Gábor Oszlányi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gábor Oszlányi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
András Sütő
Research Institute for Solid State Physics and Optics of the Hungarian Academy of Sciences, POB 49, H-1525 Budapest, Hungary
7 shared publicationsA. Suto
1 shared publicationLászló Párkányi
Research Institute for Solid State Physics and Optics, H-1525 Budapest POB. 49, Hungary, and Research Institute of Structural Chemistry, Chemical Research Center, H-1525 Budapest POB. 17, Hungary
1 shared publicationMátyás Czugler
Research Institute for Solid State Physics and Optics, H-1525 Budapest POB. 49, Hungary, and Research Institute of Structural Chemistry, Chemical Research Center, H-1525 Budapest POB. 17, Hungary
1 shared publication
Latest Publications
- 7 April 2011
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 67 (3) , 284-291
A charge-flipping algorithm to handle incomplete data
Missing data are a general hindrance for all iterative, dual-space methods of structure determination. Charge flipping is no exception; its real-space perturbation may turn out to be too strong if the amount of diffraction data is not sufficient. To handle this situation, we introduce a variant of the basic algorithm which combines the original charge-flipping density modification in real space, the reflector of the Fourier-modulus projection in reciprocal space and the parameterless iteration scheme of averaged alternating reflections (AAR). This simple algorithm is a balance of increased perturbations and full negative feedback, with the extra freedom that it can be fine-tuned by a different treatment of different unobserved reflections. The efficiency of the method was tested using several single-crystal data sets and varying the amount of missing data at both high and low resolution. The results prove that many small-molecule structures can be solved by utilizing significantly less data than is standard in current crystallographic practice.
- 7 April 2011
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 67 (3) , 284-291
A charge-flipping algorithm to handle incomplete data
Missing data are a general hindrance for all iterative, dual-space methods of structure determination. Charge flipping is no exception; its real-space perturbation may turn out to be too strong if the amount of diffraction data is not sufficient. To handle this situation, we introduce a variant of the basic algorithm which combines the original charge-flipping density modification in real space, the reflector of the Fourier-modulus projection in reciprocal space and the parameterless iteration scheme of averaged alternating reflections (AAR). This simple algorithm is a balance of increased perturbations and full negative feedback, with the extra freedom that it can be fine-tuned by a different treatment of different unobserved reflections. The efficiency of the method was tested using several single-crystal data sets and varying the amount of missing data at both high and low resolution. The results prove that many small-molecule structures can be solved by utilizing significantly less data than is standard in current crystallographic practice.
- Open Access
- 29 August 2010
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 66 (a1) , s107
Missing data in a modified charge-flipping algorithm
- 29 August 2010
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 66 (a1) , s107
Open AccessMissing data in a modified charge-flipping algorithm
- Open Access
- 23 August 2008
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 64 (a1) , C8
Charge flipping
- 23 August 2008
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 64 (a1) , C8
Open AccessCharge flipping
- Open Access
- 21 December 2007
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 64 (1) , 123-134
The charge flipping algorithm
This paper summarizes the current state of charge flipping, a recently developed algorithm ofab initiostructure determination. Its operation is based on the perturbation of large plateaus of low electron density but not directly on atomicity. Such a working principle radically differs from that of classical direct methods and offers complementary applications. The list of successful structure-solution cases includes periodic and aperiodic crystals using single-crystal and powder diffraction data measured with X-ray and neutron radiation. Apart from counting applications, the paper mainly deals with algorithmic issues: it describes and compares new variants of the iteration scheme, helps to identify and improve solutions, discusses the required data and the use of known information. Finally, it tries to foretell the future of such an alternative among well established direct methods.
- 21 December 2007
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 64 (1) , 123-134
Open AccessThe charge flipping algorithm
This paper summarizes the current state of charge flipping, a recently developed algorithm ofab initiostructure determination. Its operation is based on the perturbation of large plateaus of low electron density but not directly on atomicity. Such a working principle radically differs from that of classical direct methods and offers complementary applications. The list of successful structure-solution cases includes periodic and aperiodic crystals using single-crystal and powder diffraction data measured with X-ray and neutron radiation. Apart from counting applications, the paper mainly deals with algorithmic issues: it describes and compares new variants of the iteration scheme, helps to identify and improve solutions, discusses the required data and the use of known information. Finally, it tries to foretell the future of such an alternative among well established direct methods.
- 15 February 2007
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 63 (2) , 156-163
Ab initioneutron crystallography by the charge flipping method
In this paper, the charge flipping method is proposed for ab initio structure determination using neutron diffraction data alone. For this purpose, a new variant of the dual-space iterative algorithm is introduced, which is called band flipping. Unlike the basic algorithm, it reverses the sign of scattering density only within a zero-centred band, develops large plateaus without forcing positivity, and often leads to Babinet solutions. Its phasing power was tested on two organic structures. These behave similarly when using X-ray diffraction data and the basic algorithm but, with neutron data and band flipping, their solution becomes orders-of-magnitude more difficult and strongly dependent on the hydrogen content. Surprisingly, when the constraint of positivity is added, convergence speeds up to the point where structure determination using neutron diffraction data is not more difficult than the X-ray case. However, by following the evolution of the R factor, such a solution can be easily missed, and band flipping must be used both as a probe of convergence and as a tool for developing negative densities. Apart from demonstrating the feasibility of charge flipping for ab initio neutron crystallography, the present study also leads to an important byproduct: the type of traps that occasionally block the iterative process are identified and a mathematical analysis of their origin is given.
- 15 February 2007
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 63 (2) , 156-163
Ab initioneutron crystallography by the charge flipping method
In this paper, the charge flipping method is proposed for ab initio structure determination using neutron diffraction data alone. For this purpose, a new variant of the dual-space iterative algorithm is introduced, which is called band flipping. Unlike the basic algorithm, it reverses the sign of scattering density only within a zero-centred band, develops large plateaus without forcing positivity, and often leads to Babinet solutions. Its phasing power was tested on two organic structures. These behave similarly when using X-ray diffraction data and the basic algorithm but, with neutron data and band flipping, their solution becomes orders-of-magnitude more difficult and strongly dependent on the hydrogen content. Surprisingly, when the constraint of positivity is added, convergence speeds up to the point where structure determination using neutron diffraction data is not more difficult than the X-ray case. However, by following the evolution of the R factor, such a solution can be easily missed, and band flipping must be used both as a probe of convergence and as a tool for developing negative densities. Apart from demonstrating the feasibility of charge flipping for ab initio neutron crystallography, the present study also leads to an important byproduct: the type of traps that occasionally block the iterative process are identified and a mathematical analysis of their origin is given.
- 8 June 2006
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 128 (26) , 8392-8393
Charge Flipping at Work: A Case of Pseudosymmetry
Charge flipping (CF) is an amazingly simple structure solution method that uses single-crystal X-ray diffraction data. It is truly ab initio, no preliminary information on atom types, chemical composition, or space group symmetry is required. The algorithm is iterative and alternates between real and reciprocal spaces. Its simplest version only changes (flips) the sign of the electron density below a threshold, while in reciprocal space, it prescribes the moduli of observed structure factors. In this communication, we apply the algorithm in practice. The selected example presents a whole range of difficulties: it is large, contains only light atoms, is noncentrosymmetric, and shows a particularly awkward pseudosymmetry. To solve it with any of the traditional methods requires many hours of computer time, followed by a day of expert's handwork to find missing and to remove spurious atoms. In contrast, the CF algorithm provides the complete structure in a few seconds and without human intervention. It is also remarkable that the success rate is 100%, that is, any starting point in the high-dimensional phase space leads to the solution. The treatment of translational pseudosymmetry is obviously a favorable case. Similar resistant structures with pseudosymmetries or ambiguous space groups are the practical applications where the CF method could well complement standard software procedures.
- 8 June 2006
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 128 (26) , 8392-8393
Charge Flipping at Work: A Case of Pseudosymmetry
Charge flipping (CF) is an amazingly simple structure solution method that uses single-crystal X-ray diffraction data. It is truly ab initio, no preliminary information on atom types, chemical composition, or space group symmetry is required. The algorithm is iterative and alternates between real and reciprocal spaces. Its simplest version only changes (flips) the sign of the electron density below a threshold, while in reciprocal space, it prescribes the moduli of observed structure factors. In this communication, we apply the algorithm in practice. The selected example presents a whole range of difficulties: it is large, contains only light atoms, is noncentrosymmetric, and shows a particularly awkward pseudosymmetry. To solve it with any of the traditional methods requires many hours of computer time, followed by a day of expert's handwork to find missing and to remove spurious atoms. In contrast, the CF algorithm provides the complete structure in a few seconds and without human intervention. It is also remarkable that the success rate is 100%, that is, any starting point in the high-dimensional phase space leads to the solution. The treatment of translational pseudosymmetry is obviously a favorable case. Similar resistant structures with pseudosymmetries or ambiguous space groups are the practical applications where the CF method could well complement standard software procedures.
- 22 December 2004
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 61 (1) , 147-152
Ab initiostructure solution by charge flipping. II. Use of weak reflections
The original charge flipping algorithm [Oszlanyi & Suto (2004). Acta Cryst. A60, 34-141] is an amazingly simple structure solution method which works ab initio on high-resolution X-ray diffraction data. In this paper, a new version of the algorithm is presented that complements the phase exploration in reciprocal space. Instead of prescribing observed moduli of all structure factors, weak reflections are treated separately. For these reflections, calculated moduli are accepted unchanged and calculated phases are shifted by a constant Deltaphi=pi/2. This means that the observed data of weak reflections are not used in the iteration, except for the knowledge that they are indeed weak. The improvement is drastic, in some cases the success rate is increased by a factor of ten, in other cases a previously unsolvable structure becomes solvable by the modified algorithm.
- 22 December 2004
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 61 (1) , 147-152
Ab initiostructure solution by charge flipping. II. Use of weak reflections
The original charge flipping algorithm [Oszlanyi & Suto (2004). Acta Cryst. A60, 34-141] is an amazingly simple structure solution method which works ab initio on high-resolution X-ray diffraction data. In this paper, a new version of the algorithm is presented that complements the phase exploration in reciprocal space. Instead of prescribing observed moduli of all structure factors, weak reflections are treated separately. For these reflections, calculated moduli are accepted unchanged and calculated phases are shifted by a constant Deltaphi=pi/2. This means that the observed data of weak reflections are not used in the iteration, except for the knowledge that they are indeed weak. The improvement is drastic, in some cases the success rate is increased by a factor of ten, in other cases a previously unsolvable structure becomes solvable by the modified algorithm.
- Top Cited Papers
- 1 March 2004
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 60 (2) , 134-141
Ab initiostructure solution by charge flipping
In this paper, an extremely simple structure solution method termed charge flipping is presented. It works ab initio on high-resolution X-ray diffraction data in the manner of Fourier recycling. The real-space modification simply changes the sign of charge density below a threshold, while in reciprocal space the moduli F(obs) are retained resulting in an F(obs) map without weighting. The algorithm is tested using synthetic data for a wide range of structures, the solution statistics are analysed and the quality of reconstruction is checked. Finally, mathematical aspects of the algorithm are considered in detail, and these show that in this chaotic iteration process the solution is a limit cycle and not a fixed point.
- 1 March 2004
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 60 (2) , 134-141
Top Cited PapersAb initiostructure solution by charge flipping
In this paper, an extremely simple structure solution method termed charge flipping is presented. It works ab initio on high-resolution X-ray diffraction data in the manner of Fourier recycling. The real-space modification simply changes the sign of charge density below a threshold, while in reciprocal space the moduli F(obs) are retained resulting in an F(obs) map without weighting. The algorithm is tested using synthetic data for a wide range of structures, the solution statistics are analysed and the quality of reconstruction is checked. Finally, mathematical aspects of the algorithm are considered in detail, and these show that in this chaotic iteration process the solution is a limit cycle and not a fixed point.