Giacomo Ulisse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Giacomo Ulisse has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Viktor Krozer
Department of Physics, Goethe University Frankfurt, 60438 Frankfurt, Germany
9 shared publications - Aldo Moreno-Oyervides
Universidad Carlos III de Madrid
2 shared publications - Alexey A. Serdobintsev
Saratov State University
2 shared publications - Andrey V. Starodubov
Saratov Branch, Kotelnikov Institute of Radio Engineering and Electronics RAS, Saratov, Russia
2 shared publications - Anton M. Pavlov
Research and Educational Institute of Nanostructures and Biosystems, Saratov State University, 410012 Saratov, Russia
2 shared publications - Claudio Paoloni
Lancaster University
2 shared publications
Latest Publications
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 69 (11) , 6358-6361
A 3-D Printed Helix for Traveling-Wave Tubes
In this work, a 3-D printed copper helix for a traveling-wave tube (TWT) is reported. The fabricated helix was designed to be used in a TWT operating at millimeter-wave frequencies (60–80 GHz). The helix was realized with an additive micromanufacturing technique ($\mu $ AM). Measurements were also performed to estimate the losses of the printed material and evaluate the RF performance of deposited copper. Simulations showed that a TWT based on the 3-D printed helix can have a gain of about 30 dB at 66 GHz and a 1-dB bandwidth of about 5 GHz. The estimated losses from RF measurements reveal an RF copper conductivity of about$2\times 10^{{7}}$ S/m, measured in air without any surface cleaning steps, which is a very good value and comparable to bulk copper conductivity in the millimeter-wave range.- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 69 (11) , 6358-6361
A 3-D Printed Helix for Traveling-Wave Tubes
In this work, a 3-D printed copper helix for a traveling-wave tube (TWT) is reported. The fabricated helix was designed to be used in a TWT operating at millimeter-wave frequencies (60–80 GHz). The helix was realized with an additive micromanufacturing technique ($\mu $ AM). Measurements were also performed to estimate the losses of the printed material and evaluate the RF performance of deposited copper. Simulations showed that a TWT based on the 3-D printed helix can have a gain of about 30 dB at 66 GHz and a 1-dB bandwidth of about 5 GHz. The estimated losses from RF measurements reveal an RF copper conductivity of about$2\times 10^{{7}}$ S/m, measured in air without any surface cleaning steps, which is a very good value and comparable to bulk copper conductivity in the millimeter-wave range.- 21 December 2021
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 40 (1) , 014201
Magnetron co-sputtered μm-thick Mo–Cu films as structural material with low heat extension for key parts of high-power millimeter-band vacuum microelectronic devices
The development of high-power millimeter and THz-band vacuum microelectronic devices (μVEDs) demands structural materials with special properties. In particular, key components of μVEDs must retain their dimensions when heated while operating at higher power levels. A molybdenum-copper alloy is a promising material, thanks to the low thermal expansion of molybdenum and the remarkable thermal and electrical conductivity of copper. However, such alloys can only be obtained by a limited number of techniques that are rather complicated. Thus, the goal of this work is the implementation of vacuum magnetron co-deposition as a facile method in the fabrication of μm-thick Mo–Cu films. Such films are very promising for the microfabrication of microstrip slow-wave structures for high-power millimeter and THz-band μVEDs. This study is focused on controlling the morphology, resistivity, and roughness of the fabricated thin films by changing the deposition process parameters, such as the sputtered Cu and Mo ratio and substrate temperature.
- 21 December 2021
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 40 (1) , 014201
Magnetron co-sputtered μm-thick Mo–Cu films as structural material with low heat extension for key parts of high-power millimeter-band vacuum microelectronic devices
The development of high-power millimeter and THz-band vacuum microelectronic devices (μVEDs) demands structural materials with special properties. In particular, key components of μVEDs must retain their dimensions when heated while operating at higher power levels. A molybdenum-copper alloy is a promising material, thanks to the low thermal expansion of molybdenum and the remarkable thermal and electrical conductivity of copper. However, such alloys can only be obtained by a limited number of techniques that are rather complicated. Thus, the goal of this work is the implementation of vacuum magnetron co-deposition as a facile method in the fabrication of μm-thick Mo–Cu films. Such films are very promising for the microfabrication of microstrip slow-wave structures for high-power millimeter and THz-band μVEDs. This study is focused on controlling the morphology, resistivity, and roughness of the fabricated thin films by changing the deposition process parameters, such as the sputtered Cu and Mo ratio and substrate temperature.
- 1 January 2021
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 39 (1) , 013204
Development of microfabricated planar slow-wave structures on dielectric substrates for miniaturized millimeter-band traveling-wave tubes
We report the results of the design, simulation, fabrication, and cold-test measurements of millimeter-band 2D planar microstrip slow-wave structures (SWSs) on dielectric substrates. Such structures have a high slow-wave factor, which allows for low-voltage operation and reduction in the size and weight of the device. A low-cost and flexible fabrication technology based on magnetron sputtering and subsequent laser ablation has been developed and is reported in the paper. Microstrip meander-line SWS circuits at V-, W-, and D-bands have been fabricated and characterized. The fabrication of ring-bar planar SWSs by the photolithographic method is also discussed. Experimental measurement of S-parameters of the fabricated structures reveals good transmission properties. Return loss (S11) does not exceed −10 dB and attenuation is about 2 dB/cm in the V-band, 10 dB/cm in the W-band, and 8.5 dB/cm in the D-band.
- 1 January 2021
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 39 (1) , 013204
Development of microfabricated planar slow-wave structures on dielectric substrates for miniaturized millimeter-band traveling-wave tubes
We report the results of the design, simulation, fabrication, and cold-test measurements of millimeter-band 2D planar microstrip slow-wave structures (SWSs) on dielectric substrates. Such structures have a high slow-wave factor, which allows for low-voltage operation and reduction in the size and weight of the device. A low-cost and flexible fabrication technology based on magnetron sputtering and subsequent laser ablation has been developed and is reported in the paper. Microstrip meander-line SWS circuits at V-, W-, and D-bands have been fabricated and characterized. The fabrication of ring-bar planar SWSs by the photolithographic method is also discussed. Experimental measurement of S-parameters of the fabricated structures reveals good transmission properties. Return loss (S11) does not exceed −10 dB and attenuation is about 2 dB/cm in the V-band, 10 dB/cm in the W-band, and 8.5 dB/cm in the D-band.
- Open Access
- 29 August 2020
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 41 (12) , 1469-1477
Design and Realization of a Band Pass Filter at D-band Using Gap Waveguide Technology
Gap waveguide technology is particularly attractive for the design of passive elements in mm-wave systems. Recently, the so-called zero-gap implementation has proved to be very robust to manufacturing tolerances, while at the same time keeping the low loss associated to the contactless standard gap waveguide. In this paper, a Chebyshev filter working at 145 GHz based on this idea and intended to be used in a wireless communication system is designed and optimized. A conventional milling technique has been used in its fabrication, and good measured results have been obtained in a single-pass process.
- 29 August 2020
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 41 (12) , 1469-1477
Open AccessDesign and Realization of a Band Pass Filter at D-band Using Gap Waveguide Technology
Gap waveguide technology is particularly attractive for the design of passive elements in mm-wave systems. Recently, the so-called zero-gap implementation has proved to be very robust to manufacturing tolerances, while at the same time keeping the low loss associated to the contactless standard gap waveguide. In this paper, a Chebyshev filter working at 145 GHz based on this idea and intended to be used in a wireless communication system is designed and optimized. A conventional milling technique has been used in its fabrication, and good measured results have been obtained in a single-pass process.
- 29 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 67 (7) , 2919-2924
Technology, Assembly, and Test of a W-Band Traveling Wave Tube for New 5G High-Capacity Networks
The folded waveguide (FWG) traveling wave tube (TWT) developed in the frame of the Horizon 2020 TWEETHER project for enabling a novel W-band (92-95 GHz) high capacity wireless network for 5G is presented. The FWG TWT was designed by particle-in-cell (PIC) simulations. The technology and the results in terms of measured RF losses and beam transmission from the realized beam tester are presented. Amplification on the first TWT breadboard has been observed but with a poor multireflection pattern resulting from spurious burrs inside the FWG. It indicates, however, that the FWG technology offers great manufacturing simplification compared to conventional helix TWTs, thus enabling a low-cost device with large series production suitable for the wide market of wireless communications.
- 29 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 67 (7) , 2919-2924
Technology, Assembly, and Test of a W-Band Traveling Wave Tube for New 5G High-Capacity Networks
The folded waveguide (FWG) traveling wave tube (TWT) developed in the frame of the Horizon 2020 TWEETHER project for enabling a novel W-band (92-95 GHz) high capacity wireless network for 5G is presented. The FWG TWT was designed by particle-in-cell (PIC) simulations. The technology and the results in terms of measured RF losses and beam transmission from the realized beam tester are presented. Amplification on the first TWT breadboard has been observed but with a poor multireflection pattern resulting from spurious burrs inside the FWG. It indicates, however, that the FWG technology offers great manufacturing simplification compared to conventional helix TWTs, thus enabling a low-cost device with large series production suitable for the wide market of wireless communications.
- Open Access
Early, Non-Invasive Sensing of Sustained Hyperglycemia in Mice Using Millimeter-Wave Spectroscopy
Diabetes is a very complex condition affecting millions of people around the world. Its occurrence, always accompanied by sustained hyperglycemia, leads to many medical complications that can be greatly mitigated when the disease is treated in its earliest stage. In this paper, a novel sensing approach for the early non-invasive detection and monitoring of sustained hyperglycemia is presented. The sensing principle is based on millimeter-wave transmission spectroscopy through the skin and subsequent statistical analysis of the amplitude data. A classifier based on functional principal components for sustained hyperglycemia prediction was validated on a sample of twelve mice, correctly classifying the condition in diabetic mice. Using the same classifier, sixteen mice with drug-induced diabetes were studied for two weeks. The proposed sensing approach was capable of assessing the glycemic states at different stages of induced diabetes, providing a clear transition from normoglycemia to hyperglycemia typically associated with diabetes. This is believed to be the first presentation of such evolution studies using non-invasive sensing. The results obtained indicate that gradual glycemic changes associated with diabetes can be accurately detected by non-invasively sensing the metabolism using a millimeter-wave spectral sensor, with an observed temporal resolution of around four days. This unprecedented detection speed and its non-invasive character could open new opportunities for the continuous control and monitoring of diabetics and the evaluation of response to treatments (including new therapies), enabling a much more appropriate control of the condition.
Open AccessEarly, Non-Invasive Sensing of Sustained Hyperglycemia in Mice Using Millimeter-Wave Spectroscopy
Diabetes is a very complex condition affecting millions of people around the world. Its occurrence, always accompanied by sustained hyperglycemia, leads to many medical complications that can be greatly mitigated when the disease is treated in its earliest stage. In this paper, a novel sensing approach for the early non-invasive detection and monitoring of sustained hyperglycemia is presented. The sensing principle is based on millimeter-wave transmission spectroscopy through the skin and subsequent statistical analysis of the amplitude data. A classifier based on functional principal components for sustained hyperglycemia prediction was validated on a sample of twelve mice, correctly classifying the condition in diabetic mice. Using the same classifier, sixteen mice with drug-induced diabetes were studied for two weeks. The proposed sensing approach was capable of assessing the glycemic states at different stages of induced diabetes, providing a clear transition from normoglycemia to hyperglycemia typically associated with diabetes. This is believed to be the first presentation of such evolution studies using non-invasive sensing. The results obtained indicate that gradual glycemic changes associated with diabetes can be accurately detected by non-invasively sensing the metabolism using a millimeter-wave spectral sensor, with an observed temporal resolution of around four days. This unprecedented detection speed and its non-invasive character could open new opportunities for the continuous control and monitoring of diabetics and the evaluation of response to treatments (including new therapies), enabling a much more appropriate control of the condition.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Monitoring the evolution of hyperglycemia in mice using mm-wave spectroscopy
It was very recently demonstrated that mm-wave spectroscopy, in the range between 75 GHz and 110 GHz, provides the means for the non-invasive, in-vivo detection of hyperglycemia-associated conditions in mice. This mm-wave spectrometer in conjunction with Principal Component Analysis clearly differentiated, on a single day measurement, between several hyperglycemic states. In this work, using the same set-up, we will focus on the study of the feasibility of dynamically detecting and monitoring the evolution of hyperglycemia on mice with diabetes-induced conditions.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Monitoring the evolution of hyperglycemia in mice using mm-wave spectroscopy
It was very recently demonstrated that mm-wave spectroscopy, in the range between 75 GHz and 110 GHz, provides the means for the non-invasive, in-vivo detection of hyperglycemia-associated conditions in mice. This mm-wave spectrometer in conjunction with Principal Component Analysis clearly differentiated, on a single day measurement, between several hyperglycemic states. In this work, using the same set-up, we will focus on the study of the feasibility of dynamically detecting and monitoring the evolution of hyperglycemia on mice with diabetes-induced conditions.
- Open Access
- 11 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 38 (1) , 126-129
$W$ -Band Traveling Wave Tube Amplifier Based on Planar Slow Wave Structure
A novel planar slow wave structure (SWS) for traveling wave tube (TWT) is proposed. The major advantage of the planar architecture is its easy realization with respect to the typical 3-D SWSs. The particle in cell simulations of the TWT show an achievable gain up to 36.4 dB and a maximum output power of 17.4 W for an operating frequency of 92 GHz. The planar structure can be realized using the standard photolithographic techniques, which improve the reproducibility and performance.
- 11 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 38 (1) , 126-129
Open Access$W$ -Band Traveling Wave Tube Amplifier Based on Planar Slow Wave Structure
A novel planar slow wave structure (SWS) for traveling wave tube (TWT) is proposed. The major advantage of the planar architecture is its easy realization with respect to the typical 3-D SWSs. The particle in cell simulations of the TWT show an achievable gain up to 36.4 dB and a maximum output power of 17.4 W for an operating frequency of 92 GHz. The planar structure can be realized using the standard photolithographic techniques, which improve the reproducibility and performance.