JZJianjun Zheng

Jianjun Zheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jianjun Zheng has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Kuo Han

    Inner Mongolia Power (Group) Co., Ltd., Inner Mongolia Power Research Institute Branch, Hohhot 010020, China

    2 shared publications
  • Chengxin Liu

    Associated Engineering Research Center of Mechanics and Mechatronic Equipment, Shandong University, Weihai 264209, China

    1 shared publication
  • Hao Chen

    Inner Mongolia Power (Group) Co., Ltd., Inner Mongolia Power Research Institute Branch, Hohhot 010020, China

    1 shared publication
  • Hao Chen

    Key Laboratory of Experimental Marine Biology, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China; University of Chinese Academy of Sciences, Beijing 100049, China

    1 shared publication
  • Jiaqi Wang

    School of Renewable Energy, North China Electric Power University, Beijing 102206, China

    1 shared publication
  • Jun Lin

    School of New Energy, North China Electric Power University, Beijing, 102206, China

    1 shared publication

Latest Publications

  • Open Access

    Research status of creep damage evaluation methods for nickel-based high-temperature alloys

    by Jianjun Zheng, Yang Guo, Xiaomeng Tan

    Assessing the remaining life of key components in high temperature service is an essential element of strategic plant maintenance and plant life extension programs. Especially for nickel based high-temperature alloys, which are generally operated under service conditions above 600°C. In this paper, a number of techniques and methods for the creep damage evaluation methods have been introduced over past several decades. The application and limitation of several main approaches are discussed in detail. At last, some suggestions for the further research work are proposed.

  • Open Access

    Study on Cracking Causes of One 500 kV SSY Type Equipment Clamp

    by Jianjun Zheng, Yong Wei, Xiaokai Liu, Kuo Han

    One SSY type equipment clamp serviced in a 500 kV station was found to be cracked. In this paper, the crcaked cause and mechanism is investigated by means of macroscopic morphology observation, fracture surface morphology observation, X-ray digital detection, metallographic observation. The results indicated that the main reason for the fracture of the equipment clamp this time is that the terminal board is a cast part, which contains a large number of casting defects such as porosity and shrinkage, resulting in a decrease in its effective cross-sectional area and load-bearing capacity. In addition, insufficient modification treatment of the terminal board led to insufficient toughness due to needle or rod-shaped eutectic silicon in the organization. Finally, under the combined action of dynamic load and self weight caused by the swinging of the wire in the wind, the terminal board was brittle fractured along the bolt hole with obvious stress concentration effect.

  • Open Access

    Cause Analysis and Solutions About Abnormal Heating of Equipment Clamp

    by Jianjun Zheng, Zhehao Xu, Weiwei Gong

    As a kind of link terminal in power grid system, clamp has become one of the key components and widely used for connecting the transmission lines and electrical equipment. However, the joint between the tubular structure and the terminal plate or the drainage plate is always a weak part, which is easy to produce defects and then accelerate the failure of the clamp during service. This is also limited the use space of clamp to a certain extent. In this paper, research status on heating causes of equipment clamps and the corresponding solutions are mainly summarized. And the application of disc shape memory alloy gasket as well as the design of mortise tenon structure clamp will fundamentally solve the problem of abnormal heating of wire clamp.

  • Open Access

    Discussion on Causes and Solutions of the Biting Mechanism of Stainless Steel Bolts

    by Jianjun Zheng, Hao Chen, Yanfei Zhang

    Due to the influence of the peculiar material characteristics, austenitic stainless steel bolts are always easy to be locked during disassembly. This is not only seriously affected the service performance of austenitic stainless steel bolts, but also affects the reuse of bolts. In this paper, the main causes and mechanism of the locking of austenitic stainless steel blots in the process of fastening is summarized, and the effective measures containing correct material selection, carefully clean before assembly, spraying loosening agent, thermal expansion method, raw material belt tape winding and development of anti-locking austenitic stainless steel fastening bolt to prevent locking through theoretical analysis and experimental verification are also provided, which is hoped that certain guiding significance can be provided to prevent the phenomenon of bolt locking from the source as far as possible.

  • Open Access

    Corrosion Behavior and Microstructure of Cu-Based Composite Coatings Deposited by Cold Spraying

    by Hao Chen, Chengxin Liu, Xingrong Chu, Tao Zhang, Jianjun Zheng

    This study aimed to prepare Cu-based coatings with excellent corrosion resistance by cold spraying. Cu, Zn, and Al particles with different mass ratios were mechanically blended as the feedstock materials. The microstructure, element content, mechanical properties, and corrosion resistance of the coatings were investigated. Results showed that all the prepared coatings presented a dense microstructure. In addition, the thickness of the coatings exceeded 290 μm, and the existence of the “hammer effect” made the thickness and hardness of the coatings present an obvious negative correlation. Electrochemical test results indicated that changes in the element content could significantly affect the corrosion behavior of coatings. During the immersion period, the coatings containing Al exhibited better corrosion resistance.


  • Open Access

    Performance of Silicone Rubber Composites Filled with Aluminum Nitride and Alumina Tri-Hydrate

    by Jianjun Zheng, Shaojian He, Jiaqi Wang, Wenxuan Fang, Yang Xue, Liming Xie, Jun Lin

    In this study, silicone rubber (SR) composites were prepared with various amounts of aluminum nitride (AlN) and alumina tri-hydrate (ATH), and vinyl tri-methoxysilane (VTMS) was also introduced to prepare SR/ATH/AlN–VTMS composites for comparison. Compared to the SR/ATH composites, the SR/ATH/AlN composites with higher AlN loading exhibited higher breakdown strength and thermal conductivity, which were further improved by the addition of VTMS. Such results were related to the enhanced rubber–filler interfacial interactions from VTMS coupling, as demonstrated by scanning electron microscopy (SEM) analysis and the curing behaviors of the SR composites. Moreover, by replacing ATH with VTMS-coupled AlN, the SR/ATH/AlN–VTMS composites also exhibited lower dielectric loss along with an increased dielectric constant, suggesting the promising application of VTMS-coupled AlN as a filler for the preparation of the SR composites as high-voltage insulators.


  • Open Access

    Cause Analysis of the Crooked High Voltage End Fittings for a 220kV Composite Insulator in-service

    by Jianjun Zheng, Kuo Han, Yingjun Wang, Xianda Shi

    The high voltage end fitting for an in-serviced 220kV composite insulator was found to be crooked by the transmission line inspector, and the deformed cause was then investigated by digital X-ray imaging, chemical composition analysis, metallographic observation and mechanical properties testing in this paper. The results indicated that both the material quality and mechanical properties of the composite insulator high voltage (HV) end fitting met the standard requirements. And the main reason for the crooking of HV end fitting was the effect of abnormal force, such as falling from high position, impact of heavy objects. At last, it was advised that the supervision on the installation quality of fittings and the inspection of in-service composite insulator fittings should be strengthened. In addition, composite insulator with deformed or fractured end fitting should be timely handled, avoiding similar metal section failures.