Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Artur Tadeusz Krzyzak has a total of 117 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automated Brain Segmentation in Accelerated T2-Weighted MRI: Effects of Deep Learning-Based Reconstruction

    by Julia Lasek, Rafal Obuchowicz, Michal Strzelecki, Ireneusz Dwojak, Wojciech Kanas, Izabella Obuchowicz, Artur Krzyzak, Jaroslaw Minkowski

    Background: Automated brain volumetry is increasingly used for clinical and research assessment, but its outputs depend on acquisition and reconstruction settings. We evaluated how parallel-imaging acceleration and vendor deep-learning reconstruction (Siemens Deep Resolve) affect automated volumetry on T2-weighted turbo spin-echo MRI, and whether deep-learning reconstruction stabilises measurements across protocols. Methods: Four healthy volunteers each underwent 14 T2-TSE-TRA acquisitions on a 1.5 T scanner, covering seven protocols (baseline, GRAPPA R = 2, 3, 4, and SMS x2,x3, x4), with each protocol acquired separately once with Deep Resolve off and once with Deep Resolve on, for 56 acquisitions in total. Six pipelines were applied: SynthSeg, OpenMAP-T2, and GOUHFI 2.0 for subcortical parcellation, and TotalSegmentator MRI, HD-BET, and NV-Segment-CTMR for whole-brain masking. A three-rater STAPLE consensus of six subcortical structures on the baseline acquisition served as the expert reference. Reference-relative accuracy (absolute percentage error), cross-protocol dispersion (coefficient of variation), and spatial reproducibility (Dice coefficient and 95th-percentile surface distance) were compared between reconstruction states. Results: Deep Resolve improved reference-relative accuracy most for GOUHFI 2.0 (pooled median absolute percentage error 28.4% to 21.9%), modestly for SynthSeg (16.2% to 15.5%), and had a mixed, structure-dependent effect for OpenMAP-T2. It approximately halved cross-protocol dispersion for all three parcellation tools (coefficient of variation 2.62% to 1.39% for SynthSeg, 4.42% to 2.14% for OpenMAP-T2, and 21.75% to 7.87% for GOUHFI) and improved spatial reproducibility in parallel. It eliminated the systematic GOUHFI under-segmentation seen at high acceleration under conventional reconstruction (median deviation -31.6% at GRAPPA R = 4; 14 failure events under conventional reconstruction, none with Deep Resolve). Whole-brain masking was robust in both states. Conclusions: Deep Resolve improved the robustness of automated brain segmentation in accelerated T2-weighted MRI, reducing cross-protocol variability and improving spatial reproducibility, with the largest reduction in reference-relative error in the most acceleration-sensitive pipeline. The elimination of severe segmentation failures observed under conventional reconstruction highlights its potential to support reliable volumetry at higher acceleration. Reconstruction optimization therefore offers a practical route to more consistent quantitative measurements across acquisition protocols.

  • Open Access

    Tensor-derived diffusion MRI metrics and NODDI in multiple sclerosis classification

    by Julia Lasek, Weronika Mazur-Rosmus, Marcin Wnuk, Monika Marona, Klaudia Kaczówka, Agnieszka Słowik, Artur Krzyżak

  • Open Access

    T1- and diffusion tensor-based fractal dimension of white and grey matter in multiple sclerosis

    by Weronika Mazur-Rosmus, Zofia Schneider, Agnieszka Słowik, Artur Tadeusz Krzyżak

    Introduction: Multiple sclerosis (MS) changes brain microstructure even at early disease stages, with changes detectable in normal-appearing white matter (NAWM) and grey matter (GM). Diffusion tensor imaging (DTI) is sensitive to such alterations, while fractal dimension (FD) provides complementary information on tissue complexity. We hypothesized that T1-based FD offers additional diagnostic value beyond DTI-derived metrics of tissue integrity, including fractional anisotropy (FA) and mean diffusivity (MD). Methods: MRI data were acquired from 120 patients with relapsing–remitting MS and low mean Expanded Disability Status Scale (EDSS) scores, as well as 75 healthy control (HC) participants. FD, FA, and MD were quantified in global brain tissues and within white matter (WM) skeletons, both with and without lesion masking. The interactions between FD and DTI metrics were assessed, and classification models were constructed to evaluate diagnostic performance. Results: WM in MS exhibited reduced FD and FA alongside elevated MD, consistent with demyelination and axonal degradation. GM demonstrated higher FD, FA, and MD values, suggesting a more nuanced interplay of inflammatory remodeling, dendritic reorganization and compensatory structural adaptation. The limited impact of lesion masking on group-average metrics, but its marked effect on FD-DTI interactions, revealed that lesions regulate structural variance without dominating global tissue complexity. FD proved particularly sensitive at tissue interfaces, where geometry is disrupted, whereas WM skeleton analyses reflected preserved regularity of core tracts, even amid microstructural degeneration. Discussion: Our findings support the concept of a surface-in gradient of complexity loss in MS. Combining FD with FA and MD substantially improved classification accuracy, particularly in WM skeleton-based models, emphasizing the diagnostic potential of geometric-microstructural integration. Widespread associations of FA with clinical covariates and age further suggest that diffuse WM alterations underpin both cognitive and clinical decline.


  • Open Access

    Mesozoic formations in Norway as CO₂-enhanced geothermal systems reservoirs: A pathway to efficient energy production

    by Anna Sowiżdżał, Bjørn Syvert Frengstad, Lars Aaberg Stenvik, Grzegorz Machowski, Michał Fajt, Edyta Puskarczyk, Paulina Krakowska-Madejska, Artur Krzyżak

  • Open Access

    Diagnostic performance of a multi-shell DTI protocol and its subsets with B-matrix spatial distribution correction in differentiating early multiple sclerosis patients from healthy controls

    by Artur Tadeusz Krzyzak, Julia Lasek, Agnieszka Slowik

    Introduction: This study investigates whether a multi-shell diffusion tensor imaging (DTI) protocol and its subsets can reliably distinguish healthy controls (HC) from patients with multiple sclerosis (MS) presenting with low Expanded Disability Status Scale (EDSS) scores and mild MRI findings.Methods: To enhance accuracy, spatial systematic errors in diffusion measurements were corrected using the B-matrix Spatial Distribution method (BSD-DTI). We examined the discriminative potential of fractional anisotropy (FA) and mean diffusivity (MD) across three broad brain regions: whole brain (WB), white matter (WM), and gray matter (GM), using both the full protocol and its subsets. Additionally, we employed a more detailed classification strategy based on segmentation into 95 regions of interest (ROIs), analyzing FA, MD, axial diffusivity (AD), and radial diffusivity (RD) under a stringent statistical criterion.Results: While the protocol and each subset showed a comparable ability to differentiate between HC and MS groups, substantial variability in metric values across protocols highlights the limited utility of directly comparing DTI metrics between acquisition schemes.Discussion: The results emphasize the importance of accounting for spatial systematic errors when selecting optimal protocols for clinical and research applications.


  • Open Access

    The added value of diffusion tensor imaging with systematic bias correction for the assessment of liver morphology and physiology

    by Weronika Mazur‐Rosmus, William M. Spees, Artur T. Krzyżak

    Diffusion‐weighted images of the human liver are prone to artifacts from bulk motions, poor SNR, non‐uniformity of magnetic field gradients, and non‐optimal choice of diffusion weightings. These factors markedly affect diffusion tensor imaging (DTI) metrics such as mean diffusivity (MD) and fractional anisotropy (FA).This work presents a simple preprocessing pipeline for enhanced magnetic field gradient non‐uniformity calibration and analysis of the systematic bias removal attained in each correction step.Liver DTI scans were conducted in two isotropic phantoms and one healthy volunteer. Diffusion tensor was calculated for the original data and after denoising, B1 correction, rigid body registration, and magnetic field gradient non‐uniformity correction applying the B‐matrix spatial distribution (BSD) method and then, compared with the standard approach (sDTI). MD and FA were determined in three segments of the right lobe from DTI using four different combinations of b‐values from the set 0, 400, and 800 s/mm2.Results showed that the proposed preprocessing and BSD methods have a significant impact on MD and FA values in off‐ and iso‐centered isotropic phantoms. The applied corrections applied to the human liver resulted in a 11% change in MD and a − 64% change in FA. By manipulating the b‐values used in the diffusion tensor calculation, DTI metrics that reflect only morphology or additional information about liver tissue physiology can be obtained.Accurate quantification of the human liver by diffusion requires appropriate preprocessing and carefully chosen b‐value.Noise, B1 inhomogeneity, mis‐registration, and non‐uniform magnetic field gradients significantly change distributions of DTI metrics in isotropic phantoms and the human liver. Basic preprocessing and the B‐matrix spatial distribution (BSD) method perform differently for off‐center and isocenter locations. In the human liver, they removed systematic bias of FA and MD by up to −63% and 11%, respectively. Visible variability of FA and MD among b‐value sets indicates the possibility of DTI sensitization to different liver compartments.


  • Open Access

    The effect of elimination of gibbs ringing, noise and systematic errors on the DTI metrics and tractography in a rat brain

    by Weronika Mazur-Rosmus, Artur T. Krzyżak

    Diffusion tensor imaging (DTI) metrics and tractography can be biased due to low signal-to-noise ratio (SNR) and systematic errors resulting from image artifacts and imperfections in magnetic field gradients. The imperfections include non-uniformity and nonlinearity, effects caused by eddy currents, and the influence of background and imaging gradients. We investigated the impact of systematic errors on DTI metrics of an isotropic phantom and DTI metrics and tractography of a rat brain measured at high resolution. We tested denoising and Gibbs ringing removal methods combined with the B matrix spatial distribution (BSD) method for magnetic field gradient calibration. The results showed that the performance of the BSD method depends on whether Gibbs ringing is removed and the effectiveness of stochastic error removal. Region of interest (ROI)-based analysis of the DTI metrics showed that, depending on the size of the ROI and its location in space, correction methods can remove systematic bias to varying degrees. The preprocessing pipeline proposed and dedicated to this type of data together with the BSD method resulted in an even − 90% decrease in fractional anisotropy (FA) (globally and locally) in the isotropic phantom and − 45% in the rat brain. The largest global changes in the rat brain tractogram compared to the standard method without preprocessing (sDTI) were noticed after denoising. The direction of the first eigenvector obtained from DTI after denoising, Gibbs ringing removal and BSD differed by an average of 56 and 10 degrees in the ROI from sDTI and from sDTI after denoising and Gibbs ringing removal, respectively. The latter can be identified with the amount of improvement in tractography due to the elimination of systematic errors related to imperfect magnetic field gradients. Based on the results, the systematic bias for high resolution data mainly depended on SNR, but the influence of non-uniform gradients could also be seen. After denoising, the BSD method was able to further correct both the metrics and tractography of the diffusion tensor in the rat brain by taking into account the actual distribution of magnetic field gradients independent of the examined object and uniquely dependent on the scanner and sequence. This means that in vivo studies are also subject to this type of errors, which should be taken into account when processing such data.