EGEric Giglio

Eric Giglio

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eric Giglio has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Image charge force of keV ions through insulating nanocapillaries

    by Eric Giglio

    In nanocapillaries of large aspect ratio, the attractive image charge force is strong enough to affect the trajectory of ions passing through capillaries and consequently to diminish the fraction of transmitted beam ions. We calculated the theoretically transmitted fraction, using an expression of the image charge force valid in the case of a static ion and an infinite cylindrical dielectric interface. When comparing the theoretically transmitted fraction to the available experimental data for nanocapillaries with an inner diameter of less than 200 nm, we found a surprisingly large disagreement, i.e., the theoretically transmitted fractions were easily an order of magnitude lower than the experimental ones. Noting that the image charge force depends on the velocity of the ion via the frequency-dependent relative permittivity of the insulator, we investigated whether the disagreement could be lifted using a velocity depend image charge force. We give the exact expressions of the dynamical image charge force for a plane and cylindrical dielectric interface as a function of the ion velocity. We then reevaluated the theoretically transmitted fractions in the case of SiO2 and polyethylene terephthalate dielectric interfaces. Our findings are discussed in light of the available experimental data.


  • Open Access

    Guiding of keV ions between two insulating parallel plates

    by R. D. DuBois, K. Tőkési, E. Giglio

    Experimental data are presented for low-energy singly charged ion transport between two insulating parallel plates. Using a beam intensity of approximately 20 pA, measurements of the incoming and transmitted beams provide quantitative temporal information about the charge deposited on the plates and the guiding probability. Using a smaller beam intensity (~ 1 pA) plate charging and discharging properties were studied as a function of time. These data imply that both the charge deposition and decay along the surface and through the bulk need to be modeled as acting independently. A further reduction of beam intensity to ~ 25 fA allowed temporal imaging studies of the positions and intensities of the guided beam plus two bypass beams to be performed. SIMION software was used to simulate trajectories of the guided and bypass beams, to provide information about the amount and location of deposited charge and, as a function of charge patch voltage, the probability of beam guiding and how much the bypass beams are deflected plus to provide information about the electric fields. An equivalent electric circuit model of the parallel plates, used to associate the deposited charge with the patch voltage implies that the deposited charge is distributed primarily on the inner surface of the plates, transverse to the beam direction, rather than being distributed throughout the entire plate.

  • Open Access

    Stabilizing the ion-beam transmission through tapered glass capillaries

    by E. Giglio, M. Léger

    When an ion beam is injected into a tapered insulating capillary, the induced self-organized radial Coulomb potential in the capillary is able to focus the beam like an electrostatic lens. However, because of the continued accumulation of charge in the capillary, an equilibrium is rarely attained and the injected beam is eventually Coulomb blocked by the capillary's potential. We propose an original add-on to the capillary setup, which can be tested experimentally and which is expected to hinder the Coulomb blocking. We investigate numerically the benefits and limits of the modified capillary setup. We show how the intensity and emittance of the injected beam control the transmission rate through conically tapered capillaries. Our results indicate that the add-on succeeds to stabilize the asymptotic transmission rate for a larger range of beam intensities and emittances, while reaching a near optimal transmitted fraction up to 90%.


  • Effect of secondary electrons on the patch formation in insulating capillaries by ion beams

    by E. Giglio, T. Le Cornu

    The transmission rate of a low-energy Arq+ ion beam through a macroscopic glass tube of large aspect ratio is simulated. Secondary electron (SE) emission, induced by ion impacts with the inner surface of the capillary, are taken explicitly into account by adding a SE source term to the charge dynamics equation. We find that the additional SE channel significantly alters the distribution of the deposited charge in the capillary wall. Compared to the case without the SE channel, the electric field generated by the self-organized charge patches is generally weaker, yielding drastically different transmission rates, especially for higher beam intensities. The effect of SEs on the patch formation and resulting transmission rate is found to be significant for SE yields as low as 1 SE per ion impact, in the case of Ar+ ions. We propose a numerical experiment that can be tested experimentally, potentially allowing us to conclude if the SE channel is indeed crucial for accurately simulating the guiding of an ion beam through insulating capillaries. In the long run, our simulations may provide theoretical support for measuring the SE yield of low-energy ions impacting insulating surfaces at grazing angles.


  • Charge relaxation rates in insulating straight capillaries

    by Eric Giglio

    The charge relaxation of accumulated charge patches in insulating straight capillaries is investigated theoretically. The model assumes that charges accumulate only at the inner and outer insulator-vacuum interface of the capillary but not in the bulk. We give an analytical solution to the coupled equations that describe the surface charge dynamics at both interfaces. We provide a tool to calculate easily the characteristic relaxation times in a straight capillary of any dimension, possibly surrounded by a conducting cylinder. The latter allows for different scenarios found in experimental setups, and is applicable to both nanocapillaries and macrocapillaries. We propose an original experimental technique to monitor the charge relaxation in a straight glass capillary and show how to use the presented model to extract the bulk and surface conductivity of the insulator from the measured data. In the Supplemental Material, we provide a script in mathematica that allows the reader to compute comfortably the decay rates for all straight insulating capillaries the reader is interested in.


  • Open Access

    Effect of secondary electron emission on the guiding properties of insulating capillaries

    by E Giglio, K Tökési, R D Dubois

    Synopsis: The transmission of 1 keV Ar+ ions through a macroscopic glass capillary is simulated by taking explicitly into account the secondary electron (SE) emission generated by ion impacts inside the capillary. The SE emission re-distributes the injected charge in the capillary wall and thus modifies the guiding power of insulating capillaries. Especially for high beam intensities, SE are found to be crucial for explaining the observed time-evolution of the transmitted intensities.

  • Open Access

    Discharge properties of macroscopic glass capillaries after irradiation by low intensity low energy single charged Ar ions

    by E Giglio, R D DuBois, K Tőkési

    The discharge properties of a macroscopic cylindrically shaped glass capillary, initially charged by a 1 keV Ar+ beam tilted by 5° whith respect to the capillary axis is studied. Our experimental observations were compared to our Monte Carlo simulation, higlighting the importance of the surface conductivity.


  • Open Access

    Combined theoretical and experimental study of the transmission of tilted ion beams through macroscopic conical glass capillaries

    by E Giglio, H Zhang, S Guillous, A Agnihotri, F Ropars, W Iskandar, A Mery, H Merabet, A Cassimi

    The transmission as a function of the tilt angle of a 3 keV Ar+ ion beam through a conical macroscopic glass capillary is studied theoretically and experimentally. It was found that the charge patches which are responsible for the ion guiding also compress the beam spatially in the direction orthogonal to the patches, resulting into an enhancement of the transmission with increasing tilt angle.


  • Angular distribution of emitted electrons in sodium clusters: A semiclassical approach

    by E. Giglio, P.-G. Reinhard, E. Suraud

    We present a theoretical study of the angular distribution of emitted electrons of a sodium cluster, irradiated by short and intense laser pulses. While the polarization of the excitation field tends to focus a directional emission, the dynamical correlations tend to thermalize the electrons, giving rise to a more isotropic ionization. The competition between these processes is investigated using a semiclassical model Vlasov-Ühling-Uhlenbeck, where the dynamical correlations are taken in account by the electron-electron correlations in the Markovian approximation, the widely known Ühling-Uhlenbeck collision term. The results are compared to a semiclassical pure mean-field propagation (Vlasov equation) to work out the influence of dynamical correlations on the angular distribution of the electron emission. The trends with laser intensity and frequency are explored. The time evolution of the angular distributions shows that direct emission processes are stronger in the early phase of the processs, while isotropic thermal emission dominates later.