Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Franziska Schmidt has a total of 253 co-authors. Here are the top co-authors by number of shared publications:

  • Florian Beuer

    Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany

    14 shared publications
  • Florian Beuer

    Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders Charité‐Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt‐Universität Zu Berlin Berlin Germany

    13 shared publications
  • Aleksander Gurlo

    Technische Universität Berlin, Chair of Advanced Ceramic Materials, Straße des 17. Juni 135, 10623 Berlin, Germany

    10 shared publications
  • Alexey Unkovskiy

    Department of Oral Surgery, E.V. Borovsky Institute of Dentistry, Sechenov First Moscow State Medical University, Moscow, 119048, Russia.

    10 shared publications
  • Andreas Dominik Schwitalla

    Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Dental Materials and Biomaterial Research, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Str. 4-6, 14197, Berlin, Germany; Einstein Center Digital Future (ECDF), Robert-Koch-Forum, Wilhelmstr. 67, 10117 Berlin, Germany

    9 shared publications
  • Elisabeth Prause

    Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität Zu Berlin, Berlin, Germany

    7 shared publications

Latest Publications

  • Open Access

    Biaxial Flexural Strength and Fracture Behavior of Five-Unit Monolithic Zirconia Fixed Dental Prostheses: An Experimental and Finite Element Study

    by Theresa Schwab, Jamila Yassine, Robert Nicic, Felix Borges, Alexander Pugachev, Franziska Schmidt

    Higher-translucency zirconia grades (4Y- and 5Y-PSZ) offer esthetic advantages over conventional 3Y-TZP but exhibit reduced flexural strength, raising concerns for restorations with reduced connector dimensions. It is unclear whether biaxial flexural strength, as determined by standardized specimen testing, translates to the fracture resistance of geometrically complex multi-unit bridges. This study compared the biaxial flexural strength (DIN EN ISO 6872:2015, n = 45) of three zirconia grades (3Y-TZP, 4Y-PSZ, and 5Y-PSZ) with the fracture behavior of monolithic five-unit fixed dental prostheses (FDPs) with deliberately undersized connectors (n = 24, teeth 33–37) made from the same three zirconia grades. Finite element (FE) analysis was used to compare the simulated elastic stress distribution with the experimentally observed fracture location. Biaxial flexural strength differed significantly among all groups (3Y-TZP: 1406.5 ± 133.3 MPa, 4Y-PSZ: 1146.9 ± 215.9 MPa, and 5Y-PSZ: 657.0 ± 137.5 MPa; p < 0.001). In contrast, bridge fracture loads differed less between the zirconia grades (3Y-TZP: 542.1 ± 44.9 N, 4Y-PSZ: 466.6 ± 116.6 N, and 5Y-PSZ: 372.1 ± 32.1 N). Only 5Y-PSZ showed significantly lower fracture loads than 3Y-TZP (p < 0.001), whereas 4Y-PSZ did not differ significantly from either 3Y-TZP (p = 0.253) or 5Y-PSZ (p = 0.129). All bridges initially fractured at the undersized connector, matching the site of the highest predicted tensile stress in den FE analysis. With this deliberately undersized connector, the differences in biaxial flexural strength between 3Y-TZP and 4Y-PSZ did not translate proportionally in a significant difference in fracture load. The FE analysis correctly identified the fracture-critical connector. The fracture load was not predicted, since the simulations were calibrated to the experimental fracture load values.

  • Open Access

    Printing Parameters and Surface Treatments on Color and Translucency Stability

    by S. Weng, Z. Mao, I. Topolniak, A.A. Diken Türksayar, J. Yassine, F. Beuer, F. Schmidt

    Additive manufacturing (AM) has expanded in dentistry, yet the color and translucency stability of 3-dimensional-printed resin-based materials remain insufficiently understood. This study investigated the main and interaction effects of printing orientation, specimen thickness, and surface treatments on the color and translucency stability of a 3-dimensional printed resin–ceramic hybrid material. Ninety AM specimens were fabricated using a factorial design combining 3 printing orientations, 3 specimen thicknesses, and 2 surface treatments (3 × 3 × 2, n = 5 per condition) and compared with 30 subtractively manufactured control specimens (Vita Enamic). Aging was simulated by thermocycling (5000 cycles, 5–55 °C). Color coordinates were measured via the Commission Internationale de l’Éclairage L*a*b* color system, and color change and translucency change were calculated. Degree of conversion, water sorption, and surface roughness were also evaluated. Printing orientation and specimen thickness significantly affected color change and translucency change ( P < 0.05), with the 90° orientation showing lower changes than 0° and 45°. Surface treatment had a limited influence on color and translucency stability, although glazing resulted in higher water sorption as compared with polishing ( P < 0.05). No significant effects of printing orientation were observed for degree of conversion or surface roughness, whereas surface treatment significantly influenced surface roughness ( P < 0.05). Despite these variations, all groups remained within clinically acceptable thresholds for color and translucency changes. Overall, the findings suggest that AM resin–ceramic restorations have potential for use in definitive restorations. Optimizing printing orientation and material thickness may enhance the color and translucency stability of AM resin–ceramic restorations, supporting their clinical applicability.

  • Simulation of functional ageing towards failure prediction of dental restorations - Investigating the crown-cement-tooth complex using synchrotron x-ray refraction radiography

    by Akshar Soni, Charité-Universitätsmedizin Berlin, Jonas Rechlin, Technische Universität Berlin, Tobias Horbrügger, Itziar Serrano-Munoz, Franziska Schmidt, Manja Von Stein-Lausnitz, Paul Zaslansky, Florian Beuer, et al.

    In the SimuCrown project, ageing mechanisms within the crown-cement-tooth complex (CCTC) are investigated, with a focus on high-resolution structural characterisation. Although dental crowns are widely used indirect restorations worldwide, links between clinical complications such as debonding, fractures and time-dependent cement degradation remain insufficiently understood. To address this, we employ high-resolution X-ray µCT and synchrotron X-ray refraction radiography (SXRR) to identify microstructural ageing processes which are inaccessible with conventional imaging. CCTCs subjected to controlled chewing simulation are examined using SXRR to detect structural alterations, interfacial defects, and the progression of damage within the cement layer and neighbouring materials. Our research explores crack initiation, pore evolution, and interfacial integrity using SXRR, capturing degradation phenomena across multiple time scales. By integrating synchrotron imaging with functional ageing simulation and computational modelling, the SimuCrown project offers a robust framework for evaluating the long-term performance of dental restorations. The outcomes contribute to the optimisation of materials and cementation approaches aimed at improving the clinical durability of dental restorations.

  • Open Access

    Repair Bond Strength of Milled and 3D‐Printed CAD/CAM Hybrid Materials Using Different Repair Protocols: An In Vitro Study

    by Marko Milicevic, Florian Beuer, Nico Henning, Jamila Yassine, Franziska Schmidt, Jonas Rechlin, Elisabeth Prause

    Objectives: The aim of this study was to evaluate the bond strength of different computer‐aided design/computer‐aided manufacturing (CAD/CAM) hybrid materials for milling and 3D‐printing with and without thermocycling. Different repair protocols were tested. Materials and Methods: Two milled and one experimental 3D‐printed hybrid material were tested with three repair systems (MO [universal primer and dental adhesive]; GC [Repair Kit]; Voco Cimara [Repair Kit]). A total of 180 specimens were prepared ( n = 60 per material). Half underwent thermocycling (30,000 cycles, 5°C–55°C), while the others were stored in distilled water (37°C). Shear bond strength was determined using a universal testing machine. Fracture modes were analyzed microscopically, and selected samples were examined via scanning electron microscopy. Data were analyzed by three‐way ANOVA followed by Tukey's and Bonferroni post hoc tests ( p < 0.05). Results: The results of the present study showed that the choice of repair protocol and the tested material significantly influenced the shear bond strength. MO achieved the highest shear bond strength values among all tested materials before and after thermocycling. After thermocycling, only GC in combination with the experimental 3D‐printed material depicted an increase in shear bond strength (12.55 → 14.51 MPa). Regarding the tested milled materials, thermocycling reduced shear bond strength across all protocols. Conclusions: Shear bond strength was significantly influenced by the type of CAD/CAM material and repair protocol used. Thermocycling reduced shear bond strength in milled materials, while the 3D‐printed material showed improved values with specific protocols. Clinicians should be aware that both the choice of CAD/CAM material and the repair protocol significantly affect bond strength.


  • Open Access

    The immune cell atlas of biodegradable magnesium implants

    by Qinyang Yan, Yifan Wu, Wenyan Zhan, Alexey Unkovskiy, Franziska Schmidt, Jiahao Chen, Jiannan Zhou, Zhentao Yu, Frank Witte, Jingtao Dai, et al.

    Magnesium (Mg)-based biodegradable metals have been introduced into clinical applications. Their degradation products, particularly peri-implant gas accumulation and ion release, create a complex microenvironment conducive to regenerative immune reprogramming. However, the local immune landscape shaped by Mg-based implants remains poorly understood. Here, single-cell RNA sequencing was used to establish an immune cell atlas of the early osteoimmune response to Mg implants compared with titanium (Ti) implants. In contrast to the pro-inflammatory profile dominated by Chi3l1+ macrophages in the Ti group, the Mg group exhibited a shift toward Apoe+ and Cd74+ reparative macrophages, and inflammation resolution. Notably, the Nrxn3+ neutrophil subset was identified, which is enriched in the peri-implant microenvironment of the Mg group relative to the Ti group. Characterized by the expression of neural-interaction markers, this subset links mechanical cues from peri-implant gas accumulation to downstream cellular signaling. Furthermore, Mg implants fostered a peri-implant microenvironment with tolerogenic adaptive immunity, characterized by Lag3+ exhausted T cells and CD4+ naive T cells. These findings of the immune cell atlas demonstrate that Mg implants regeneratively reprogram the immune system.

  • Open Access

    Mechanical and biological properties of two new commercial PEEK framework materials for fixed and removable dental prostheses compared to unfilled PEEK: An in vitro study

    by Jamila Yassine, Barwin Mahmoud, Franziska Schmidt, Florian Beuer, Rafik Akhmad, Zhen Mao, Wolf-Dieter Müller, Andreas Dominik Schwitalla

  • Open Access

    Accuracy and Fit of Three-Unit Dental Restorations Fabricated from 3D-Printed Resins and CAD/CAM Milling Materials: A Micro-CT Study

    by Jamila Yassine, Almira Ada Diken Türksayar, Florian Beuer, Nursena Öztemel, Franziska Schmidt

    (1) Purpose: To compare the fabrication accuracy, internal fit, and marginal adaptation of three-unit definitive resin fixed dental prostheses (FDPs) produced by subtractive milling and additive manufacturing. (2) Materials and Methods: A typodont mandible was prepared for a three-unit FDP, with full crown preparations on teeth mandibular left canine and mandibular left second premolar featuring 1 mm chamfer finish lines. The FDP was designed with a 16 mm2 connector and a 100 µm cement gap. Two milling materials (Ambarino High-Class, IPS e.max CAD) and two experimental 3D printing hybrid resins (3D-1, 3D-2) were used. All restorations were scanned using an intraoral scanner and compared to the original STL using reverse engineering software for surface trueness and deviation analysis. The internal fit was evaluated using the triple-scan method, while marginal fit was assessed via micro-CT imaging. Statistical analysis was conducted using one-way ANOVA and Kruskal–Wallis tests (α = 0.05). (3) Results: Milled groups demonstrated a lower prevalence of external, marginal, and overall surface deviations (p < 0.001), while 3D-1 exhibited comparable deviations within the internal region with M-E (p = 0.067). Milled groups had average gap values that were similar to 3D-1 (p > 0.08), but significantly lower than 3D-2 (p < 0.002). In marginal adaptation evaluated by micro-CT, the M-A and M-E groups provided significantly lower gaps, while the 3D-1 and 3D-2 groups exhibited wider marginal and axial gaps. (4) Conclusions: These results indicate that while milling remains a more reliable manufacturing method for achieving external and marginal precision, position 3D-1 is a compelling, chairside alternative to milling.


  • Open Access

    Human oral microbiome interactions with magnesium implants

    by Lian Huang, Wentai Zhang, Jiahao Chen, Franziska Schmidt, Yanyun Liu, Kai Chen, Janak Lal Pathak, Zhentao Yu, Ping Li


  • Open Access

    The effect of nitrogen atmosphere during post-curing on cytotoxicity, polishability, flexural strength, and surface hardness of 3D-printed denture bases: an in vitro study

    by Karoline Gladrow, Alexey Unkovskiy, Jamila Yassine, Nora Gaertner, Ievgeniia Topolniak, Nico Henning, Franziska Schmidt

    3D printing is increasingly utilized in dentistry. Compared to traditional manufacturing methods, 3D printing provides advantages such as faster production times and the ability to create complex structures. Although biocompatible materials are available, many are only suitable for temporary applications. This study examines the impact of nitrogen-aided post-processing on the mechanical properties and cytotoxicity of 3D-printed denture bases, with the hypothesis that this post-processing will enhance material properties and decrease cytotoxicity. Specimens were fabricated from V-print dentbase (Voco GmbH, Cuxhaven, Germany) and post-processed either in nitrogen or air. The specimens were categorized into aged and non-aged groups. For comparison, specimens made from milled material were utilized. Vickers hardness, flexural strength, polishability, cytotoxicity, and degree of conversion were then assessed for all groups. The data were analyzed using a one-way ANOVA and Tukey HSD test for multiple comparisons, with a significance threshold of p < 0.05. Post-curing with nitrogen improved the degree of conversion, surface hardness, and biocompatibility of 3D-printed dental materials, confirming reduced cytotoxicity without impairing mechanical properties. Nitrogen increased polymerization and decreased harmful monomers, making it ideal for clinical applications in contact with the oral mucosa. Optimizing post-processing steps, such as curing in nitrogen, enhances biocompatibility while maintaining strength and hardness, ensuring better patient care in dental applications.


  • Data-driven modeling for build angle optimization to improve accuracy of 3D-printed resin crowns

    by Kaibin Wu, Chen Zhu, Qinyang Yan, Alexey Unkovskiy, Franziska Schmidt, Zhe Wu, Bingjiang Qiu, Ping Li