Dexi Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dexi Zhu has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Meixiao Shen
School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
7 shared publicationsYuheng Zhou
School of Ophthalmology and Optometry Wenzhou Medical University Zhejiang China
6 shared publications- Fan Lu
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China
5 shared publications Shuling Ye
School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
5 shared publicationsChenhong Bao
School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
4 shared publicationsYingying Dai
Zhejiang Industry and Trade Vocational College, Wenzhou, China
3 shared publications
Latest Publications
- 7 July 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (8) , 3105-3115
Ultra-fast line-field swept source scanning optical coherence elastography
The drawbacks of repeated excitations and long imaging time in wave-based optical coherence elastography limited its application in ophthalmology. In this study, we put forward a swept source scanning optical coherence elastography (SSS-OCE) system based on the wavelength-dependence scanning technique. A dispersive element was employed to achieve ultra-fast line scanning from swept light source. Through a series of experiments on agar phantoms with varying concentrations, in situ porcine corneas under different intraocular pressures, and human eyes in vivo, we have demonstrated that SSS-OCE has the capability to rapidly evaluate the elasticity of ocular tissues in vivo with single excitation and offers the advantages of a simple structure and short measurement time.
- 7 July 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (8) , 3105-3115
Ultra-fast line-field swept source scanning optical coherence elastography
The drawbacks of repeated excitations and long imaging time in wave-based optical coherence elastography limited its application in ophthalmology. In this study, we put forward a swept source scanning optical coherence elastography (SSS-OCE) system based on the wavelength-dependence scanning technique. A dispersive element was employed to achieve ultra-fast line scanning from swept light source. Through a series of experiments on agar phantoms with varying concentrations, in situ porcine corneas under different intraocular pressures, and human eyes in vivo, we have demonstrated that SSS-OCE has the capability to rapidly evaluate the elasticity of ocular tissues in vivo with single excitation and offers the advantages of a simple structure and short measurement time.
- 15 April 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (5) , 1887-1898
Ultrafast line-field holographic elastography with single excitation for corneal biomechanical characterization
Elastography has become an essential tool for assessing tissue biomechanics, in particular for the diagnosis and treatment of keratoconus. For in vivo measurements, high-speed imaging and reduced stimulation are crucial. In this study, we introduce a line-field holographic elastography (LF-HE), which employs line-focus illumination and parallel acquisition to achieve ultra-fast measurement in 14 ms with single excitation. A novel data processing method combining the short time Fourier transform, the phase-resolved color Doppler and full width at half maximum algorithms is proposed to extract the local biomechanical property. Agar phantoms with various concentrations were measured to valid the LF-HE system. The changes of stiffness of in situ porcine corneas treated by riboflavin/UV-A collagen cross-linking (UV-CXL) were also detected in a lateral range of 4.4 mm by modifying the light path of sample arm. This research demonstrated the significant potential of LF-HE for application in ophthalmology clinics.
- 15 April 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (5) , 1887-1898
Ultrafast line-field holographic elastography with single excitation for corneal biomechanical characterization
Elastography has become an essential tool for assessing tissue biomechanics, in particular for the diagnosis and treatment of keratoconus. For in vivo measurements, high-speed imaging and reduced stimulation are crucial. In this study, we introduce a line-field holographic elastography (LF-HE), which employs line-focus illumination and parallel acquisition to achieve ultra-fast measurement in 14 ms with single excitation. A novel data processing method combining the short time Fourier transform, the phase-resolved color Doppler and full width at half maximum algorithms is proposed to extract the local biomechanical property. Agar phantoms with various concentrations were measured to valid the LF-HE system. The changes of stiffness of in situ porcine corneas treated by riboflavin/UV-A collagen cross-linking (UV-CXL) were also detected in a lateral range of 4.4 mm by modifying the light path of sample arm. This research demonstrated the significant potential of LF-HE for application in ophthalmology clinics.
- 10 April 2025
- Published by Wiley in Journal of Biophotonics
- p. e70027
Shear Wave Optical Coherence Elastography Imaging by Deep Learning
Quantifying ocular tissue mechanical properties is pivotal for elucidating eye disease etiology and progression. Optical coherence elastography (OCE), leveraging high‐resolution optical coherence tomography, promises tissue stiffness assessment. Traditional OCE relies on data processing of the time‐of‐flight method and encounters challenges like low repeatability. Our study presents an optimized data processing workflow integrating OCE with deep learning to predict ocular tissue biomechanical properties. The concentration prediction network (CPN), a 3D convolutional neural network, predicts sample's concentrations and calculates the Young's modulus based on the relationship between agar concentration and Young's modulus from mechanical testing. The CPN showed high accuracy, with a mean absolute error of 0.028 ± 0.036 for training and 0.036 ± 0.024 for testing data of agar phantoms. In situ porcine corneas with various intraocular pressures was measured, yielding corneal biomechanical distribution via deep learning method. This approach enhances the efficiency of OCE and underscores potential clinical applications in ophthalmology.
- 10 April 2025
- Published by Wiley in Journal of Biophotonics
- p. e70027
Shear Wave Optical Coherence Elastography Imaging by Deep Learning
Quantifying ocular tissue mechanical properties is pivotal for elucidating eye disease etiology and progression. Optical coherence elastography (OCE), leveraging high‐resolution optical coherence tomography, promises tissue stiffness assessment. Traditional OCE relies on data processing of the time‐of‐flight method and encounters challenges like low repeatability. Our study presents an optimized data processing workflow integrating OCE with deep learning to predict ocular tissue biomechanical properties. The concentration prediction network (CPN), a 3D convolutional neural network, predicts sample's concentrations and calculates the Young's modulus based on the relationship between agar concentration and Young's modulus from mechanical testing. The CPN showed high accuracy, with a mean absolute error of 0.028 ± 0.036 for training and 0.036 ± 0.024 for testing data of agar phantoms. In situ porcine corneas with various intraocular pressures was measured, yielding corneal biomechanical distribution via deep learning method. This approach enhances the efficiency of OCE and underscores potential clinical applications in ophthalmology.
- 29 November 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (12) , 6671-6681
In situ assessment of lens elasticity with noncontact optical coherence elastography
Lens biomechanics has great potential for application in clinical diagnostics and treatment monitoring of presbyopia and cataracts. However, current approaches to lens elastography do not meet the desired safety or sensitivity for clinical application. In this regard, we propose a noncontact optical coherence elastography (OCE) method to facilitate quantitative in situ imaging of lens elasticity. Elastic waves induced by air-pulse stimulation on the limbus propagate to the lens and are then imaged using custom-built swept-source optical coherence tomography to obtain the elastic wave velocity and Young’s modulus. The proposed OCE method was first validated by comparing the results of in situ and in vitro measurements of porcine lenses. The results demonstrate that the Young’s modulus measured in situ was highly consistent with that measured in vitro and had an intraclass correlation coefficient of 0.988. We further investigated the elastic changes induced by cold storage and microwave heating. During 36-hour cold storage, the mean Young’s modulus gradually increased (from 5.62 ± 1.24 kPa to 11.40 ± 2.68 kPa, P < 0.0001, n = 9) along with the formation of nuclear opacities. 15-second microwave heating caused a greater increase in the mean Young’s modulus (from 6.86 ± 1.21 kPa to 25.96 ± 8.64 kPa, P < 0.0025, n = 6) without apparent cataract formation. Accordingly, this study reports the first air-pulse OCE measurements of in situ lenses, which quantified the loss of lens elasticity during simulated cataract development with good repeatability and sensitivity, thus enhancing the potential for adoption of lens biomechanics in the clinic.
- 29 November 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (12) , 6671-6681
In situ assessment of lens elasticity with noncontact optical coherence elastography
Lens biomechanics has great potential for application in clinical diagnostics and treatment monitoring of presbyopia and cataracts. However, current approaches to lens elastography do not meet the desired safety or sensitivity for clinical application. In this regard, we propose a noncontact optical coherence elastography (OCE) method to facilitate quantitative in situ imaging of lens elasticity. Elastic waves induced by air-pulse stimulation on the limbus propagate to the lens and are then imaged using custom-built swept-source optical coherence tomography to obtain the elastic wave velocity and Young’s modulus. The proposed OCE method was first validated by comparing the results of in situ and in vitro measurements of porcine lenses. The results demonstrate that the Young’s modulus measured in situ was highly consistent with that measured in vitro and had an intraclass correlation coefficient of 0.988. We further investigated the elastic changes induced by cold storage and microwave heating. During 36-hour cold storage, the mean Young’s modulus gradually increased (from 5.62 ± 1.24 kPa to 11.40 ± 2.68 kPa, P < 0.0001, n = 9) along with the formation of nuclear opacities. 15-second microwave heating caused a greater increase in the mean Young’s modulus (from 6.86 ± 1.21 kPa to 25.96 ± 8.64 kPa, P < 0.0025, n = 6) without apparent cataract formation. Accordingly, this study reports the first air-pulse OCE measurements of in situ lenses, which quantified the loss of lens elasticity during simulated cataract development with good repeatability and sensitivity, thus enhancing the potential for adoption of lens biomechanics in the clinic.
- Open Access
- 1 April 2022
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 856531
Identification of Peripheral Anterior Synechia by Corneal Deformation Using Air-Puff Dynamic Anterior Segment Optical Coherence Tomography
Indentation gonioscopy is commonly used in the clinic to evaluate peripheral anterior synechia (PAS) of angle closure glaucoma (ACG). The examination requires contacting with the cornea, resulting in an uncomfortable feeling for patients, and it only provides qualitative outcomes which may be affected by subjective judgment of the clinicians. Previous studies had reported to identify the presence of PAS by measuring the changes of morphological parameters of the anterior chamber angle (ACA) under the pupillary light reflex, by anterior segment optical coherence tomography (AS-OCT). However, this method was invalid for some subjects who had low sensitiveness to light. This article describes an air-puff dynamic anterior segment optical coherence tomography (DAS-OCT) system that can evaluate the presence of PAS in a non-contact approach. The peripheral cornea is deformed by an air puff jetted from the DAS-OCT, causing a transfer of force to the ACA, just as how indentation gonioscopy works. The dynamic changes of the ACA before and after the air puff are recorded by OCT. Ten eyes of normal subjects were enrolled in this study to validate the repeatability and availability of the measurements. Then, ten samples of the ACA from five subjects with ACG were recruited and were assigned into two groups, the non PAS group (NPAS) and PAS group, according to the results of gonioscopy. The ACA structural parameters including the angle opening distance at 750 μm to the scleral spur (AOD750) and the trabecular-iris space area at 750 μm anterior to the scleral spur (TISA750) were then calculated automatically by a custom-written algorithm. The intraclass correlation coefficient (ICC) of measured parameters was all above 0.85 for normal subjects, exhibiting good repeatability. For patients, both parameters showed significant differences between the two groups after the air puff, while no differences were observed before the air puff. AOD750dif and TISA750dif between two groups showed more significant differences, indicating that they could be used as indicators to identify the presence of PAS. In conclusion, the DAS-OCT system proposed in this study is demonstrated effective to identify the presence of PAS by measuring the changes of the ACA via a noncontact approach. It shows great potential for applications in guidance for diagnosis of angle closure glaucoma.
- 1 April 2022
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 856531
Open AccessIdentification of Peripheral Anterior Synechia by Corneal Deformation Using Air-Puff Dynamic Anterior Segment Optical Coherence Tomography
Indentation gonioscopy is commonly used in the clinic to evaluate peripheral anterior synechia (PAS) of angle closure glaucoma (ACG). The examination requires contacting with the cornea, resulting in an uncomfortable feeling for patients, and it only provides qualitative outcomes which may be affected by subjective judgment of the clinicians. Previous studies had reported to identify the presence of PAS by measuring the changes of morphological parameters of the anterior chamber angle (ACA) under the pupillary light reflex, by anterior segment optical coherence tomography (AS-OCT). However, this method was invalid for some subjects who had low sensitiveness to light. This article describes an air-puff dynamic anterior segment optical coherence tomography (DAS-OCT) system that can evaluate the presence of PAS in a non-contact approach. The peripheral cornea is deformed by an air puff jetted from the DAS-OCT, causing a transfer of force to the ACA, just as how indentation gonioscopy works. The dynamic changes of the ACA before and after the air puff are recorded by OCT. Ten eyes of normal subjects were enrolled in this study to validate the repeatability and availability of the measurements. Then, ten samples of the ACA from five subjects with ACG were recruited and were assigned into two groups, the non PAS group (NPAS) and PAS group, according to the results of gonioscopy. The ACA structural parameters including the angle opening distance at 750 μm to the scleral spur (AOD750) and the trabecular-iris space area at 750 μm anterior to the scleral spur (TISA750) were then calculated automatically by a custom-written algorithm. The intraclass correlation coefficient (ICC) of measured parameters was all above 0.85 for normal subjects, exhibiting good repeatability. For patients, both parameters showed significant differences between the two groups after the air puff, while no differences were observed before the air puff. AOD750dif and TISA750dif between two groups showed more significant differences, indicating that they could be used as indicators to identify the presence of PAS. In conclusion, the DAS-OCT system proposed in this study is demonstrated effective to identify the presence of PAS by measuring the changes of the ACA via a noncontact approach. It shows great potential for applications in guidance for diagnosis of angle closure glaucoma.
- 29 May 2021
- Published by Wiley in Journal of Biophotonics
- Vol. 14 (9) , e202100116
In vivo non‐contact measurement of human iris elasticity by optical coherence elastography
Quantifying the mechanical properties of the iris can offer valuable insights into the pathophysiology of primary angle closure glaucoma. However, current techniques for iris elastography remain ex vivo with limited clinical applications. This article describes a proposition for a non‐contact and non‐invasive air‐puff optical coherence elastography (OCE) system that can evaluate iris elasticity in vivo. Ten eyes recruited from seven subjects underwent OCE imaging acquisition under three different illumination conditions. The Young's modulus of each eye was detected and shown to be inversely proportional to the iris length, indicating a relationship between mechanical properties and morphology of the iris. With its noninvasive and high‐resolution features, this air‐puff system shows great potential for applications in clinical ophthalmology.
- 29 May 2021
- Published by Wiley in Journal of Biophotonics
- Vol. 14 (9) , e202100116
In vivo non‐contact measurement of human iris elasticity by optical coherence elastography
Quantifying the mechanical properties of the iris can offer valuable insights into the pathophysiology of primary angle closure glaucoma. However, current techniques for iris elastography remain ex vivo with limited clinical applications. This article describes a proposition for a non‐contact and non‐invasive air‐puff optical coherence elastography (OCE) system that can evaluate iris elasticity in vivo. Ten eyes recruited from seven subjects underwent OCE imaging acquisition under three different illumination conditions. The Young's modulus of each eye was detected and shown to be inversely proportional to the iris length, indicating a relationship between mechanical properties and morphology of the iris. With its noninvasive and high‐resolution features, this air‐puff system shows great potential for applications in clinical ophthalmology.
- 11 May 2021
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 259 (9) , 2753-2759
Identification of peripheral anterior synechia with anterior segment optical coherence tomography
Purpose To generate a model that evaluates the presence and extent of peripheral anterior synechia (PAS) based on anterior segment optical coherence tomography (AS-OCT). Methods The extent of PAS involvement in the eyes of patients with angle closure was assessed by indentation gonioscopy, and the part of non-PAS and PAS were assigned into two groups (NPAS and PAS). Anterior chamber angles were then imaged by AS-OCT with light-emitting diode (LED) irradiation directly into the pupils, leading to pupillary constriction and increasing anterior chamber angle width. Parameters including the angle opening distance at 750 μm anterior to the scleral spur (AOD750) and trabecular-iris space area at 750 μm anterior to the scleral spur (TISA750) were then obtained. The differences before and after LED irradiation of AOD750 and TISA750 were calculated and used to generate a PAS model based on binary logistic regression. Validation data were then tested. Results A total of 258 AS-OCT images in 14 eyes were assigned to the modeling data, and 120 were assigned to the validation data. There were no differences in AOD750 and TISA750 in the dark between NPAS and PAS (PAOD750 = 0.258, PTISA750 = 0.486), whereas after LED light exposure, TISA750light was larger in NPAS than in PAS (P = 0.047). The light–dark differences of both parameters showed significant differences between the two groups (PAOD750dif = 0.019, PTISA750dif < 0.001). The area under the curve of the model performance was 0.841, and the overall correct rate was 80.8% based on the validation data. Conclusions The present study demonstrates that the AS-OCT-based PAS model could be useful in the identifying of the presence of synechial angle closure and evaluating the extent of PAS in a single eye.
- 11 May 2021
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 259 (9) , 2753-2759
Identification of peripheral anterior synechia with anterior segment optical coherence tomography
Purpose To generate a model that evaluates the presence and extent of peripheral anterior synechia (PAS) based on anterior segment optical coherence tomography (AS-OCT). Methods The extent of PAS involvement in the eyes of patients with angle closure was assessed by indentation gonioscopy, and the part of non-PAS and PAS were assigned into two groups (NPAS and PAS). Anterior chamber angles were then imaged by AS-OCT with light-emitting diode (LED) irradiation directly into the pupils, leading to pupillary constriction and increasing anterior chamber angle width. Parameters including the angle opening distance at 750 μm anterior to the scleral spur (AOD750) and trabecular-iris space area at 750 μm anterior to the scleral spur (TISA750) were then obtained. The differences before and after LED irradiation of AOD750 and TISA750 were calculated and used to generate a PAS model based on binary logistic regression. Validation data were then tested. Results A total of 258 AS-OCT images in 14 eyes were assigned to the modeling data, and 120 were assigned to the validation data. There were no differences in AOD750 and TISA750 in the dark between NPAS and PAS (PAOD750 = 0.258, PTISA750 = 0.486), whereas after LED light exposure, TISA750light was larger in NPAS than in PAS (P = 0.047). The light–dark differences of both parameters showed significant differences between the two groups (PAOD750dif = 0.019, PTISA750dif < 0.001). The area under the curve of the model performance was 0.841, and the overall correct rate was 80.8% based on the validation data. Conclusions The present study demonstrates that the AS-OCT-based PAS model could be useful in the identifying of the presence of synechial angle closure and evaluating the extent of PAS in a single eye.
- Open Access
- 2 June 2020
- Published by Springer Nature in Eye and Vision
- Vol. 7 (1) , 1-10
Modeling of gonioscopic anterior chamber angle grades based on anterior segment optical coherence tomography
Background: To quantitatively assess anterior chamber angle (ACA) structure by anterior segment optical coherence tomography (AS-OCT) and develop a model to evaluate angle width as defined by gonioscopy.Methods: The ACAs of each quadrant were evaluated by gonioscopy, classified by the Scheie grading system, and assigned into one of the three grades: small angle (SA), moderate angle (MA), and large angle (LA). The eyes were imaged by AS-OCT, and ACA structural parameters including angle opening distance at the scleral spur (AODSS) and at 750 μm anterior to the scleral spur (AOD750), trabecular-iris space area at 750 μm anterior to the scleral spur (TISA750), and a newly defined parameter “light intersection distance” (LID), were measured. The ACA structural data were used to construct an ordered logistic regression model for assignment of ACAs to one of the three angle grades. The validity of the model was then tested.Results: A total of 169 quadrants from 53 subjects were included in the analysis, of which 111 quadrants were included in the modeling data and 58 in the testing data. In pairwise comparisons of SA, MA, and LA by ANOVA, the measured parameters were as follows: AOD750 (0.174 ± 0.060 vs. 0.249 ± 0.068 vs. 0.376 ± 0.114 mm;P < 0.001), TISA750 (0.075 ± 0.035 vs. 0.117 ± 0.036 vs. 0.181 ± 0.062 mm2;P < 0.001), and LID (− 0.300 ± 0.187 vs. -0.085 ± 0.170 vs. 0.122 ± 0.156 mm;P < 0.001). The ACA grading model based on LID showed a relatively high correction rate of 72.4%, and the model efficiency, calculated using the receiver operating characteristic, showed an area under the curve of 0.740. Weighted kappa statistics showed a good agreement for multiple ACA grades (0.772).Conclusions: The AS-OCT-based multiple ACA grades model was demonstrated as a non-contact approach for ACA assessment with high speed and high spatial resolution, providing guidance for diagnosis of angle closure.
- 2 June 2020
- Published by Springer Nature in Eye and Vision
- Vol. 7 (1) , 1-10
Open AccessModeling of gonioscopic anterior chamber angle grades based on anterior segment optical coherence tomography
Background: To quantitatively assess anterior chamber angle (ACA) structure by anterior segment optical coherence tomography (AS-OCT) and develop a model to evaluate angle width as defined by gonioscopy.Methods: The ACAs of each quadrant were evaluated by gonioscopy, classified by the Scheie grading system, and assigned into one of the three grades: small angle (SA), moderate angle (MA), and large angle (LA). The eyes were imaged by AS-OCT, and ACA structural parameters including angle opening distance at the scleral spur (AODSS) and at 750 μm anterior to the scleral spur (AOD750), trabecular-iris space area at 750 μm anterior to the scleral spur (TISA750), and a newly defined parameter “light intersection distance” (LID), were measured. The ACA structural data were used to construct an ordered logistic regression model for assignment of ACAs to one of the three angle grades. The validity of the model was then tested.Results: A total of 169 quadrants from 53 subjects were included in the analysis, of which 111 quadrants were included in the modeling data and 58 in the testing data. In pairwise comparisons of SA, MA, and LA by ANOVA, the measured parameters were as follows: AOD750 (0.174 ± 0.060 vs. 0.249 ± 0.068 vs. 0.376 ± 0.114 mm;P < 0.001), TISA750 (0.075 ± 0.035 vs. 0.117 ± 0.036 vs. 0.181 ± 0.062 mm2;P < 0.001), and LID (− 0.300 ± 0.187 vs. -0.085 ± 0.170 vs. 0.122 ± 0.156 mm;P < 0.001). The ACA grading model based on LID showed a relatively high correction rate of 72.4%, and the model efficiency, calculated using the receiver operating characteristic, showed an area under the curve of 0.740. Weighted kappa statistics showed a good agreement for multiple ACA grades (0.772).Conclusions: The AS-OCT-based multiple ACA grades model was demonstrated as a non-contact approach for ACA assessment with high speed and high spatial resolution, providing guidance for diagnosis of angle closure.