ASAgung Wahyu Setiawan

Agung Wahyu Setiawan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Agung Wahyu Setiawan has a total of 74 co-authors. Here are the top co-authors by number of shared publications:

  • Tati R. Mengko

    Biomedicai Engineering Research Group, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia

    7 shared publications
  • Andriyan B. Suksmono

    School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia

    5 shared publications
  • Astri Handayani

    Biomedical Engineering Program, School of Electrical Engineering and Informatics, Bandung Institute of Technology, Bandung, Indonesia

    4 shared publications
  • Minoru Sasaki

    Department of Mechanical Engineering, Gifu University, Gifu, Japan

    3 shared publications
  • Alfie Rizky Ananda

    Bandung Institute of Technology,Biomedical Engineering DepartmentBandungIndonesia

    2 shared publications
  • Donny Danudirdjo

    Bandung Institute of Technology,Biomedical Engineering DepartmentBandungIndonesia

    2 shared publications

Latest Publications

  • Open Access

    Electrooculography signal as alternative method to operate wheelchair based on SVM classifier

    by Muhammad Ilhamdi Rusydi, Amimul Ummah Baiqi, Muhammad Arief Rahman, Adam Jordan, Hermawan Nugroho, Kojiro Matsushita, Syafii, Yuli Afmi Ropita Sari, Noverika Windasari, Agung Wahyu Setiawan, et al.

    People with impairment conditions have some difficulties with daily activities such as controlling a wheelchair. Biosignal is one of the promising methods as an People with impairment conditions have some difficulties with daily activities such as controlling a wheelchair. Biosignal is one of the promising methods as an


  • Implementation of Enhanced Hybrid Learning to Improve Students’ Engagement

    by Agung W. Setiawan

    The implementation of a new learning method, enhanced Hybrid Learning, is reported in this study. The aim of this study is to improve the learning outcomes, course implementation, and students’ experience in Biosignal Measurement and Instrumentation course using the enhanced Hybrid Learning. The proposed learning method is introduced in the 2018/2019 academic year that consists of a literature review, student presentation and discussion, and mini-project. This study will compare the implementation of hybrid learning and enhanced hybrid learning. The average score for learning outcomes in 2018/2019 is 3.18, an increase of 0.56 than in 2017/2018. The score for course implementation is also increased significantly, from 2.81 in 2017/2018 to 3.33 in 2018/2019. The learning methods questionnaire result reveals that the mini and final projects-based learning approach have the highest score (4.7 out of 6.0). The lecturer presentation has the lowest score (3.9 out of 6.0), whereas the student presentation and literature review have scores of 4.4 and 4.1 out of 6.0. This study revealed that the enhanced Hybrid Learning is very useful to improve the learning outcomes, course implementation, and students’ experience. Importantly, using the enhanced Hybrid Learning approach, not only increases student engagement but also all the students who have passed the course. Another finding of the study is that the students are more excited, enjoyable, and valuable when using the proposed learning approach. The result provides evidence for implementing a hybrid learning approach to improve learning outcomes.

  • Open Access

    Deteksi Dini Kanker Kulit menggunakan K-NN dan Convolutional Neural Network

    by Teresia R. Savera, Winsya H. Suryawan, Agung Wahyu Setiawan

    Kanker kulit adalah salah satu jenis kanker yang dapat menyebabkan kematian sehingga diperlukan sebuah aplikasi perangkat lunak yang dapat digunakan untuk membantu melakukan deteksi dini kanker kulit dengan mudah. Sehingga diharapkan deteksi dini kanker kulit dapat terdeteksi lebih cepat. Pada penelitian ini terdapat dua metode yang digunakan untuk melakukan deteksi dini kanker kulit yaitu deteksi dengan klasifikasi secara regresi dan artificial neural network dengan arsitektur convolutional neural network. Akurasi yang diperoleh dengan menggunakan klasifikasi secara regresi adalah sebesar 75%. Sementara, akurasi deteksi yang didapatkan dengan menggunakan convolutional neural network adalah sebesar 76%. Hasil yang diperoleh dari kedua metoda ini masih dapat ditingkatkan pada penelitian lanjutan, yaitu dengan cara melakukan prapengolahan pada set data citra yang digunakan. Sehingga set data yang digunakan memiliki tingkat pencahayaan, sudut (pengambilan), serta ukuran citra yang sama. Apabila tersedia sumber daya komputasi yang besar, akan dilakukan penambahan jumlah citra yang digunakan, baik itu sebagai set data latih maupun uji. AbstractSkin cancer is one type of cancer that can cause death for many people. Because of this, an application is needed to easily detect skin cancer early that the cancer can be handled with more quickly. In this study there were two methods used to detect skin cancer, namely detection by regression classification and detection by classifying using artificial neural networks with network convolutional architecture. Detection with regression classification gives an accuracy of 75%. While detection using convolutional neural networks gives an accuracy of 76%. These proposed early detection systems can be improved to increase the accuracy. For further development, several image processing techniques will be applied, such as contrast enhancement and color equalization. For future works, if there is more computational resource, more images can be used as dataset and implement the deep learning algorithm to improve the accuracy.


  • Open Access

    Pengembangan Sistem Penilaian Kematangan Tandan Buah Segar Kelapa Sawit menggunakan Citra 680 dan 750 NM

    by Agung Wahyu Setiawan, Alfie R. Ananda

    Salah satu permasalahan utama dalam industri kelapa sawit adalah proses sortasi Tandan Buah Segar (TBS) di pabrik kelapa sawit. Parameter yang digunakan dalam sortasi TBS adalah jumlah brondolan kelapa sawit. Pada saat ini, sortasi dilakukan oleh grader yang bersifat subyektif dan sering kali tidak konsisten. Hal ini terjadi karena keterbatasan penglihatan dan kemampuan manusia untuk mengolah informasi jumlah brondolan setiap TBS dalam waktu yang terbatas. Oleh karena itu, pada penelitian ini dikembangkan sistem penilaian kematangan TBS kelapa sawit berbasis spektroskopi dan nilai kontras citras. Sumber cahaya yang digunakan pada penelitian ini adalah lampu berjenis Light-emitting Diode (LED) dengan panjang gelombang 680 dan 750 nm. Akuisisi citra TBS dilakukan dengan menggunakan kamera DSLR yang telah dimodifikasi. sehingga diperoleh dua citra TBS pada panjang gelombang 680 dan 750 nm. Kemudian, dilakukan perhitungan nilai kontras kedua citra tersebut. Dalam penelitian ini, terdapat 24 TBS yang digunakan sebagai data latih, dengan komposisi 10 TBS matang dan 14 TBS mentah. Data uji yang digunakan berjumlah 77 TBS yang terdiri dari 38 matang dan 39 mentah. Pada penelitian ini, Support Vector Machine (SVM) digunakan sebagai metode klasifikasi. Akurasi data latih yang diperoleh adalah 66,67%. Sedangkan akurasi data uji dari sistem yang dikembangkan dalam penelitian ini adalah 57,14%. Hasil yang diperoleh ini masih perlu diperbaiki untuk meningkatkan akurasi sistem dengan cara menambah jumlah data, baik data latih maupun uji, serta menggunakan pembelajaran mesin. AbstractOne of the main problems in the palm oil industry is the grading of Fresh Fruit Bunches (FFB) in the palm oil mills. The parameter used for the process is the number of fruitlets detached from the bunch. Nowadays, the FFB grading is conducted by graders which is subjective and often inconsistent due to the limitation of human vision and ability to process information on the number of fruitlets detached per FFB in a very limited time. Therefore, this study developed a grading system to assess and estimate the FFB maturity based on spectroscopy and image contrast value. From the literature review, visible light and NIR spectrum in 680 and 780 nm can be used as light sources to detect the maturity level of FFB. DSLR camera is used to acquire the FFB image. Using this scheme, two FFB images in 680 and 750 nm are obtained. The next process is to calculate the image contrast. In this research, there are 24 FFB that are used as training data that consists of 10 ripe and 14 unripe. A total of 77 FFB are used as test data that consists of 38 ripe and 39 unripe. Support Vector Machine (SVM) is used in this research to classify the maturity level of FFB. The accuracy of the training dataset is 66.67%. Meanwhile, the accuracy of the test data is 57.14%. Future works will focus on enhancing accuracy of the system through increasing the number of training and testing data using machine learning.

  • Development of Low-cost Wearable Walking Pattern Recognition System using Inertial Sensors

    by Agung W. Setiawan, Alfie R. Ananda

    Regular walking has several benefits for improving treatment of many diseases and pains, and improving the health-related quality of life. The prevalence of walking abnormalities are precursors of falls and cause severe injuries in elderly. Thus, it becomes important to recognize the walking pattern. The aim this research is to develop a low-cost wearable walking pattern system using inertial sensors. The proposed system consists inertial sensors, multiplexer, microcontroller, and personal computer. The proposed walking pattern system can be used to detect the walking cycle in the sagittal and frontal axes. The developed system can also distinguish forward and backward movements. This study presents the preliminary prototype and result of the walking pattern system recognition using low-cost electronics components and module. Even though the development costs are kept low, USD 39.6, the proposed system still meet the specification that have been set.


  • Development of Low Cost Enzyme-Linked Immunosorbent Assay Plate Reader

    by Alfie Rizky Ananda, Donny Danudirdjo, Agung W. Setiawan, Tati Latifah R. Mengko

    Elisa (enzyme-linked immunosorbent assay) is a method commonly used for screening patient such as Hepatitis, HIV, Malaria, etc. There are three components needed for screening patient using Elisa, the component are blood sample from the patient, diagnostic kit for the specific disease and plate reader used to measure the reaction between the sample and the kit. While the diagnostic kit cost are affordable but the commercial plate reader are still expensive. This system consists of LED as its light source, silicone photodiode as its sensor, stepper motor coupled with rotating screw as linier actuator and microcontroller used to control the system. The system have been test in laboratory using a substance with known absorption index in 96 wellplate and then compare it with commercial plate reader. The result from the benchmark shown that the plate reader that been designed show average deviation of ± 0.368 Absorption index.


  • Open Access

    Classification of Palm Oil Fresh Fruit Bunch using Multiband Optical Sensors

    by Agung Wahyu Setiawan, Richard Mengko, Ayu Paranitha H. Putri, Donny Danudirdjo, Alfie Rizky Ananda

    This study investigated optical sensor system consist of sixteen light emitting diode (LED) in visible/near infrared region to detect palm oil fresh fruit bunch (FFB) quality. Practically, experience grader assessed FFB quality by its ripeness based on external features such as colour and number of detached fruitlets. However, different seed and plantation management resulting in FFB quality variation. Same external features not linearly correlate with FFB oil content that corresponding with industrial needs. The 660 nm LED is choosen to be used to estimate the oil content of FFB. Using linear discriminant analysis (LDA) with Mahalanobis distance, the accuracy of the systems is 79.8% and 88.2%. From 33 FFB oil content measurement, grader misclassified 4 out of 17 FFB as ripe FFB but with low oil content (=17.5%). Classifying model build from FFB from main plantation then tested to evaluate FFB from smallholder. Classification model generated from FFB oil content data showed more accurate result compared to model generated from visual inspection 66.7% compared to 52.1%. Model accuracies attained by Discriminant Analysis (DA) and k-Nearest Neighbors (k-NN) were 79.8% and 80.7%, respectively based on grader evaluation. Model accuracies based on FFB oil content was 88.2% for both classifying algorithms.


  • Advancement on Automatic Blood Pressure Measurement Using Auscultatory Method: A Literature Review

    by Dziban Naufal, Tati Latifah Erawati Rajab, Agung Wahyu Setiawan

    Auscultatory method as a gold standard in determining blood pressure is subjective due to its dependency on hearing ability of each person. This subjectivity could be eliminated by establishing an instrument that is able to determine blood pressure level automatically. One of the ideas that could be proposed for developing an automatic blood pressure monitor is to automatize auscultatory method. This review presented recent development of automatic blood pressure monitor by recording Korotkoff sound and processing it digitally to determine blood pressure level and phases of the sounds that believed was associated with physiological condition. The reviewed studies showed that by processing Korotkoff sounds, the measurement results were accurate if compared with conventional method since their correlation coefficient is greater than 0.95 and the errors that obtained are less than 5 mmHg. The future work of this review is to design a similar instrumentation with different signal processing methods, i.e. discrete wavelet transform and peak finder algorithm.


  • Development of an Integrated Laboratory Course Sequence on Biomedical Instrumentation and Signal Processing

    by Astri Handayani, Agung Wahyu Setiawan, Widyawardana Adiprawita

    This paper presents the development of an undergraduate laboratory course sequence on biomedical instrumentation and signal processing, designed to provide an integrated learning experience on the practical aspects of biomedical system design. The course sequence is aimed for the third-year students of the biomedical engineering undergraduate program and implemented as two consecutive laboratory courses taking place at sequential semesters. Each course consists of classical lectures on technical aspects of biomedical instrumentation or signal processing, followed by structured laboratory works which culminate into a complete functional system at the end of each semester. The respective case studies of the first and second half of the sequence are the development of an off-the-shelf analog electrocardiograph instrument and a simple digital signal processing module to measure heart rate from the electrocardiogram. The course sequence emphasizes on the translation of physiological concepts into analog and digital electronic systems as well as the appropriate design and prototyping considerations of such systems. It promotes integrative thinking and independent study by posing each module as a semi-open problem and omitting the traditional step-by-step instruction set. This course sequence serves as a firsthand exposure to a model biomedical system design cycle.


  • Open Access

    Development of non-occlusive blood pressure monitor with height correction for home used application

    by Agung W. Setiawan, Nur A. Heryanto, Fadel M. Putra, Febri Suyitno, M. Andre Martin, Yana S. Raharja

    Non-occlusive blood pressure measurement method is developed to avoid the use of discontinuous and uncomfortable cuff-based methods. In this research, Pulse Transit Time (PTT) and Photoplethysmogram Intensity Ratio (PIR) is used to measure blood pressure. Two photoplethysmogram (PPG) sensors that are placed on the wrist and one of the finger joints both on the left hand is used to get the PTT and PIR. The name of the device is ARTSEN. During measurement, there is a measurement error caused by the hydrostatic effect when the device position is not inline with the heart. To minimize this error, this research proposes an automatic continuous blood pressure monitor. The device will conduct measurement only when the height of the device is inline with the heart. Accelerometer and gyroscope are used to detect the height of the device. There are 30 subjects that are involved in this research. To evaluate the performance of the device, there are two measurement conditions, during lying in the bed and sit down position. The blood pressure measurement is conducted using ARTSEN and sphygmomanometer (as the gold standard of blood pressure measurement). The average error of systolic blood pressure is 8 mmHg with standard deviation 5 mmHg, and average error of diastolic blood pressure is 8 mmHg with standard deviation 4 mmHg.