Maju Kuriakose
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maju Kuriakose has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Srivalleesha Mallidi
Department of Biomedical Engineering, Tufts University, Medford, USA
4 shared publications - Samuel Raetz
Laboratoire d'Acoustique de l'Université du Mans (LAUM), UMR 6613, Institut d'Acoustique - Graduate School (IA-GS), CNRS, Le Mans Université, France
3 shared publications - Vitalyi E. Gusev
Laboratoire d'Acoustique de l’Université du Mans (LAUM)
3 shared publications Alain Bulou
IMMM, UMR-CNRS 6283, Université du Maine, Avenue O. Messiaen, F-72085 Le Mans, France
2 shared publications- Andreas Zerr
Laboratoire des Sciences des Procédés et des Matériaux, CNRS UPR 3407, Université Sorbonne Paris Nord 3 , 93430 Villetaneuse
2 shared publications Christopher D. Nguyen
Tufts Univ. (United States)
2 shared publications
Latest Publications
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Thermal investigations on polymer dispersed liquid crystal composites and thermo-electric polymer composites using photothermal techniques
Caractérisations thermiques de composites polymères dispersés dans du cristal liquide et de matériaux composites thermoélectriques à base de polymères avec les techniques photothermiques: Dans une première partie, une nouvelle méthodologie, précise et hautement sensible de caractérisation des paramètres thermiques de liquides par radiométrie photothermique est ici présentée. Deux configurations expérimentales sont proposées. Elles ont été testées et validées avec des matériaux liquides usuels aux paramètres thermiques connus. Par la suite, cette démarche a été utilisée pour l'étude de polymères dispersés dans des cristaux liquides. Les propriétés thermiques dynamiques de chaque échantillon ont été mesurées en fonction de l'amplitude du champ électrique appliqué à une fréquence donnée aussi bien qu'en fonction de la fréquence du champ électrique à une amplitude fixe. Cette étude a montré que les propriétés thermiques étaient sujettes aux effets du champ de dépolarisation aux basses fréquences. La seconde partie de ce manuscrit décrit la nouvelle technique photothermique basée sur l'effet thermoélectrique. Cette technique est utile pour caractériser thermiquement les matériaux thermoélectriques sans avoir à recourir à un capteur extérieur pour mesurer le changement de température. Une étude théorique et expérimentale est présentée. Ces expériences ont été réalisées avec des composites polyaniline/nanotubes de carbone par mesure de la tension générée par l'échantillon thermoélectrique chauffé par un faisceau laser. Des mesures additionnelles à l'aide de la radiométrie infrarouge sur ces mêmes échantillons ont été entreprises et les résultats sont en bon accord avec ceux précédemment trouvés. Enfin, la possibilité d'utiliser les matériaux thermoélectriques comme capteur photothermique au travers d'une cavité résonnante à ondes thermiques est évoquée.
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Thermal investigations on polymer dispersed liquid crystal composites and thermo-electric polymer composites using photothermal techniques
Caractérisations thermiques de composites polymères dispersés dans du cristal liquide et de matériaux composites thermoélectriques à base de polymères avec les techniques photothermiques: Dans une première partie, une nouvelle méthodologie, précise et hautement sensible de caractérisation des paramètres thermiques de liquides par radiométrie photothermique est ici présentée. Deux configurations expérimentales sont proposées. Elles ont été testées et validées avec des matériaux liquides usuels aux paramètres thermiques connus. Par la suite, cette démarche a été utilisée pour l'étude de polymères dispersés dans des cristaux liquides. Les propriétés thermiques dynamiques de chaque échantillon ont été mesurées en fonction de l'amplitude du champ électrique appliqué à une fréquence donnée aussi bien qu'en fonction de la fréquence du champ électrique à une amplitude fixe. Cette étude a montré que les propriétés thermiques étaient sujettes aux effets du champ de dépolarisation aux basses fréquences. La seconde partie de ce manuscrit décrit la nouvelle technique photothermique basée sur l'effet thermoélectrique. Cette technique est utile pour caractériser thermiquement les matériaux thermoélectriques sans avoir à recourir à un capteur extérieur pour mesurer le changement de température. Une étude théorique et expérimentale est présentée. Ces expériences ont été réalisées avec des composites polyaniline/nanotubes de carbone par mesure de la tension générée par l'échantillon thermoélectrique chauffé par un faisceau laser. Des mesures additionnelles à l'aide de la radiométrie infrarouge sur ces mêmes échantillons ont été entreprises et les résultats sont en bon accord avec ceux précédemment trouvés. Enfin, la possibilité d'utiliser les matériaux thermoélectriques comme capteur photothermique au travers d'une cavité résonnante à ondes thermiques est évoquée.
- 15 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12381, PC1238105
Elastographic resolution in the dynamic OCE of bounded nearly incompressible media (Conference Presentation)
Dynamic optical coherence elastography (OCE) tracks mechanical wave propagation in the subsurface region of tissue to map its shear modulus. For bulk shear waves, the lateral resolution of the reconstructed modulus map (i.e., elastographic resolution) can approach that for OCT, typically a few tens of microns. However, skin, cornea and many other tissues are layered or bounded leading to the formation of guided mechanical waves. We performed numerical simulations and acoustic micro-tapping experiments to show that in bounded media, the elastographic resolution cannot reach the OCT structural resolution and is mainly defined by the thickness of the bounded tissue layer.
- 15 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12381, PC1238105
Elastographic resolution in the dynamic OCE of bounded nearly incompressible media (Conference Presentation)
Dynamic optical coherence elastography (OCE) tracks mechanical wave propagation in the subsurface region of tissue to map its shear modulus. For bulk shear waves, the lateral resolution of the reconstructed modulus map (i.e., elastographic resolution) can approach that for OCT, typically a few tens of microns. However, skin, cornea and many other tissues are layered or bounded leading to the formation of guided mechanical waves. We performed numerical simulations and acoustic micro-tapping experiments to show that in bounded media, the elastographic resolution cannot reach the OCT structural resolution and is mainly defined by the thickness of the bounded tissue layer.
- 1 October 2021
- Published by Elsevier in Current Opinion in Colloid & Interface Science
- Vol. 55
Microbubbles and Nanodrops for photoacoustic tomography
- 1 October 2021
- Published by Elsevier in Current Opinion in Colloid & Interface Science
- Vol. 55
Microbubbles and Nanodrops for photoacoustic tomography
- 6 March 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11642, 1164244
Modular and flexible 3D printed holder for deep tissue imaging with LED array based photoacoustic imaging
Low cost and high-power LED’s are replacing highly expensive and bulky Lasers in photoacoustic imaging (PAI) technology. LEDs bring the opportunity to image samples at a higher repetition rate (in kHz) compared to the conventional Q switched lasers (typically upto 20 Hz) and thus offer high frame rate and averaging power while maintain real-time imaging capability. In order to make a complete switch from Laser to LEDs, a proper understanding of this newly emerging class of LED arrays is important, for e.g., beam divergence, beam focus, coherence, time-dependent power and wavelength stability, penetration depth and sensitivity, etc. We performed characterization and optimization experiments on different tissue mimicking phantoms with various optical scattering and absorbing properties using a commercially available AcousticX PAI system with customized 3D printed holders for the LED array. The axial and lateral positions of LED arrays with respect to the acoustic probe to image deep lesions upto 1.5 cm were optimized. We also report the sensitivity of the system and Signal-to-noise-ratio (SNR) dependency of the LED arrays’ axial and lateral positions. Finally, we also demonstrate the adaptability of our custom designed, 3D printed variable angle and distance holder to perform deep tissue ultrasound and photoacoustic imaging probe on phantoms of with absorbers at different depth and in subcutaneous tumors and compare it with traditional laser based photoacoustic imaging systems.
- 6 March 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11642, 1164244
Modular and flexible 3D printed holder for deep tissue imaging with LED array based photoacoustic imaging
Low cost and high-power LED’s are replacing highly expensive and bulky Lasers in photoacoustic imaging (PAI) technology. LEDs bring the opportunity to image samples at a higher repetition rate (in kHz) compared to the conventional Q switched lasers (typically upto 20 Hz) and thus offer high frame rate and averaging power while maintain real-time imaging capability. In order to make a complete switch from Laser to LEDs, a proper understanding of this newly emerging class of LED arrays is important, for e.g., beam divergence, beam focus, coherence, time-dependent power and wavelength stability, penetration depth and sensitivity, etc. We performed characterization and optimization experiments on different tissue mimicking phantoms with various optical scattering and absorbing properties using a commercially available AcousticX PAI system with customized 3D printed holders for the LED array. The axial and lateral positions of LED arrays with respect to the acoustic probe to image deep lesions upto 1.5 cm were optimized. We also report the sensitivity of the system and Signal-to-noise-ratio (SNR) dependency of the LED arrays’ axial and lateral positions. Finally, we also demonstrate the adaptability of our custom designed, 3D printed variable angle and distance holder to perform deep tissue ultrasound and photoacoustic imaging probe on phantoms of with absorbers at different depth and in subcutaneous tumors and compare it with traditional laser based photoacoustic imaging systems.
- Open Access
Optimizing Irradiation Geometry in LED-Based Photoacoustic Imaging with 3D Printed Flexible and Modular Light Delivery System
Photoacoustic (PA) imaging–a technique combining the ability of optical imaging to probe functional properties of the tissue and deep structural imaging ability of ultrasound–has gained significant popularity in the past two decades for its utility in several biomedical applications. More recently, light-emitting diodes (LED) are being explored as an alternative to bulky and expensive laser systems used in PA imaging for their portability and low-cost. Due to the large beam divergence of LEDs compared to traditional laser beams, it is imperative to quantify the angular dependence of LED-based illumination and optimize its performance for imaging superficial or deep-seated lesions. A custom-built modular 3-D printed hinge system and tissue-mimicking phantoms with various absorption and scattering properties were used in this study to quantify the angular dependence of LED-based illumination. We also experimentally calculated the source divergence of the pulsed-LED arrays to be 58° ± 8°. Our results from point sources (pencil lead phantom) in non-scattering medium obey the cotangential relationship between the angle of irradiation and maximum PA intensity obtained at various imaging depths, as expected. Strong dependence on the angle of illumination at superficial depths (−5°/mm at 10 mm) was observed that becomes weaker at intermediate depths (−2.5°/mm at 20 mm) and negligible at deeper locations (−1.1°/mm at 30 mm). The results from the tissue-mimicking phantom in scattering media indicate that angles between 30–75° could be used for imaging lesions at various depths (12 mm–28 mm) where lower LED illumination angles (closer to being parallel to the imaging plane) are preferable for deep tissue imaging and superficial lesion imaging is possible with higher LED illumination angles (closer to being perpendicular to the imaging plane). Our results can serve as a priori knowledge for the future LED-based PA system designs employed for both preclinical and clinical applications.
Open AccessOptimizing Irradiation Geometry in LED-Based Photoacoustic Imaging with 3D Printed Flexible and Modular Light Delivery System
Photoacoustic (PA) imaging–a technique combining the ability of optical imaging to probe functional properties of the tissue and deep structural imaging ability of ultrasound–has gained significant popularity in the past two decades for its utility in several biomedical applications. More recently, light-emitting diodes (LED) are being explored as an alternative to bulky and expensive laser systems used in PA imaging for their portability and low-cost. Due to the large beam divergence of LEDs compared to traditional laser beams, it is imperative to quantify the angular dependence of LED-based illumination and optimize its performance for imaging superficial or deep-seated lesions. A custom-built modular 3-D printed hinge system and tissue-mimicking phantoms with various absorption and scattering properties were used in this study to quantify the angular dependence of LED-based illumination. We also experimentally calculated the source divergence of the pulsed-LED arrays to be 58° ± 8°. Our results from point sources (pencil lead phantom) in non-scattering medium obey the cotangential relationship between the angle of irradiation and maximum PA intensity obtained at various imaging depths, as expected. Strong dependence on the angle of illumination at superficial depths (−5°/mm at 10 mm) was observed that becomes weaker at intermediate depths (−2.5°/mm at 20 mm) and negligible at deeper locations (−1.1°/mm at 30 mm). The results from the tissue-mimicking phantom in scattering media indicate that angles between 30–75° could be used for imaging lesions at various depths (12 mm–28 mm) where lower LED illumination angles (closer to being parallel to the imaging plane) are preferable for deep tissue imaging and superficial lesion imaging is possible with higher LED illumination angles (closer to being perpendicular to the imaging plane). Our results can serve as a priori knowledge for the future LED-based PA system designs employed for both preclinical and clinical applications.
- Open Access
- 30 June 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 25 (06) , 069802-1
Mutual impact of clinically translatable near-infrared dyes on photoacoustic image contrast and in vitro photodynamic therapy efficacy (Erratum)
The erratum corrects an error in the y-axis labels of Fig. 4 and Fig. S2.
- 30 June 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 25 (06) , 069802-1
Open AccessMutual impact of clinically translatable near-infrared dyes on photoacoustic image contrast and in vitro photodynamic therapy efficacy (Erratum)
The erratum corrects an error in the y-axis labels of Fig. 4 and Fig. S2.
- Open Access
- 28 February 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 25 (06) , 1-12
Mutual impact of clinically translatable near-infrared dyes on photoacoustic image contrast and in vitro photodynamic therapy efficacy
Photodynamic therapy (PDT), a spatially localized phototoxic therapy that involves irradiation of a photosensitizer (PS) with specific wavelengths of light, has shown exceptional promise in impacting cancer treatment outcomes, particularly oral cancer. To reduce PDT outcome variability, attempts toward image-guided personalized PDT are being pursued by monitoring PS uptake either via fluorescence or photoacoustic imaging (PAI), a nonionizing modality dependent on optical absorption properties of the tissue. PAI-guided PDT requires a near-infrared contrast agent for deep tissue imaging with minimal photobleaching effect. We evaluate the impact of PDT agent, benzoporphyrin derivative (BPD), on PAI agent indocyanine green (ICG) and vice versa, given that they have different optical absorption properties and singlet oxygen quantum yields for PDT. Specifically, we demonstrate in two oral squamous cell carcinoma lines (FaDu and SCC4) that ICG has minimal effect on BPD PDT efficacy when irradiated with either a continuous or pulsed laser. Furthermore, the impact of BPD on ICG photodegradation was monitored with PAI in tissue-mimicking phantoms. These studies inform us that the combination of BPD and ICG can be utilized for PAI-guided PDT. However, researchers need to consider the photodegradation effects of ICG in the presence of BPD when designing their drug delivery strategies for PAI-guided PDT.
- 28 February 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 25 (06) , 1-12
Open AccessMutual impact of clinically translatable near-infrared dyes on photoacoustic image contrast and in vitro photodynamic therapy efficacy
Photodynamic therapy (PDT), a spatially localized phototoxic therapy that involves irradiation of a photosensitizer (PS) with specific wavelengths of light, has shown exceptional promise in impacting cancer treatment outcomes, particularly oral cancer. To reduce PDT outcome variability, attempts toward image-guided personalized PDT are being pursued by monitoring PS uptake either via fluorescence or photoacoustic imaging (PAI), a nonionizing modality dependent on optical absorption properties of the tissue. PAI-guided PDT requires a near-infrared contrast agent for deep tissue imaging with minimal photobleaching effect. We evaluate the impact of PDT agent, benzoporphyrin derivative (BPD), on PAI agent indocyanine green (ICG) and vice versa, given that they have different optical absorption properties and singlet oxygen quantum yields for PDT. Specifically, we demonstrate in two oral squamous cell carcinoma lines (FaDu and SCC4) that ICG has minimal effect on BPD PDT efficacy when irradiated with either a continuous or pulsed laser. Furthermore, the impact of BPD on ICG photodegradation was monitored with PAI in tissue-mimicking phantoms. These studies inform us that the combination of BPD and ICG can be utilized for PAI-guided PDT. However, researchers need to consider the photodegradation effects of ICG in the presence of BPD when designing their drug delivery strategies for PAI-guided PDT.
- Open Access
- 20 February 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (4) , 736
Evaluation of the Structural Phase Transition in Multiferroic (Bi1−x Prx)(Fe0.95 Mn0.05)O3 Thin Films by A Multi-Technique Approach Including Picosecond Laser Ultrasonics
Picosecond laser ultrasonics is an experimental technique for the generation and detection of ultrashort acoustic pulses using ultrafast lasers. In transparent media, it is often referred to as time-domain Brillouin scattering (TDBS). It provides the opportunity to monitor the propagation of nanometers-length acoustic pulses and to determine acoustical, optical, and acousto-optical parameters of the materials. We report on the application of TDBS for evaluating the effect of Praseodymium (Pr) substitution on the elasticity of multiferroic (Bi1−xPrx)(Fe0.95Mn0.05)O3 (BPFMO) thin films. The films were deposited on Si and LaAlO3 (LAO) substrates by a sol-gel method. X-ray diffraction and Raman spectra revealed earlier that a phase transition from rhombohedral to tetragonal structure occurs at about 15% Pr substitution and is accompanied by the maxima of remnant magnetization and polarization. Combining TDBS with optical spectral reflectometry, scanning electron microscopy, and topographic measurements by atomic force microscopy, we found that the structural transition is also characterized by the maximum optical dielectric constant and the minimum longitudinal sound velocity. Our results, together with earlier ones, suggest that BiFeO3-based films and ceramics with compositions near phase boundaries might be promising materials for multifunctional applications.
- 20 February 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (4) , 736
Open AccessEvaluation of the Structural Phase Transition in Multiferroic (Bi1−x Prx)(Fe0.95 Mn0.05)O3 Thin Films by A Multi-Technique Approach Including Picosecond Laser Ultrasonics
Picosecond laser ultrasonics is an experimental technique for the generation and detection of ultrashort acoustic pulses using ultrafast lasers. In transparent media, it is often referred to as time-domain Brillouin scattering (TDBS). It provides the opportunity to monitor the propagation of nanometers-length acoustic pulses and to determine acoustical, optical, and acousto-optical parameters of the materials. We report on the application of TDBS for evaluating the effect of Praseodymium (Pr) substitution on the elasticity of multiferroic (Bi1−xPrx)(Fe0.95Mn0.05)O3 (BPFMO) thin films. The films were deposited on Si and LaAlO3 (LAO) substrates by a sol-gel method. X-ray diffraction and Raman spectra revealed earlier that a phase transition from rhombohedral to tetragonal structure occurs at about 15% Pr substitution and is accompanied by the maxima of remnant magnetization and polarization. Combining TDBS with optical spectral reflectometry, scanning electron microscopy, and topographic measurements by atomic force microscopy, we found that the structural transition is also characterized by the maximum optical dielectric constant and the minimum longitudinal sound velocity. Our results, together with earlier ones, suggest that BiFeO3-based films and ceramics with compositions near phase boundaries might be promising materials for multifunctional applications.
- Open Access
- 1 May 2017
- Published by IOP Publishing in New Journal of Physics
- Vol. 19 (5) , 053026
In situimaging of the dynamics of photo-induced structural phase transition at high pressures by picosecond acoustic interferometry
Picosecond acoustic interferometry is used to monitor in time the motion of the phase transition boundary between two water ice phases, VII and VI, coexisting at a pressure of 2.15 GPa when compressed in a diamond anvil cell at room temperature. By analyzing the time-domain Brillouin scattering signals accumulated for a single incidence direction of probe laser pulses, it is possible to access ratios of sound velocity values and of the refractive indices of the involved phases, and to distinguish between the structural phase transition and a recrystallization process. Two-dimensional spatial imaging of the phase transition dynamics indicates that it is initiated by the pump and probe laser pulses, preferentially at the diamond/ice interface. This method should find applications in three-dimensional monitoring with nanometer spatial resolution of the temporal dynamics of low-contrast material inhomogeneities caused by phase transitions or chemical reactions in optically transparent media.
- 1 May 2017
- Published by IOP Publishing in New Journal of Physics
- Vol. 19 (5) , 053026
Open AccessIn situimaging of the dynamics of photo-induced structural phase transition at high pressures by picosecond acoustic interferometry
Picosecond acoustic interferometry is used to monitor in time the motion of the phase transition boundary between two water ice phases, VII and VI, coexisting at a pressure of 2.15 GPa when compressed in a diamond anvil cell at room temperature. By analyzing the time-domain Brillouin scattering signals accumulated for a single incidence direction of probe laser pulses, it is possible to access ratios of sound velocity values and of the refractive indices of the involved phases, and to distinguish between the structural phase transition and a recrystallization process. Two-dimensional spatial imaging of the phase transition dynamics indicates that it is initiated by the pump and probe laser pulses, preferentially at the diamond/ice interface. This method should find applications in three-dimensional monitoring with nanometer spatial resolution of the temporal dynamics of low-contrast material inhomogeneities caused by phase transitions or chemical reactions in optically transparent media.
- 1 July 2016
- Published by Elsevier in Ultrasonics
- Vol. 69, 259-267
Picosecond laser ultrasonics for imaging of transparent polycrystalline materials compressed to megabar pressures
- 1 July 2016
- Published by Elsevier in Ultrasonics
- Vol. 69, 259-267
Picosecond laser ultrasonics for imaging of transparent polycrystalline materials compressed to megabar pressures