract the network-dominated interaction trends from only the steady-state information. A sparse Edge Contraction-based Attention Pooling (ECAP) scheme is designed to dynamically simplify the network structure by feature aggregation, where the generator-specific information and key area features are kept. A Global Attention Pooling (GAP) module works to generate the interaction features among generators across the system. Hence, the constructed ECAP&GAP-GTSA scheme can not only output the system stability category but also provide the dominant generators and inter-generator oscillation severity. The performance as well as interpretability and generalization of our scheme are validated on the IEEE 39-bus system and the IEEE 300-bus system under various operation topologies and generator scales. The averaging inference time of a sample on the IEEE 39-bus system and IEEE 300-bus system is merely 1/671 and 1/149 of that of TDS, while the accuracy reaches about 99%.
- 17 March 2025
- Published by MDPI AG in Electronics
- Vol. 14 (6) , 1180
Open AccessGenerator-Level Transient Stability Assessment in Power System Based on Graph Deep Learning with Sparse Hybrid Pooling
Aimed at increasingly challenging operation conditions in modern power systems, online pre-fault transient stability assessment (TSA) acts as a significant tool to detect latent stability risks and provide abundant generator-level information for preventive controls. Distinguished from “system-level” to describe terms concerning the whole system, here “generator-level” describes those concerning a generator. Due to poor topology-related expressive power, existing deep learning-based TSA methods can hardly predict generator-level stability indexes, unless they adopt the generator dynamics during and after faults by time-domain simulation (TDS) as the model input. This makes it difficult to fully leverage the speed advantages of deep learning. In this paper, we propose a generator-level TSA (GTSA) scheme based on topology-oriented graph deep learning which no longer requires time-domain simulation to provide the dynamic features. It integrates two modules to extract the network-dominated interaction trends from only the steady-state information. A sparse Edge Contraction-based Attention Pooling (ECAP) scheme is designed to dynamically simplify the network structure by feature aggregation, where the generator-specific information and key area features are kept. A Global Attention Pooling (GAP) module works to generate the interaction features among generators across the system. Hence, the constructed ECAP&GAP-GTSA scheme can not only output the system stability category but also provide the dominant generators and inter-generator oscillation severity. The performance as well as interpretability and generalization of our scheme are validated on the IEEE 39-bus system and the IEEE 300-bus system under various operation topologies and generator scales. The averaging inference time of a sample on the IEEE 39-bus system and IEEE 300-bus system is merely 1/671 and 1/149 of that of TDS, while the accuracy reaches about 99%.
- 16 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (1) , 294-305
System-Scale-Free Transient Contingency Screening Scheme Based on Steady-State Information: A Pooling-Ensemble Multi-Graph Learning Approach
Data-driven transient stability assessment (TSA) models are usually sensitive to system scale changes and require dynamic information from time-domain simulation (TDS) as inputs. We propose a S ystem-sc A le- F re E T ransient C ontingency S creening (SAFE-TCS) scheme based on only the steady-state measurements. An analytical model is set up to estimate the state variation at fault occurrence ( $t_{0+}$ ) snapshot, which forms multi-graph inputs together with the steady-state information. A novel pooling-ensemble multi-attention graph convolutional network (PE-MAGCN) realizes the spatio-temporal graph embedding, in which an inter-graph convolution link works for the temporal abstraction. Following a pooling-ensemble mechanism, PE-MAGCN derives a fixed-size expressive vector for task-specific networks. This promotes the robustness of the model against system extension. The advantages of SAFE-TCS also benefit from the coordination of various training tricks, including channel attention, category-balanced sampling and joint-decoupling learning, etc. Test results on IEEE 39 Bus system and IEEE 300 Bus system indicate the superiority of the proposed scheme over existing models and its adaptability under various scenarios.
- 16 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (1) , 294-305
System-Scale-Free Transient Contingency Screening Scheme Based on Steady-State Information: A Pooling-Ensemble Multi-Graph Learning Approach
Data-driven transient stability assessment (TSA) models are usually sensitive to system scale changes and require dynamic information from time-domain simulation (TDS) as inputs. We propose a S ystem-sc A le- F re E T ransient C ontingency S creening (SAFE-TCS) scheme based on only the steady-state measurements. An analytical model is set up to estimate the state variation at fault occurrence ( $t_{0+}$ ) snapshot, which forms multi-graph inputs together with the steady-state information. A novel pooling-ensemble multi-attention graph convolutional network (PE-MAGCN) realizes the spatio-temporal graph embedding, in which an inter-graph convolution link works for the temporal abstraction. Following a pooling-ensemble mechanism, PE-MAGCN derives a fixed-size expressive vector for task-specific networks. This promotes the robustness of the model against system extension. The advantages of SAFE-TCS also benefit from the coordination of various training tricks, including channel attention, category-balanced sampling and joint-decoupling learning, etc. Test results on IEEE 39 Bus system and IEEE 300 Bus system indicate the superiority of the proposed scheme over existing models and its adaptability under various scenarios.
- Top Cited PapersOpen Access
- 29 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 93283-93296
Recurrent Graph Convolutional Network-Based Multi-Task Transient Stability Assessment Framework in Power System
Reliable online transient stability assessment (TSA) is fundamentally required for power system operation security. Compared with time-costly classical digital simulation methods, data-driven deep learning (DL) methods provide a promising technique to build a TSA model. However, general DL models show poor adaptability to the variation of power system topology. In this paper, we propose a new graph-based framework, which is termed as recurrent graph convolutional network based multi-task TSA (RGCN-MT-TSA). Both the graph convolutional network (GCN) and the long short-term memory (LSTM) unit are aggregated to form the recurrent graph convolutional network (RGCN), where the GCN explicitly integrate the bus (node) states with the topological characteristics while the LSTM subsequently captures the temporal features. We also propose a multi-task learning (MTL) scheme, which provides joint training of stability classification (Task-1) as well as critical generator identification (Task-2) in the framework, and accelerate the process with parallel computing. Test results on IEEE 39 Bus system and IEEE 300 Bus system indicate the superiority of the proposed scheme over existing models, as well as its robustness under various scenarios.
- 29 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 93283-93296
Top Cited PapersOpen AccessRecurrent Graph Convolutional Network-Based Multi-Task Transient Stability Assessment Framework in Power System
Reliable online transient stability assessment (TSA) is fundamentally required for power system operation security. Compared with time-costly classical digital simulation methods, data-driven deep learning (DL) methods provide a promising technique to build a TSA model. However, general DL models show poor adaptability to the variation of power system topology. In this paper, we propose a new graph-based framework, which is termed as recurrent graph convolutional network based multi-task TSA (RGCN-MT-TSA). Both the graph convolutional network (GCN) and the long short-term memory (LSTM) unit are aggregated to form the recurrent graph convolutional network (RGCN), where the GCN explicitly integrate the bus (node) states with the topological characteristics while the LSTM subsequently captures the temporal features. We also propose a multi-task learning (MTL) scheme, which provides joint training of stability classification (Task-1) as well as critical generator identification (Task-2) in the framework, and accelerate the process with parallel computing. Test results on IEEE 39 Bus system and IEEE 300 Bus system indicate the superiority of the proposed scheme over existing models, as well as its robustness under various scenarios.