Daniel Kiv
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel Kiv has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- David John Lary
Department of Physics, The University of Texas at Dallas, Richardson, TX 75080, USA
7 shared publications - Adam Aker
Department of Physics, The University of Texas at Dallas, Richardson, TX 75080, USA
6 shared publications - Lakitha Omal Harindha Wijeratne
Department of Physics, University of Texas at Dallas, Richardson, TX 75080, USA
6 shared publications - Gokul Balagopal
Hanson Center for Space Sciences, University of Texas at Dallas, Richardson, TX 75080, USA
4 shared publications - John Waczak
Department of Physics, The University of Texas at Dallas, Richardson, TX 75080, USA
4 shared publications - Mazhar Iqbal
Hanson Center for Space Sciences, University of Texas at Dallas, Richardson, TX 75080, USA
4 shared publications
Latest Publications
- Open Access
The Design and Deployment of a Self-Powered, LoRaWAN-Based IoT Environment Sensor Ensemble for Integrated Air Quality Sensing and Simulation
The goal of this study is to describe a design architecture for a self-powered IoT (Internet of Things) sensor network that is currently being deployed at various locations throughout the Dallas-Fort Worth metroplex to measure and report on Particulate Matter (PM) concentrations. This system leverages diverse low-cost PM sensors, enhanced by machine learning for sensor calibration, with LoRaWAN connectivity for long-range data transmission. Sensors are GPS-enabled, allowing precise geospatial mapping of collected data, which can be integrated with urban air quality forecasting models and operational forecasting systems. To achieve energy self-sufficiency, the system uses a small-scale solar-powered solution, allowing it to operate independently from the grid, making it both cost-effective and suitable for remote locations. This novel approach leverages multiple operational modes based on power availability to optimize energy efficiency and prevent downtime. By dynamically adjusting system behavior according to power conditions, it ensures continuous operation while conserving energy during periods of reduced supply. This innovative strategy significantly enhances performance and resource management, improving system reliability and sustainability. This IoT network provides localized real-time air quality data, which has significant public health benefits, especially for vulnerable populations in densely populated urban environments. The project demonstrates the synergy between IoT sensor data, machine learning-enhanced calibration, and forecasting methods, contributing to scientific understanding of microenvironments, human exposure, and public health impacts of urban air quality. In addition, this study emphasizes open source design principles, promoting transparency, data quality, and reproducibility by exploring cost-effective sensor calibration techniques and adhering to open data standards. The next iteration of the sensors will include edge processing for short-term air quality forecasts. This work underscores the transformative role of low-cost sensor networks in urban air quality monitoring, advancing equitable policy development and empowering communities to address pollution challenges.
Open AccessThe Design and Deployment of a Self-Powered, LoRaWAN-Based IoT Environment Sensor Ensemble for Integrated Air Quality Sensing and Simulation
The goal of this study is to describe a design architecture for a self-powered IoT (Internet of Things) sensor network that is currently being deployed at various locations throughout the Dallas-Fort Worth metroplex to measure and report on Particulate Matter (PM) concentrations. This system leverages diverse low-cost PM sensors, enhanced by machine learning for sensor calibration, with LoRaWAN connectivity for long-range data transmission. Sensors are GPS-enabled, allowing precise geospatial mapping of collected data, which can be integrated with urban air quality forecasting models and operational forecasting systems. To achieve energy self-sufficiency, the system uses a small-scale solar-powered solution, allowing it to operate independently from the grid, making it both cost-effective and suitable for remote locations. This novel approach leverages multiple operational modes based on power availability to optimize energy efficiency and prevent downtime. By dynamically adjusting system behavior according to power conditions, it ensures continuous operation while conserving energy during periods of reduced supply. This innovative strategy significantly enhances performance and resource management, improving system reliability and sustainability. This IoT network provides localized real-time air quality data, which has significant public health benefits, especially for vulnerable populations in densely populated urban environments. The project demonstrates the synergy between IoT sensor data, machine learning-enhanced calibration, and forecasting methods, contributing to scientific understanding of microenvironments, human exposure, and public health impacts of urban air quality. In addition, this study emphasizes open source design principles, promoting transparency, data quality, and reproducibility by exploring cost-effective sensor calibration techniques and adhering to open data standards. The next iteration of the sensors will include edge processing for short-term air quality forecasts. This work underscores the transformative role of low-cost sensor networks in urban air quality monitoring, advancing equitable policy development and empowering communities to address pollution challenges.
- Open Access
Calibration of Low-Cost LoRaWAN-Based IoT Air Quality Monitors Using the Super Learner Ensemble: A Case Study for Accurate Particulate Matter Measurement
This study calibrates an affordable, solar-powered LoRaWAN air quality monitoring prototype using the research-grade Palas Fidas Frog sensor. Motivated by the need for sustainable air quality monitoring in smart city initiatives, this work integrates low-cost, self-sustaining sensors with research-grade instruments, creating a cost-effective hybrid network that enhances both spatial coverage and measurement accuracy. To improve calibration precision, the study leverages the Super Learner machine learning technique, which optimally combines multiple models to achieve robust PM (Particulate Matter) monitoring in low-resource settings. Data was collected by co-locating the Palas sensor and LoRaWAN devices under various climatic conditions to ensure reliability. The LoRaWAN monitor measures PM concentrations alongside meteorological parameters such as temperature, pressure, and humidity. The collected data were calibrated against precise PM concentrations and particle count densities from the Palas sensor. Various regression models were evaluated, with the stacking-based Super Learner model outperforming traditional approaches, achieving an average test R2 value of 0.96 across all target variables, including 0.99 for PM2.5 and 0.91 for PM10.0. This study presents a novel approach by integrating Super Learner-based calibration with LoRaWAN technology, offering a scalable solution for low-cost, high-accuracy air quality monitoring. The findings demonstrate the feasibility of deploying these sensors in urban areas such as the Dallas-Fort Worth metroplex, providing a valuable tool for researchers and policymakers to address air pollution challenges effectively.
Open AccessCalibration of Low-Cost LoRaWAN-Based IoT Air Quality Monitors Using the Super Learner Ensemble: A Case Study for Accurate Particulate Matter Measurement
This study calibrates an affordable, solar-powered LoRaWAN air quality monitoring prototype using the research-grade Palas Fidas Frog sensor. Motivated by the need for sustainable air quality monitoring in smart city initiatives, this work integrates low-cost, self-sustaining sensors with research-grade instruments, creating a cost-effective hybrid network that enhances both spatial coverage and measurement accuracy. To improve calibration precision, the study leverages the Super Learner machine learning technique, which optimally combines multiple models to achieve robust PM (Particulate Matter) monitoring in low-resource settings. Data was collected by co-locating the Palas sensor and LoRaWAN devices under various climatic conditions to ensure reliability. The LoRaWAN monitor measures PM concentrations alongside meteorological parameters such as temperature, pressure, and humidity. The collected data were calibrated against precise PM concentrations and particle count densities from the Palas sensor. Various regression models were evaluated, with the stacking-based Super Learner model outperforming traditional approaches, achieving an average test R2 value of 0.96 across all target variables, including 0.99 for PM2.5 and 0.91 for PM10.0. This study presents a novel approach by integrating Super Learner-based calibration with LoRaWAN technology, offering a scalable solution for low-cost, high-accuracy air quality monitoring. The findings demonstrate the feasibility of deploying these sensors in urban areas such as the Dallas-Fort Worth metroplex, providing a valuable tool for researchers and policymakers to address air pollution challenges effectively.
- Open Access
- 4 February 2025
- Published by MDPI AG in Preprints.org
Calibration of Low-Cost LoRaWAN-Based IoT Air Quality Monitors Using the Super Learner Ensemble: A Case Study for Accurate PM Measurement
This study calibrates an affordable, solar-powered LoRaWAN air quality monitoring prototype using the research-grade Palas Fidas Frog sensor. By leveraging the Super Learner machine learning technique, it develops cost-effective sensors for accurate PM (Particulate Matter) monitoring in low-resource settings. Data was collected by co-locating the Palas sensor and LoRaWAN devices under various climatic conditions over multiple days to ensure reliable calibration. The LoRaWAN air quality monitor integrates sensors that measure PM concentrations and meteorological parameters, including temperature, pressure, and humidity. The collected data were calibrated using precise PM concentrations and particle count density measured by the Palas sensor. Various regression models were evaluated, with the stacking model (Super Learner) demonstrating superior performance. By combining simple and complex models, the stacking model achieved the most accurate predictions, with an average test R2 value of 0.96 across all target variables. Specifically, it achieved R2 values of 0.99 for PM2.5 and 0.91 for PM10.0, demonstrating near-research-grade accuracy and underscoring the robustness of the calibration. This study offers a practical and scalable solution for cost-effective air quality monitoring, with significant potential for deployment in the Dallas-Fort Worth metroplex and similar urban areas.
- 4 February 2025
- Published by MDPI AG in Preprints.org
Open AccessCalibration of Low-Cost LoRaWAN-Based IoT Air Quality Monitors Using the Super Learner Ensemble: A Case Study for Accurate PM Measurement
This study calibrates an affordable, solar-powered LoRaWAN air quality monitoring prototype using the research-grade Palas Fidas Frog sensor. By leveraging the Super Learner machine learning technique, it develops cost-effective sensors for accurate PM (Particulate Matter) monitoring in low-resource settings. Data was collected by co-locating the Palas sensor and LoRaWAN devices under various climatic conditions over multiple days to ensure reliable calibration. The LoRaWAN air quality monitor integrates sensors that measure PM concentrations and meteorological parameters, including temperature, pressure, and humidity. The collected data were calibrated using precise PM concentrations and particle count density measured by the Palas sensor. Various regression models were evaluated, with the stacking model (Super Learner) demonstrating superior performance. By combining simple and complex models, the stacking model achieved the most accurate predictions, with an average test R2 value of 0.96 across all target variables. Specifically, it achieved R2 values of 0.99 for PM2.5 and 0.91 for PM10.0, demonstrating near-research-grade accuracy and underscoring the robustness of the calibration. This study offers a practical and scalable solution for cost-effective air quality monitoring, with significant potential for deployment in the Dallas-Fort Worth metroplex and similar urban areas.
- Open Access
- 15 November 2024
- Published by MDPI AG in Preprints.org
The Design and Deployment of a Self-Powered, LoRaWAN-Based IoT Environment Sensor Ensemble for Integrated Air Quality Sensing and Simulation
The goal of this study is to describe a design architecture for a self-powered IoT (Internet of Things) sensor network that is currently being deployed at various locations throughout the Dallas-Fort Worth metroplex to measure and report on Particulate Matter (PM) concentrations. This system leverages diverse low-cost PM sensors, enhanced by machine learning for sensor calibration, with LoRaWAN connectivity for long-range data transmission. Sensors are GPS-enabled, allowing precise geospatial mapping of collected data, which can be integrated with urban air quality forecasting models and operational forecasting systems. To achieve energy self-sufficiency, the system uses a small-scale solar-powered solution, allowing it to operate independently from the grid, making it both cost-effective and suitable for remote locations. This novel approach leverages multiple operational modes based on power availability to optimize energy efficiency and prevent downtime. By dynamically adjusting system behavior according to power conditions, it ensures continuous operation while conserving energy during periods of reduced supply. This innovative strategy significantly enhances performance and resource management, improving system reliability and sustainability. This IoT network provides localized real-time air quality data, which has significant public health benefits, especially for vulnerable populations in densely populated urban environments. The project demonstrates the synergy between IoT sensor data, machine learning-enhanced calibration, and forecasting methods, contributing to scientific understanding of microenvironments, human exposure, and public health impacts of urban air quality. In addition, this study emphasizes open source design principles, promoting transparency, data quality, and reproducibility by exploring cost-effective sensor calibration techniques and adhering to open data standards. The next iteration of the sensors will include edge processing for short-term air quality forecasts.
- 15 November 2024
- Published by MDPI AG in Preprints.org
Open AccessThe Design and Deployment of a Self-Powered, LoRaWAN-Based IoT Environment Sensor Ensemble for Integrated Air Quality Sensing and Simulation
The goal of this study is to describe a design architecture for a self-powered IoT (Internet of Things) sensor network that is currently being deployed at various locations throughout the Dallas-Fort Worth metroplex to measure and report on Particulate Matter (PM) concentrations. This system leverages diverse low-cost PM sensors, enhanced by machine learning for sensor calibration, with LoRaWAN connectivity for long-range data transmission. Sensors are GPS-enabled, allowing precise geospatial mapping of collected data, which can be integrated with urban air quality forecasting models and operational forecasting systems. To achieve energy self-sufficiency, the system uses a small-scale solar-powered solution, allowing it to operate independently from the grid, making it both cost-effective and suitable for remote locations. This novel approach leverages multiple operational modes based on power availability to optimize energy efficiency and prevent downtime. By dynamically adjusting system behavior according to power conditions, it ensures continuous operation while conserving energy during periods of reduced supply. This innovative strategy significantly enhances performance and resource management, improving system reliability and sustainability. This IoT network provides localized real-time air quality data, which has significant public health benefits, especially for vulnerable populations in densely populated urban environments. The project demonstrates the synergy between IoT sensor data, machine learning-enhanced calibration, and forecasting methods, contributing to scientific understanding of microenvironments, human exposure, and public health impacts of urban air quality. In addition, this study emphasizes open source design principles, promoting transparency, data quality, and reproducibility by exploring cost-effective sensor calibration techniques and adhering to open data standards. The next iteration of the sensors will include edge processing for short-term air quality forecasts.
- 4 May 2021
- Published by Springer Nature
- p. 243-263
Advancement in Airborne Particulate Estimation Using Machine Learning
- 4 May 2021
- Published by Springer Nature
- p. 243-263
Advancement in Airborne Particulate Estimation Using Machine Learning
- 4 May 2021
- Published by Springer Nature
- p. 219-241
Machine Learning, Big Data, and Spatial Tools: A Combination to Reveal Complex Facts That Impact Environmental Health
- 4 May 2021
- Published by Springer Nature
- p. 219-241
Machine Learning, Big Data, and Spatial Tools: A Combination to Reveal Complex Facts That Impact Environmental Health
- Open Access
- 9 January 2021
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 8 (1)
Study of Antarctic Blowing Snow Storms Using MODIS and CALIOP Observations With a Machine Learning Model
As a common phenomenon over Antarctica, blowing snow (BLSN), especially the large BLSN storms, play an important role in the Antarctic surface mass balance, radiation budget, and planetary boundary layer processes. This study presents the work on BLSN storm identification and analysis with observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Aqua satellite. Spectral analysis shows that BLSN identification is feasible with MODIS daytime data. A random forest machine learning model is developed and observations from the Cloud‐Aerosol Lidar with Orthogonal Polarization are used for training. Model performance results show that machine‐learning based classification can achieve over 90% overall accuracy when classifying MODIS pixels into cloud, clear, and BLSN categories. The machine learning model is applied to MODIS observations during the month of October 2009 for BLSN storm analysis. Results show that the size of BLSN storms has a large spectrum and can reach hundreds of thousands km2. The MODIS based BLSN storm frequency map extends the Cloud‐Aerosol Lidar and Infrared Pathfinder Satellite Observations coverage limit from 82°S to the South Pole. A BLSN storm belt, which extends from the South Pole region to the coastal area between 130°E and 160°E along the Transantarctic Mountains, provides a potential pathway of snow transport. These results are important in improving the understanding of BLSN impact on Antarctic surface mass balance and boundary layer processes.
- 9 January 2021
- Published by American Geophysical Union (AGU) in Earth and Space Science
- Vol. 8 (1)
Open AccessStudy of Antarctic Blowing Snow Storms Using MODIS and CALIOP Observations With a Machine Learning Model
As a common phenomenon over Antarctica, blowing snow (BLSN), especially the large BLSN storms, play an important role in the Antarctic surface mass balance, radiation budget, and planetary boundary layer processes. This study presents the work on BLSN storm identification and analysis with observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Aqua satellite. Spectral analysis shows that BLSN identification is feasible with MODIS daytime data. A random forest machine learning model is developed and observations from the Cloud‐Aerosol Lidar with Orthogonal Polarization are used for training. Model performance results show that machine‐learning based classification can achieve over 90% overall accuracy when classifying MODIS pixels into cloud, clear, and BLSN categories. The machine learning model is applied to MODIS observations during the month of October 2009 for BLSN storm analysis. Results show that the size of BLSN storms has a large spectrum and can reach hundreds of thousands km2. The MODIS based BLSN storm frequency map extends the Cloud‐Aerosol Lidar and Infrared Pathfinder Satellite Observations coverage limit from 82°S to the South Pole. A BLSN storm belt, which extends from the South Pole region to the coastal area between 130°E and 160°E along the Transantarctic Mountains, provides a potential pathway of snow transport. These results are important in improving the understanding of BLSN impact on Antarctic surface mass balance and boundary layer processes.
- Open Access
Using Machine Learning for the Calibration of Airborne Particulate Sensors
Airborne particulates are of particular significance for their human health impacts and their roles in both atmospheric radiative transfer and atmospheric chemistry. Observations of airborne particulates are typically made by environmental agencies using rather expensive instruments. Due to the expense of the instruments usually used by environment agencies, the number of sensors that can be deployed is limited. In this study we show that machine learning can be used to effectively calibrate lower cost optical particle counters. For this calibration it is critical that measurements of the atmospheric pressure, humidity, and temperature are also made.
Open AccessUsing Machine Learning for the Calibration of Airborne Particulate Sensors
Airborne particulates are of particular significance for their human health impacts and their roles in both atmospheric radiative transfer and atmospheric chemistry. Observations of airborne particulates are typically made by environmental agencies using rather expensive instruments. Due to the expense of the instruments usually used by environment agencies, the number of sensors that can be deployed is limited. In this study we show that machine learning can be used to effectively calibrate lower cost optical particle counters. For this calibration it is critical that measurements of the atmospheric pressure, humidity, and temperature are also made.