David Martin-Sanchez
Research Subjects
David Martin-Sanchez has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Jaime García-Rupérez
Nanophotonics Technology Center, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain
11 shared publications - Salvador Ponce-Alcántara
Nanophotonics Technology Center, Universitat Politècnica de València, Camí de Vera s/n, 46022 Valencia, Spain
9 shared publications Edward Z. Zhang
3 shared publications- Luis Torrijos-Morán
Nanophotonics Technology Center, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain
3 shared publications Paul C. Beard
3 shared publicationsFrancisco Prats Quilez
Nanophotonics Technology Center, Universtitat Politècnica de València, Valencia, Spain
2 shared publications
Latest Publications
- Open Access
- 11 September 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (19) , 39875-39888
Sensitive broadband ultrasound sensor based on a low-loss high-Q fused-silica plano-concave microresonator
Optical ultrasound sensors can achieve high sensitivity, small element size, and broadband frequency response. Polymer plano-concave microresonators (PCMRs) are among the most sensitive ultrasound sensors, but achieving further increases in sensitivity is limited by the optical absorption of the polymer cavity material. To address this, the use of fused silica as the cavity material is investigated. We present findings supporting the assertion that the low compressibility of fused silica compared to polymeric materials can be overcome by exploiting its extremely low optical absorption to achieve high Q-factors approaching 106. We also show that the high Q-factors can introduce laser phase noise unless very narrow linewidth (<150 Hz) laser sources are employed. In this work, a fused silica PCMR ultrasound sensor is reported that has an NEP of 0.7 mPa/√Hz, a broadband frequency response with a −3 dB bandwidth of 2.5 MHz, and low directional sensitivity.
- 11 September 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (19) , 39875-39888
Open AccessSensitive broadband ultrasound sensor based on a low-loss high-Q fused-silica plano-concave microresonator
Optical ultrasound sensors can achieve high sensitivity, small element size, and broadband frequency response. Polymer plano-concave microresonators (PCMRs) are among the most sensitive ultrasound sensors, but achieving further increases in sensitivity is limited by the optical absorption of the polymer cavity material. To address this, the use of fused silica as the cavity material is investigated. We present findings supporting the assertion that the low compressibility of fused silica compared to polymeric materials can be overcome by exploiting its extremely low optical absorption to achieve high Q-factors approaching 106. We also show that the high Q-factors can introduce laser phase noise unless very narrow linewidth (<150 Hz) laser sources are employed. In this work, a fused silica PCMR ultrasound sensor is reported that has an NEP of 0.7 mPa/√Hz, a broadband frequency response with a −3 dB bandwidth of 2.5 MHz, and low directional sensitivity.
- Open Access
- 3 May 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (10) , 16523-16534
ABCD transfer matrix model of Gaussian beam propagation in plano-concave optical microresonators
Plano-concave optical microresonators (PCMRs) are optical microcavities formed of one planar and one concave mirror separated by a spacer. PCMRs illuminated by Gaussian laser beams are used as sensors and filters in fields including quantum electrodynamics, temperature sensing, and photoacoustic imaging. To predict characteristics such as the sensitivity of PCMRs, a model of Gaussian beam propagation through PCMRs based on the ABCD matrix method was developed. To validate the model, interferometer transfer functions (ITFs) calculated for a range of PCMRs and beams were compared to experimental measurements. A good agreement was observed, suggesting the model is valid. It could therefore constitute a useful tool for designing and evaluating PCMR systems in various fields. The computer code implementing the model has been made available online.
- 3 May 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (10) , 16523-16534
Open AccessABCD transfer matrix model of Gaussian beam propagation in plano-concave optical microresonators
Plano-concave optical microresonators (PCMRs) are optical microcavities formed of one planar and one concave mirror separated by a spacer. PCMRs illuminated by Gaussian laser beams are used as sensors and filters in fields including quantum electrodynamics, temperature sensing, and photoacoustic imaging. To predict characteristics such as the sensitivity of PCMRs, a model of Gaussian beam propagation through PCMRs based on the ABCD matrix method was developed. To validate the model, interferometer transfer functions (ITFs) calculated for a range of PCMRs and beams were compared to experimental measurements. A good agreement was observed, suggesting the model is valid. It could therefore constitute a useful tool for designing and evaluating PCMR systems in various fields. The computer code implementing the model has been made available online.
- 1 January 2022
- Published by Optica Publishing Group
- p. OS3D.3
Limits of high-Q optical resonator sensors for photoacoustic imaging
Deep-tissue applications (>1cm) for photoacoustic imaging require high-sensitivity ultrasound transducers. High-Q resonator sensors are being developed to overcome current limits. Here we analyse the potential, limits and challenges on their design, fabrication, and interrogation.
- 1 January 2022
- Published by Optica Publishing Group
- p. OS3D.3
Limits of high-Q optical resonator sensors for photoacoustic imaging
Deep-tissue applications (>1cm) for photoacoustic imaging require high-sensitivity ultrasound transducers. High-Q resonator sensors are being developed to overcome current limits. Here we analyse the potential, limits and challenges on their design, fabrication, and interrogation.
- 25 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (15) , 8497-8504
Simultaneous Refractive Index Sensing Using an Array of Suspended Porous Silicon Membranes
We propose a fast and cost-effective method for obtaining a miniaturized array-formatted sensor suitable for multiplexed detection. Our solution is based on the fabrication of multiple μm-sized suspended porous silicon (PSi) membranes working as independent transducers. Our process can potentially integrate an array of up to 1000 sensing spots per cm2. We also propose a simple and user-friendly optical platform to simultaneously interrogate each element of the array in real-time. The feasibility of this idea was proved performing several sensing experiments where we were able to detect refractive index (RI) variations with different transducers at the same time. An average experimental sensitivity of 685 nm/RIU (Refractive Index Unit) was achieved, with a theoretical limit of detection (LoD) of 2·10-4 RIU. The analyzed sensing spots displayed similar behavior both in time and in magnitude. We believe that the high capabilities of the sensor presented in this work, along with the sensing mechanism, can be very useful for multi-parametric analysis and multi-target detection of biological samples
- 25 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (15) , 8497-8504
Simultaneous Refractive Index Sensing Using an Array of Suspended Porous Silicon Membranes
We propose a fast and cost-effective method for obtaining a miniaturized array-formatted sensor suitable for multiplexed detection. Our solution is based on the fabrication of multiple μm-sized suspended porous silicon (PSi) membranes working as independent transducers. Our process can potentially integrate an array of up to 1000 sensing spots per cm2. We also propose a simple and user-friendly optical platform to simultaneously interrogate each element of the array in real-time. The feasibility of this idea was proved performing several sensing experiments where we were able to detect refractive index (RI) variations with different transducers at the same time. An average experimental sensitivity of 685 nm/RIU (Refractive Index Unit) was achieved, with a theoretical limit of detection (LoD) of 2·10-4 RIU. The analyzed sensing spots displayed similar behavior both in time and in magnitude. We believe that the high capabilities of the sensor presented in this work, along with the sensing mechanism, can be very useful for multi-parametric analysis and multi-target detection of biological samples
- Open Access
- 2 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (24) , 11850-11857
Dual Refractive Index and Viscosity Sensing Using Polymeric Nanofibers Optical Structures
Porous materials have demonstrated to be ideal candidates for the creation of optical sensors with very high sensitivities. This is due both to the possibility of infiltrating the target substances into them and to their notable surface-to-volume ratio that provides a larger biosensing area. Among porous structures, polymeric nanofibers (NFs) layers fabricated by electrospinning have emerged as a very promising alternative for the creation of low-cost and easy-to-produce high performance optical sensors, for example, based on Fabry-Perot (FP) interferometers. However, the sensing performance of these polymeric NFs sensors is limited by the low refractive index contrast between the NFs porous structure and the target medium when performing in-liquid sensing experiments, which determines a very low amplitude of the FP interference fringes appearing in the spectrum. This problem has been solved with the deposition of a thin metal layer (∼ 3 nm) over the NFs sensing layer. We have successfully used these metal-coated FP NFs sensors to perform several real-time and in-flow refractive index sensing experiments. From these sensing experiments, we have also determined that the sponge-like structure of the NFs layer suffers an expansion/compression process that is dependent of the viscosity of the analyzed sample, what thus gives the possibility to perform a simultaneous dual sensing of refractive index and viscosity of a fluid.
- 2 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (24) , 11850-11857
Open AccessDual Refractive Index and Viscosity Sensing Using Polymeric Nanofibers Optical Structures
Porous materials have demonstrated to be ideal candidates for the creation of optical sensors with very high sensitivities. This is due both to the possibility of infiltrating the target substances into them and to their notable surface-to-volume ratio that provides a larger biosensing area. Among porous structures, polymeric nanofibers (NFs) layers fabricated by electrospinning have emerged as a very promising alternative for the creation of low-cost and easy-to-produce high performance optical sensors, for example, based on Fabry-Perot (FP) interferometers. However, the sensing performance of these polymeric NFs sensors is limited by the low refractive index contrast between the NFs porous structure and the target medium when performing in-liquid sensing experiments, which determines a very low amplitude of the FP interference fringes appearing in the spectrum. This problem has been solved with the deposition of a thin metal layer (∼ 3 nm) over the NFs sensing layer. We have successfully used these metal-coated FP NFs sensors to perform several real-time and in-flow refractive index sensing experiments. From these sensing experiments, we have also determined that the sponge-like structure of the NFs layer suffers an expansion/compression process that is dependent of the viscosity of the analyzed sample, what thus gives the possibility to perform a simultaneous dual sensing of refractive index and viscosity of a fluid.
- Open Access
- 23 March 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (6) , B355-B359
Thermo-Optic Coefficient of Porous Silicon in the Infrared Region and Oxidation Process at Low Temperatures
In this work, a porous silicon nanostructure has been fabricated by electrochemical means and used as a thermal sensor. The thermo-optic effect in the near infrared region has been experimentally studied based on spectroscopy measurements. Values of the thermo-optic coefficient between 3.2 and 7.9·10−5 K−1 have been obtained, depending on the porosity, reaching a maximum thermal sensitivity of 91 ± 3 pm/°C during the experiments carried out with the fabricated samples. Additionally, the oxidation process of the sensor at temperatures below 500 K has been studied, showing that the growth of the silicon oxide was dependent on the characteristics of the porous layers. Based on the experimental results, a mathematical model was developed to estimate the evolution of the oxidation process as a function of porosity and thickness.
- 23 March 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (6) , B355-B359
Open AccessThermo-Optic Coefficient of Porous Silicon in the Infrared Region and Oxidation Process at Low Temperatures
In this work, a porous silicon nanostructure has been fabricated by electrochemical means and used as a thermal sensor. The thermo-optic effect in the near infrared region has been experimentally studied based on spectroscopy measurements. Values of the thermo-optic coefficient between 3.2 and 7.9·10−5 K−1 have been obtained, depending on the porosity, reaching a maximum thermal sensitivity of 91 ± 3 pm/°C during the experiments carried out with the fabricated samples. Additionally, the oxidation process of the sensor at temperatures below 500 K has been studied, showing that the growth of the silicon oxide was dependent on the characteristics of the porous layers. Based on the experimental results, a mathematical model was developed to estimate the evolution of the oxidation process as a function of porosity and thickness.
- Open Access
- 21 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (9) , 3276-3281
Sensitivity Comparison of a Self-Standing Porous Silicon Membrane Under Flow-Through and Flow-Over Conditions
An optical sensor based on a self-standing porous silicon (PS) membrane is presented. The sensor was created by electrochemically etching a heavily doped p-type silicon wafer with an organic electrolyte that contained dimethylformamide (DMF). After fabrication, a high current density close to electropolishing was applied in order to allow the detachment from the substrate using a lift-off method. The PS membrane was integrated in a microfluidic cell for sensing purposes and reflectance spectra were continuously obtained while the target substance was flowed. A comparison of the bulk sensitivity achieved when flowing through and over the pores is reported. During the experiments, a maximum sensitivity of 770 nm/RIU measured at 1700 nm was achieved. Experimental sensitivity values are in good agreement with the theoretical calculations performed when flowing through the PS membrane, meaning that the highest possible sensitivity of that sensor was achieved. In contrast, a drop in the sensitivity of around 25% was observed when flowing over the PS membrane.
- 21 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (9) , 3276-3281
Open AccessSensitivity Comparison of a Self-Standing Porous Silicon Membrane Under Flow-Through and Flow-Over Conditions
An optical sensor based on a self-standing porous silicon (PS) membrane is presented. The sensor was created by electrochemically etching a heavily doped p-type silicon wafer with an organic electrolyte that contained dimethylformamide (DMF). After fabrication, a high current density close to electropolishing was applied in order to allow the detachment from the substrate using a lift-off method. The PS membrane was integrated in a microfluidic cell for sensing purposes and reflectance spectra were continuously obtained while the target substance was flowed. A comparison of the bulk sensitivity achieved when flowing through and over the pores is reported. During the experiments, a maximum sensitivity of 770 nm/RIU measured at 1700 nm was achieved. Experimental sensitivity values are in good agreement with the theoretical calculations performed when flowing through the PS membrane, meaning that the highest possible sensitivity of that sensor was achieved. In contrast, a drop in the sensitivity of around 25% was observed when flowing over the PS membrane.
- Open Access
- 3 January 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (2) , B9-B12
Macropore Formation and Pore Morphology Characterization of Heavily Doped p-Type Porous Silicon
Tuning the pore diameter of porous silicon films is essential for some applications such as biosensing, where the pore size can be used for filtering analytes or to control the biofunctionalization of its walls. However, macropore (>50nm) formation on p-type silicon is not yet fully controlled due to its strong dependence on resistivity. Electrochemical etching of heavily doped p-type silicon usually forms micropores (<5nm), but it has been found that bigger sizes can be achieved by adding an organic solvent to the electrolyte. In this work, we compare the results obtained when adding dimethylformamide (DMF) and dimethylsulfoxide (DMSO) to the electrolyte as well as the effect of a post-treatment of the sample with potasium hydroxide (KOH) and sodium hydroxide (NaOH) for macropore formation in p-type silicon with resistivities between 0.001 and 10Ω·cm, achieving pore sizes from 5 to 100nm.
- 3 January 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (2) , B9-B12
Open AccessMacropore Formation and Pore Morphology Characterization of Heavily Doped p-Type Porous Silicon
Tuning the pore diameter of porous silicon films is essential for some applications such as biosensing, where the pore size can be used for filtering analytes or to control the biofunctionalization of its walls. However, macropore (>50nm) formation on p-type silicon is not yet fully controlled due to its strong dependence on resistivity. Electrochemical etching of heavily doped p-type silicon usually forms micropores (<5nm), but it has been found that bigger sizes can be achieved by adding an organic solvent to the electrolyte. In this work, we compare the results obtained when adding dimethylformamide (DMF) and dimethylsulfoxide (DMSO) to the electrolyte as well as the effect of a post-treatment of the sample with potasium hydroxide (KOH) and sodium hydroxide (NaOH) for macropore formation in p-type silicon with resistivities between 0.001 and 10Ω·cm, achieving pore sizes from 5 to 100nm.
- Open Access
- 14 November 2018
- Published by MDPI AG in Proceedings
- Vol. 4 (1) , 14
Pore Morphology of Heavily Doped P-Type Porous Silicon
Tuning the pore diameter of porous silicon (PS) is essential for some applications such as biosensing, where the pore size can filter the entrance of some analytes or increase its sensitivity. However, macropore (>50 nm) formation on p-type silicon is still poorly known due to the strong dependence on resistivity. Electrochemically etching heavily doped p-type silicon usually forms micropores (<5 nm), but it has been found that bigger sizes can be achieved by adding an organic solvent to the electrolyte. In this work, we present the results of using dimethylformamide (DMF), dimethylsulfoxide (DMSO), potassium hydroxide (KOH) and sodium hydroxide (NaOH) for macropore formation in p-type silicon with a resistivity between 0.001 and 0.02 Ω∙cm, achieving pore sizes from 5 to 100 nm.
- 14 November 2018
- Published by MDPI AG in Proceedings
- Vol. 4 (1) , 14
Open AccessPore Morphology of Heavily Doped P-Type Porous Silicon
Tuning the pore diameter of porous silicon (PS) is essential for some applications such as biosensing, where the pore size can filter the entrance of some analytes or increase its sensitivity. However, macropore (>50 nm) formation on p-type silicon is still poorly known due to the strong dependence on resistivity. Electrochemically etching heavily doped p-type silicon usually forms micropores (<5 nm), but it has been found that bigger sizes can be achieved by adding an organic solvent to the electrolyte. In this work, we present the results of using dimethylformamide (DMF), dimethylsulfoxide (DMSO), potassium hydroxide (KOH) and sodium hydroxide (NaOH) for macropore formation in p-type silicon with a resistivity between 0.001 and 0.02 Ω∙cm, achieving pore sizes from 5 to 100 nm.
- Open Access
- 14 November 2018
- Published by MDPI AG in Proceedings
- Vol. 4 (1) , 17
Flow-Through Self-Standing Porous Silicon Sensor
A self-standing porous silicon (PS) multilayer structure detached from the substrate by the lift-off method and integrated with a microfluidic cell is presented. Experiments of refractive index changes sensing flow through open-ended pores are reported. We continuously recorded the reflectance spectra of the PS membrane each 30 s and measured the shift as different substances flowed through the structure. The experimental sensitivity values are in good agreement with the theoretical simulations performed.
- 14 November 2018
- Published by MDPI AG in Proceedings
- Vol. 4 (1) , 17
Open AccessFlow-Through Self-Standing Porous Silicon Sensor
A self-standing porous silicon (PS) multilayer structure detached from the substrate by the lift-off method and integrated with a microfluidic cell is presented. Experiments of refractive index changes sensing flow through open-ended pores are reported. We continuously recorded the reflectance spectra of the PS membrane each 30 s and measured the shift as different substances flowed through the structure. The experimental sensitivity values are in good agreement with the theoretical simulations performed.