BMBozhi Ma

Bozhi Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bozhi Ma has a total of 61 co-authors. Here are the top co-authors by number of shared publications:

  • Boyang Zhang

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China

    2 shared publications
  • Luming Li

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University; IDG/McGovern Institute for Brain Research, Tsinghua University

    2 shared publications
  • Xi Zhang

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China

    2 shared publications
  • Xuesong Luo

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China

    2 shared publications
  • Anchao Yang

    1 shared publication
  • Changqing Jiang

    National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, China

    1 shared publication

Latest Publications

  • Open Access

    Real-world clinical and economic evaluation of remote programming for deep brain stimulation in Parkinson’s disease

    by Yang Lu, Yida Sun, Huiling Yu, Bozhi Ma, Chunhua Hu, Weiming Wang, Changqing Jiang, Xiaodong Cai, Zhiqiang Cui, Liang Chen, et al.

    Deep brain stimulation (DBS) is an established therapy for Parkinson’s disease, yet conventional onsite programming mandates frequent travel to specialized centres, imposing substantial burdens on patients. Here we present a large real-world analysis of remote programming (RP) for DBS in China, drawing on 20,383 patients with Parkinson’s disease and 42,163 RP sessions (2012–2024). RP achieves comparable satisfaction and effectiveness to onsite programming while reducing the healthcare access inequality index by 30%. These access gains translate into disproportionate economic benefits for the most vulnerable groups, with cost savings two to ten times greater among low-income, remote and advanced-disease populations. Integrated clinical–labour–economy modelling projects annual direct economic benefits of ¥1.09 billion from reduced domestic medical tourism and ¥8.15 billion from labour-cost savings, with cumulative benefits of ¥115–270 billion by 2050 (3.9–9.2% of China’s 2024 basic medical insurance fund). These findings suggest that RP could be a clinically equivalent, more equitable and economically advantageous approach for postoperative DBS management worldwide.


  • Open Access

    Predict neuromuscular performance in human epidural electrical stimulation: phase 1 trial interim results

    by Hongda Li, Yunyue Wei, Yanan Sui, Xi Zhang, Xuesong Luo, Boyang Zhang, Bozhi Ma

    Epidural electrical stimulation (EES) has emerged as a promising therapy for restoring motor function in patients with paralysis. A primary challenge in this therapy lies in identifying feasible stimulation parameters in huge selection space for different movements, given the limited understanding of the precise alignment between stimulation and corresponding neuromuscular performance. We aimed to develop a computational framework that predicts neuromuscular performance under EES and thereby reduces the need for extensive in-clinic parameter searches. We implanted purpose-designed 32-contact epidural interfaces in two individuals with motor-complete spinal cord injury and reconstructed personalized spinal anatomies from medical imaging. Finite element simulations and axonal recruitment modeling were integrated with machine learning to establish a predictive mapping between stimulation parameters and muscle responses. A dimensionality-reduction Bayesian optimization algorithm was subsequently applied to identify compact sets of stimulation parameters targeting specific motor objectives, and selected configurations were validated through clinical testing. This study is an interim report of an ongoing registered clinical trial (Closed-loop Functional Spinal Cord Stimulation in Patients with Spinal Cord Injury, ClinicalTrials.gov Identifier: NCT04969042), sponsored by Beijing PINS Medical Co., Ltd. Here we present purpose-designed 32-contact epidural neural interfaces that enabled two individuals with spinal cord injury to regain lower-limb motor function. The hybrid predictive model demonstrated strong quantitative agreement with experimentally measured muscle responses (mean squared error = 0.0096). Algorithm-guided parameter recommendations comprising 180 configurations outperformed both the historical dataset (1,602 configurations) and conventional bipolar settings across four functional objectives. Clinical validation further confirmed that the recorded muscle activations were in close agreement with model predictions. The AI-aided computational framework can serve as a reliable and feasible agent for evaluating and recommending effective EES parameters. By bridging anatomical modeling with functional outcomes, this approach offers a practical pathway toward optimizing neuromodulation therapies and advancing the development of personalized treatment strategies for individuals with spinal cord injury.

  • Open Access

    Biphasic Electrostimulation Artifact Model for ECAP Extraction in Spinal Cord Stimulation

    by Haochen Zhang, Xuesong Luo, Bozhi Ma, Luming Li, Xulan Yin, Zhongwei Luo, Boyang Zhang, Xi Zhang, Hongda Li, Qingyu Yao, et al.

    Evoked compound action potential (ECAP) is extensively used as biomarker for neural activity in closed-loop spinal cord stimulation (SCS). However, accurate monitoring of neural activity is challenged by the low signal-to-noise ratio of ECAP recording, primarily due to the interference from stimulation-induced artifacts. This study proposes biphasic electrostimulation artifact model (BEAM) for ECAP extraction and assesses its efficacy using an enhanced quantification approach. The BEAM model is built based on the principle of additivity and incorporates boundary conditions that account for the equivalent electrical environment and temporal relationships. A bilinear growth curve model is introduced to calculate the E-score, enabling a comparison of ECAP extraction results with other methods. The proposed approach is extensively validated using clinical data from nine-month SCS therapy. BEAM method achieves the highest E-scores and reduces stimulation artifacts clinically without distorting information related to neural activity. BEAM accurately characterizes the morphology of artifacts generated by stimulation across various neurostimulation scenarios. Our model may lead to unique interpretation of neural activation in ECAP signals, evoked by electrical stimulation especially in closed-loop controlling strategies that aim to maintain consistent neural excitation.

  • Design and System Verification of Reconfigurable Matching Circuits for Implantable Antennas in Tissues With Broad Permittivity Range

    by Yuan Feng, Yue Li, Linze Li, Bozhi Ma, Hongwei Hao, Luming Li

    In this communication, we present an effective solution of reconfigurable matching circuits for tuning MICS band implantable antennas in various tissues. We use only two lumped components, a shunt inductor, and a series varactor with bias in the proposed circuits to match a spiral antenna on the neurostimulator platforms. By properly tuning the bias voltage of varactor, impedance matching of the same antenna is achieved in different tissues with a broad relative permittivity range from 5 to 60, which indicates superior antenna performance in the dramatically changeable biological environments. With the merits of simple configuration and easy voltage programming, the proposed circuits are accurately designed on impedance trace of the Smith Charts. In clinical applications, we integrate the reconfigurable matching circuit with the neurostimulator platform. The proposed circuits with implantable antenna are numerically analyzed and experimentally validated on the system-level. We achieve well antenna impedance matching performance in various types of tissues, i.e., reflection coefficients are less than -20 dB. And 6-12 dB benefit of link budget is achieved in different tissues.