Teruyoshi Oda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Teruyoshi Oda has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Kazunari Ishii
Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
4 shared publications - Masakatsu Tsurusaki
Department of Radiology, Kindai University Faculty of Medicine
4 shared publications - Yukinobu Yagyu
Department of Radiology, Faculty of Medicine, Kindai University, 377-2 Ohnohigashi, Osakasayama, Osaka 589-8511, Japan
4 shared publications - Isao Numoto
Department of Radiology, Faculty of Medicine, Kindai University, 377-2 Ohnohigashi, Osakasayama, Osaka 589-8511, Japan
3 shared publications - Ayako Suzuki
Radiology
2 shared publications - Takamichi Murakami
Department of Radiology, Kobe University Graduate School of Medicine
2 shared publications
Latest Publications
- Open Access
Correction: Isao N., et al. Transcatheter Arterial Embolization Treatment for Bleeding Visceral Artery Pseudoaneurysms in Patients with Pancreatitis or Following Pancreatic Surgery. Cancers 2020, 12, 2733
The authors are sorry to report that the overall survival reported in their recently published paper was incorrect
Open AccessCorrection: Isao N., et al. Transcatheter Arterial Embolization Treatment for Bleeding Visceral Artery Pseudoaneurysms in Patients with Pancreatitis or Following Pancreatic Surgery. Cancers 2020, 12, 2733
The authors are sorry to report that the overall survival reported in their recently published paper was incorrect
- Open Access
Transcatheter Arterial Embolization Treatment for Bleeding Visceral Artery Pseudoaneurysms in Patients with Pancreatitis or following Pancreatic Surgery
Purpose: To evaluate the efficacy and safety of transcatheter arterial embolization (TAE) for pseudoaneurysms occurring secondary to pancreatitis or because of leakage of pancreatic juice after pancreatectomy. Materials and Methods: This retrospective study included 42 consecutive patients (38 males and 4 females; mean age, 60 years; range, 33–80 years) who underwent TAE for bleeding visceral artery pseudoaneurysms between March 2004 and December 2018. The technical and clinical success rates, incidence of recurrent bleeding and complications, including pancreatitis, were evaluated. Results: Of the 42 enrolled patients, 23 had bleeding due to a complication of pancreatectomy and 19 had bleeding as a complication of pancreatitis. TAE with N-butyl cyanoacrylate (NBCA) or NBCA plus microcoils recurrent bleeding or inability to control bleeding was 15.8% (3 of 19) following TAE with NBCA and 17.4% (4 of 23) following TAE with coils. No clinically significant ischemic events of the pancreas or duodenum were observed in the embolized areas. Serum amylase did not increase compared with the initial levels after any of the procedures. At 30 days after TAE, 32 patients were alive. Conclusion: TAE has a high success rate for the management of hemorrhage, with few complications. The procedure appears to be safe and effective for pseudoaneurysms associated with either pancreatitis or pancreatectomy.
Open AccessTranscatheter Arterial Embolization Treatment for Bleeding Visceral Artery Pseudoaneurysms in Patients with Pancreatitis or following Pancreatic Surgery
Purpose: To evaluate the efficacy and safety of transcatheter arterial embolization (TAE) for pseudoaneurysms occurring secondary to pancreatitis or because of leakage of pancreatic juice after pancreatectomy. Materials and Methods: This retrospective study included 42 consecutive patients (38 males and 4 females; mean age, 60 years; range, 33–80 years) who underwent TAE for bleeding visceral artery pseudoaneurysms between March 2004 and December 2018. The technical and clinical success rates, incidence of recurrent bleeding and complications, including pancreatitis, were evaluated. Results: Of the 42 enrolled patients, 23 had bleeding due to a complication of pancreatectomy and 19 had bleeding as a complication of pancreatitis. TAE with N-butyl cyanoacrylate (NBCA) or NBCA plus microcoils recurrent bleeding or inability to control bleeding was 15.8% (3 of 19) following TAE with NBCA and 17.4% (4 of 23) following TAE with coils. No clinically significant ischemic events of the pancreas or duodenum were observed in the embolized areas. Serum amylase did not increase compared with the initial levels after any of the procedures. At 30 days after TAE, 32 patients were alive. Conclusion: TAE has a high success rate for the management of hemorrhage, with few complications. The procedure appears to be safe and effective for pseudoaneurysms associated with either pancreatitis or pancreatectomy.
- Open Access
- 26 June 2020
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 38 (11) , 1052-1061
Efficiency of a computer-aided diagnosis (CAD) system with deep learning in detection of pulmonary nodules on 1-mm-thick images of computed tomography
Purpose To evaluate the performance of a deep learning-based computer-aided diagnosis (CAD) system at detecting pulmonary nodules on CT by comparing radiologists’ readings with and without CAD. Materials and methods A total of 120 chest CT images were randomly selected from patients with suspected lung cancer. The gold standard of nodules ≥ 3 mm was established by a panel of three expert radiologists. Two less experienced radiologists read the images without and afterward with CAD system. Their reading times were recorded. Results The radiologists’ sensitivity increased from 20.9% to 38.0% with the introduction of CAD. The positive predictive value (PPV) decreased from 70.5% to 61.8%, and the F1-score increased from 32.2% to 47.0%. The sensitivity significantly increased from 13.7% to 32.4% for small nodules (3–6 mm) and from 33.3% to 47.6% for medium nodules (6–10 mm). CAD alone showed a sensitivity of 70.3%, a PPV of 57.9%, and an F1-score of 63.5%. Reading time decreased by 11.3% with the use of CAD. Conclusion CAD improved the less experienced radiologists’ sensitivity in detecting pulmonary nodules of all sizes, especially including a significant improvement in the detection of clinically important-sized medium nodules (6–10 mm) as well as small nodules (3–6 mm) and reduced their reading time.
- 26 June 2020
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 38 (11) , 1052-1061
Open AccessEfficiency of a computer-aided diagnosis (CAD) system with deep learning in detection of pulmonary nodules on 1-mm-thick images of computed tomography
Purpose To evaluate the performance of a deep learning-based computer-aided diagnosis (CAD) system at detecting pulmonary nodules on CT by comparing radiologists’ readings with and without CAD. Materials and methods A total of 120 chest CT images were randomly selected from patients with suspected lung cancer. The gold standard of nodules ≥ 3 mm was established by a panel of three expert radiologists. Two less experienced radiologists read the images without and afterward with CAD system. Their reading times were recorded. Results The radiologists’ sensitivity increased from 20.9% to 38.0% with the introduction of CAD. The positive predictive value (PPV) decreased from 70.5% to 61.8%, and the F1-score increased from 32.2% to 47.0%. The sensitivity significantly increased from 13.7% to 32.4% for small nodules (3–6 mm) and from 33.3% to 47.6% for medium nodules (6–10 mm). CAD alone showed a sensitivity of 70.3%, a PPV of 57.9%, and an F1-score of 63.5%. Reading time decreased by 11.3% with the use of CAD. Conclusion CAD improved the less experienced radiologists’ sensitivity in detecting pulmonary nodules of all sizes, especially including a significant improvement in the detection of clinically important-sized medium nodules (6–10 mm) as well as small nodules (3–6 mm) and reduced their reading time.
- Open Access
Assessment of Liver Metastases Using CT and MRI Scans in Patients with Pancreatic Ductal Adenocarcinoma: Effects of Observer Experience on Diagnostic Accuracy
The aim of this study was to investigate the impact of radiologic experience on the diagnostic accuracy of computed tomography (CT) vs. magnetic resonance imaging (MRI) reporting on the liver metastases of pancreatic ductal adenocarcinoma (LM of PDAC). Intra-individual CT and MRI examinations of 112 patients with clinically proven LM of PDAC were included. Four radiologists with varying years of experience (A > 20, B > 5, C > 1 and D < 1) assessed liver segments affected by LM of PDAC, as well as associated metastases occurring in each patient. Their sensitivity and specificity in evaluating the segments were compared. Cohen’s Kappa (κ) for diagnosed liver segments and Intra-class Correlation Coefficients (ICC) for the number of metastatic lesions in each patient were calculated. The radiologists’ sensitivity and specificity for the CT vs. MRI were, respectively: Reader A—94.4%, 90.3% vs. 96.6%, 94.8%; B—86.7%, 79.7% vs. 83.9%, 82.0%; C—78.0%, 76.7% vs. 83.3%, 78.9% and D—71.8%, 79.2% vs. 64.0%, 69.5%. Reviewers A and B achieved greater agreement in assessing results from the MRI (κ = 0.72, p < 0.001; ICC = 0.73, p < 0.001) vs. the CT (κ = 0.58, p < 0.001; ICC = 0.61, p < 0.001), in contrast to readers C and D (MRI: κ = 0.34, p < 0.001; ICC = 0.42, p < 0.001, and CT: κ = 0.48, p < 0.001; ICC = 0.59, p < 0.001). Our results indicate that the accurate diagnosis of LM of PDAC depends more on radiologic experience in MRI over CT scans.
Open AccessAssessment of Liver Metastases Using CT and MRI Scans in Patients with Pancreatic Ductal Adenocarcinoma: Effects of Observer Experience on Diagnostic Accuracy
The aim of this study was to investigate the impact of radiologic experience on the diagnostic accuracy of computed tomography (CT) vs. magnetic resonance imaging (MRI) reporting on the liver metastases of pancreatic ductal adenocarcinoma (LM of PDAC). Intra-individual CT and MRI examinations of 112 patients with clinically proven LM of PDAC were included. Four radiologists with varying years of experience (A > 20, B > 5, C > 1 and D < 1) assessed liver segments affected by LM of PDAC, as well as associated metastases occurring in each patient. Their sensitivity and specificity in evaluating the segments were compared. Cohen’s Kappa (κ) for diagnosed liver segments and Intra-class Correlation Coefficients (ICC) for the number of metastatic lesions in each patient were calculated. The radiologists’ sensitivity and specificity for the CT vs. MRI were, respectively: Reader A—94.4%, 90.3% vs. 96.6%, 94.8%; B—86.7%, 79.7% vs. 83.9%, 82.0%; C—78.0%, 76.7% vs. 83.3%, 78.9% and D—71.8%, 79.2% vs. 64.0%, 69.5%. Reviewers A and B achieved greater agreement in assessing results from the MRI (κ = 0.72, p < 0.001; ICC = 0.73, p < 0.001) vs. the CT (κ = 0.58, p < 0.001; ICC = 0.61, p < 0.001), in contrast to readers C and D (MRI: κ = 0.34, p < 0.001; ICC = 0.42, p < 0.001, and CT: κ = 0.48, p < 0.001; ICC = 0.59, p < 0.001). Our results indicate that the accurate diagnosis of LM of PDAC depends more on radiologic experience in MRI over CT scans.