SASara Albasini

Sara Albasini

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sara Albasini has a total of 137 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Regional nodal irradiation might not improve locoregional recurrence-free survival in ypN0 breast cancer patients undergoing neoadjuvant chemotherapy

    by Luca Sorrentino, Sara Albasini, Maria Luisa Gasparri, Carlo Morasso, Valentina Zanella, Daniela Bossi, Seyedeh Negin Sadat Madarshahi, Marco Lunghi, Marta Sevieri, Beatrice Bignami, et al.

  • Open Access

    FAIRaman: making clinical Raman spectroscopy data FAIR through biobanking and NeXus standards

    by Davide Piccapietra, Mahin Vazifehdan, Arianna Bonizzi, Seyedeh Negin Sadat Madarshahi, Francesca Piccotti, Marta Truffi, Sara Albasini, Fabio Corsi, Carlo Francesco Morasso

    Raman spectroscopy is increasingly applied in biomedical and diagnostic research, generating spectral datasets that could support the development of robust artificial intelligence (AI) models for disease diagnosis, prognosis, and treatment guidance. However, most clinical Raman datasets remain difficult to reuse across laboratories because spectra are often stored separately from structured metadata describing the samples, their clinical context, experimental conditions, and data governance. This limits reproducibility, external validation, multicentre integration, and the development of transferable models. Here, we introduce FAIRaman, a FAIR-by-design framework and open-source software tool for the structured organisation of clinical Raman spectroscopy data. FAIRaman combines the hierarchical logic of the Investigation–Study–Assay (ISA) model with biobanking-derived descriptors for sample, donor, and processing-event annotation, and with NeXus/NXraman-inspired metadata for Raman acquisition parameters and spectral data. The resulting structure implemented in the open HDF5 file format. The software, developed in Python, converts native Renishaw WDF files and vendor-neutral text-based spectral files into FAIRaman-compliant HDF5 files through a graphical user interface (GUI), allowing users to combine batch-level metadata with sample-specific clinical data. We demonstrate the framework using a real Raman map of breast cancer tissue, and a Raman spectrum acquired from plasma-derived extracellular vesicles. These examples show that spectral data, acquisition metadata, and clinical sample descriptors can be stored within a single structured file and that the stored information can be easily retrieved using independent, freely available software tools.

  • Open Access

    FAIRaman: making clinical Raman spectroscopy data FAIR through biobanking and NeXus standards

    by Davide Piccapietra, Arianna Bonizzi, Mahin Vazifehdan, Seyedeh Negin Sadat Madarshahi, Francesca Piccotti, Marta Truffi, Sara Albasini, Fabio Corsi, Carlo Francesco Morasso

    Raman spectroscopy is increasingly applied to biomedical and diagnostic research, generating spectral datasets that could support the development of robust artificial-intelligence models for disease diagnosis, prognosis, and treatment guidance. However, most clinical Raman datasets remain difficult to reuse across laboratories because spectra are often stored separately from structured information on sample characteristics, provenance, donor context, pre-analytical processing, acquisition parameters, and data governance. This limits reproducibility, external validation, multicentre integration, and the development of transferable models. Here, we introduce FAIRaman, a FAIR-by-design framework and open-source software tool for the structured organisation of clinical Raman spectroscopy data. FAIRaman combines the hierarchical logic of the Investigation–Study–Assay model with biobanking-derived descriptors for sample, donor, and processing-event annotation, and NeXus/NXraman-inspired metadata for Raman acquisition parameters and spectral data. The resulting structure is implemented in open HDF5 files. The software, developed in Python, converts native Renishaw WDF files and vendor-neutral textbased spectral files into FAIRaman-compliant HDF5 files through a graphical interface, allowing users to combine batch-level metadata with sample-specific clinical associated data. We demonstrate the framework using a real Raman map of breast cancer tissue, and a spectrum from a sample of plasma-derived extracellular vesicles showing that spectral data, acquisition metadata, and clinical sample descriptors can be stored in a single structured file and that the information can be easily recovered using independent free software tools.


  • Open Access

    Post‐Neoadjuvant Chemotherapy Axillary Ultrasound in cN + Breast Cancer: Can It Reliably Support de‐Escalation of Axillary Surgery?

    by Sara Albasini, Camilla Rossetti, Roberta Brancaccio, Elena Orvieto, Daniela Bossi, Matilde Pelizzola, Marta Truffi, Serena Mazzucchelli, Valentina Zanella, Arianna Bonizzi, et al.

    Background: Neoadjuvant chemotherapy (NAC) in up to 40%–60% of node‐positive (cN+) breast cancer patients allows nodal pathological complete response, particularly in Her2+ and triple‐negative subtypes. Accurate post‐NAC axillary restaging is therefore critical to identify candidates for surgical de‐escalation. Axillary ultrasound (AUS) remains the most widely used tool, but prior studies report highly variable performance, with false‐negative rates approaching 25%, raising concerns about its reliability as a standalone guide. Methods: We retrospectively evaluated 413 patients with biopsy‐proven cN+ breast cancer treated with NAC (2000–2024). All underwent AUS before surgery. AUS results (ycN0 vs. ycN+) were compared with final pathology (ypN0 vs. ypN+). Diagnostic performance was assessed, and predictors of false‐negative AUS were identified using logistic regression. Results: AUS classified 51.6% of patients as ycN0, whereas only 45% achieved nodal pathologic complete response. Overall, AUS demonstrated 68% sensitivity, 76% specificity, 72% accuracy, positive predictive value 78%, and negative predictive value 66%. Performance differed by subtype: accuracy was highest in ER‐/Her2 tumors (75%), but markedly lower in Her2+ (69%) and lobular carcinoma (67%). On multivariate analysis, absence of breast clinical complete response (OR 2.38, 95% CI [1.14–4.93]) independently predicted false‐negative AUS findings. Conclusions: AUS following NAC provides only moderate accuracy, with a clinically relevant risk in patients lacking breast response. AUS alone should not determine omission of axillary surgery. A multimodal, biology‐informed strategy combining AUS with other imaging techniques is needed to safely guide axillary de‐escalation and minimize both overtreatment and undertreatment.


  • Open Access

    Comparative effectiveness of preoperative localization techniques for non-palpable breast lesions: multicentre real-world study

    by Fabio Corsi, Sara Albasini, Matilde Pelizzola, Carlo Morasso, Giulia Armatura, Alessandro Asaro, Corrado Chiappa, Virginia Coli, Francesca Combi, Angelica Della Valle, et al.

    Background: The increasing detection of non-palpable breast lesions has made accurate preoperative localization essential to optimize breast-conserving surgery. Although multiple localization methods exist, there is still a lack of robust, large-scale, multicentre evaluations comparing different techniques. Methods: The LOCALIZATION01 study compares real-world data from 13 breast units in Italy and Switzerland on the impact of localization techniques on breast-conserving surgery for non-palpable lesions between 2016 and 2024. Four localization techniques were compared: wire-guided (WGL), radio-guided (ROLL), magnetic seed (MSL), and carbon (CL). The main outcomes were margin status, calculated resection ratio, postoperative complications, and surgical time. Subgroup analyses were performed for body mass index, lesion morphology and histopathology. Results: In total, 3241 patients were enrolled (ROLL 985, MSL 592, WGL 1079, and CL 585). ROLL achieved the highest rate of negative surgical margins, significantly outperforming MSL, WGL, and CL (97.5% versus 94.7% versus 94.5% versus 90.6%, respectively; P < 0.05). CL was associated with the highest postoperative complications rate (16.7%) versus ROLL (4.1%), MSL (4.5%), and WGL (2.1%) (P < 0.0001). The surgical time for MSL was significantly shorter when compared with WGL (46 versus 70 minutes (min); P < 0.0001) and CL (55 min; P < 0.0001). WGL had the most favourable calculated resection ratio (2.4), followed by MSL (2.6), ROLL (2.7), and CL (3.0). Multivariable analysis identified CL as an independent predictor of positive margins (odds ratio 1.82; P = 0.004), whereas ROLL was protective (odds ratio 0.45; P = 0.009). Conclusion: ROLL and MSL outperformed WGL and CL across multiple endpoints. CL data revealed objective limitations that suggest caution in its use. A personalized approach considering lesion morphology, body mass index, and logistics is recommended.


  • Open Access

    Influence of Isolation Techniques on the Quality of Plasma Samples: Implications for Cancer Biobanking

    by Francesca Piccotti, Fiorella Treviso, Carlo Morasso, Nadia Pittatore Leone, Antonella Navarra, Sara Albasini, Arianna Bonizzi, Ilaria Tagliolini, Francesca Gorgoglione, Fabio Corsi, et al.

    Biobanks are essential for precision oncology, providing high-quality materials for biomedical research. Liquid biopsy has become a key tool for non-invasive detection of tumor-derived biomarkers, including circulating tumor DNA, proteins, and extracellular vesicles. However, the reliability of these assays critically depends on standardized preanalytical procedures. In this study, we evaluated the impact of two plasma isolation methods—direct centrifugation (DC) and density gradient centrifugation (DGC)—on the overall quality of breast cancer samples collected at the Bruno Boerci Biobank (Maugeri, Italy). Plasma obtained with the two methods was analyzed by spectrometry for hemolysis and lipemia, biochemical analysis for protein and lipoprotein composition, flow cytometry for cellular debris and platelet contamination. Preanalytical nonconformities due to hemolysis, icterus, and lipemia were comparable between methods. However, DGC was associated with a higher platelet contamination and reduced albumin and cholesterol levels. Inter-individual variability was preserved, supporting the robustness of patient-specific molecular signatures, despite absolute discrepancies. This study highlights the pivotal role of the isolation techniques in shaping the quality and overall composition of plasma samples. Harmonized, “fit-for-purpose” biobanking protocols are required to ensure reproducibility of downstream analyses, support biomarker discovery, and ultimately advance the identification of novel therapeutic targets in cancer.


  • Open Access

    Membrane Sensing Peptides -Enhanced SiMoA Platform for the Detection of HER2 on Extracellular Vesicles in Metastatic Breast Cancer Patients

    by Arianna Bonizzi, Paola Gagni, Francesca Piccotti, Marta Truffi, Sara Albasini, Serena Mazzucchelli, Lorena Signati, Tiziana Triulzi, Elda Tagliabue, Alessandro Gori, et al.

    Extracellular vesicles (EVs) offer a promising avenue for non-invasive, real-time monitoring of metastatic breast cancer (mBC), but clinical application as a liquid biopsy is hindered by their heterogeneity and low abundance. Here we present a Single Molecule Array (SiMoA) platform enhanced by membrane sensing peptides (MSP) for the highly sensitive detection of HER2 on EV membranes (EVs-HER2) and general EVs population (CD9+) directly from plasma samples of mBC patients. The MSP-based SiMoA assay demonstrated superior sensitivity and specificity compared to conventional antibody-based assays, allowing the detection of lower amounts of EVs and discriminating EVs derived from breast cancer patient-derived organoids (BC-PDO) from healthy control-derived organoids (HC-PDO). Concerning the analysis of EVs in plasma samples (n=49 mBC patients, n=30 healthy controls), we observed significantly lower CD9+ EVs levels in mBC patients relative to healthy controls, a trend consistently confirmed across assays. Notably, EVs-HER2 levels were significantly enriched in HER2-positive patients and correlated with clinical HER2 status assessed by immunohistochemistry. Besides, lower CD9+ EVs levels were associated with poorer clinical outcomes, highlighting the potential prognostic utility of EV quantification. Our findings underscore the potential of MSP-enhanced SiMoA platforms for accurate, minimally invasive monitoring of EVs-HER2 in mBC and for monitoring CD9+ EVs levels to assess disease progression.

  • Open Access

    Exploring breast cancer-related biochemical changes in circulating extracellular vesicles using Raman spectroscopy

    by Arianna Bonizzi, Lorena Signati, Maria Grimaldi, Marta Truffi, Francesca Piccotti, Stella Gagliardi, Giulia Dotti, Serena Mazzucchelli, Sara Albasini, Roberta Cazzola, et al.


  • Open Access

    Exploring Breast Cancer-Related Biochemical Changes in Circulating Extracellular Vesicles Using Raman Spectroscopy

    by Arianna Bonizzi, Lorena Signati, Maria Grimaldi, Marta Truffi, Francesca Piccotti, Stella Gagliardi, Giulia Dotti, Serena Mazzucchelli, Sara Albasini, Roberta Cazzola, et al.

    Extracellular vesicles (EVs) are a subgroup of the circulating particles, released by cells in both normal and diseased states, carrying active biomolecules. They have gained significant attention as potential cancer biomarkers, particularly in breast cancer (BC). Previous research showed variations in EVs content and quantity between BC patients and healthy controls (HC). However, studying EVs biochemical profile remains challenging due to their low abundance and complex composition. Additionally, EVs may interact with other plasma components, like lipoproteins (LPs), forming a so called “biomolecular corona” that further complicates their analysis. Here, Raman spectroscopy (RS) is proposed as a fast tool to obtain the biochemical profile of circulating EVs in the context of BC. RS was employed to differentiate various extracellular particles (EPs) in blood, including LPs and EVs. The study also evaluated RS’s capability to quantify major classes of biomolecules and compared these results with those obtained by traditional biochemical assays. Finally, compositional differences in large EVs (lEVs) and small EVs (sEVs) were assessed between 30 HC and 34 BC patients. RS revealed the existence of distinct biochemical signatures associated with BC, highlighting increased levels of nucleic acids and lipids in the BC group.