AYAhmed Youssef

Ahmed Youssef

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ahmed Youssef has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Januarti Jaya Ekaputri

    Department of Civil Engineering, Faculty of Civil, Planning and Geo Engineering, Institut Teknologi Sepuluh Nopember, Kampus ITS, Sukolilo, Surabaya 60111, Indonesia

    5 shared publications
  • Ali Ahmed

    Department of Civil Engineering, University of Engineering and Technology, Lahore, Pakistan

    3 shared publications
  • Hatem Mostafa

    Department of Structural Engineering, Faculty of Engineering, Cairo University, Giza, Egypt

    3 shared publications
  • Ali Ahmed

    Assistant Professor, Department of Civil Engineering, University of Engineering and Technology Lahore

    2 shared publications
  • Hamed Salem

    Department of Structural Engineering, Cairo University, Giza, Egypt

    2 shared publications
  • Hany Abdalla

    Department of Structural Engineering, Faculty of Engineering, Cairo University, Giza, Egypt

    2 shared publications

Latest Publications

  • Performance of fine fly ash geopolymer mortar coating to biofouling, chloride, sulfate, and carbonation in one year-marine exposure

    by Rizqi Abdi Perdanawati, Puput Risdanareni, Davin H.E. Setiamarga, A.A.N. Satria Damarnegara, Mahendra A. Maulana, I. Ketut Aria Pria Utama, I. Ketut Eddy Purnama, Anjas Handayani, Ari Widayanti, Ahmed Youssef, et al.

  • Open Access

    Investigation of Reinforced Concrete Slabs Strengthened with Shear-Connected Mesh Jacketing

    by Omar Magdy, Januarti J. Ekaputri, Mahmoud Hegazy, Ahmed Youssef

    This study investigates the effectiveness of an integrated repair technique for corroded reinforced concrete (RC) slabs using mechanical surface preparation, steel dowels, supplementary reinforcement mesh, and shotcrete jacketing. Six standard-scale RC slab specimens were tested under static two-point loading: one uncorroded control slab (S01); two corroded unrepaired slabs with steel mass losses of 10.6% (S03) and 16.2% (S02); two repaired slabs at the same corrosion levels (S06 and S05); and one uncorroded slab strengthened with compression-zone jacketing (S04). The results showed that corrosion reduced the peak load by about 14% and resulted in losses in stiffness and ductility. In contrast, the proposed repair technique not only restored the original capacity but also increased the peak load by 71–75% compared with the control slab. Although the repaired specimens exhibited higher initial stiffness, they reached their maximum load at smaller deflections, indicating reduced ductility. Compression-zone strengthening improved the peak load by 30% and enhanced post-peak behavior. No interface debonding was observed, demonstrating effective composite action, and confirming the suitability of the proposed system for rehabilitating corrosion-damaged RC slabs.

  • Open Access

    Experimental Evaluation of Concrete Structural Properties with Recycled Coarse Aggregate and Rice Husk Ash

    by Doha El-Sayed, Ahmed Youssef, Januarti J. Ekaputri, Tiao Wang, Reda Fadallah

    The present work examines the mechanical and structural performance of concrete in which rice husk ash (RHA) partially replaces cement and recycled concrete coarse aggregate (RCA) serves as an alternative to natural coarse aggregate (NCA). Fifteen concrete mixtures were prepared with RCA replacement levels of 0%, 25%, 50%, 75%, and 100% and RHA contents of 0%, 10%, and 20%. Compressive strength was evaluated at 7, 28, and 91 days, while splitting tensile strength was measured at 28 days. Additionally, the structural response of two reinforced concrete beams was assessed under both flexural and shear loading conditions for a reference beam and a beam produced with 100% RCA and 20% RHA. Results showed that increasing RCA content reduced compressive strength by approximately 2–27% and splitting tensile strength by 14.8–37.2% relative to conventional concrete. The incorporation of RHA at 10% and 20% produced similar trends, with compressive strength reductions of about 15% and 27% at 0% and 100% RCA replacement levels, respectively. Although the beam containing 100% RCA and 20% RHA exhibited lower toughness and ductility than the control beam, both beams achieved comparable ultimate load capacities and showed nearly identical responses under shear loading.

  • Open Access

    Experimental study on strengthened masonry infill walls as structural components for enhancing the lateral load resistance of reinforced concrete frame structures

    by Mohammed Zayed, Moataz Mahmoud, Ali Ahmed, Ahmed Youssef

    Enhancing the lateral load resistance of existing reinforced concrete (RC) frame structures while preserving adequate ductility remains a persistent concern in lateral strengthening, particularly when masonry infill walls are present. Although infills significantly increase stiffness and strength, they often induce brittle failure mechanisms and lead to adverse force redistribution. This study presents a comprehensive experimental investigation of the effectiveness of various infill-strengthening schemes in improving the in-plane lateral performance of RC frames subjected to monotonic lateral loading. Five 1:8 scale RC frame specimens were fabricated and tested, including a bare reference frame (RC-REF), a bare frame with a link beam to simulate the short-column effect (RC-LB), an RC frame with an infilled wall (RC-IW), an RC frame strengthened with fiber-reinforced polymer (RC-IW-FRP) layers, and a wall-infilled RC frame strengthened with steel plates at the corners (RC-IW-SP). Experimental results were extrapolated to prototype scale using similitude principles. The results demonstrate that all infill configurations substantially enhance the bare frame’s initial lateral stiffness and strength; however, this improvement is generally accompanied by a significant reduction in ductility. The FRP-strengthened infill exhibited the most favorable performance among the tested schemes—approximately 576% greater than the bare frame—while effectively mitigating brittle corner crushing and more than doubling the deformation capacity relative to the unreinforced infill. In contrast, the unreinforced infilled frame, despite a significant increase in strength, failed abruptly due to diagonal strut-induced corner crushing. The steel plate–strengthened showed limited effectiveness governed by premature anchorage slip, a phenomenon largely attributed to the challenges of maintaining exact bond similitude at the 1:8 model scale. highly sensitive to connection quality, which may not be fully captured in miniature testing. Overall, the findings identify continuous FRP confinement as an effective retrofitting strategy for masonry-infilled RC frames, as it successfully balances strength enhancement with ductility preservation. The results further highlight the potential structural hazards associated with unreinforced or partially infilled frames, emphasizing the need for their explicit consideration in structural assessment and retrofitting design.


  • Shear Behavior of Small-Scale Continuous Hidden Beams Using Tied and Spiral Stirrups

    by Mostafa Ahmed, Januarti J. Ekaputri, Hany Abdalla, Ahmed Elgamal, Ahmed Youssef

    Hidden beams in reinforced concrete (RC) structures are widely used to meet architectural requirements; however, their reduced effective depth limits shear capacity. This study investigates the shear behavior of hidden beams reinforced with innovative rectangular staggered continuous spiral stirrups, addressing the absence of design guidelines for such reinforcement systems. Nine one-eighth-scale continuous beams were tested under two-point loading, with mortar used to reduce scale effects. The influence of the number, geometry, and configuration of spiral reinforcement was investigated. Both conventional and spiral stirrups significantly improved shear performance compared to the reference beam without transverse reinforcement (HB9-No). Beams with normal stirrups (HB1-N20, HB2-N30, HB3-N40, HB4-N50) increased shear capacity by 115%, 82%, 23%, and 4%, while spiral stirrup beams (HB1-S20, HB2-S30, HB3-S40, HB4-S50) achieved corresponding increases of 174%, 144%, 73%, and 27%, respectively. Overall, spiral reinforcement enhanced shear capacity and energy dissipation by approximately 30% and 46%, respectively, compared with conventional stirrups. Prototype capacities estimated using scaling relationships were compared with international design codes, which were found to be conservative. The findings demonstrate the effectiveness of spiral stirrups in improving shear strength and ductility and emphasize the need to include their contribution in future shear design equations for hidden beams.

  • Open Access

    Experimental behavior of connection between composite columns and reinforced concrete flat slab

    by Mohamed Yousry, Hatem Mostafa, Ahmed Youssef

    The combination of concrete-filled steel tube (CFST) columns and reinforced concrete flat slabs provides a suitable structural solution that can be used to replace traditional structures in high-rise buildings. The connection between the CFST column and the RC flat slab is an important factor for this construction system to operate efficiently. In this study, a new form for the connection between the CFST column and the RC flat slab has been proposed. This connection has more constructability, where the steel tube is cut at the level of the slab to prevent the separation between the slab and the concrete inside the steel tube as the slab reinforcement is allowed to continue in the connection zone. The joint zone is strengthened with rebar rings to compensate for the loss in confinement caused by cutting the steel tube at the slab level. In addition to using longitudinal rebar in the joint zone to bear part of the vertical load and to ensure bending rigidity. The behavior of the proposed connection was investigated by testing three sets of small-sized samples. In addition, an equation based on the outcomes of the second set of tests has been carried out to determine the joint bearing capacity for the vertical load.


  • Open Access

    Experimental study on the behavior of small-scaled circular and square RC columns under various loading conditions and corrosion effect

    by Merna Elshafei, Hany Abdalla, Ahmed Youssef

    Reinforced concrete columns are vital load-bearing elements, responsible for transferring vertical loads and resisting lateral forces. While numerous factors govern column performance, this study pinpoints cross-sectional shape, transverse reinforcement configuration, and the corrosive threat as its primary areas of investigation. Thus, 20 small-scaled (1/8th scale) RC columns (square and circular, with ties or spirals) were tested under various loading conditions. Columns were divided into five groups. A preliminary test was conducted to determine individual axial load capacity through failure under axial compressive loading. The main test then explored their behavior under combined axial load and variable lateral drift compared to their behavior at two corrosion levels 15% and 25%. While corrosion levels were roughly achieved, uneven distribution due to the accelerated process concentrated pitting near construction joints, impacting reinforcement more than rebar. Results confirmed the efficacy of spirals in enhancing capacity, particularly for circular columns where they also increased lateral load capacity. However, spirals also amplified corrosion vulnerability in circular columns, suggesting a steeper decline in performance at higher corrosion levels. Two key models were derived from analyzing the recorded data: normalized total dissipated energy and normalized absolute peak load. Future research should prioritize exploring column behavior under a wider range of combined loads and corrosion levels to refine and validate these models.


  • Open Access

    Shear capacity of miniature beams with continuous staggered spiral stirrups

    by Ahmed Youssef, Shereen Mawaad, Hamed Salem

    Scaled-down-reinforced concrete beams with rectangular staggered continuous spiral stirrups are experimentally investigated. Scale-down RC beams were considered in the current research due to ease of construction and economic feasibility. As the brittle shear failure should be avoided, continuous research trials have been conducted to find an effective technique to improve shear failure mechanism. Twenty-two beams were investigated for shear behavior under 4-point static push-over load considering the normal stirrups and compared with continuous staggered spiral ones. Stirrup spacing, shear arm ratio a/d, and shear reinforcement configurations are the main variables. All beams were designed and scaled down to be one-eighth of the full-scale beams. To minimize the size effect of using small-scale models, mortar was used instead of conventional concrete. The focus in this study was related to improved shear capacity, dissipated energy, and shear cracks propagation. It was found that using spiral reinforcement instead of normal one leads to a significant enhancement in shear capacity and dissipated energy by 33% and 45%, respectively. Therefore, the prototype RC model expected capacities were detailed calculated considering the scale-down factor used by authors. The experimental results were compared by calculated values according to international standard and specifications.


  • Open Access

    Experimental investigation on corroded and non-corroded RC tunnels under different loading conditions

    by Ahmed Abdelaal, Ahmed Youssef

    Underground reinforced concrete (RC) structures, such as tunnels and pipelines, are frequently employed in urban areas and are designed to withstand both static and seismic loads, including those that occur during earthquakes. However, the inspection of deteriorated underground structures has yielded valuable findings for the civil engineering community, highlighting the need for further experimental investigation of the various damage mechanisms affecting RC tunnels under different loading conditions. This research presents a comprehensive experimental study aimed at elucidating the damage mechanisms of underground RC structures exposed to various loading conditions. Specifically, the study includes experimental testing of the corrosion of tunnel reinforcement and an investigation into the overall performance of corroded tunnels. The experimental results indicate that existing vertical loads significantly impact the lateral carrying capacity and ductility of RC tunnels.