Marta Guembe-García
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marta Guembe-García has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Jose Miguel Garcia
Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Burgos, Spain
6 shared publications - Lisa Rita Magnaghi
Dipartimento di Chimica Università degli Studi di Pavia Pavia Italy
6 shared publications - Raffaela Biesuz
Dipartimento di Chimica, Università degli Studi di Pavia, Viale Taramelli 12, 27100 Pavia, Italy
5 shared publications - Saúl Vallejos
Grupo de Polímeros, Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Bañuelos s/n, 09001 Burgos, Spain
5 shared publications Saturnino Ibeas
Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Banuelos s/n, 09001 Burgos, Spain
4 shared publicationsAna Arnaiz
Departamento de Química, Facultad de Ciencias, Universidad de Burgos, Plaza de Misael Banuelos s/n, 09001 Burgos, Spain
3 shared publications
Latest Publications
- Open Access
- 21 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (16) , 8311
Dual-Function DMG-Enriched Bioplastics for Nickel Release Assessment: From Solution-Phase Optimization to Solid-State Performance
Nickel release from metallic items is the leading cause of allergic contact dermatitis, and preventive strategies require both reliable detection tools and materials capable of limiting skin exposure. In this work, we propose dual-function bioplastic coatings based on starch, glycerol, and cellulose derivatives incorporating dimethylglyoxime (DMG) and a pH-10 borate buffer to enable colorimetric nickel sensing directly in the solid state. The Ni–DMG assay was first optimized in solution through UV-Vis spectroscopy and a Central Composite Face-Centered Design, identifying reagent concentrations that maximize linearity while minimizing detection limits. These conditions were transferred to bioplastic films prepared using carboxymethyl cellulose (CMC) or quaternized hydroxyethyl cellulose ethoxylate (QHECE). The materials were characterized by FT-IR spectroscopy and Principal Component Analysis, while gravimetric tests assessed hydrophilicity. Both bioplastics showed clear and reproducible colorimetric responses upon nickel exposure, and multivariate models built from RGB values and UV-Vis spectra enabled quantitative prediction of Ni2+ content. However, the proof-of-concept experiment revealed insufficient resistance to prolonged moisture, with films softening and partially losing cohesion under conditions mimicking skin perspiration. These results demonstrate that the sensing mechanism is robust, but the current bioplastic formulation requires improved water resistance before practical deployment as protective coatings for jewelry.
- 21 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (16) , 8311
Open AccessDual-Function DMG-Enriched Bioplastics for Nickel Release Assessment: From Solution-Phase Optimization to Solid-State Performance
Nickel release from metallic items is the leading cause of allergic contact dermatitis, and preventive strategies require both reliable detection tools and materials capable of limiting skin exposure. In this work, we propose dual-function bioplastic coatings based on starch, glycerol, and cellulose derivatives incorporating dimethylglyoxime (DMG) and a pH-10 borate buffer to enable colorimetric nickel sensing directly in the solid state. The Ni–DMG assay was first optimized in solution through UV-Vis spectroscopy and a Central Composite Face-Centered Design, identifying reagent concentrations that maximize linearity while minimizing detection limits. These conditions were transferred to bioplastic films prepared using carboxymethyl cellulose (CMC) or quaternized hydroxyethyl cellulose ethoxylate (QHECE). The materials were characterized by FT-IR spectroscopy and Principal Component Analysis, while gravimetric tests assessed hydrophilicity. Both bioplastics showed clear and reproducible colorimetric responses upon nickel exposure, and multivariate models built from RGB values and UV-Vis spectra enabled quantitative prediction of Ni2+ content. However, the proof-of-concept experiment revealed insufficient resistance to prolonged moisture, with films softening and partially losing cohesion under conditions mimicking skin perspiration. These results demonstrate that the sensing mechanism is robust, but the current bioplastic formulation requires improved water resistance before practical deployment as protective coatings for jewelry.
- Open Access
- 3 April 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (4) , 87
Correction: Guembe-Garcia et al. Multi-Way Data Analysis Nowadays: Taking Advanced Chemometric Tools to Everyday Analytical Chemistry Applications. Chemosensors 2026, 14, 37
- 3 April 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (4) , 87
Open AccessCorrection: Guembe-Garcia et al. Multi-Way Data Analysis Nowadays: Taking Advanced Chemometric Tools to Everyday Analytical Chemistry Applications. Chemosensors 2026, 14, 37
- Open Access
- 2 February 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (2) , 37
Multi-Way Data Analysis Nowadays: Taking Advanced Chemometric Tools to Everyday Analytical Chemistry Applications
Multi-way analysis has become one of the most powerful and versatile chemometric approaches for dealing with the increasing complexity of data generated in modern analytical chemistry. Advances in instrumentation, the widespread use of hyphenated techniques, and the inherently multidimensional nature of many experimental designs require methods capable of preserving structural relationships within datasets. In this context, multi-way tools such as Tucker 3, PARAFAC, or other supervised variants provide rigorous and interpretable descriptions of variability across multiple modes (samples, variables, conditions), enabling the extraction of meaningful patterns, improved noise handling, and enhanced robustness, compared with traditional bilinear approaches. This review offers a critical overview of the most commonly applied multi-way algorithms and their practical use in fields such as environmental chemistry, food science, clinical diagnostics, industrial process monitoring, and pharmaceutical analysis. The essential steps of the workflow, from data acquisition and preprocessing to model selection and interpretation, are discussed, highlighting their impact on model reliability. A dedicated section summarizes the software environments available for performing multi-way analyses, guiding readers in selecting the most suitable tools for their needs. Overall, this review emphasizes how multi-way chemometrics is becoming increasingly crucial for converting complex, high-dimensional data into reliable and actionable chemical knowledge.
- 2 February 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (2) , 37
Open AccessMulti-Way Data Analysis Nowadays: Taking Advanced Chemometric Tools to Everyday Analytical Chemistry Applications
Multi-way analysis has become one of the most powerful and versatile chemometric approaches for dealing with the increasing complexity of data generated in modern analytical chemistry. Advances in instrumentation, the widespread use of hyphenated techniques, and the inherently multidimensional nature of many experimental designs require methods capable of preserving structural relationships within datasets. In this context, multi-way tools such as Tucker 3, PARAFAC, or other supervised variants provide rigorous and interpretable descriptions of variability across multiple modes (samples, variables, conditions), enabling the extraction of meaningful patterns, improved noise handling, and enhanced robustness, compared with traditional bilinear approaches. This review offers a critical overview of the most commonly applied multi-way algorithms and their practical use in fields such as environmental chemistry, food science, clinical diagnostics, industrial process monitoring, and pharmaceutical analysis. The essential steps of the workflow, from data acquisition and preprocessing to model selection and interpretation, are discussed, highlighting their impact on model reliability. A dedicated section summarizes the software environments available for performing multi-way analyses, guiding readers in selecting the most suitable tools for their needs. Overall, this review emphasizes how multi-way chemometrics is becoming increasingly crucial for converting complex, high-dimensional data into reliable and actionable chemical knowledge.
- Open Access
- 11 June 2025
- Published by Elsevier in Dyes and Pigments
- Vol. 242
Intrinsically magenta-colored aramids with enhanced mechanical performance
- 11 June 2025
- Published by Elsevier in Dyes and Pigments
- Vol. 242
Open AccessIntrinsically magenta-colored aramids with enhanced mechanical performance
- Open Access
- 29 January 2025
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 332, 125821
Albumin quantification by alternative chemometric-assisted dye-binding methods robust towards pH and ionic strength variations
- 29 January 2025
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 332, 125821
Open AccessAlbumin quantification by alternative chemometric-assisted dye-binding methods robust towards pH and ionic strength variations
- Open Access
Chemometric-Assisted Litmus Test: One Single Sensing Platform Adapted from 1–13 to Narrow pH Ranges
A novel 3 × 4 colorimetric sensing platform, named the chemometric-assisted litmus test (CLT), has been developed by covalently anchoring commercial pH indicators to ethylene vinyl alcohol (EVOH). The proposed device can be exploited for pH determinations in a wide range from 1 to 13 and in specific narrow ranges, achieving sufficient accuracy and errors below 0.5 pH units. The experimental procedure is simple, quick and reliable; equilibration is reached in less than 2 h, CLT pictures are acquired by a camera, and data treatment is performed applying chemometric techniques such as principal component analysis (PCA) and partial least square regression (PLS) to RGB indices.
Open AccessChemometric-Assisted Litmus Test: One Single Sensing Platform Adapted from 1–13 to Narrow pH Ranges
A novel 3 × 4 colorimetric sensing platform, named the chemometric-assisted litmus test (CLT), has been developed by covalently anchoring commercial pH indicators to ethylene vinyl alcohol (EVOH). The proposed device can be exploited for pH determinations in a wide range from 1 to 13 and in specific narrow ranges, achieving sufficient accuracy and errors below 0.5 pH units. The experimental procedure is simple, quick and reliable; equilibration is reached in less than 2 h, CLT pictures are acquired by a camera, and data treatment is performed applying chemometric techniques such as principal component analysis (PCA) and partial least square regression (PLS) to RGB indices.
- Open Access
- 15 December 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 379, 133165
Lab-on-a-chip for the easy and visual detection of SARS-CoV-2 in saliva based on sensory polymers
- 15 December 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 379, 133165
Open AccessLab-on-a-chip for the easy and visual detection of SARS-CoV-2 in saliva based on sensory polymers
- Open Access
- 8 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (24) , 16488
Potentiometric MIP-Modified Screen-Printed Cell for Phenoxy Herbicides Detection
In this study, a molecularly imprinted polymer (MIP)-based screen-printed cell is developed for detecting phenoxy herbicides using 2-methyl-4-chlorophenoxyacetic acid (MCPA) as the template. MCPA is a phenoxy herbicide widely used since 1945 to control broadleaf weeds via growth regulation, primarily in pasture and cereal crops. The potentiometric cell consists of a silver/silver chloride pseudo-reference electrode and a graphite working electrode coated with a MIP film. The polymeric layer is thermally formed after drop-coating of a pre-polymeric mixture composed of the reagents at the following molar ratio: 1 MCPA: 15 MAA (methacrylic acid): 7 EGDMA (ethylene glycol dimethacrylate). After template removal, the recognition cavities function as the ionophore of a classical ion selective electrode (ISE) membrane. The detected ion is the deprotonated MCPA specie, negatively charged, so the measurements were performed in phosphate buffer at pH 5.5. A linear decrease of the potential with MCPA concentration, ranging from 4 × 10−8 to 1 × 10−6 mol L−1, was obtained. The detection limit and the limit of quantification were, respectively, 10 nmol L−1 and 40 nmol L−1. A Nernstian slope of about −59 mV/dec was achieved. The method has precision and LOD required for MCPA determination in contaminated environmental samples.
- 8 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (24) , 16488
Open AccessPotentiometric MIP-Modified Screen-Printed Cell for Phenoxy Herbicides Detection
In this study, a molecularly imprinted polymer (MIP)-based screen-printed cell is developed for detecting phenoxy herbicides using 2-methyl-4-chlorophenoxyacetic acid (MCPA) as the template. MCPA is a phenoxy herbicide widely used since 1945 to control broadleaf weeds via growth regulation, primarily in pasture and cereal crops. The potentiometric cell consists of a silver/silver chloride pseudo-reference electrode and a graphite working electrode coated with a MIP film. The polymeric layer is thermally formed after drop-coating of a pre-polymeric mixture composed of the reagents at the following molar ratio: 1 MCPA: 15 MAA (methacrylic acid): 7 EGDMA (ethylene glycol dimethacrylate). After template removal, the recognition cavities function as the ionophore of a classical ion selective electrode (ISE) membrane. The detected ion is the deprotonated MCPA specie, negatively charged, so the measurements were performed in phosphate buffer at pH 5.5. A linear decrease of the potential with MCPA concentration, ranging from 4 × 10−8 to 1 × 10−6 mol L−1, was obtained. The detection limit and the limit of quantification were, respectively, 10 nmol L−1 and 40 nmol L−1. A Nernstian slope of about −59 mV/dec was achieved. The method has precision and LOD required for MCPA determination in contaminated environmental samples.
- Open Access
- 3 August 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (32) , 37051-37058
Easy Nitrite Analysis of Processed Meat with Colorimetric Polymer Sensors and a Smartphone App
We have developed an in situ methodology for determining nitrite concentration in processed meats that can also be used by unskilled personnel. It is based on a colorimetric film-shaped sensory polymer that changes its color upon contacting the meat and a mobile app that automatically calculates the manufacturing and residual nitrite concentration by only taking digital photographs of sensory films and analyzing digital color parameters. The film-shaped polymer sensor detects nitrite anions by an azo-coupling reaction, since they activate this reaction between two of the four monomers that the copolymer is based on. The sensory polymer is complemented with an app, which analyzes the color in two different digital color spaces (RGB and HSV) and performs a set of 32 data fittings representing the concentration of nitrite versus eight different variables, finally providing the nitrite concentration of the test samples using the best fitting curve. The calculated concentration of nitrite correlates with a validated method (ISO 2918: 1975) usually used to determine nitrite, and no statistically significant difference between these methods and our proposed one has been found in our study (26 meat samples, 8 prepared, and 18 commercial). Our method represents a great advance in terms of analysis time, simplicity, and orientation to use by average citizens.
- 3 August 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (32) , 37051-37058
Open AccessEasy Nitrite Analysis of Processed Meat with Colorimetric Polymer Sensors and a Smartphone App
We have developed an in situ methodology for determining nitrite concentration in processed meats that can also be used by unskilled personnel. It is based on a colorimetric film-shaped sensory polymer that changes its color upon contacting the meat and a mobile app that automatically calculates the manufacturing and residual nitrite concentration by only taking digital photographs of sensory films and analyzing digital color parameters. The film-shaped polymer sensor detects nitrite anions by an azo-coupling reaction, since they activate this reaction between two of the four monomers that the copolymer is based on. The sensory polymer is complemented with an app, which analyzes the color in two different digital color spaces (RGB and HSV) and performs a set of 32 data fittings representing the concentration of nitrite versus eight different variables, finally providing the nitrite concentration of the test samples using the best fitting curve. The calculated concentration of nitrite correlates with a validated method (ISO 2918: 1975) usually used to determine nitrite, and no statistically significant difference between these methods and our proposed one has been found in our study (26 meat samples, 8 prepared, and 18 commercial). Our method represents a great advance in terms of analysis time, simplicity, and orientation to use by average citizens.
- Open Access
- 25 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-12
The role of polymeric chains as a protective environment for improving the stability and efficiency of fluorogenic peptide substrates
We have faced the preparation of fully water-soluble fluorescent peptide substrate with long-term environmental stability (in solution more than 35 weeks) and, accordingly, with stable results in the use of this probe in determining the activity of enzymes. We have achieved this goal by preparing a co-polymer of the commercial N-vinyl-2-pyrrolidone (99.5% mol) and a fluorescent substrate for trypsin activity determination having a vinylic group (0.5%). The activity of trypsin has been measured in water solutions of this polymer over time, contrasted against the activity of both the commercial substrate Z-L-Arg-7-amido-4-methylcoumarin hydrochloride and its monomeric derivative, prepared ad-hoc. Initially, the activity of the sensory polymer was 74.53 ± 1.72 nmol/min/mg of enzyme, while that of the commercial substrate was 20.44 ± 0.65 nmol/min/mg of enzyme, the former maintained stable along weeks and the latter with a deep decay to zero in three weeks. The ‘protection’ effect exerted by the polymer chain has been studied by solvation studies by UV–Vis spectroscopy, steady-state & time resolved fluorescence, thermogravimetry and isothermal titration calorimetry.
- 25 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-12
Open AccessThe role of polymeric chains as a protective environment for improving the stability and efficiency of fluorogenic peptide substrates
We have faced the preparation of fully water-soluble fluorescent peptide substrate with long-term environmental stability (in solution more than 35 weeks) and, accordingly, with stable results in the use of this probe in determining the activity of enzymes. We have achieved this goal by preparing a co-polymer of the commercial N-vinyl-2-pyrrolidone (99.5% mol) and a fluorescent substrate for trypsin activity determination having a vinylic group (0.5%). The activity of trypsin has been measured in water solutions of this polymer over time, contrasted against the activity of both the commercial substrate Z-L-Arg-7-amido-4-methylcoumarin hydrochloride and its monomeric derivative, prepared ad-hoc. Initially, the activity of the sensory polymer was 74.53 ± 1.72 nmol/min/mg of enzyme, while that of the commercial substrate was 20.44 ± 0.65 nmol/min/mg of enzyme, the former maintained stable along weeks and the latter with a deep decay to zero in three weeks. The ‘protection’ effect exerted by the polymer chain has been studied by solvation studies by UV–Vis spectroscopy, steady-state & time resolved fluorescence, thermogravimetry and isothermal titration calorimetry.