Tao Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tao Gao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Fengtian Yue
2 shared publications- Boming Yu
School of Physics, Huazhong University of Science and Technology, Wuhan 430074, Hubei, P. R. China
1 shared publication Feng Gao
1 shared publication- Feng Gao
School of Mechanics and Civil Engineering, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication Feng-Tian Yue
School of Mechanics and Civil Engineering, State Key Laboratory for Geomechanics and Deep Underground Engineering China University of Mining and Technology, Xuzhou, China
1 shared publicationGuannan Liu
1 shared publication
Latest Publications
- 31 July 2021
- Published by World Scientific Pub Co Pte Ltd in Fractals
- Vol. 29 (06) , 2150140
A MULTI-FIELD COUPLED SEEPAGE MODEL FOR COAL SEAM WITH FRACTURES OF POWER LAW LENGTH DISTRIBUTIONS
- 31 July 2021
- Published by World Scientific Pub Co Pte Ltd in Fractals
- Vol. 29 (06) , 2150140
A MULTI-FIELD COUPLED SEEPAGE MODEL FOR COAL SEAM WITH FRACTURES OF POWER LAW LENGTH DISTRIBUTIONS
- 4 June 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 46 (1) , 9193-9210
Simulation study on heat loss from long-distance vertical-buried pipes in cooling system of heat hazard mine
In order to improve thermal and humid environment of the heat hazard mine, a ground cooling system is proposed. In the ground cooling system, the chilled water is transmitted to the air cooler in working face through long-distance vertical-buried pipes (LDVBP). Under this background, the simplified numerical heat transfer model between LDVBP and rock-soil layers is established to calculate the temperature rise and heat loss of the chilled water. Comparing the calculated results with the measured data in Wutongzhuang Coal Mine of Hebei province, the error is less than 5%. Furthermore, the numerical simulation results show the main influencing factors on heat loss of LDVBP are the heat transfer temperature difference of underground high- and low-pressure heat exchanger, flow rate, and inlet temperature of supply water when there is no groundwater seepage, which should be considered in ground cooling system design. In this study, the supply water temperature rise is 0.15°C and the comprehensive heat loss coefficient is less than 5.8%, which can meet the requirements of mine cooling engineering.
- 4 June 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 46 (1) , 9193-9210
Simulation study on heat loss from long-distance vertical-buried pipes in cooling system of heat hazard mine
In order to improve thermal and humid environment of the heat hazard mine, a ground cooling system is proposed. In the ground cooling system, the chilled water is transmitted to the air cooler in working face through long-distance vertical-buried pipes (LDVBP). Under this background, the simplified numerical heat transfer model between LDVBP and rock-soil layers is established to calculate the temperature rise and heat loss of the chilled water. Comparing the calculated results with the measured data in Wutongzhuang Coal Mine of Hebei province, the error is less than 5%. Furthermore, the numerical simulation results show the main influencing factors on heat loss of LDVBP are the heat transfer temperature difference of underground high- and low-pressure heat exchanger, flow rate, and inlet temperature of supply water when there is no groundwater seepage, which should be considered in ground cooling system design. In this study, the supply water temperature rise is 0.15°C and the comprehensive heat loss coefficient is less than 5.8%, which can meet the requirements of mine cooling engineering.