TGTakeshi Goto

Takeshi Goto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takeshi Goto has a total of 187 co-authors. Here are the top co-authors by number of shared publications:

  • Ikuo Fukuda

    Department of Thoracic and Cardiovascular Surgery, Hirosaki University School of Medicine, Hirosaki, Aomori, Japan

    5 shared publications
  • Junko Ogasawara

    Department of Clinical Engineering Hirosaki University School of Medicine and Hospital Hirosaki Japan

    5 shared publications
  • Kazuyuki Daitoku

    Department of Thoracic and Cardiovascular Surgery, Hirosaki University School of Medicine, Hirosaki, Aomori, Japan

    4 shared publications
  • Masahito Minakawa

    Department of Thoracic and Cardiovascular Surgery, Hirosaki University School of Medicine, Hirosaki, Aomori, Japan

    4 shared publications
  • Hiroyuki Hanada

    Department of Emergency and Disaster Medicine Hirosaki University Hirosaki Aomori Japan

    3 shared publications
  • Minori Shirota

    Graduate School of Science and Technology, Hirosaki University, Hirosaki, Japan

    3 shared publications

Latest Publications

  • Open Access

    Machine Learning‐Based Prediction of Life‐Threatening Complications During Hemodialysis in Hospitalized Patients With Poor General Conditions

    by Naotaka Kato, Takeshi Goto, Tomoyuki Ohira, Hirotaka Kinoshita, Kugo Kurokawa, Kouhei Naganuma, Chikako Ohminato, Junko Ogasawara, Shingo Hatakeyama, Yoshihiro Sasaki, et al.

    Background: Patients undergoing hemodialysis (HD) face a significantly elevated risk of cardiovascular mortality, with sudden events during treatment posing a critical threat to survival. These risks are particularly pronounced in high‐risk populations, such as patients recovering from cardiovascular surgery or those being treated for sepsis. Therefore, the development of effective preventive strategies is essential for improving patient outcomes. This study aimed to develop a machine learning model that uses pretreatment patient characteristics to predict sudden adverse events during HD and within 24 h after treatment in high‐risk inpatients at acute care hospitals. Methods: His retrospective study analyzed data from 739 patients who underwent HD at Hirosaki University Hospital between 2018 and 2021. Sudden events were defined as fatal arrhythmia, refractory intradialytic hypotension, or respiratory arrest. A logistic regression model was constructed using backward stepwise selection from 51 patient characteristics (demographic data, clinical parameters, laboratory data, and HD‐related information). Results: Among the 739 patients, 17 (2.3%) experienced sudden events. The model identified 23 pre‐HD covariates and achieved an area under the receiver operating characteristic curve (AUC) of 0.889. Key covariates included emergency hospitalization (present in 71% of patients with sudden events), recent surgery (76%), shorter HD history, elevated pre‐HD heart rate, lower serum albumin levels, and higher C‐reactive protein concentrations. Conclusions: Our model enables the early identification of high‐risk inpatients receiving hemodialysis using pre‐dialysis data, thereby supporting timely clinical interventions, optimized resource allocation, and improved patient safety.


  • Open Access

    A Novel Technique for Diaphragmatic Compound Motor Action Potential Monitoring Using the BeeAT Catheter During Cryoballoon Ablation for Atrial Fibrillation

    by Keigo Yamamoto, Takeshi Goto, Masaomi Kimura

    Background: Diaphragmatic compound motor action potential (CMAP) monitoring helps prevent phrenic nerve palsy during cryoballoon ablation (CBA) for atrial fibrillation. Methods: This retrospective analysis included 95 patients who had undergone CBA. Phrenic nerve pacing was performed via the distal electrode of a BeeAT catheter positioned in the right subclavian vein, with CMAPs recorded from the most proximal electrode in the subdiaphragmatic inferior vena cava. Results: CMAP amplitude was unaffected by patient body habitus (mean: 1.14 ± 0.58 mV; CMAP‐to‐ventricular wave ratio: 8.76). Conclusions: This technique provides stable, well‐defined signals with minimal artifacts, enhancing the reliability of CMAP monitoring during CBA.


  • Open Access

    Positive emotions for promoting quality improvement of extracorporeal membrane oxygenation therapy for COVID‐19: In situ interprofessional simulation

    by Osamu Nomura, Arisa Aoyagi, Jin Irie, Takeshi Goto, Kana Sugiyama, Hiroyuki Hanada, Yoshiya Ishizawa

    Aim: The requirement during the COVID‐19 pandemic to provide extracorporeal membrane oxygenation (ECMO) treatment regardless of experience caused high levels of anxiety among healthcare professionals. The aim of the present study was to evaluate the effectiveness of an in situ interprofessional simulation training conducted to improve readiness and preparedness for ECMO management of patients with COVID‐19 at a non‐high‐volume ECMO centre.Methods: Three emergency physicians, three clinical engineers and two nurses attended the 3‐h simulation held at Hirosaki University Hospital in December 2021, during the COVID‐19 pandemic. The training comprised a 30‐min briefing, a 1‐h ECMO circuit change session, a 1‐h in‐hospital transfer simulation for CT and a 30‐min debriefing. Before and after the training, participants completed an online survey of their emotions, based on the Japanese version of the Medical Emotion Scale (J‐MES). Related‐samples Wilcoxon signed rank test was used to assess potential changes in emotional responses before and after the simulation, and p < 0.05 was considered to indicate significance.Results: Participants' positive deactivating emotions increased from a median of 3.3 (range, 2.0–4.5) before the simulation to 4.0 (range, 2.5–5.0) after the simulation (p = 0.02), which indicates favourable performance according to the control value theory of educational psychology. There was no statistically significant change in other emotional categories.Conclusion: Participants' positive deactivating emotions increased significantly following an in situ ECMO simulation training, which indicates the efficacy of the training for improving the quality of ECMO management in patients with COVID‐19.


  • Open Access

    Early Initiation of Venovenous Extracorporeal Membrane Oxygenation for Critically Ill COVID-19 Patients

    by Takeshi Goto, Shinya Yaguchi, Junko Ogasawara, Naotaka Kato, Jin Irie, Hiroaki Ichikawa, Yuki Nishiya, Yoshiya Ishizawa, Osamu Nomura, Hiroyuki Hanada

    The optimal timing for initiating extracorporeal membrane oxygenation (ECMO) after starting mechanical ventilation has yet to be clarified. We report herein the cases of two patients with coronavirus disease 2019 (COVID-19) acute respiratory distress syndrome (ARDS) who were successfully managed with an early ECMO induction strategy. Case 1 involved a 64-year-old man admitted in respiratory distress with polymerase chain reaction–confirmed COVID-19. On day 5 at hospital, he was intubated, but oxygenation remained unimproved despite mechanical ventilation treatment with high positive end-expiratory pressure (PEEP) (PaO2/FiO2 [P/F] ratio, 127; Respiratory ECMO Survival Prediction [RESP] score, 4). ECMO was initiated 4 hours after intubation, and stopped on day 16 at hospital. The patient was discharged from hospital on day 36. Case 2 involved a 49-year-old man who had been admitted 8 days prior. He was intubated on hospital on day 2. High PEEP mechanical ventilation did not improve oxygenation (P/F ratio, 93; RESP score, 7). ECMO was stopped on hospital on day 7 and he was discharged from hospital on day 21. The strategy of early initiation of ECMO in these two cases may have minimized the risk of ventilation-related lung injury and contributed to the achievement of favorable outcomes.


    • 1 March 2022
      • Vol. 54  (1) , 79-82

    Early Initiation of Venovenous Extracorporeal Membrane Oxygenation for Critically Ill COVID-19 Patients.

    by Takeshi Goto, Shinya Yaguchi, Junko Ogasawara, Naotaka Kato, Jin Irie, Hiroaki Ichikawa, Yuki Nishiya, Yoshiya Ishizawa, Osamu Nomura, Hiroyuki Hanada

    The optimal timing for initiating extracorporeal membrane oxygenation (ECMO) after starting mechanical ventilation has yet to be clarified. We report herein the cases of two patients with coronavirus disease 2019 (COVID-19) acute respiratory distress syndrome (ARDS) who were successfully managed with an early ECMO induction strategy. Case 1 involved a 64-year-old man admitted in respiratory distress with polymerase chain reaction-confirmed COVID-19. On day 5 at hospital, he was intubated, but oxygenation remained unimproved despite mechanical ventilation treatment with high positive end-expiratory pressure (PEEP) (PaO2/FiO2 [P/F] ratio, 127; Respiratory ECMO Survival Prediction [RESP] score, 4). ECMO was initiated 4 hours after intubation, and stopped on day 16 at hospital. The patient was discharged from hospital on day 36. Case 2 involved a 49-year-old man who had been admitted 8 days prior. He was intubated on hospital on day 2. High PEEP mechanical ventilation did not improve oxygenation (P/F ratio, 93; RESP score, 7). ECMO was stopped on hospital on day 7 and he was discharged from hospital on day 21. The strategy of early initiation of ECMO in these two cases may have minimized the risk of ventilation-related lung injury and contributed to the achievement of favorable outcomes.


  • Directing a dispersion cannula tip toward the aortic root during thoracic aortic arch surgery does not adversely affect cardiac function

    by Yuki Imamura, Ryosuke Kowatari, Yoshiaki Saito, Takeshi Goto, Kazuyuki Daitoku, Norihiro Kondo, Masahito Minakawa, Ikuo Fukuda

    Introduction: Neurologic complications of open thoracic aortic surgery are devastating problems in patients with severely diseased aortas. This study aimed to clarify whether directing the aortic cannula tip toward the aortic root affects the postoperative cardiac function in patients undergoing open thoracic aortic surgery. Methods: A total of 16 patients who underwent total or partial arch replacement between January 2014 and April 2019 were enrolled and divided into two groups. Ascending aorta perfusion was performed by placing the cannula tip toward the aortic root (reversed direction group, seven patients) or toward the aortic arch (standard direction group, nine patients). Intraoperative and perioperative data, including mortality, morbidity, and postoperative cardiac function, were compared between the groups. Results: There were no hospital deaths or stroke events in either group. The aortic cross-clamping time was 102.4 ± 20.3 minutes in the reversed direction group and 87.1 ± 9.9 minutes in the standard direction group (p = 0.049). Furthermore, the intubation time was 28.4 ± 12.9 hours in the reversed direction group and 12.4 ± 6.8 hours in the standard direction group (p = 0.022). Both times were significantly longer in the reverse direction group. Postoperative serum creatine kinase-MB levels were significantly lower in the reversed direction group (6.2 ± 3.3 U/L vs 13.3 ± 4.8 U/L, respectively, p = 0.006). The cardiac output and cardiac index did not significantly differ. Conclusions: Directing the aortic cannula tip toward the aortic root does not adversely affect the postoperative cardiac function after aortic arch surgery.


  • Flow analysis during mock circulation in normal and aortic arch aneurysm models through an aortic cannula toward the aortic arch and root

    by Takeshi Goto, Ikuo Fukuda, Takao Inamura, Minori Shirota, Masahito Minakawa

    The aim of this study was to elucidate flow patterns of two different types of aortic cannulas inserted from the ascending aorta toward the aortic arch and root by mock circulation in a normal aortic arch and an aortic arch aneurysm model. Extracorporeal circulation was established using a centrifugal pump, a transparent glass normal aortic arch model, and an aortic arch aneurysm model for measurement by particle image velocimetry. The Stealthflow and Dispersion cannulas were used to elucidate the characteristics of the flow pattern and velocity under the condition of the cannula tip toward the aortic arch and aortic root. In the normal aortic arch model, high-velocity exit flow ranging from 0.7 to 0.8 m/s was detected in the proximal aortic arch by directing the cannula tip toward the aortic arch, whereas flow velocity in the aortic arch was < 0.2 m/s by directing the cannula tip toward the aortic root. In the aortic arch aneurysm model, high-velocity exit flow ranging from 0.5 to 0.8 m/s was detected in the aortic arch by directing the cannula tip toward the aortic arch, whereas flow velocity in the aortic arch was decreased to less than 0.2 m/s by directing the cannula tip toward the aortic root. Directing the aortic cannula tip toward the aortic root allowed the high-velocity exit flow to attenuate in velocity, so that flow velocity in the aortic arch was sufficiently reduced by reversed flow and vortex formation in both the normal and aortic arch aneurysm models.


  • The utility of extracorporeal membrane oxygenation in patients with circulatory collapse by electrical storm

    by Keigo Yamamoto, Takeshi Goto, Tomoyuki Ohira, Ryutaro Kato, Yukiya Konno, Kaori Aoki, Junko Ogasawara, Masaomi Kimura, Masahito Minakawa, Ikuo Fukuda

    In patients experiencing electrical storm, intensive care using extracorporeal membrane oxygenation (ECMO) is an efficient treatment to overcome a hemodynamically unstable condition. The aim of this study was to examine the utility of ECMO in patients with circulatory collapse by electrical storm. We retrospectively examined 17 consecutive patients receiving veno-arterial ECMO for electrical storm between January 2016 and December 2018 in our institution. We compared survivors (n = 11) and non-survivors (n = 6). Thirteen were weaned from ECMO, of whom 11 patients (64.7%) survived and were discharged from hospital, while 6 patients died (35.3%). In comparisons between survivors and non-survivors, blood pH before starting ECMO was significantly higher in survivors (pH 7.32) than in non-survivors (pH 6.89, p = 0.027). Blood lactate level was significantly lower in survivors (6.2 mmol/L) than in non-survivors (12.2 mmol/L, p = 0.044). Complications of hypoxic ischemic encephalopathy were found in 4 non-survivors (66.7%), compared to survivors (0%, p = 0.006). Durations of intensive care unit stay and hospital stay were significantly longer in survivors (271 h, 62 days) than in non-survivors (50 h, 3 days, respectively). Outcomes of treatment using ECMO in patients with circulatory collapse due to electrical storm proved satisfactory. Increases in blood lactate level and decreases in blood pH before starting ECMO were thought to be related to mortality due to suspected irreversible organ damage by hypoxia before ECMO.


  • Clinical evaluation of a new dispersive aortic cannula

    by Takeshi Goto, Ikuo Fukuda, Yukiya Konno, Ai Tabata, Tomoyuki Ohira, Ryutaro Kato, Keigo Yamamoto, Junko Ogasawara, Kazuyuki Daitoku, Masahito Minakawa

    Introduction: Cerebral injury is a serious complication in open-heart surgery. Once it occurs, it causes significant disability and death. We developed a novel dispersive aortic cannula named the Stealth Flow cannula and used it as a standard aortic cannula in cardiopulmonary bypass. The aim of this study was to evaluate the efficiency of this aortic cannula. Methods: A total of 182 consecutive patients undergoing cardiac surgery using cardiopulmonary bypass were studied. The patients were divided into two groups: the Soft-Flow cannula group (n = 89) and the Stealth Flow cannula group (n = 93). Patients with a shaggy aortic arch were excluded from this study because the cannulae were inserted at the ascending aorta with a cannula tip directed toward the aortic root in these cases. Patients with multiple arterial perfusion sites were also excluded. Complications including early mortality, perioperative stroke, and intraoperative aortic injury were compared between the two groups. Results: Age, operative procedure, cardiopulmonary bypass time, and the Japan SCORE were not significantly different between the groups. In comparisons between the Stealth Flow and Soft-Flow groups, the incidences of early mortality, perioperative stroke, intraoperative aortic dissection, and all complications were 1.08% versus 1.12% (p = 0.98), 1.1% versus 2.2% (p = 0.53), 0% versus 1.1% (p = 0.33), and 1.1% versus 3.4% (p = 0.29), respectively. The incidence of major cardiovascular events, including early death, perioperative stroke, and aortic dissection, was not different. Conclusions: The Stealth Flow cannula, which was designed based on our previous experimental study, contributed to reducing cerebral and aortic events as much as the Soft-Flow cannula in the present clinical study.


  • Effect of inflow cannula side-hole number on drainage flow characteristics: flow dynamic analysis using numerical simulation

    by Takeshi Goto, Tsubasa Tanabe, Takao Inamura, Minori Shirota, Koji Fumoto, Yoshiaki Saito, Wakako Fukuda, Ikuo Fukuda, Kazuyuki Daitoku, Masahito Minakawa

    Background: Venous drainage in cardiopulmonary bypass is a very important factor for safe cardiac surgery. However, the ideal shape of venous drainage cannula has not been determined. In the present study, we evaluated the effect of side-hole number under fixed total area and venous drainage flow to elucidate the effect of increasing the side-hole numbers. Method: Computed simulation of venous drainage was performed. Cannulas were divided into six models: an end-hole model (EH) and models containing four (4SH), six (6SH), eight (8SH), 10 (10SH) or 12 side-holes (12SH). Total orifice area of the side-holes was fixed to 120 mm2 on each side-hole cannula. The end-hole orifice area was 36.3 mm2. The total area of the side-holes was kept constant when the number of side-holes was increased. Result: The mean venous drainage flow rate of the EH, 4SH, 6SH, 8SH, 10SH and 12SH was 2.57, 2.52, 2.51, 2.50, 2.49, 2.41 L/min, respectively. The mean flow rate decreased in accordance with the increased number of side-holes. Conclusion: We speculate that flow separation at the most proximal site of the side-hole induces stagnation of flow and induces energy loss. This flow separation may hamper the main stream from the end-hole inlet, which is most effective with low shear stress. The EH cannula was associated with the best flow rate and flow profile. However, by increasing side-hole numbers, flow separation occurs on each side-hole, resulting in more energy loss than the EH cannula and flow rate reduction.