Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Supapradit Marsong has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Yuttana Kongjeen

    Intelligent Power System and Energy Research (IPER), Department of Electrical engineering, Faculty of Engineering and Technology, Rajamangala University of Technology Isan, Nakhon Ratchasima 30000, Thailand

    4 shared publications
  • Kaan Kerdchuen

    Intelligent Power System and Energy Research (IPER), Department of Electrical engineering, Faculty of Engineering and Technology, Rajamangala University of Technology Isan, Nakhon Ratchasima 30000, Thailand

    3 shared publications
  • Krischonme Bhumkittipich

    Department of Electrical Engineering, Faculty of Engineering, Rajamangala University of Technology Thanyaburi, Pathum Thani 12110, Thailand

    3 shared publications
  • Wutthichai Sa-Nga-Ngam

    Intelligent Power System and Energy Research (IPER), Department of Electrical engineering, Faculty of Engineering and Technology, Rajamangala University of Technology Isan, Nakhon Ratchasima 30000, Thailand

    3 shared publications
  • Krittidet Buayai

    Intelligent Power System and Energy Research (IPER), Department of Electrical Engineering, Faculty of Engineering and Technology, Rajamangala University of Technology Isan Nakhon Ratchasima, Nakhon Ratchasima 30000, Thailand

    2 shared publications
  • Pongsuk Pilalum

    Intelligent Power System and Energy Research (IPER), Department of Electrical engineering, Faculty of Engineering and Technology, Rajamangala University of Technology Isan, Nakhon Ratchasima 30000, Thailand

    2 shared publications

Latest Publications

  • Open Access

    Techno-economic evaluation of PV–vanadium redox flow battery systems for peak shaving in football stadiums under time-of-use tariffs

    by Surasak Noituptim, Sawek Pratummet, Wanwinit Wijittemee, Akeratana Noppakant, Supapradit Marsong, Sarun Nakthanom, Boonyang Plangklang

  • Open Access

    Multi-Objective Optimization of Mobile Battery Energy Storage and Dynamic Feeder Reconfiguration for Enhanced Voltage Profiles in Active Distribution Systems

    by Phuwanat Marksan, Krittidet Buayai, Ritthichai Ratchapan, Wutthichai Sa-Nga-Ngam, Krischonme Bhumkittipich, Kaan Kerdchuen, Ingo Stadler, Supapradit Marsong, Yuttana Kongjeen

    Active distribution systems (ADS) are increasingly strained by rising energy demand and the widespread deployment of distributed energy resources (DERs) and electric vehicle charging stations (EVCS), which intensify voltage deviations, power losses, and peak demand fluctuations. This study develops a coordinated optimization framework for Mobile Battery Energy Storage Systems (MBESS) and Dynamic Feeder Reconfiguration (DFR) to enhance network performance across technical, economic, and environmental dimensions. A Non-dominated Sorting Genetic Algorithm III (NSGA-III) is employed to minimize six objectives the active and reactive power losses, voltage deviation index (VDI), voltage stability index (FVSI), operating cost, and CO2 emissions while explicitly modeling the MBESS transportation constraints such as energy consumption and single-trip mobility within coupled IEEE 33-bus and 33-node transport networks, which provide realistic mobility modeling of energy storage operations. The Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) is applied to select compromise solutions from Pareto fronts. Simulation results across six scenarios show that the coordinated MBESS–DFR operation reduces power losses by 27.8–30.1%, improves the VDI by 40.5–43.2%, and enhances the FVSI by 2.3–2.4%, maintaining all bus voltages within 0.95–1.05 p.u. with minimal cost (0.26–0.27%) and emission variations (0.31–0.71%). The MBESS alone provided limited benefits (5–12%), confirming that coordination is essential for improving efficiency, voltage regulation, and overall system sustainability in renewable-rich distribution networks.


  • Open Access

    Multi-Objective Optimization of Distributed Generation Placement in Electric Bus Transit Systems Integrated with Flash Charging Station Using Enhanced Multi-Objective Grey Wolf Optimization Technique and Consensus-Based Decision Support

    by Yuttana Kongjeen, Pongsuk Pilalum, Saksit Deeum, Kittiwong Suthamno, Thongchai Klayklueng, Supapradit Marsong, Ritthichai Ratchapan, Krittidet Buayai, Kaan Kerdchuen, Wutthichai Sa-Nga-Ngam, et al.

    This study presents a comprehensive multi-objective optimization framework for optimal placement and sizing of distributed generation (DG) units in electric bus (E-bus) transit systems integrated with a high-power flash charging infrastructure. An enhanced Multi-Objective Grey Wolf Optimizer (MOGWO), utilizing Euclidean distance-based Pareto ranking, is developed to minimize power loss, voltage deviation, and voltage violations. The framework incorporates realistic E-bus operation characteristics, including a 31-stop, 62 km route, 600 kW pantograph flash chargers, and dynamic load profiles over a 90 min simulation period. Statistical evaluation on IEEE 33-bus and 69-bus distribution networks demonstrates that MOGWO consistently outperforms MOPSO and NSGA-II across all DG deployment scenarios. In the three-DG configuration, MOGWO achieved minimum power losses of 0.0279 MW and 0.0179 MW, and voltage deviations of 0.1313 and 0.1362 in the 33-bus and 69-bus systems, respectively, while eliminating voltage violations. The proposed method also demonstrated superior solution quality with low variance and faster convergence, requiring under 7 h of computation on average. A five-method compromise solution strategy, including TOPSIS and Lp-metric, enabled transparent and robust decision-making. The findings confirm the proposed framework’s effectiveness and scalability for enhancing distribution system performance under the demands of electric transit electrification and smart grid integration.


  • Open Access

    Mitigation of Voltage Magnitude Profiles Under High-Penetration-Level Fast-Charging Stations Using Optimal Capacitor Placement Integrated with Renewable Energy Resources in Unbalanced Distribution Networks

    by Pongsuk Pilalum, Radomboon Taksana, Noppanut Chitgreeyan, Wutthichai Sa-Nga-Ngam, Supapradit Marsong, Krittidet Buayai, Kaan Kerdchuen, Yuttana Kongjeen, Krischonme Bhumkittipich

    The rapid adoption of electric vehicles (EVs) and the increasing use of photovoltaic (PV) generation have introduced new operational challenges for unbalanced power distribution systems. These include elevated power losses, voltage imbalances, and adverse environmental impacts. This study proposed a hybrid objective optimization framework to address these issues by minimizing real and reactive power losses, voltage deviations, voltage imbalance indexes, and CO2 emissions. Nineteen simulation cases were analyzed under various configurations incorporating EV integration, PV deployment, reactive power compensation, and zonal control strategies. An improved gray wolf optimizer (IGWO) was employed to determine optimal placements and control settings. Among all cases, Case 16 yielded the lowest objective function value, representing the most effective trade-off between technical performance, voltage stability, and sustainability. The optimized configuration significantly improved the voltage balance, reduced system losses, and maintained the average voltage within acceptable limits. Additionally, all optimized scenarios achieved meaningful reductions in CO2 emissions compared to the base case. The results were validated with an objective function Fbest as a reliable composite performance index and demonstrated the effectiveness of coordinated zone-based optimization. This approach provides practical insights for future smart grid planning under dynamic, renewable, rich, and EV-dominated operating conditions.


  • Open Access

    Vertical Transportation System Power Usage: Behavioural Case Study of Regulated Buildings in Bangkok

    by Supapradit Marsong, Yuttana Kongjeen, Boonyang Plangklang

    Sustainable urban development worldwide is crucial for the development of living spaces in high-rise buildings and infrastructures, which leads to the inevitability of increased energy consumption and demand of vertical transportation systems. The evaluation of the energy consumption of transportation systems is needed to verify and analyse the power usage related to traffic demands and patterns. In addition, efficient vertical transportation systems are central to the formulation of more sustainable cities. Therefore, this trend represents a substantial portion of the overall energy consumption of the building types. The benchmarking of the energy needs of the vertical transportation systems in five different building types via the comparison of granular load profile patterns (in conjunction with population densities) to the energy consumed was conducted, and it will be used to infer some impactful design strategies for the future. This study demonstrated a systematic approach to determine the power usage patterns in vertical transportation systems by actual measurement and traffic data collection from elevator monitoring. This may be used to develop a prediction for other cases in different types of installed vertical transportation systems. Therefore, the power usage of the vertical transportation systems can be used to determine the correlation between energy consumption and load pattern based on building characteristics and the overall energy consumption of each presented system.