DRDaniel San Roman

Daniel San Roman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel San Roman has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Wound state monitoring by multiplexed, electrochemical, real-time, localized, inflammation-tracking nitric oxide sensor (MERLIN)

    by Liyang Wang, Yingqiao Wang, Mabel Bartlett, Daniel San Roman, Gaurav Balakrishnan, Samuel Gershanok, Reem Khan, Clint Skillen, Shanae Butler, Mangesh Kulkarni, et al.

    Nitric oxide (NO) released endogenously by induced NO synthase (iNOS) in macrophages is a key regulatory biomarker for wound inflammation. Detecting NO directly on the wound bed is challenging due to its short half-life time (6 to 50 seconds), low physiological concentration (nanomolar to micromolar), and interferences in the complex wound environment. Here, we present a compliant, multiplexed, electrochemical, real-time, localized, inflammation-tracking NO sensor (MERLIN) array for in vivo spatiotemporal measurement of NO, with high sensitivity (883 ± 283 nanoamperes per micromolar per square centimeter); selectivity against nitrites (~27,900-fold), ascorbic acid (~3800-fold), and uric acid (~6900-fold); and low limit of detection (~8.00 nM). MERLIN spatiotemporally tracked NO on rat skin wounds for 7 days, and results indicated that NO peaks on day 3, in line with previously reported iNOS activity. MERLIN allows spatial mapping of the NO gradient across the wound bed, which can be used to provide diagnostic information to assist wound care.


  • Open Access

    Wound state monitoring by multiplexed, electrochemical, real-time, localized, inflammation-tracking nitric oxide sensor (MERLIN)

    by Liyang Wang, Yingqiao Wang, Mabel Bartlett, Daniel San Roman, Gaurav Balakrishnan, Samuel Gershanok, Reem Khan, Clint Skillen, Shanae Butler, Mangesh Kulkarni, et al.

    Nitric oxide (NO) released endogenously by induced nitric oxide synthase (iNOS) in macrophages is a key regulatory biomarker for wound inflammation. Detecting NO directly on the wound bed is challenging due to its short half-life time (6 – 50 s), low physiological concentration (nM - µM) and interferences in the complex wound environment. Existing NO sensors suffer from limitations such as rigid substrates, single point of detection and complex measurement setup. Here we present a compliant, multiplexed, electrochemical, real-time, localized, inflammation-tracking nitric oxide sensor (MERLIN) array for in vivo spatiotemporal measurement of NO, with high sensitivity (15.6 ± 5.0 nA/μM for 1.5 mm diameter electrodes), selectivity against nitrites (ca. 27900-fold), ascorbic acid (ca. 3800-fold), and uric acid (ca. 6900-fold), and low limit of detection (8.00 nM). We developed a robust device fabrication protocol, comprehensive and highly reproducible in vitro characterization yielding a consistent device performance deployed for wound healing diagnostics. MERLIN spatiotemporally tracked NO on rat skin wounds for 7 days and results indicated that NO peaks on day 3, in line with previously reported iNOS activity. MERLIN allows spatial mapping of the NO gradient across the wound bed, which can be used to provide diagnostic information to assist wound care.

  • Graphene nanostructures for input–output bioelectronics

    by Raghav Garg, Daniel San Roman, Yingqiao Wang, Devora Cohen-Karni, Tzahi Cohen-Karni

    The ability to manipulate the electrophysiology of electrically active cells and tissues has enabled a deeper understanding of healthy and diseased tissue states. This has primarily been achieved via input/output (I/O) bioelectronics that interface engineered materials with biological entities. Stable long-term application of conventional I/O bioelectronics advances as materials and processing techniques develop. Recent advancements have facilitated the development of graphene-based I/O bioelectronics with a wide variety of functional characteristics. Engineering the structural, physical, and chemical properties of graphene nanostructures and integration with modern microelectronics have enabled breakthrough high-density electrophysiological investigations. Here, we review recent advancements in 2D and 3D graphene-based I/O bioelectronics and highlight electrophysiological studies facilitated by these emerging platforms. Challenges and present potential breakthroughs that can be addressed via graphene bioelectronics are discussed. We emphasize the need for a multidisciplinary approach across materials science, micro-fabrication, and bioengineering to develop the next generation of I/O bioelectronics.


  • Three-Dimensional Graphene Microelectrode Arrays for Detection of Wound Healing Biomarkers

    by Daniel San Roman, Raghav Garg, Yingqiao Wang, Marissa Behun, Bryan Brown, Stephen Badylak, Tzahi Cohen-Karni

    Volumetric muscle loss (VML) injuries, such as those from high-energy trauma or tumor ablation, often result in scar tissue formation and permanent loss of skeletomuscular function. Directly after VML injury formation, neutrophils and macrophages arrive at the wound site, releasing cytokines and growth factors to allow proliferation and innervation. Monitoring the wound healing process by spatially mapping key regulatory wound biomarkers, such as nitric oxide (NO), can elucidate the state of the wound and thus inform critical clinical interventions. While single-point NO probes with sufficient performance for short-term measurements have been produced previously, improvements in device sensitivity, stability, and the number of sensing nodes are needed for in vivo applications. Here we leverage novel nanomaterials and their exceptional electrochemical properties to construct three-dimensional fuzzy graphene (3DFG) microelectrode arrays (MEAs) for the multiplexed electrochemical sensing of NO. We report in vitro results for 3DFG MEAs capable of selectively detecting NO (versus known interferents such as nitrite, ascorbic acid, and uric acid) at physiological concentrations in the nanomolar regime (limit of detection < 10 nM). Future work will entail in vivo NO detection to aid in monitoring wound states in animal models.

  • Multi-Dimensional Fuzzy Graphene Bioelectronic Actuators

    by Raghav Garg, Reem Rashid, Daniel San Roman, Yingqiao Wang, Maria Stang, Adam Feinberg, Jonathan Rivnay, Tzahi Cohen-Karni

    The ability to manipulate the electrophysiology of electrically active cells and tissues has enabled a deeper understanding of healthy and diseased states. This has primarily been achieved via bioelectronic actuators that interface engineered materials with biological entities. Graphene has gained recent interest as a building-block for bioelectronic actuators due to its advantageous electrochemical properties and biocompatibility. However, functional graphene bioelectronics exhibit a two-dimensional (2D) topology. This leads to inherent performance limitations due to the limited exposed surface-area and poor interactions with interfaced cells and tissues. Ideal geometry of graphene-based actuators needs to leverage the material’s high surface-area-to-volume ratio to facilitate maximum interaction with the electrode. Here we report a breakthrough three-dimensional (3D) topology of graphene: nanowire templated 3D fuzzy graphene (NT-3DFG), for actuation of electrically active cells and tissues. Using a bottom-up approach, we synthesize an interconnected network of free-standing graphene flakes on Si nanowires (SiNWs). The 3D topology leads to enhanced surface-area compared to planar surfaces allowing NT-3DFG microelectrodes to exhibit lower electrode impedance. The increased surface area also leads to an increase of up to 5-fold and 10-fold in the cathodic charge storage capacity (CSCC) and the charge injection capacity (CIC), respectively, for 20 µm NT-3DFG compared to 20 µm conventional Pt electrodes. To enhance the electrical actuation capabilities of NT-3DFG, we electrodeposit poly(3,4-ethylenedioxythiophene)-polystyrene sulfonate (PEDOT:PSS) on the 3D electrodes. This results in further enhancement in the exhibited CSCC and CIC thus enabling further miniaturization of graphene-based microelectrodes to ultra-microelectrodes for functional bioelectronics. Our results demonstrate the importance of extending the topology of nanomaterials to 3D to push the physical and functional limits of conventional bioelectronics.

  • Open Access

    Bioelectronics with graphene nanostructures

    by Daniel San Roman, Raghav Garg, Tzahi Cohen-Karni

    Bioelectronic devices enable fundamental physiological and electrophysiological research, healthcare monitoring, and advanced therapeutics. To meet the demanding device requirements imposed by biomedical applications, graphene-based electronics offer a promising alternative to conventional bioelectronic device materials in an all-carbon platform. Continued advancements in graphene nanostructure synthesis and micro-fabrication techniques allow novel device architectures with vastly tunable physiochemical properties. Here, we highlight recent advances in graphene nanostructure-based bioelectronics. We distinguish between various material geometries and discuss their effect on device performance. Furthermore, we emphasize the continued development of fundamental relationships between 3D device geometries and material properties to allow next-generation bioelectronics for biosensing, electrophysiological recordings, and stimulation.


  • Multidimensional graphene nanostructures – synthesis and applications

    by Raghav Garg, Daniel San Roman, Tzahi Cohen-Karni

    Conventional graphene electronics fail to leverage the exceptional surface-area-to-volume ratio of graphene due to the challenges imposed by arranging two-dimensional (2D) nanomaterials in three-dimensional (3D) spaces. Recently, a new topology of graphene, nanowire template 3D fuzzy graphene (NT-3DFG), has been developed to overcome this limitation. We provide an overview of the unique physical and chemical properties of NT-3DFG that are a direct consequence of the material structure and describe NT-3DFG’s promising applications in bioelectronics and energy-related research.


  • Open Access

    Remote nongenetic optical modulation of neuronal activity using fuzzy graphene

    by Sahil K. Rastogi, Raghav Garg, Matteo Giuseppe Scopelliti, Bernardo I. Pinto, Jane E. Hartung, Seokhyoung Kim, Corban G. E. Murphey, Nicholas Johnson, Daniel San Roman, Francisco Bezanilla, et al.

    The ability to modulate cellular electrophysiology is fundamental to the investigation of development, function, and disease. Currently, there is a need for remote, nongenetic, light-induced control of cellular activity in two-dimensional (2D) and three-dimensional (3D) platforms. Here, we report a breakthrough hybrid nanomaterial for remote, nongenetic, photothermal stimulation of 2D and 3D neural cellular systems. We combine one-dimensional (1D) nanowires (NWs) and 2D graphene flakes grown out-of-plane for highly controlled photothermal stimulation at subcellular precision without the need for genetic modification, with laser energies lower than a hundred nanojoules, one to two orders of magnitude lower than Au-, C-, and Si-based nanomaterials. Photothermal stimulation using NW-templated 3D fuzzy graphene (NT-3DFG) is flexible due to its broadband absorption and does not generate cellular stress. Therefore, it serves as a powerful toolset for studies of cell signaling within and between tissues and can enable therapeutic interventions.


  • Engineering Three-Dimensional (3D) Out-of-Plane Graphene Edge Sites for Highly Selective Two-Electron Oxygen Reduction Electrocatalysis

    by Daniel San Roman, Dilip Krishnamurthy, Raghav Garg, Hasnain Hafiz, Michael Lamparski, Noel T. Nuhfer, Vincent Meunier, Venkatasubramanian Viswanathan, Tzahi Cohen-Karni