Jonathan C. Jaimes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonathan C. Jaimes has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Adriano Almeida Goncalves Siqueira
University of São Paulo
5 shared publications - Felix M. Escalante
São Paulo State University (UNESP), Sorocaba
3 shared publications - Marco Henrique Terra
Department of Electrical and Computer Engineering, So Carlos School of Engineering, University of So Paulo, So Carlos, Brazil
2 shared publications - Alvaro David Orjuela Canon
School of Medicine and Health Sciences, Universidad del Rosario, Bogotá, Colombia
1 shared publication - Andres L. Jutinico
Faculty of Mechanical, Electronics and Biomedical Engineering, Universidad Antonio Nariño, Bogotá, Colombia
1 shared publication - Anselmo Frizera
Graduate Program in Electrical Engineering, Federal University of Espírito Santo, Vitória, Brazil
1 shared publication
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (18) , 27285-27293
POF-Based Sensor Device for Assessment of Human--Robot Interaction Forces
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (18) , 27285-27293
POF-Based Sensor Device for Assessment of Human--Robot Interaction Forces
- 14 August 2024
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 46 (9) , 1-16
Ankle torque estimation based on disturbance observers for robotic rehabilitation
- 14 August 2024
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 46 (9) , 1-16
Ankle torque estimation based on disturbance observers for robotic rehabilitation
- 27 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1
Markovian robust filtering and control applied to rehabilitation robotics
In this paper, we deal with rehabilitation robot robust control in order to obtain best performance in the human-robot interaction. This class of system is subject to abrupt changes due to exogenous inputs and parameter variations caused, mainly, by the human dynamic behavior. In this context, Markovian jump linear systems offer suitable tools to model and control of this class of interactions. We propose force and impedance controllers based on robust recursive Markovian versions of the standard Kalman filter and the linear quadratic regulator. Different levels of the individual's actuation during the interaction with the robot define the Markov states. The measurement of electromyographic signals is used as jump parameter among Markov states. Also, a serious game is used to generate visual feedback, to promote active user participation, and to guide his movement routine. We compare our proposal with two other Markovian-based approaches and show the effectiveness our method through experiments with an ankle rehabilitation platform.
- 27 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. PP (10834435) , 1
Markovian robust filtering and control applied to rehabilitation robotics
In this paper, we deal with rehabilitation robot robust control in order to obtain best performance in the human-robot interaction. This class of system is subject to abrupt changes due to exogenous inputs and parameter variations caused, mainly, by the human dynamic behavior. In this context, Markovian jump linear systems offer suitable tools to model and control of this class of interactions. We propose force and impedance controllers based on robust recursive Markovian versions of the standard Kalman filter and the linear quadratic regulator. Different levels of the individual's actuation during the interaction with the robot define the Markov states. The measurement of electromyographic signals is used as jump parameter among Markov states. Also, a serious game is used to generate visual feedback, to promote active user participation, and to guide his movement routine. We compare our proposal with two other Markovian-based approaches and show the effectiveness our method through experiments with an ankle rehabilitation platform.
- Open Access
Polymer Optical Fiber-Based Integrated Instrumentation in a Robot-Assisted Rehabilitation Smart Environment: A Proof of Concept
Advances in robotic systems for rehabilitation purposes have led to the development of specialized robot-assisted rehabilitation clinics. In addition, advantageous features of polymer optical fiber (POF) sensors such as light weight, multiplexing capabilities, electromagnetic field immunity and flexibility have resulted in the widespread use of POF sensors in many areas. Considering this background, this paper presents an integrated POF intensity variation-based sensor system for the instrumentation of different devices. We consider different scenarios for physical rehabilitation, resembling a clinic for robot-assisted rehabilitation. Thus, a multiplexing technique for POF intensity variation-based sensors was applied in which an orthosis for flexion/extension movement, a modular exoskeleton for gait assistance and a treadmill were instrumented with POF angle and force sensors, where all the sensors were integrated in the same POF system. In addition, wearable sensors for gait analysis and physiological parameter monitoring were also proposed and applied in gait exercises. The results show the feasibility of the sensors and methods proposed, where, after the characterization of each sensor, the system was implemented with three volunteers: one for the orthosis on the flexion/extension movements, one for the exoskeleton for gait assistance and the other for the free gait analysis using the proposed wearable POF sensors. To the authors’ best knowledge, this is the first time that optical fiber sensors have been used as a multiplexed and integrated solution for the simultaneous assessment of different robotic devices and rehabilitation protocols, where such an approach results in a compact, fully integrated and low-cost system, which can be readily employed in any clinical environment.
Open AccessPolymer Optical Fiber-Based Integrated Instrumentation in a Robot-Assisted Rehabilitation Smart Environment: A Proof of Concept
Advances in robotic systems for rehabilitation purposes have led to the development of specialized robot-assisted rehabilitation clinics. In addition, advantageous features of polymer optical fiber (POF) sensors such as light weight, multiplexing capabilities, electromagnetic field immunity and flexibility have resulted in the widespread use of POF sensors in many areas. Considering this background, this paper presents an integrated POF intensity variation-based sensor system for the instrumentation of different devices. We consider different scenarios for physical rehabilitation, resembling a clinic for robot-assisted rehabilitation. Thus, a multiplexing technique for POF intensity variation-based sensors was applied in which an orthosis for flexion/extension movement, a modular exoskeleton for gait assistance and a treadmill were instrumented with POF angle and force sensors, where all the sensors were integrated in the same POF system. In addition, wearable sensors for gait analysis and physiological parameter monitoring were also proposed and applied in gait exercises. The results show the feasibility of the sensors and methods proposed, where, after the characterization of each sensor, the system was implemented with three volunteers: one for the orthosis on the flexion/extension movements, one for the exoskeleton for gait assistance and the other for the free gait analysis using the proposed wearable POF sensors. To the authors’ best knowledge, this is the first time that optical fiber sensors have been used as a multiplexed and integrated solution for the simultaneous assessment of different robotic devices and rehabilitation protocols, where such an approach results in a compact, fully integrated and low-cost system, which can be readily employed in any clinical environment.
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 10141-10147
Robust Markovian Impedance Control applied to a Modular Knee-Exoskeleton
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 10141-10147
Robust Markovian Impedance Control applied to a Modular Knee-Exoskeleton