Chintan Savla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chintan Savla has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Andre Francis Palmer
The Ohio State University
6 shared publications Andre F. Palmer
William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio 43210, United States
5 shared publications- Carlos Jose Munoz
Department of Bioengineering, University of California San Diego, La Jolla, CA
4 shared publications - Ivan Susin Pires
Koch Institute for Integrative Cancer Research Massachusetts Institute of Technology 500 Main Street Cambridge MA 02139 USA
4 shared publications - Pedro Cabrales
University of California San Diego
4 shared publications - Xiangming Gu
William G. Lowrie Department of Chemical and Biomolecular Engineering The Ohio State University Columbus Ohio USA
2 shared publications
Latest Publications
- 5 July 2024
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 7 (8) , 5188-5200
Degree of PEGylatation of Lumbricus terrestris Hemoglobin Improves Microcirculatory Blood Flow but Increases the Rate of Auto-Oxidation
The demand for red blood cells (RBCs) is on the rise due to the increasing diagnosis of chronic diseases such as sickle cell anemia, malaria, and thalassemia. Despite many commercial attempts, there are no U.S. FDA-approved artificial RBCs for use in humans. Existing RBC substitutes have employed various strategies to transport oxygen, extend the circulation time, and reduce organ toxicity, but none have replicated the natural protective mechanisms of RBCs, which prevent hemoglobin (Hb) dimerization and heme iron oxidation. Lumbricus terrestris (earthworm) erythrocruorin (LtEc) is a naturally occurring extracellular hemoglobin (Hb) with promising attributes: large molecular diameter (30 nm), high molecular weight (3.6 MDa), low auto-oxidation rate, and limited nitric oxide-scavenging properties. These characteristics make LtEc an ideal candidate as an RBC substitute. However, LtEc has a significant drawback, its short circulatory half-life. To address this issue, we explored thiol-mediated surface PEGylation of LtEc (PEG-LtEc) at varying polyethylene glycol (PEG) surface coverages. Increasing PEG surface coverage beyond 40% destabilizes LtEc into smaller subunits that are 1/12th the size of LtEc. Therefore, we evaluated two PEG surface coverage options: PEG-LtEc-0.2 (20% PEGylation) and PEG-LtEc-1.0 (100% PEGylation). We conducted experiments using golden Syrian hamsters with dorsal window chambers and catheters to assess the efficacy of these solutions. We measured microvascular parameters, organ function, cerebral blood flow, circulation time, mean arterial pressure, heart rate, and blood gases and performed histology to screen for toxicity. Our findings indicate that both PEG-LtEc molecules offer significant benefits in restoring microvascular parameters, organ function, cerebral blood flow, and circulation time compared to LtEc alone. Notably, PEG-LtEc-1.0 showed superior microvascular perfusion, although it exhibited a higher rate of auto-oxidation compared to PEG-LtEc-0.2. These results underscore the advantages of PEGylation in terms of tissue perfusion and organ health while highlighting its limitations.
- 5 July 2024
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 7 (8) , 5188-5200
Degree of PEGylatation of Lumbricus terrestris Hemoglobin Improves Microcirculatory Blood Flow but Increases the Rate of Auto-Oxidation
The demand for red blood cells (RBCs) is on the rise due to the increasing diagnosis of chronic diseases such as sickle cell anemia, malaria, and thalassemia. Despite many commercial attempts, there are no U.S. FDA-approved artificial RBCs for use in humans. Existing RBC substitutes have employed various strategies to transport oxygen, extend the circulation time, and reduce organ toxicity, but none have replicated the natural protective mechanisms of RBCs, which prevent hemoglobin (Hb) dimerization and heme iron oxidation. Lumbricus terrestris (earthworm) erythrocruorin (LtEc) is a naturally occurring extracellular hemoglobin (Hb) with promising attributes: large molecular diameter (30 nm), high molecular weight (3.6 MDa), low auto-oxidation rate, and limited nitric oxide-scavenging properties. These characteristics make LtEc an ideal candidate as an RBC substitute. However, LtEc has a significant drawback, its short circulatory half-life. To address this issue, we explored thiol-mediated surface PEGylation of LtEc (PEG-LtEc) at varying polyethylene glycol (PEG) surface coverages. Increasing PEG surface coverage beyond 40% destabilizes LtEc into smaller subunits that are 1/12th the size of LtEc. Therefore, we evaluated two PEG surface coverage options: PEG-LtEc-0.2 (20% PEGylation) and PEG-LtEc-1.0 (100% PEGylation). We conducted experiments using golden Syrian hamsters with dorsal window chambers and catheters to assess the efficacy of these solutions. We measured microvascular parameters, organ function, cerebral blood flow, circulation time, mean arterial pressure, heart rate, and blood gases and performed histology to screen for toxicity. Our findings indicate that both PEG-LtEc molecules offer significant benefits in restoring microvascular parameters, organ function, cerebral blood flow, and circulation time compared to LtEc alone. Notably, PEG-LtEc-1.0 showed superior microvascular perfusion, although it exhibited a higher rate of auto-oxidation compared to PEG-LtEc-0.2. These results underscore the advantages of PEGylation in terms of tissue perfusion and organ health while highlighting its limitations.
- 7 April 2023
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 24 (5) , 2022-2029
Photocatalytic Synthesis of a Polydopamine-Coated Acellular Mega-Hemoglobin as a Potential Oxygen Therapeutic with Antioxidant Properties
Hemoglobin-based oxygen carriers (HBOCs) are being developed to overcome limitations associated with transfusion of donated red blood cells (RBCs) such as potential transmission of blood-borne pathogens and limited ex vivo storage shelf-life. Annelid erythrocruorin (Ec) derived from the worm Lumbricus terrestris (Lt) is an acellular mega-hemoglobin that has shown promise as a potential HBOC due to the large size of its oligomeric structure, thus overcoming limitations of unmodified circulating cell-free hemoglobin (Hb). With a large molecular weight of 3.6 MDa compared to 64.5 kDa for human Hb (hHb) and 144 oxygen-binding globin subunits compared to the 4 globin subunits of hHb, LtEc does not extravasate from the circulation to the same extent as hHb. LtEc is stable in the circulation without RBC membrane encapsulation and has a lower rate of auto-oxidation compared to acellular hHb, which allows the protein to remain functional for longer periods of time in the circulation compared to HBOCs derived from mammalian Hbs. Surface coatings, such as poly(ethylene glycol) (PEG) and oxidized dextran (Odex), have been investigated to potentially reduce the immune response and improve the circulation time of LtEc in vivo. Polydopamine (PDA) is a hydrophilic, biocompatible, bioinspired polymer coating used for biomedical nanoparticle assemblies and coatings and has previously been investigated for the surface coating of hHb. PDA is typically synthesized via the self-polymerization of dopamine (DA) under alkaline (pH > 8.0) conditions. However, at pH > 8.0, the oligomeric structure of LtEc begins to dissociate. Therefore, in this study, we investigated a photocatalytic method of PDA polymerization on the surface of LtEc using 9-mesityl-10-methylacridinium tetrafluoroborate (Acr-Mes) to drive PDA polymerization under physiological conditions (pH 7.4, 25 °C) over 2, 5, and 16 h in order to preserve the size and structure of LtEc. The resulting structural, biophysical, and antioxidant properties of PDA surface-coated LtEc (PDA-LtEc) was characterized using various techniques. PDA-LtEc showed an increase in measured particle size, molecular weight, and surface ζ-potential with increasing reaction time from t = 2 to 16 h compared to unmodified LtEc. PDA-LtEc reacted for 16 h was found to have reduced oxygen-binding cooperativity and slower deoxygenation kinetics compared to PDA-LtEc with lower levels of polymerization (t = 2 h), but there was no statistically significant difference in oxygen affinity. The thickness of the PDA coating can be controlled and in turn the biophysical properties can be tuned by changing various reaction conditions. PDA-LtEc was shown to demonstrate an increased level of antioxidant capacity (ferric iron reduction and free-radical scavenging) when synthesized at a reaction time of t = 16 h compared to LtEc. These antioxidant properties may prove beneficial for oxidative protection of PDA-LtEc during its time in the circulation. Hence, we believe that PDA-LtEc is a promising oxygen therapeutic for potential use in transfusion medicine applications.
- 7 April 2023
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 24 (5) , 2022-2029
Photocatalytic Synthesis of a Polydopamine-Coated Acellular Mega-Hemoglobin as a Potential Oxygen Therapeutic with Antioxidant Properties
Hemoglobin-based oxygen carriers (HBOCs) are being developed to overcome limitations associated with transfusion of donated red blood cells (RBCs) such as potential transmission of blood-borne pathogens and limited ex vivo storage shelf-life. Annelid erythrocruorin (Ec) derived from the worm Lumbricus terrestris (Lt) is an acellular mega-hemoglobin that has shown promise as a potential HBOC due to the large size of its oligomeric structure, thus overcoming limitations of unmodified circulating cell-free hemoglobin (Hb). With a large molecular weight of 3.6 MDa compared to 64.5 kDa for human Hb (hHb) and 144 oxygen-binding globin subunits compared to the 4 globin subunits of hHb, LtEc does not extravasate from the circulation to the same extent as hHb. LtEc is stable in the circulation without RBC membrane encapsulation and has a lower rate of auto-oxidation compared to acellular hHb, which allows the protein to remain functional for longer periods of time in the circulation compared to HBOCs derived from mammalian Hbs. Surface coatings, such as poly(ethylene glycol) (PEG) and oxidized dextran (Odex), have been investigated to potentially reduce the immune response and improve the circulation time of LtEc in vivo. Polydopamine (PDA) is a hydrophilic, biocompatible, bioinspired polymer coating used for biomedical nanoparticle assemblies and coatings and has previously been investigated for the surface coating of hHb. PDA is typically synthesized via the self-polymerization of dopamine (DA) under alkaline (pH > 8.0) conditions. However, at pH > 8.0, the oligomeric structure of LtEc begins to dissociate. Therefore, in this study, we investigated a photocatalytic method of PDA polymerization on the surface of LtEc using 9-mesityl-10-methylacridinium tetrafluoroborate (Acr-Mes) to drive PDA polymerization under physiological conditions (pH 7.4, 25 °C) over 2, 5, and 16 h in order to preserve the size and structure of LtEc. The resulting structural, biophysical, and antioxidant properties of PDA surface-coated LtEc (PDA-LtEc) was characterized using various techniques. PDA-LtEc showed an increase in measured particle size, molecular weight, and surface ζ-potential with increasing reaction time from t = 2 to 16 h compared to unmodified LtEc. PDA-LtEc reacted for 16 h was found to have reduced oxygen-binding cooperativity and slower deoxygenation kinetics compared to PDA-LtEc with lower levels of polymerization (t = 2 h), but there was no statistically significant difference in oxygen affinity. The thickness of the PDA coating can be controlled and in turn the biophysical properties can be tuned by changing various reaction conditions. PDA-LtEc was shown to demonstrate an increased level of antioxidant capacity (ferric iron reduction and free-radical scavenging) when synthesized at a reaction time of t = 16 h compared to LtEc. These antioxidant properties may prove beneficial for oxidative protection of PDA-LtEc during its time in the circulation. Hence, we believe that PDA-LtEc is a promising oxygen therapeutic for potential use in transfusion medicine applications.
- Open Access
- 26 September 2022
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 119 (12) , 3612-3622
Scalable manufacturing platform for the production of PEGylated heme albumin
Cell‐free heme, which was previously shown to have adverse effects on the innate immune system, does not induce inflammation when bound to a protein carrier via overexpression of the enzyme heme‐oxygenase 1 (HO‐1). Studies in mouse macrophage cell culture and human endothelial cells have confirmed HO‐1 catalyzed breakdown of protein bound heme into biliverdin, iron, and carbon monoxide (CO), which elicits anti‐inflammatory effects. However, to fully realize the anti‐inflammatory therapeutic effects of heme, a colloidally stable heme protein carrier must be developed. To accomplish this goal, we incorporated multiple heme molecules into human serum albumin (HSA) via partial unfolding of HSA at basic pH followed by refolding at neutral pH, and subsequently conjugated the surface of the heme‐HSA complex with polyethylene glycol (PEG) to stabilize heme‐HSA. Quantification studies confirmed that a maximum of 5−6 hemes could be bound to HSA without precipitation or degradation of heme‐HSA. Dynamic light scattering, size exclusion‐high performance liquid chromatography (SEC‐HPLC), and matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry confirmed the increase in hydrodynamic diameter and molecular weight (MW), respectively, upon PEGylation of heme‐HSA. Furthermore, PEG‐heme‐HSA was stable upon exposure to different pH environments, freeze‐thaw cycles, and storage at 4°C. Taken together, we devised a synthesis and purification platform for the production of PEGylated heme‐incorporated HSA that can be used to test the potential anti‐inflammatory effects of heme in vivo.
- 26 September 2022
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 119 (12) , 3612-3622
Open AccessScalable manufacturing platform for the production of PEGylated heme albumin
Cell‐free heme, which was previously shown to have adverse effects on the innate immune system, does not induce inflammation when bound to a protein carrier via overexpression of the enzyme heme‐oxygenase 1 (HO‐1). Studies in mouse macrophage cell culture and human endothelial cells have confirmed HO‐1 catalyzed breakdown of protein bound heme into biliverdin, iron, and carbon monoxide (CO), which elicits anti‐inflammatory effects. However, to fully realize the anti‐inflammatory therapeutic effects of heme, a colloidally stable heme protein carrier must be developed. To accomplish this goal, we incorporated multiple heme molecules into human serum albumin (HSA) via partial unfolding of HSA at basic pH followed by refolding at neutral pH, and subsequently conjugated the surface of the heme‐HSA complex with polyethylene glycol (PEG) to stabilize heme‐HSA. Quantification studies confirmed that a maximum of 5−6 hemes could be bound to HSA without precipitation or degradation of heme‐HSA. Dynamic light scattering, size exclusion‐high performance liquid chromatography (SEC‐HPLC), and matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry confirmed the increase in hydrodynamic diameter and molecular weight (MW), respectively, upon PEGylation of heme‐HSA. Furthermore, PEG‐heme‐HSA was stable upon exposure to different pH environments, freeze‐thaw cycles, and storage at 4°C. Taken together, we devised a synthesis and purification platform for the production of PEGylated heme‐incorporated HSA that can be used to test the potential anti‐inflammatory effects of heme in vivo.
- Open Access
- 17 February 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (2) , e0263996
Lyophilized annelid mega-hemoglobin retains its’ quaternary structure and oxygen equilibrium properties after room temperature storage for over 6 months
The long-term storage stability and portability of hemoglobin (Hb)-based oxygen carriers are important design criteria in the development of these therapeutics. Lyophilization or storing proteins in a freeze-dried form is known to increase storage lifetime and reduce overall weight. In this study, we lyophilized the extracellular mega-hemoglobin of the annelid Lumbricus terrestris and tested the storage stability at different temperatures and oxygenation conditions. Storage in refrigerated conditions for over 6 months in the presence of N2 reduced oxidation by 50% while storage at room temperature in the presence of N2 reduced oxidation by 60%, all while maintaining the structural stability of the mega-hemoglobin. We also demonstrated a reliable strategy to freeze dry Hbs in the presence of a minimally non-reducing disaccharide sugar that could be easily re-solubilized in deionized water. Overall, this study made significant advances towards long term storage stability of oxygen therapeutics for direct applications in transfusion medicine.
- 17 February 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (2) , e0263996
Open AccessLyophilized annelid mega-hemoglobin retains its’ quaternary structure and oxygen equilibrium properties after room temperature storage for over 6 months
The long-term storage stability and portability of hemoglobin (Hb)-based oxygen carriers are important design criteria in the development of these therapeutics. Lyophilization or storing proteins in a freeze-dried form is known to increase storage lifetime and reduce overall weight. In this study, we lyophilized the extracellular mega-hemoglobin of the annelid Lumbricus terrestris and tested the storage stability at different temperatures and oxygenation conditions. Storage in refrigerated conditions for over 6 months in the presence of N2 reduced oxidation by 50% while storage at room temperature in the presence of N2 reduced oxidation by 60%, all while maintaining the structural stability of the mega-hemoglobin. We also demonstrated a reliable strategy to freeze dry Hbs in the presence of a minimally non-reducing disaccharide sugar that could be easily re-solubilized in deionized water. Overall, this study made significant advances towards long term storage stability of oxygen therapeutics for direct applications in transfusion medicine.
- 21 October 2021
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 119 (1) , 176-186
Tangential flow filtration facilitated fractionation and PEGylation of low and high‐molecular weight polymerized hemoglobins and their biophysical properties
Various types of hemoglobin (Hb)‐based oxygen carriers (HBOCs) have been developed as red blood cell substitutes for treating blood loss when blood is not available. Among those HBOCs, glutaraldehyde polymerized Hbs have attracted significant attention due to their facile synthetic route, and ability to expand the blood volume and deliver oxygen. Hemopure®, Oxyglobin®, and PolyHeme® are the most well‐known commercially developed glutaraldehyde polymerized Hbs. Unfortunately, only Oxyglobin® was approved by the FDA for veterinary use in the United States, while Hemopure® and PolyHeme® failed phase III clinical trials due to their ability to extravasate from the blood volume into the tissue space which facilitated nitric oxide scavenging and tissue deposition of iron, which elicited vasoconstriction, hypertension and oxidative tissue injury. Fortunately, conjugation of poly (ethylene glycol) (PEG) on the surface of Hb is capable of reducing the vasoactivity of Hb by creating a hydration layer surrounding the Hb molecule, which increases its hydrodynamic diameter and reduces tissue extravasation. Several commercial PEGylated Hbs (MP4®, Sanguinate®, Euro‐PEG‐Hb) have been developed for clinical use with a longer circulatory half‐life and improved safety compared to Hb. However, all of these commercial products exhibited relatively high oxygen affinity compared to Hb, which limited their clinical use. To dually address the limitations of prior generations of polymerized and PEGylated Hbs, this current study describes the PEGylation of polymerized bovine Hb (PEG‐PolybHb) in both the tense (T) and relaxed (R) quaternary state via thiol‐maleimide chemistry to produce an HBOC with low or high oxygen affinity. The biophysical properties of PEG‐PolybHb were measured and compared with those of commercial polymerized and PEGylated HBOCs. T‐state PEG‐PolybHb possessed higher hydrodynamic volume and P50 than previous generations of commercial PEGylated Hbs. Both T‐ and R‐state PEG‐PolybHb exhibited significantly lower haptoglobin binding rates than the precursor PolybHb, indicating potentially reduced clearance by CD163 + monocytes and macrophages. Thus, T‐state PEG‐PolybHb is expected to function as a promising HBOC due to its low oxygen affinity and enhanced stealth properties afforded by the PEG hydration shell.
- 21 October 2021
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 119 (1) , 176-186
Tangential flow filtration facilitated fractionation and PEGylation of low and high‐molecular weight polymerized hemoglobins and their biophysical properties
Various types of hemoglobin (Hb)‐based oxygen carriers (HBOCs) have been developed as red blood cell substitutes for treating blood loss when blood is not available. Among those HBOCs, glutaraldehyde polymerized Hbs have attracted significant attention due to their facile synthetic route, and ability to expand the blood volume and deliver oxygen. Hemopure®, Oxyglobin®, and PolyHeme® are the most well‐known commercially developed glutaraldehyde polymerized Hbs. Unfortunately, only Oxyglobin® was approved by the FDA for veterinary use in the United States, while Hemopure® and PolyHeme® failed phase III clinical trials due to their ability to extravasate from the blood volume into the tissue space which facilitated nitric oxide scavenging and tissue deposition of iron, which elicited vasoconstriction, hypertension and oxidative tissue injury. Fortunately, conjugation of poly (ethylene glycol) (PEG) on the surface of Hb is capable of reducing the vasoactivity of Hb by creating a hydration layer surrounding the Hb molecule, which increases its hydrodynamic diameter and reduces tissue extravasation. Several commercial PEGylated Hbs (MP4®, Sanguinate®, Euro‐PEG‐Hb) have been developed for clinical use with a longer circulatory half‐life and improved safety compared to Hb. However, all of these commercial products exhibited relatively high oxygen affinity compared to Hb, which limited their clinical use. To dually address the limitations of prior generations of polymerized and PEGylated Hbs, this current study describes the PEGylation of polymerized bovine Hb (PEG‐PolybHb) in both the tense (T) and relaxed (R) quaternary state via thiol‐maleimide chemistry to produce an HBOC with low or high oxygen affinity. The biophysical properties of PEG‐PolybHb were measured and compared with those of commercial polymerized and PEGylated HBOCs. T‐state PEG‐PolybHb possessed higher hydrodynamic volume and P50 than previous generations of commercial PEGylated Hbs. Both T‐ and R‐state PEG‐PolybHb exhibited significantly lower haptoglobin binding rates than the precursor PolybHb, indicating potentially reduced clearance by CD163 + monocytes and macrophages. Thus, T‐state PEG‐PolybHb is expected to function as a promising HBOC due to its low oxygen affinity and enhanced stealth properties afforded by the PEG hydration shell.
- 6 April 2021
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 22 (5) , 2081-2093
Structural Stability and Biophysical Properties of the Mega-Protein Erythrocruorin Are Regulated by Polyethylene Glycol Surface Coverage
A wide variety of hemoglobin-based oxygen carriers (HBOCs) have been designed for use as red blood cell (RBC) substitutes in transfusion medicine, ex vivo organ perfusion, oxygen delivery to hypoxic tissues, and a myriad of other applications. However, hemoglobin (Hb) derived from annelids (erythrocruorins [Ecs]) comprise a natural class of HBOC, since they are larger in size (30 nm in diameter) and contain more heme groups per molecule (144 heme groups) compared to human Hb (hHb; 5 nm in diameter and 4 heme groups). The larger size of Ec compared to hHb reduces tissue extravasation from the vascular space, thus, reducing vasoconstriction, systemic hypertension, and tissue oxidative injury when used as an RBC substitute. In addition, prior research has shown that Ecs possess slower auto-oxidation rates than hHb at physiological temperature, thus, making them attractive candidates for use as RBC substitutes. Unfortunately, it was also observed that Ecs have a much lower circulatory half-life in vivo compared to other HBOCs. Hence, conjugating polyethylene glycol (PEG) to the surface of Ec was proposed as a simple strategy to increase Ec circulatory half-life. Therefore, in order to inform future in vivo studies with PEGylated Ec, we decided to investigate the structural stability and biophysical properties of variable PEG surface coverage on Ec compared to native Ec. We observed an increase in PEG-Ec diameter and molecular weight (MW) and changes to the quaternary structure, secondary structure, and surface hydrophobicity after PEGylation. There was also an increase in oxygen binding affinity, reduction in oxygen offloading rate, and increase in auto-oxidation rate for increasing PEGylation ratios. Weak dissociation of Ec was also observed after dense PEGylation caused by steric repulsion of the conjugated PEG chains. Hence, we determined an optimum Ec PEGylation ratio that resulted in a substantial size and MW increase along with preservation of oxygen binding properties. In future studies, these materials will be tested in animal models to evaluate pharmacodynamics, pharmacokinetics, tissue oxygenation, microcirculatory responses, and overall safety.
- 6 April 2021
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 22 (5) , 2081-2093
Structural Stability and Biophysical Properties of the Mega-Protein Erythrocruorin Are Regulated by Polyethylene Glycol Surface Coverage
A wide variety of hemoglobin-based oxygen carriers (HBOCs) have been designed for use as red blood cell (RBC) substitutes in transfusion medicine, ex vivo organ perfusion, oxygen delivery to hypoxic tissues, and a myriad of other applications. However, hemoglobin (Hb) derived from annelids (erythrocruorins [Ecs]) comprise a natural class of HBOC, since they are larger in size (30 nm in diameter) and contain more heme groups per molecule (144 heme groups) compared to human Hb (hHb; 5 nm in diameter and 4 heme groups). The larger size of Ec compared to hHb reduces tissue extravasation from the vascular space, thus, reducing vasoconstriction, systemic hypertension, and tissue oxidative injury when used as an RBC substitute. In addition, prior research has shown that Ecs possess slower auto-oxidation rates than hHb at physiological temperature, thus, making them attractive candidates for use as RBC substitutes. Unfortunately, it was also observed that Ecs have a much lower circulatory half-life in vivo compared to other HBOCs. Hence, conjugating polyethylene glycol (PEG) to the surface of Ec was proposed as a simple strategy to increase Ec circulatory half-life. Therefore, in order to inform future in vivo studies with PEGylated Ec, we decided to investigate the structural stability and biophysical properties of variable PEG surface coverage on Ec compared to native Ec. We observed an increase in PEG-Ec diameter and molecular weight (MW) and changes to the quaternary structure, secondary structure, and surface hydrophobicity after PEGylation. There was also an increase in oxygen binding affinity, reduction in oxygen offloading rate, and increase in auto-oxidation rate for increasing PEGylation ratios. Weak dissociation of Ec was also observed after dense PEGylation caused by steric repulsion of the conjugated PEG chains. Hence, we determined an optimum Ec PEGylation ratio that resulted in a substantial size and MW increase along with preservation of oxygen binding properties. In future studies, these materials will be tested in animal models to evaluate pharmacodynamics, pharmacokinetics, tissue oxygenation, microcirculatory responses, and overall safety.
- 4 April 2021
- Published by Wiley in Transfusion
- Vol. 61 (6) , 1894-1907
Purification and analysis of a protein cocktail capable of scavenging cell‐free hemoglobin, heme, and iron
Background: Hemolysis releases toxic cell‐free hemoglobin (Hb), heme, and iron, which overwhelm their natural scavenging mechanisms during acute or chronic hemolytic conditions. This study describes a novel strategy to purify a protein cocktail containing a comprehensive set of scavenger proteins for potential treatment of hemolysis byproducts.Study Design and Methods: Tangential flow filtration was used to purify a protein cocktail from Human Cohn Fraction IV (FIV). A series of in vitro assays were performed to characterize composition and biocompatibility. The in vivo potential for hemolysis byproduct mitigation was assessed in a hamster exchange transfusion model using mechanically hemolyzed blood plasma mixed with the protein cocktail or a control colloid (dextran 70 kDa).Results: A basis of 500 g of FIV yielded 62 ± 9 g of a protein mixture at 170 g/L, which bound to approximately 0.6 mM Hb, 1.2 mM heme, and 1.2 mM iron. This protein cocktail was shown to be biocompatible in vitro with red blood cells and platelets and exhibits nonlinear concentration dependence with respect to viscosity and colloidal osmotic pressure. In vivo assessment of the protein cocktail demonstrated higher iron transport to the liver and spleen and less to the kidney and heart with significantly reduced renal and cardiac inflammation markers and lower kidney and hepatic damage compared to a control colloid.Discussion: Taken together, this study provides an effective method for large‐scale production of a protein cocktail suitable for comprehensive reduction of hemolysis‐induced toxicity.
- 4 April 2021
- Published by Wiley in Transfusion
- Vol. 61 (6) , 1894-1907
Purification and analysis of a protein cocktail capable of scavenging cell‐free hemoglobin, heme, and iron
Background: Hemolysis releases toxic cell‐free hemoglobin (Hb), heme, and iron, which overwhelm their natural scavenging mechanisms during acute or chronic hemolytic conditions. This study describes a novel strategy to purify a protein cocktail containing a comprehensive set of scavenger proteins for potential treatment of hemolysis byproducts.Study Design and Methods: Tangential flow filtration was used to purify a protein cocktail from Human Cohn Fraction IV (FIV). A series of in vitro assays were performed to characterize composition and biocompatibility. The in vivo potential for hemolysis byproduct mitigation was assessed in a hamster exchange transfusion model using mechanically hemolyzed blood plasma mixed with the protein cocktail or a control colloid (dextran 70 kDa).Results: A basis of 500 g of FIV yielded 62 ± 9 g of a protein mixture at 170 g/L, which bound to approximately 0.6 mM Hb, 1.2 mM heme, and 1.2 mM iron. This protein cocktail was shown to be biocompatible in vitro with red blood cells and platelets and exhibits nonlinear concentration dependence with respect to viscosity and colloidal osmotic pressure. In vivo assessment of the protein cocktail demonstrated higher iron transport to the liver and spleen and less to the kidney and heart with significantly reduced renal and cardiac inflammation markers and lower kidney and hepatic damage compared to a control colloid.Discussion: Taken together, this study provides an effective method for large‐scale production of a protein cocktail suitable for comprehensive reduction of hemolysis‐induced toxicity.
- 11 August 2020
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 6 (9) , 4957-4968
Purification of Lumbricus terrestris Mega-Hemoglobin for Diverse Oxygen Therapeutic Applications
Oxygen therapeutics are being developed for a variety of applications in transfusion medicine. In order to reduce the side effects (vasoconstriction, systemic hypertension, and oxidative tissue injury) associated with previous generations of oxygen therapeutics, new strategies are focused on increasing the molecular diameter of hemoglobin (Hb) obtained from mammalian sources via polymerization and encapsulation. Another approach toward oxygen therapeutic design has centered on using naturally occurring large molecular diameter Hbs [i.e., erythrocruorins (Ecs)] derived from annelid sources. Therefore, the goal of this study was to purify Ec from the terrestrial worm Lumbricus terrestris for diverse oxygen therapeutic applications. Tangential flow filtration was used as a scalable protein purification platform to obtain a >99% pure Lumbricus terrestris Ec (LtEc) product, which was confirmed by size exclusion high-performance liquid chromatography and sodium dodecyl sulfate-polyacrylamide gel electrophoresis analysis. In vitro characterization concluded that the ultrapure LtEc product had oxygen equilibrium properties similar to those of human red blood cells and a lower rate of auto-oxidation compared to human Hb, both of which should enable efficient oxygen transport under physiological conditions. In vivo evaluation concluded that the ultrapure product had positive effects on the microcirculation sustaining functional capillary density compared to a less pure product (∼86% purity). In summary, we purified an LtEc product with favorable biophysical properties that performed well in an animal model using a reliable and scalable purification platform to eliminate undesirable proteins.
- 11 August 2020
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 6 (9) , 4957-4968
Purification of Lumbricus terrestris Mega-Hemoglobin for Diverse Oxygen Therapeutic Applications
Oxygen therapeutics are being developed for a variety of applications in transfusion medicine. In order to reduce the side effects (vasoconstriction, systemic hypertension, and oxidative tissue injury) associated with previous generations of oxygen therapeutics, new strategies are focused on increasing the molecular diameter of hemoglobin (Hb) obtained from mammalian sources via polymerization and encapsulation. Another approach toward oxygen therapeutic design has centered on using naturally occurring large molecular diameter Hbs [i.e., erythrocruorins (Ecs)] derived from annelid sources. Therefore, the goal of this study was to purify Ec from the terrestrial worm Lumbricus terrestris for diverse oxygen therapeutic applications. Tangential flow filtration was used as a scalable protein purification platform to obtain a >99% pure Lumbricus terrestris Ec (LtEc) product, which was confirmed by size exclusion high-performance liquid chromatography and sodium dodecyl sulfate-polyacrylamide gel electrophoresis analysis. In vitro characterization concluded that the ultrapure LtEc product had oxygen equilibrium properties similar to those of human red blood cells and a lower rate of auto-oxidation compared to human Hb, both of which should enable efficient oxygen transport under physiological conditions. In vivo evaluation concluded that the ultrapure product had positive effects on the microcirculation sustaining functional capillary density compared to a less pure product (∼86% purity). In summary, we purified an LtEc product with favorable biophysical properties that performed well in an animal model using a reliable and scalable purification platform to eliminate undesirable proteins.
- 15 June 2020
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 3 (7) , 4495-4506
Enhanced Photodynamic Therapy Using the Apohemoglobin-Haptoglobin Complex as a Carrier of Aluminum Phthalocyanine
Photodynamic therapy (PDT) has been shown to effectively treat cancer by producing cytotoxic reactive oxygen species via excitation of photosensitizer (PS). However, most PS lack tumor cell specificity, possess poor aqueous solubility, and cause systemic photosensitivity. Removing heme from hemoglobin (Hb) yields an apoprotein called apohemoglobin (apoHb) with a vacant heme-binding pocket that can efficiently bind to hydrophobic molecules such as PS. In this study, the PS aluminum phthalocyanine (Al-PC) was bound to the apoHb-haptoglobin (apoHb-Hp) protein complex, forming an apoHb-Al-PC-Hp (APH) complex. The reaction of Al-PC with apoHb prevented Al-PC aggregation in aqueous solution, retaining the characteristic spectral properties of Al-PC. The stability of apoHb-Al-PC was enhanced via binding with Hp to form the APH complex, which allowed for repeated Al-PC additions to maximize Al-PC encapsulation. The final APH product had 65% of the active heme-binding sites of apoHb bound to Al-PC and a hydrodynamic diameter of 18 nm that could potentially reduce extravasation of the molecule through the blood vessel wall and prevent kidney accumulation of Al-PC. Furthermore, more than 80% of APH’s absorbance spectra were retained when incubated for over a day in plasma at 37 °C. Heme displacement assays confirmed that Al-PC was bound within the heme-binding pocket of apoHb and binding specificity was demonstrated by ineffective Al-PC binding to human serum albumin, Hp, or Hb. In vitro studies confirmed enhanced singlet oxygen generation of APH over Al-PC in aqueous solution and demonstrated effective PDT on human and murine cancer cells. Taken together, this study provides a method to produce APH for enhanced PDT via improved PS solubility and potential targeted therapy via uptake by CD163+ macrophages and monocytes in the tumor (i.e., tumor-associated macrophages). Moreover, this scalable method for site-specific encapsulation of Al-PC into apoHb and apoHb-Hp may be used for other hydrophobic therapeutic agents.
- 15 June 2020
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 3 (7) , 4495-4506
Enhanced Photodynamic Therapy Using the Apohemoglobin-Haptoglobin Complex as a Carrier of Aluminum Phthalocyanine
Photodynamic therapy (PDT) has been shown to effectively treat cancer by producing cytotoxic reactive oxygen species via excitation of photosensitizer (PS). However, most PS lack tumor cell specificity, possess poor aqueous solubility, and cause systemic photosensitivity. Removing heme from hemoglobin (Hb) yields an apoprotein called apohemoglobin (apoHb) with a vacant heme-binding pocket that can efficiently bind to hydrophobic molecules such as PS. In this study, the PS aluminum phthalocyanine (Al-PC) was bound to the apoHb-haptoglobin (apoHb-Hp) protein complex, forming an apoHb-Al-PC-Hp (APH) complex. The reaction of Al-PC with apoHb prevented Al-PC aggregation in aqueous solution, retaining the characteristic spectral properties of Al-PC. The stability of apoHb-Al-PC was enhanced via binding with Hp to form the APH complex, which allowed for repeated Al-PC additions to maximize Al-PC encapsulation. The final APH product had 65% of the active heme-binding sites of apoHb bound to Al-PC and a hydrodynamic diameter of 18 nm that could potentially reduce extravasation of the molecule through the blood vessel wall and prevent kidney accumulation of Al-PC. Furthermore, more than 80% of APH’s absorbance spectra were retained when incubated for over a day in plasma at 37 °C. Heme displacement assays confirmed that Al-PC was bound within the heme-binding pocket of apoHb and binding specificity was demonstrated by ineffective Al-PC binding to human serum albumin, Hp, or Hb. In vitro studies confirmed enhanced singlet oxygen generation of APH over Al-PC in aqueous solution and demonstrated effective PDT on human and murine cancer cells. Taken together, this study provides a method to produce APH for enhanced PDT via improved PS solubility and potential targeted therapy via uptake by CD163+ macrophages and monocytes in the tumor (i.e., tumor-associated macrophages). Moreover, this scalable method for site-specific encapsulation of Al-PC into apoHb and apoHb-Hp may be used for other hydrophobic therapeutic agents.
- 12 June 2020
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 117 (8) , 2362-2376
Comprehensive characterization of tense and relaxed quaternary state glutaraldehyde polymerized bovine hemoglobin as a function of cross‐link density
Previously, our lab developed high molecular weight (MW) tense (T) quaternary state glutaraldehyde polymerized bovine hemoglobins (PolybHbs) that exhibited reduced vasoactivity in several small animal models. In this study, we prepared PolybHb in the T and relaxed (R) quaternary state with ultrahigh MW (>500 kDa) with varying cross‐link densities, and investigated the effect of MW on key biophysical properties (i.e., O2 affinity, cooperativity (Hill) coefficient, hydrodynamic diameter, polydispersity, polymer composition, viscosity, gaseous ligand‐binding kinetics, auto‐oxidation, and haptoglobin [Hp]‐binding kinetics). To further optimize current PolybHb synthesis and purification protocols, we performed a comprehensive meta‐data analysis to evaluate correlations between procedural parameters (i.e., cross‐linker:bovine hemoglobin (bHb) molar ratio, gas‐liquid exchange time, temperature during sodium dithionite addition, and number of diafiltration cycles) and the biophysical properties of both T‐ and R‐state PolybHbs. Our results showed that, the duration of the fast‐step auto‐oxidation phase of R‐state PolybHb increased with decreasing glutaraldehyde:bHb molar ratio. Additionally, T‐state PolybHbs exhibited significantly higher bimolecular rate constants for binding to Hp and unimolecular O2 offloading rate constants compared to R‐state PolybHbs. The methemoglobin (metHb) level in the final product was insensitive to the molar ratio of glutaraldehyde to bHb for all PolybHbs. During tangential flow filtration processing of the final product, 14 diafiltration cycles was found to yield the lowest metHb level.
- 12 June 2020
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 117 (8) , 2362-2376
Comprehensive characterization of tense and relaxed quaternary state glutaraldehyde polymerized bovine hemoglobin as a function of cross‐link density
Previously, our lab developed high molecular weight (MW) tense (T) quaternary state glutaraldehyde polymerized bovine hemoglobins (PolybHbs) that exhibited reduced vasoactivity in several small animal models. In this study, we prepared PolybHb in the T and relaxed (R) quaternary state with ultrahigh MW (>500 kDa) with varying cross‐link densities, and investigated the effect of MW on key biophysical properties (i.e., O2 affinity, cooperativity (Hill) coefficient, hydrodynamic diameter, polydispersity, polymer composition, viscosity, gaseous ligand‐binding kinetics, auto‐oxidation, and haptoglobin [Hp]‐binding kinetics). To further optimize current PolybHb synthesis and purification protocols, we performed a comprehensive meta‐data analysis to evaluate correlations between procedural parameters (i.e., cross‐linker:bovine hemoglobin (bHb) molar ratio, gas‐liquid exchange time, temperature during sodium dithionite addition, and number of diafiltration cycles) and the biophysical properties of both T‐ and R‐state PolybHbs. Our results showed that, the duration of the fast‐step auto‐oxidation phase of R‐state PolybHb increased with decreasing glutaraldehyde:bHb molar ratio. Additionally, T‐state PolybHbs exhibited significantly higher bimolecular rate constants for binding to Hp and unimolecular O2 offloading rate constants compared to R‐state PolybHbs. The methemoglobin (metHb) level in the final product was insensitive to the molar ratio of glutaraldehyde to bHb for all PolybHbs. During tangential flow filtration processing of the final product, 14 diafiltration cycles was found to yield the lowest metHb level.