Bruno Pagnin Schmid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bruno Pagnin Schmid has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Rodrigo Gobbo Garcia
Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
8 shared publications - Breno Boueri Affonso
Center of Interventional Medicine, Hospital Israelita Albert Einstein, São Paulo, (SP), Brazil
6 shared publications Felipe Nasser
Department of Interventional Radiology, Hospital Israelita Albert Einstein, Albert Einstein Avenue, 627, Sao Paulo, (SP), Brazil 05652-900
6 shared publications- Marcela Juliano Silva Cunha
Hospital Israelita Albert Einstein, Brasil
6 shared publications - Priscila Mina Falsarella
Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
6 shared publications - Francisco Leonardo Galastri
Center of Interventional Medicine, Hospital Israelita Albert Einstein, São Paulo, (SP), Brazil
5 shared publications
Latest Publications
- Open Access
- 19 June 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (9) , 108915
Early Outcomes of Transarterial Embolization of Uterine Arteriovenous Fistulae
- 19 June 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (9) , 108915
Open AccessEarly Outcomes of Transarterial Embolization of Uterine Arteriovenous Fistulae
- Open Access
- 26 October 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (5) , 2387-2396
Bifurcated In-Stent in Situ Technique for Creation of a Bifurcated Bridging Stent-Graft System to 2 Target Vessels Using a Single Directional Branch: A Report of 2 Cases
Objective: The objective of the study is to describe a novel bifurcated in-stent in situ technique (BIS2T) for creation of a bifurcated bridging stent-graft system to target 2 vessels using a single directional branch during complex endovascular aortic aneurysm. Technique: The technique uses 3 balloon-expandable stent-grafts. The first supporting stent-graft is deployed from the directional branch into the first target vessel or aneurysm sac. A reentry catheter is used to create an in situ fenestration in the first stent-graft, which is predilatated with a 3 mm 0.014 inch angioplasty balloon. This is exchanged for a 0.035 inch 5 Fr catheter and guidewire which is used for catheterization of the second target vessel via the in situ fenestration. The docking area of the first stent-graft is predilated. The second stent-graft is deployed into the second target with >1 cm overlap into the first stent-graft, followed by a matching third stent-graft in a kissing stent fashion to reinforce the bifurcation and achieve a “D shape” stent-graft configuration. Results: The BIS2T was used to treat 2 patients. Neither experienced complications or endoleaks, and both had patent branches on follow-up computed tomography angiography. Conclusions: The BIS2T is a feasible option to incorporate 2 target vessels via a single directional branch. Clinical Impact: Target vessel anatomy is a frequent limitation for successful endovascular incorporation using fenestrations or directional branches during complex endovascular aortic aneurysm repair. Numerous anatomical variations such as aberrant or accessory vessels, common celio-mesenteric trunks, or extension of the aneurysm/dissection into a target vessel may preclude successful incorporation using standard endovascular techniques. This technical note describes a novel bifurcated in-stent in situ technique (BIS2T) for the creation of a bifurcated bridging stent-graft system to target 2 vessels using a single directional branch. This approach may enable target vessel incorporation in challenging anatomical situations that might otherwise preclude endovascular treatment or require intentional artery coverage.
- 26 October 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 33 (5) , 2387-2396
Open AccessBifurcated In-Stent in Situ Technique for Creation of a Bifurcated Bridging Stent-Graft System to 2 Target Vessels Using a Single Directional Branch: A Report of 2 Cases
Objective: The objective of the study is to describe a novel bifurcated in-stent in situ technique (BIS2T) for creation of a bifurcated bridging stent-graft system to target 2 vessels using a single directional branch during complex endovascular aortic aneurysm. Technique: The technique uses 3 balloon-expandable stent-grafts. The first supporting stent-graft is deployed from the directional branch into the first target vessel or aneurysm sac. A reentry catheter is used to create an in situ fenestration in the first stent-graft, which is predilatated with a 3 mm 0.014 inch angioplasty balloon. This is exchanged for a 0.035 inch 5 Fr catheter and guidewire which is used for catheterization of the second target vessel via the in situ fenestration. The docking area of the first stent-graft is predilated. The second stent-graft is deployed into the second target with >1 cm overlap into the first stent-graft, followed by a matching third stent-graft in a kissing stent fashion to reinforce the bifurcation and achieve a “D shape” stent-graft configuration. Results: The BIS2T was used to treat 2 patients. Neither experienced complications or endoleaks, and both had patent branches on follow-up computed tomography angiography. Conclusions: The BIS2T is a feasible option to incorporate 2 target vessels via a single directional branch. Clinical Impact: Target vessel anatomy is a frequent limitation for successful endovascular incorporation using fenestrations or directional branches during complex endovascular aortic aneurysm repair. Numerous anatomical variations such as aberrant or accessory vessels, common celio-mesenteric trunks, or extension of the aneurysm/dissection into a target vessel may preclude successful incorporation using standard endovascular techniques. This technical note describes a novel bifurcated in-stent in situ technique (BIS2T) for the creation of a bifurcated bridging stent-graft system to target 2 vessels using a single directional branch. This approach may enable target vessel incorporation in challenging anatomical situations that might otherwise preclude endovascular treatment or require intentional artery coverage.
- Open Access
- 11 October 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (1)
Early and late outcomes of patient-specific endografts with retrograde outer branches for complex aortic aneurysms involving cranially oriented target vessels
- 11 October 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 12 (1)
Open AccessEarly and late outcomes of patient-specific endografts with retrograde outer branches for complex aortic aneurysms involving cranially oriented target vessels
- Open Access
- 6 August 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (6) , 101947
Technical pitfalls and initial clinical experience using femoral staggered multibranch thoracoabdominal aneurysm repair technique
- 6 August 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (6) , 101947
Open AccessTechnical pitfalls and initial clinical experience using femoral staggered multibranch thoracoabdominal aneurysm repair technique
- Open Access
- 22 April 2025
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 23, eAO1287
Dose-response relationships in Y90 resin microsphere radioembolization for patients with hepatocellular carcinoma: insights from a Brazilian cohort
Highlights ■ Higher absorbed doses are associated with positive tumor responses in patients with hepatocellular carcinoma treated with Y-90 radioembolization. ■ Personalized dosimetry may improve treatment outcomes in selected patients. ■ Dosimetric parameters such as D30, D50, and D70 also correlate positively with objective responses, emphasizing the importance of precise dose calculation in treatment planning. ABSTRACT Objective: To evaluate the relationship between the absorbed dose and radiological response in patients with hepatocellular carcinoma undergoing resin microsphere radioembolization to enhance treatment
- 22 April 2025
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 23, eAO1287
Open AccessDose-response relationships in Y90 resin microsphere radioembolization for patients with hepatocellular carcinoma: insights from a Brazilian cohort
Highlights ■ Higher absorbed doses are associated with positive tumor responses in patients with hepatocellular carcinoma treated with Y-90 radioembolization. ■ Personalized dosimetry may improve treatment outcomes in selected patients. ■ Dosimetric parameters such as D30, D50, and D70 also correlate positively with objective responses, emphasizing the importance of precise dose calculation in treatment planning. ABSTRACT Objective: To evaluate the relationship between the absorbed dose and radiological response in patients with hepatocellular carcinoma undergoing resin microsphere radioembolization to enhance treatment
- 24 December 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (4) , 721-723.e2
Continuous Intra-Arterial Infusion Chemotherapy Using a Port Catheter for Nasopharyngeal Carcinoma
- 24 December 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (4) , 721-723.e2
Continuous Intra-Arterial Infusion Chemotherapy Using a Port Catheter for Nasopharyngeal Carcinoma
- Open Access
- 31 October 2024
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 22, eRC0779
Irreversible electroporation for prostate cancer: another promising focal therapy
Radical treatment for prostate cancer is associated with significant morbidity. Percutaneous image-guided irreversible electroporation is a non-thermal ablative technique that has emerged as a valuable option. This study describes the case of a patient with prostate cancer who was successfully treated using irreversible electroporation. We report the case of a 72-year-old male patient who presented with elevated PSA (4.0ng/mL) during routine testing. Multiparametric magnetic resonance imaging of the prostate revealed a 0.8 cm lesion in the posterolateral aspect of
- 31 October 2024
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 22, eRC0779
Open AccessIrreversible electroporation for prostate cancer: another promising focal therapy
Radical treatment for prostate cancer is associated with significant morbidity. Percutaneous image-guided irreversible electroporation is a non-thermal ablative technique that has emerged as a valuable option. This study describes the case of a patient with prostate cancer who was successfully treated using irreversible electroporation. We report the case of a 72-year-old male patient who presented with elevated PSA (4.0ng/mL) during routine testing. Multiparametric magnetic resonance imaging of the prostate revealed a 0.8 cm lesion in the posterolateral aspect of
- Open Access
- 25 September 2024
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 22, eGS0683
Cost-effectiveness of radiofrequency ablation versus percutaneous ethanol injection for early hepatocellular carcinoma in a resource-poor setting: a randomized trial
In Brief Mariotti et al. demonstrated that radiofrequency ablation is more cost-effective, achieves a higher complete response rate, and has a lower complication rate than percutaneous ethanol injection in patients with early-stage hepatocellular carcinoma. Highlights Radiofrequency ablation and percutaneous ethanol injection are neoadjuvant hepatocellular carcinoma treatment methods. Radiofrequency ablation achieves a higher complete response rate (96.3% versus 60.0%, p=0.001). Total cost analyses showed radiofrequency ablation as a more expensive method (p<0.001). The incremental cost-effectiveness ratio was US$ -2674.59 with
- 25 September 2024
- Published by Sociedade Beneficente Israelita Brasileira Hospital Albert Einstein in Einstein (São Paulo)
- Vol. 22, eGS0683
Open AccessCost-effectiveness of radiofrequency ablation versus percutaneous ethanol injection for early hepatocellular carcinoma in a resource-poor setting: a randomized trial
In Brief Mariotti et al. demonstrated that radiofrequency ablation is more cost-effective, achieves a higher complete response rate, and has a lower complication rate than percutaneous ethanol injection in patients with early-stage hepatocellular carcinoma. Highlights Radiofrequency ablation and percutaneous ethanol injection are neoadjuvant hepatocellular carcinoma treatment methods. Radiofrequency ablation achieves a higher complete response rate (96.3% versus 60.0%, p=0.001). Total cost analyses showed radiofrequency ablation as a more expensive method (p<0.001). The incremental cost-effectiveness ratio was US$ -2674.59 with
- 10 September 2024
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 59 (2) , 170-175
Pulmonary Artery Endograft Implantation Using a Parallel Stent Grafting Technique to Enable the Treatment of a Bronchial Anastomosis Complication After Lung Transplantation
Background: Bronchial stenosis associated with bronchial anastomosis dehiscence after lung transplantation is a catastrophic complication following lung transplantation with a paucity of therapeutic solutions. Purpose: To describe an adaptation of the parallel stent grafting technique in the pulmonary arterial territory to treat this challenging situation. Research Design: This is a case report of a 52-year-old patient who presented bronchus stenosis and bronchial anastomosis dehiscence after lung transplantion. Bronchial stenting and lung retransplantation were contraindicated. Therefore, an endovascular approach using pulmonary artery endograft placement to prevent bleeding during repeated right bronchial balloon dilation was propposed. The technique consists of the deployment of an aortic extender endoprosthesis in the right main pulmonary artery and a balloon expandable stent in the upper lobe pulmonary artery (using a parallel graft configuration) through the common femoral and right internal jugular veins, respectively. Intraoperative transesophageal echocardiogram and one-lung ventilatory ventilation are needed. Results: The patient underwent a new bronchoscopy 16 days after the procedure, that showed epithelization at the previous eroded zone, enabling bronchocopic balloon dialtion to be safely performed. A post-operative contrast-enhanced CT scan revealed an adequate positioning of the stent grafts. Despite all eforts, the patient succumbed to ventilator associated pneumonia on postoperative day 108. Data Analysis: The technique's advantages include its feasibility even in situations in which other techniques may be contraindicated and its potential use in emergencies. Its limitations include the need for experienced interventionists to perform it, and the potential risk of acute tricuspid regurgitation. Conclusion: This study illustrates the early feasibility of the parallel stent grafting technique applied to the pulmonary artery territory. However, it's safety profile regarding infectious risk was not demontrated.
- 10 September 2024
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 59 (2) , 170-175
Pulmonary Artery Endograft Implantation Using a Parallel Stent Grafting Technique to Enable the Treatment of a Bronchial Anastomosis Complication After Lung Transplantation
Background: Bronchial stenosis associated with bronchial anastomosis dehiscence after lung transplantation is a catastrophic complication following lung transplantation with a paucity of therapeutic solutions. Purpose: To describe an adaptation of the parallel stent grafting technique in the pulmonary arterial territory to treat this challenging situation. Research Design: This is a case report of a 52-year-old patient who presented bronchus stenosis and bronchial anastomosis dehiscence after lung transplantion. Bronchial stenting and lung retransplantation were contraindicated. Therefore, an endovascular approach using pulmonary artery endograft placement to prevent bleeding during repeated right bronchial balloon dilation was propposed. The technique consists of the deployment of an aortic extender endoprosthesis in the right main pulmonary artery and a balloon expandable stent in the upper lobe pulmonary artery (using a parallel graft configuration) through the common femoral and right internal jugular veins, respectively. Intraoperative transesophageal echocardiogram and one-lung ventilatory ventilation are needed. Results: The patient underwent a new bronchoscopy 16 days after the procedure, that showed epithelization at the previous eroded zone, enabling bronchocopic balloon dialtion to be safely performed. A post-operative contrast-enhanced CT scan revealed an adequate positioning of the stent grafts. Despite all eforts, the patient succumbed to ventilator associated pneumonia on postoperative day 108. Data Analysis: The technique's advantages include its feasibility even in situations in which other techniques may be contraindicated and its potential use in emergencies. Its limitations include the need for experienced interventionists to perform it, and the potential risk of acute tricuspid regurgitation. Conclusion: This study illustrates the early feasibility of the parallel stent grafting technique applied to the pulmonary artery territory. However, it's safety profile regarding infectious risk was not demontrated.
- 18 June 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (8) , 1127-1133
Robotic-Assisted Endovascular Treatment for Transplant Renal Artery Stenosis: A Feasibility Study
Purpose To describe a single-center experience with robotic-assisted endovascular treatment for transplant renal artery stenosis. Materials and Methods This is a single-center, retrospective, feasibility study of 4 consecutive cases of robotic-assisted endovascular surgery for transplant renal artery stenosis from October 2021 to August 2022. Results All lesions were identified, and stenting was performed with no complications. Conversion to manual control was not necessary. The mean fluoroscopy time was 25.25 min (range 12–60.9). A control Doppler ultrasound was routinely performed, demonstrating no residual lesions in all cases. There was no reintervention during the follow-up period. The operator learning curve was felt to be acceptable. Conclusion Robotic-assisted endovascular treatment is a feasible technique for transplant renal artery stenosis. Graphical Abstract
- 18 June 2024
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (8) , 1127-1133
Robotic-Assisted Endovascular Treatment for Transplant Renal Artery Stenosis: A Feasibility Study
Purpose To describe a single-center experience with robotic-assisted endovascular treatment for transplant renal artery stenosis. Materials and Methods This is a single-center, retrospective, feasibility study of 4 consecutive cases of robotic-assisted endovascular surgery for transplant renal artery stenosis from October 2021 to August 2022. Results All lesions were identified, and stenting was performed with no complications. Conversion to manual control was not necessary. The mean fluoroscopy time was 25.25 min (range 12–60.9). A control Doppler ultrasound was routinely performed, demonstrating no residual lesions in all cases. There was no reintervention during the follow-up period. The operator learning curve was felt to be acceptable. Conclusion Robotic-assisted endovascular treatment is a feasible technique for transplant renal artery stenosis. Graphical Abstract