NENino Epitashvili

Nino Epitashvili

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nino Epitashvili has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of epileptic seizures on the quality of biosignals recorded from wearables

    by Sebastian Böttcher, Nicolas Zabler, Michele Jackson, Elisa Bruno, Andrea Biondi, Nino Epitashvili, Solveig Vieluf, Matthias Dümpelmann, Mark P. Richardson, Benjamin H. Brinkmann, et al.

    Objective: Wearable nonelectroencephalographic biosignal recordings captured from the wrist offer enormous potential for seizure monitoring. However, signal quality remains a challenging factor affecting data reliability. Models trained for seizure detection depend on the quality of recordings in peri‐ictal periods in performing a feature‐based separation of ictal periods from interictal periods. Thus, this study aims to investigate the effect of epileptic seizures on signal quality, ensuring accurate and reliable monitoring.Methods: This study assesses the signal quality of wearable data during peri‐ictal phases of generalized tonic–clonic and focal to bilateral tonic–clonic seizures (TCS), focal motor seizures (FMS), and focal nonmotor seizures (FNMS). We evaluated accelerometer (ACC) activity and the signal quality of electrodermal activity (EDA) and blood volume pulse (BVP) data. Additionally, we analyzed the influence of peri‐ictal movements as assessed by ACC (ACC activity) on signal quality and examined intraictal subphases of focal to bilateral TCS.Results: We analyzed 386 seizures from 111 individuals in three international epilepsy monitoring units. BVP signal quality and ACC activity levels differed between all seizure types. We found the largest decrease in BVP signal quality and increase in ACC activity when comparing the ictal phase to the pre‐ and postictal phases for TCS. Additionally, ACC activity was strongly negatively correlated with BVP signal quality for TCS and FMS, and weakly for FNMS. Intraictal analysis revealed that tonic and clonic subphases have the lowest BVP signal quality and the highest ACC activity.Significance: Motor elements of seizures significantly impair BVP signal quality, but do not have significant effect on EDA signal quality, as assessed by wrist‐worn wearables. The results underscore the importance of signal quality assessment methods and careful selection of robust modalities to ensure reliable seizure detection. Future research is needed to explain whether seizure detection models' decisions are based on signal responses induced by physiological processes as opposed to artifacts.


  • Open Access

    Effectiveness of add‐on acetazolamide in children with drug‐resistant CHD2‐related epilepsy and in a zebrafish CHD2 model

    by Gia Melikishvili, Pasquale Striano, Elham Shojeinia, Tamar Gachechiladze, Ekaterine Kurua, Nazhi Tabatadze, Mariam Melikishvili, Otar Koniashvili, Gvantsa Khachiashvili, Nino Epitashvili, et al.

    CHD2‐related epilepsy is characterized by early‐onset photosensitive myoclonic epilepsy with developmental delay and a high rate of pharmacoresistance. We sought to evaluate the efficacy of acetazolamide (ACZ) in CHD2‐related epilepsy, due to ACZ's unexpected efficacy in our first patient harboring a pathogenic CHD2 variant. We collected patients from different Eastern European countries with drug‐resistant CHD2‐related epilepsy who were then treated with ACZ. Patients underwent video EEG before and during ACZ treatment. In a zebrafish model of CHD2‐related epilepsy, ictal‐like events were recorded 5 days post‐fertilization after overnight ACZ exposure. Developmental delay preceded the onset of seizures in 10 of the 12 patients. Four had ataxia, and 6 exhibited autistic features. Seizures, primarily myoclonic, began at an average age of 3.4 years and were photosensitive in all 12 patients. Add‐on ACZ treatment controlled photosensitive seizures in all patients: 6 became seizure‐free, and in the remaining 6, seizure frequency decreased by over 75%. Four patients transitioned to ACZ monotherapy. The median follow‐up was 13 months. In the zebrafish model, ACZ exposure reduced ictal‐like events by 72%. ACZ, a well‐tolerated and cost‐effective medication, could be a good option for CHD2‐related epilepsy, predominantly manifesting with myoclonic seizures and photosensitivity.Plain Language Summary: Epilepsy associated with CHD2 mutations is often pharmacoresistant and associated with developmental delay and eventually ataxia. There are several generalized seizure types, including generalized tonic–clonic seizures, but the most characteristic are jerks triggered by light stimulation. We collected 12 patients who received acetazolamide, a drug usually given as a diuretic and registered as a mild antiseizure medication. All jerks triggered by light disappeared while the frequency of spontaneous seizures decreased by over 75%. Further studies are needed to confirm this promising finding and identify the mechanism by which an old compound seems to have such a specific antiseizure effect.


  • Open Access

    Data quality evaluation in wearable monitoring

    by Sebastian Böttcher, Solveig Vieluf, Elisa Bruno, Boney Joseph, Nino Epitashvili, Andrea Biondi, Nicolas Zabler, Martin Glasstetter, Matthias Dümpelmann, Kristof Van Laerhoven, et al.

    Wearable recordings of neurophysiological signals captured from the wrist offer enormous potential for seizure monitoring. Yet, data quality remains one of the most challenging factors that impact data reliability. We suggest a combined data quality assessment tool for the evaluation of multimodal wearable data. We analyzed data from patients with epilepsy from four epilepsy centers. Patients wore wristbands recording accelerometry, electrodermal activity, blood volume pulse, and skin temperature. We calculated data completeness and assessed the time the device was worn (on-body), and modality-specific signal quality scores. We included 37,166 h from 632 patients in the inpatient and 90,776 h from 39 patients in the outpatient setting. All modalities were affected by artifacts. Data loss was higher when using data streaming (up to 49% among inpatient cohorts, averaged across respective recordings) as compared to onboard device recording and storage (up to 9%). On-body scores, estimating the percentage of time a device was worn on the body, were consistently high across cohorts (more than 80%). Signal quality of some modalities, based on established indices, was higher at night than during the day. A uniformly reported data quality and multimodal signal quality index is feasible, makes study results more comparable, and contributes to the development of devices and evaluation routines necessary for seizure monitoring.


  • Open Access

    Intra- and Inter-Subject Perspectives on the Detection of Focal Onset Motor Seizures in Epilepsy Patients

    by Sebastian Böttcher, Elisa Bruno, Nino Epitashvili, Matthias Dümpelmann, Nicolas Zabler, Martin Glasstetter, Valentina Ticcinelli, Sarah Thorpe, Simon Lees, Kristof Van Laerhoven, et al.

    Focal onset epileptic seizures are highly heterogeneous in their clinical manifestations, and a robust seizure detection across patient cohorts has to date not been achieved. Here, we assess and discuss the potential of supervised machine learning models for the detection of focal onset motor seizures by means of a wrist-worn wearable device, both in a personalized context as well as across patients. Wearable data were recorded in-hospital from patients with epilepsy at two epilepsy centers. Accelerometry, electrodermal activity, and blood volume pulse data were processed and features for each of the biosignal modalities were calculated. Following a leave-one-out approach, a gradient tree boosting machine learning model was optimized and tested in an intra-subject and inter-subject evaluation. In total, 20 seizures from 9 patients were included and we report sensitivities of 67% to 100% and false alarm rates of down to 0.85 per 24 h in the individualized assessment. Conversely, for an inter-subject seizure detection methodology tested on an out-of-sample data set, an optimized model could only achieve a sensitivity of 75% at a false alarm rate of 13.4 per 24 h. We demonstrate that robustly detecting focal onset motor seizures with tonic or clonic movements from wearable data may be possible for individuals, depending on specific seizure manifestations.


  • Open Access

    Detecting Tonic-Clonic Seizures in Multimodal Biosignal Data From Wearables: Methodology Design and Validation

    by Sebastian Böttcher, Elisa Bruno, Nikolay V Manyakov, Nino Epitashvili, Kasper Claes, Martin Glasstetter, Sarah Thorpe, Simon Lees, Matthias Dümpelmann, Kristof Van Laerhoven, et al.

    Background: Video electroencephalography recordings, routinely used in epilepsy monitoring units, are the gold standard for monitoring epileptic seizures. However, monitoring is also needed in the day-to-day lives of people with epilepsy, where video electroencephalography is not feasible. Wearables could fill this gap by providing patients with an accurate log of their seizures. Objective: Although there are already systems available that provide promising results for the detection of tonic-clonic seizures (TCSs), research in this area is often limited to detection from 1 biosignal modality or only during the night when the patient is in bed. The aim of this study is to provide evidence that supervised machine learning can detect TCSs from multimodal data in a new data set during daytime and nighttime. Methods: An extensive data set of biosignals from a multimodal watch worn by people with epilepsy was recorded during their stay in the epilepsy monitoring unit at 2 European clinical sites. From a larger data set of 243 enrolled participants, those who had data recorded during TCSs were selected, amounting to 10 participants with 21 TCSs. Accelerometry and electrodermal activity recorded by the wearable device were used for analysis, and seizure manifestation was annotated in detail by clinical experts. Ten accelerometry and 3 electrodermal activity features were calculated for sliding windows of variable size across the data. A gradient tree boosting algorithm was used for seizure detection, and the optimal parameter combination was determined in a leave-one-participant-out cross-validation on a training set of 10 seizures from 8 participants. The model was then evaluated on an out-of-sample test set of 11 seizures from the remaining 2 participants. To assess specificity, we additionally analyzed data from up to 29 participants without TCSs during the model evaluation. Results: In the leave-one-participant-out cross-validation, the model optimized for sensitivity could detect all 10 seizures with a false alarm rate of 0.46 per day in 17.3 days of data. In a test set of 11 out-of-sample TCSs, amounting to 8.3 days of data, the model could detect 10 seizures and produced no false positives. Increasing the test set to include data from 28 more participants without additional TCSs resulted in a false alarm rate of 0.19 per day in 78 days of wearable data. Conclusions: We show that a gradient tree boosting machine can robustly detect TCSs from multimodal wearable data in an original data set and that even with very limited training data, supervised machine learning can achieve a high sensitivity and low false-positive rate. This methodology may offer a promising way to approach wearable-based nonconvulsive seizure detection.


  • Open Access

    Identification of Ictal Tachycardia in Focal Motor- and Non-Motor Seizures by Means of a Wearable PPG Sensor

    by Martin Glasstetter, Sebastian Böttcher, Nicolas Zabler, Nino Epitashvili, Matthias Dümpelmann, Mark P. Richardson, Andreas Schulze-Bonhage

    Photoplethysmography (PPG) as an additional biosignal for a seizure detector has been underutilized so far, which is possibly due to its susceptibility to motion artifacts. We investigated 62 focal seizures from 28 patients with electrocardiography-based evidence of ictal tachycardia (IT). Seizures were divided into subgroups: those without epileptic movements and those with epileptic movements not affecting and affecting the extremities. PPG-based heart rate (HR) derived from a wrist-worn device was calculated for sections with high signal quality, which were identified using spectral entropy. Overall, IT based on PPG was identified in 37 of 62 (60%) seizures (9/19, 7/8, and 21/35 in the three groups, respectively) and could be found prior to the onset of epileptic movements affecting the extremities in 14/21 seizures. In 30/37 seizures, PPG-based IT was in good temporal agreement (<10 s) with ECG-based IT, with an average delay of 5.0 s relative to EEG onset. In summary, we observed that the identification of IT by means of a wearable PPG sensor is possible not only for non-motor seizures but also in motor seizures, which is due to the early manifestation of IT in a relevant subset of focal seizures. However, both spontaneous and epileptic movements can impair PPG-based seizure detection.


  • Wearable devices for seizure detection: Practical experiences and recommendations from the Wearables for Epilepsy And Research (WEAR) International Study Group

    by Elisa Bruno, Sebastian Böttcher, Pedro F. Viana, Marta Amengual‐Gual, Boney Joseph, Nino Epitashvili, Matthias Dümpelmann, Martin Glasstetter, Andrea Biondi, Kristof Van Laerhoven, et al.

    The Wearables for Epilepsy And Research (WEAR) International Study Group identified a set of methodology standards to guide research on wearable devices for seizure detection. We formed an international consortium of experts from clinical research, engineering, computer science, and data analytics at the beginning of 2020. The study protocols and practical experience acquired during the development of wearable research studies were discussed and analyzed during bi‐weekly virtual meetings to highlight commonalities, strengths, and weaknesses, and to formulate recommendations. Seven major essential components of the experimental design were identified, and recommendations were formulated about: (1) description of study aims, (2) policies and agreements, (3) study population, (4) data collection and technical infrastructure, (5) devices, (6) reporting results, and (7) data sharing. Introducing a framework of methodology standards promotes optimal, accurate, and consistent data collection. It also guarantees that studies are generalizable and comparable, and that results can be replicated, validated, and shared.


  • Subcortical band heterotopia in a patient with phenylketonuria: Co-Existence or consequence?

    by Nino Epitashvili, Yulia Novitskaya, Dirk-Matthias Altenmüller, Horst Urbach, Andreas Schulze-Bonhage

  • Open Access

    Detecting Tonic-Clonic Seizures in Multimodal Biosignal Data From Wearables: Methodology Design and Validation (Preprint)

    by Sebastian Böttcher, Elisa Bruno, Nikolay V Manyakov, Nino Epitashvili, Kasper Claes, Martin Glasstetter, Sarah Thorpe, Simon Lees, Matthias Dümpelmann, Kristof Van Laerhoven, et al.

    Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Video electroencephalography recordings, routinely used in epilepsy monitoring units, are the gold standard for monitoring epileptic seizures. However, monitoring is also needed in the day-to-day lives of people with epilepsy, where video electroencephalography is not feasible. Wearables could fill this gap by providing patients with an accurate log of their seizures. Objective: Although there are already systems available that provide promising results for the detection of tonic-clonic seizures (TCSs), research in this area is often limited to detection from 1 biosignal modality or only during the night when the patient is in bed. The aim of this study is to provide evidence that supervised machine learning can detect TCSs from multimodal data in a new data set during daytime and nighttime. Methods: An extensive data set of biosignals from a multimodal watch worn by people with epilepsy was recorded during their stay in the epilepsy monitoring unit at 2 European clinical sites. From a larger data set of 243 enrolled participants, those who had data recorded during TCSs were selected, amounting to 10 participants with 21 TCSs. Accelerometry and electrodermal activity recorded by the wearable device were used for analysis, and seizure manifestation was annotated in detail by clinical experts. Ten accelerometry and 3 electrodermal activity features were calculated for sliding windows of variable size across the data. A gradient tree boosting algorithm was used for seizure detection, and the optimal parameter combination was determined in a leave-one-participant-out cross-validation on a training set of 10 seizures from 8 participants. The model was then evaluated on an out-of-sample test set of 11 seizures from the remaining 2 participants. To assess specificity, we additionally analyzed data from up to 29 participants without TCSs during the model evaluation. Results: In the leave-one-participant-out cross-validation, the model optimized for sensitivity could detect all 10 seizures with a false alarm rate of 0.46 per day in 17.3 days of data. In a test set of 11 out-of-sample TCSs, amounting to 8.3 days of data, the model could detect 10 seizures and produced no false positives. Increasing the test set to include data from 28 more participants without additional TCSs resulted in a false alarm rate of 0.19 per day in 78 days of wearable data. Conclusions: We show that a gradient tree boosting machine can robustly detect TCSs from multimodal wearable data in an original data set and that even with very limited training data, supervised machine learning can achieve a high sensitivity and low false-positive rate. This methodology may offer a promising way to approach wearable-based nonconvulsive seizure detection.


  • Open Access

    Post‐ictal accelerometer silence as a marker of post‐ictal immobility

    by Elisa Bruno, Sebastian Böttcher, Andrea Biondi, Nino Epitashvili, Nikolay V. Manyakov, Simon Lees, Andreas Schulze‐Bonhage, Mark P. Richardson, the RADAR-CNS Consortium

    Objective: Movement‐based wearable sensors are used for detection of convulsive seizures. The identification of the absence of motion following a seizure, known as post‐ictal immobility (PI), may represent a potential additional application of wearables. PI has been associated with potentially life‐threatening complications and with sudden unexpected death in epilepsy (SUDEP). We aimed to assess whether wearable accelerometers (ACCs) could be used as a digital marker of PI.Method: Devices with embedded ACCs were worn by patients admitted to an epilepsy monitoring unit. Participants presenting with convulsive seizures were included in the study. PI presence and duration were assessed by experts reviewing video recordings. An algorithm for the automatic detection of post‐ictal ACC silence and its duration was developed and the linear pairwise relationship between the automatically detected duration of post‐ictal ACC silence and the duration of the expert‐labeled PI was analyzed.Results: Twenty‐two convulsive seizures were recorded from 18 study participants. Twenty were followed by PI and two by agitation. The automated estimation of post‐ictal ACC silence identified all the 20 expert‐labeled PI. The regression showed that the duration of the post‐ictal ACC silence was correlated with the duration of PI (Pearsonr = .92;P < .001), with the age of study participants (Pearsonr = .78;P < .001), and with the duration of post‐ictal generalized electroencephalography suppression (PGES; Pearsonr = .4;P = .033).Significance: We highlight a novel application of wearables as a way to record post‐ictal manifestations associated with an increased risk of SUDEP. The occurrence of a fatal seizure is unpredictable and the continuous, non‐invasive, long‐term identification of risk factors associated with each individual seizure may assume a great clinical importance.