Paulette Legarraga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paulette Legarraga has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Lorena Porte
Laboratorio Clínico, Clínica Alemana, Facultad de Medicina Clínica Alemana, Universidad del Desarrollo, Santiago 7610658, Chile
4 shared publications - Thomas Weitzel
Laboratorio Clínico, Clínica Alemana, Facultad de Medicina Clínica Alemana, Universidad del Desarrollo, Santiago, Chile
4 shared publications - Valeska Vollrath
Clínica Alemana, Universidad del Desarrollo
3 shared publications - Carmen Varela
Laboratorio Clínico, Clínica Alemana, Facultad de Medicina Clínica Alemana, Universidad del Desarrollo, Santiago, 7630000, Región Metropolitana, Chile
2 shared publications - Gabriel Pizarro
Clínica Alemana, Universidad del Desarrollo
2 shared publications - Jose Manuel Munita
Genomics & Resistant Microbes Group (GeRM), Instituto de Ciencias e Innovación en Medicina (ICIM), Facultad de Medicina Clinica Alemana, Universidad del Desarrollo
2 shared publications
Latest Publications
- Open Access
- 8 August 2024
- Published by MDPI AG in Preprints.org
Performance of the VITEK MS System for the Identification of Filamentous Fungi in a Routine Microbiological Laboratory in Chile
Background: Filamentous fungi are an emergent cause of severe infections in immunocompromised patients. Timely and accurate identification is crucial to initiate appropriate therapy. Traditional identification methods are time-consuming, labor-intensive, and operator-dependent. Ma-trix-assisted laser desorption/ionization-time-of-flight (MALDI-TOF) mass spectrometry is a rapid and easy-to-perform identification method. This study evaluates the effectiveness of a commercial MALDI-TOF MS platform to identify filamentous fungi in a routine laboratory. Material and Methods: We included 67 fungal isolates from 35 species/species complexes within 15 genera, confirmed in mycology reference laboratories. 33 were from clinical samples and 34 from strain collections. The study used the VITEK MS system (v3.2.0 database), after sample extraction by VITEK MS Mould Kit. Results were classified into categories: ‘correct species’, ‘correct species complex’, ‘correct genus’, ‘incorrect identification’, and ‘no identification’. We also evaluated the practicality of the kit. Results: VITEK MS correctly identified 91.0% of isolates (58.2% to species, 29.9% to species complex, and 1.5% to genus level). In 82%, the result matched the species/species complex identified by reference methods. No misidentifications were observed. The kit was rapid and easy to use. Conclusion: The VITEK MS system showed a high capability to accurately identify filamentous fungi in a routine laboratory.
- 8 August 2024
- Published by MDPI AG in Preprints.org
Open AccessPerformance of the VITEK MS System for the Identification of Filamentous Fungi in a Routine Microbiological Laboratory in Chile
Background: Filamentous fungi are an emergent cause of severe infections in immunocompromised patients. Timely and accurate identification is crucial to initiate appropriate therapy. Traditional identification methods are time-consuming, labor-intensive, and operator-dependent. Ma-trix-assisted laser desorption/ionization-time-of-flight (MALDI-TOF) mass spectrometry is a rapid and easy-to-perform identification method. This study evaluates the effectiveness of a commercial MALDI-TOF MS platform to identify filamentous fungi in a routine laboratory. Material and Methods: We included 67 fungal isolates from 35 species/species complexes within 15 genera, confirmed in mycology reference laboratories. 33 were from clinical samples and 34 from strain collections. The study used the VITEK MS system (v3.2.0 database), after sample extraction by VITEK MS Mould Kit. Results were classified into categories: ‘correct species’, ‘correct species complex’, ‘correct genus’, ‘incorrect identification’, and ‘no identification’. We also evaluated the practicality of the kit. Results: VITEK MS correctly identified 91.0% of isolates (58.2% to species, 29.9% to species complex, and 1.5% to genus level). In 82%, the result matched the species/species complex identified by reference methods. No misidentifications were observed. The kit was rapid and easy to use. Conclusion: The VITEK MS system showed a high capability to accurately identify filamentous fungi in a routine laboratory.
- Open Access
Campylobacter spp. Prevalence in Santiago, Chile: A Study Based on Molecular Detection in Clinical Stool Samples from 2014 to 2019
Campylobacter spp. is an emerging cause of infectious diarrhea worldwide. In South American countries such as Chile, its prevalence is underestimated due to inadequate detection methods. Gastrointestinal multiplex PCR panels (GMP) permit rapid and sensitive detection of bacterial pathogens and provide important epidemiological information. This study aimed to analyze Campylobacter epidemiology using the results of molecular methods and to compare molecular detection results to those of culture methods. We performed a retrospective, descriptive analysis of Campylobacter spp. detected in clinical stool samples between 2014–2019 by GMP and culture. Within 16,582 specimens examined by GMP, Campylobacter was the most prevalent enteropathogenic bacteria (8.5%), followed by Salmonella spp. (3.9%), Shigella spp./enteroinvasive Escherichia coli (EIEC) (1.9%), and Yersinia enterocolitica (0.8%). The highest Campylobacter prevalence occurred in 2014/2015. Campylobacteriosis affected more males (57.2%) and adults from 19–65 years (47.9%) and showed a bimodal seasonality with summer and winter peaks. In 11,251 routine stool cultures, Campylobacter spp. was detected in 4.6%, mostly C. jejuni (89.6%). Among 4533 samples tested by GMP and culture in parallel, GMP showed a superior sensitivity (99.1% versus 50%, respectively). The study suggests that Campylobacter spp. is the most frequent bacterial enteropathogen in Chile.
Open AccessCampylobacter spp. Prevalence in Santiago, Chile: A Study Based on Molecular Detection in Clinical Stool Samples from 2014 to 2019
Campylobacter spp. is an emerging cause of infectious diarrhea worldwide. In South American countries such as Chile, its prevalence is underestimated due to inadequate detection methods. Gastrointestinal multiplex PCR panels (GMP) permit rapid and sensitive detection of bacterial pathogens and provide important epidemiological information. This study aimed to analyze Campylobacter epidemiology using the results of molecular methods and to compare molecular detection results to those of culture methods. We performed a retrospective, descriptive analysis of Campylobacter spp. detected in clinical stool samples between 2014–2019 by GMP and culture. Within 16,582 specimens examined by GMP, Campylobacter was the most prevalent enteropathogenic bacteria (8.5%), followed by Salmonella spp. (3.9%), Shigella spp./enteroinvasive Escherichia coli (EIEC) (1.9%), and Yersinia enterocolitica (0.8%). The highest Campylobacter prevalence occurred in 2014/2015. Campylobacteriosis affected more males (57.2%) and adults from 19–65 years (47.9%) and showed a bimodal seasonality with summer and winter peaks. In 11,251 routine stool cultures, Campylobacter spp. was detected in 4.6%, mostly C. jejuni (89.6%). Among 4533 samples tested by GMP and culture in parallel, GMP showed a superior sensitivity (99.1% versus 50%, respectively). The study suggests that Campylobacter spp. is the most frequent bacterial enteropathogen in Chile.
- Open Access
Rapid SARS-CoV-2 antigen detection by immunofluorescence – a new tool to detect infectivity
The evaluated SARS-CoV-2 antigen rapid fluorescence immunoassays reliably identified patients within the first 5 days of symptom onset, when respiratory secretions carried high viral loads. This high performance suggests that these tests might play an important role for future PCR-independent strategies to detect early or infective cases.
Open AccessRapid SARS-CoV-2 antigen detection by immunofluorescence – a new tool to detect infectivity
The evaluated SARS-CoV-2 antigen rapid fluorescence immunoassays reliably identified patients within the first 5 days of symptom onset, when respiratory secretions carried high viral loads. This high performance suggests that these tests might play an important role for future PCR-independent strategies to detect early or infective cases.
- Open Access
Head-to-head comparison of four antigen-based rapid detection tests for the diagnosis of SARS-CoV-2 in respiratory samples
In the context of the Covid-19 pandemic, the development and validation of rapid and easy-to-perform diagnostic methods are of high priority. We compared the performance of four rapid antigen detection tests for SARS-CoV-2 in respiratory samples. Immunochromatographic SARS-CoV-2 assays from RapiGEN, Liming bio, Savant, and Bioeasy were evaluated using universal transport medium containing naso-oropharyngeal swabs from suspected Covid-19 cases. The diagnostic accuracy was determined in comparison to SARS-CoV-2 RT-PCR. A total of 111 samples were included; 80 were RT-PCR positive. Median patients’ age was 40 years, 55% were female, and 88% presented within the first week after symptom onset. The evaluation of the Liming bio assay was discontinued due to insufficient performance. The overall sensitivity values of RapiGEN, Liming bio, and Bioeasy tests were 62.0% (CI95% 51.0–71.9), 16.7% (CI95% 10.0–26.5), and 85.0% (CI95% 75.6–91.2), respectively, with specificities of 100%. Sensitivity was significantly higher in samples with high viral loads (RapiGEN, 84.9%; Bioeasy, 100%). The study highlighted the significant heterogeneity of test performance among evaluated assays, which might have been influenced by the use of a non-validated sample material. The high sensitivity of some tests demonstrated that rapid antigen detection has the potential to serve as an alternative diagnostic method, especially in patients presenting with high viral loads in early phases of infection. This is particularly important in situations with limited access to RT-PCR or prolonged turnaround time. Further comparative evaluations are necessary to select products with high performance among the growing market of diagnostic tests for SARS-CoV-2.
Open AccessHead-to-head comparison of four antigen-based rapid detection tests for the diagnosis of SARS-CoV-2 in respiratory samples
In the context of the Covid-19 pandemic, the development and validation of rapid and easy-to-perform diagnostic methods are of high priority. We compared the performance of four rapid antigen detection tests for SARS-CoV-2 in respiratory samples. Immunochromatographic SARS-CoV-2 assays from RapiGEN, Liming bio, Savant, and Bioeasy were evaluated using universal transport medium containing naso-oropharyngeal swabs from suspected Covid-19 cases. The diagnostic accuracy was determined in comparison to SARS-CoV-2 RT-PCR. A total of 111 samples were included; 80 were RT-PCR positive. Median patients’ age was 40 years, 55% were female, and 88% presented within the first week after symptom onset. The evaluation of the Liming bio assay was discontinued due to insufficient performance. The overall sensitivity values of RapiGEN, Liming bio, and Bioeasy tests were 62.0% (CI95% 51.0–71.9), 16.7% (CI95% 10.0–26.5), and 85.0% (CI95% 75.6–91.2), respectively, with specificities of 100%. Sensitivity was significantly higher in samples with high viral loads (RapiGEN, 84.9%; Bioeasy, 100%). The study highlighted the significant heterogeneity of test performance among evaluated assays, which might have been influenced by the use of a non-validated sample material. The high sensitivity of some tests demonstrated that rapid antigen detection has the potential to serve as an alternative diagnostic method, especially in patients presenting with high viral loads in early phases of infection. This is particularly important in situations with limited access to RT-PCR or prolonged turnaround time. Further comparative evaluations are necessary to select products with high performance among the growing market of diagnostic tests for SARS-CoV-2.