Tomas Deveikis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomas Deveikis has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Audrius Jonaitis
Department of Electrical and Energy Systems, Kaunas University of Technology, Studentu Str. 48, LT-51367 Kaunas, Lithuania
4 shared publications - Saulius Gudžius
Department of Electrical and Energy Systems, Kaunas University of Technology, Studentu Str. 48, LT-51367 Kaunas, Lithuania
4 shared publications - Mantas Plienis
Department of Electric Power Systems, Kaunas University of Technology, Studentu Str. 48, LT-51367 Kaunas, Lithuania
2 shared publications - Mantas Zelba
Department of Electric Power Systems, Kaunas University of Technology, Studentu Street 48, LT-51367 Kaunas, Lithuania
2 shared publications - Almantas Bandza
Department of Electrical Power System, Kaunas University of Technology, 51394 Kaunas, Lithuania
1 shared publication - Andreas Giannakis
Department of Electric Power Engineering, Norwegian University of Science and Technology, 7491 Trondheim, Norway
1 shared publication
Latest Publications
- Open Access
Improved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk Analysis
The decline in power quality within electrical networks is adversely impacting the energy efficiency and safety of transmission elements. The growing prevalence of power electronics has elevated harmonic levels in the grid to an extent where their significance cannot be overlooked. Additionally, the increasing integration of renewable energy sources introduces heightened fluctuations, rendering the prediction and simulation of working modes more challenging. This paper presents an improved algorithm for calculating power transformer losses attributed to harmonics, with a comprehensive validation against simulation results obtained from the Power Factory application and real-world measurements. The advantages of the algorithm are that all evaluations are performed in real-time based on single-point measurements, and the algorithm was easy to implement in a Programmable Logic Controller (PLC). This allows us to receive the exchange of information to energy monitoring systems (EMSs) or with Power factor Correction Units (PFCUs) and control it. To facilitate a more intuitive understanding and visualization of potential hazardous scenarios related to resonance, an extra Dijkstra algorithm was implemented. This augmentation enables the identification of conditions, wherein certain branches exhibit lower resistance than the grid connection point, indicating a heightened risk of resonance and the presence of highly distorted currents. Recognizing that monitoring alone does not inherently contribute to increased energy efficiency, the algorithm was further expanded to assess transformer losses across a spectrum of Power Factory Correction Units power levels. Additionally, a command from a PLC to a PFCU can now be initiated to change the capacitance level and near-resonance working mode. These advancements collectively contribute to a more robust and versatile methodology for evaluating power transformer losses, offering enhanced accuracy and the ability to visualize potentially critical resonance scenarios.
Open AccessImproved Methodology for Power Transformer Loss Evaluation: Algorithm Refinement and Resonance Risk Analysis
The decline in power quality within electrical networks is adversely impacting the energy efficiency and safety of transmission elements. The growing prevalence of power electronics has elevated harmonic levels in the grid to an extent where their significance cannot be overlooked. Additionally, the increasing integration of renewable energy sources introduces heightened fluctuations, rendering the prediction and simulation of working modes more challenging. This paper presents an improved algorithm for calculating power transformer losses attributed to harmonics, with a comprehensive validation against simulation results obtained from the Power Factory application and real-world measurements. The advantages of the algorithm are that all evaluations are performed in real-time based on single-point measurements, and the algorithm was easy to implement in a Programmable Logic Controller (PLC). This allows us to receive the exchange of information to energy monitoring systems (EMSs) or with Power factor Correction Units (PFCUs) and control it. To facilitate a more intuitive understanding and visualization of potential hazardous scenarios related to resonance, an extra Dijkstra algorithm was implemented. This augmentation enables the identification of conditions, wherein certain branches exhibit lower resistance than the grid connection point, indicating a heightened risk of resonance and the presence of highly distorted currents. Recognizing that monitoring alone does not inherently contribute to increased energy efficiency, the algorithm was further expanded to assess transformer losses across a spectrum of Power Factory Correction Units power levels. Additionally, a command from a PLC to a PFCU can now be initiated to change the capacitance level and near-resonance working mode. These advancements collectively contribute to a more robust and versatile methodology for evaluating power transformer losses, offering enhanced accuracy and the ability to visualize potentially critical resonance scenarios.
- Open Access
- 5 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (11) , 9100
Review of Power Control Methods for a Variable Average Power Load Model Designed for a Microgrid with Non-Controllable Renewable Energy Sources
Microgrid systems may employ various combinations of system designs to connect generating units, and the number of different system designs increases exponentially upon adding different brands of inverters to a system. Each of the different microgrid system designs must be set up in a way that it works in balance. An example of an unbalanced microgrid system is given in this paper, with the main issue being the non-predictive excess power, which causes a frequency rise and faulty conditions in the microgrid system. There are many simple options for controlling excess power in a microgrid system; however, none of these options solve the issue permanently while ensuring excess power control without affecting the system’s accumulated energy—the battery state-of-charge (SOC) level. Therefore, there is a need to create a variable average power load (VAPL) device to utilize the excess power at a rate it is changing to avoid a reduction in accumulated energy. The main goal of this study is to review average power control methods for the VAPL device and provide guidance to researchers in selecting the most suitable method for controlling excess power. A key finding of the paper is a suggested optimal average power control method ensuring that the VAPL device is versatile to implement, economically attractive, and not harmful to other devices in a microgrid system.
- 5 June 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (11) , 9100
Open AccessReview of Power Control Methods for a Variable Average Power Load Model Designed for a Microgrid with Non-Controllable Renewable Energy Sources
Microgrid systems may employ various combinations of system designs to connect generating units, and the number of different system designs increases exponentially upon adding different brands of inverters to a system. Each of the different microgrid system designs must be set up in a way that it works in balance. An example of an unbalanced microgrid system is given in this paper, with the main issue being the non-predictive excess power, which causes a frequency rise and faulty conditions in the microgrid system. There are many simple options for controlling excess power in a microgrid system; however, none of these options solve the issue permanently while ensuring excess power control without affecting the system’s accumulated energy—the battery state-of-charge (SOC) level. Therefore, there is a need to create a variable average power load (VAPL) device to utilize the excess power at a rate it is changing to avoid a reduction in accumulated energy. The main goal of this study is to review average power control methods for the VAPL device and provide guidance to researchers in selecting the most suitable method for controlling excess power. A key finding of the paper is a suggested optimal average power control method ensuring that the VAPL device is versatile to implement, economically attractive, and not harmful to other devices in a microgrid system.
- Open Access
Design of IOT-Based Framework for Evaluation of Energy Efficiency in Power Transformers
Two prototypes with energy efficiency calculations have been developed to enable real-time efficiency assessment and data collection. The results of the experiment demonstrate that the use of microprocessor technology and the Internet of Things can significantly improve the efficiency and accuracy of energy audits in power transformers. The prototypes developed in this study provide real-time efficiency assessment and data collection, enabling more effective energy management and cost savings for industrial users. During the experiment, it was found that resonance can cause the same losses as a poor power factor of the system, highlighting the importance of addressing energy quality issues in addition to energy efficiency. These findings have important implications for energy efficiency policies and practices in the context of climate change mitigation and rising energy prices.
Open AccessDesign of IOT-Based Framework for Evaluation of Energy Efficiency in Power Transformers
Two prototypes with energy efficiency calculations have been developed to enable real-time efficiency assessment and data collection. The results of the experiment demonstrate that the use of microprocessor technology and the Internet of Things can significantly improve the efficiency and accuracy of energy audits in power transformers. The prototypes developed in this study provide real-time efficiency assessment and data collection, enabling more effective energy management and cost savings for industrial users. During the experiment, it was found that resonance can cause the same losses as a poor power factor of the system, highlighting the importance of addressing energy quality issues in addition to energy efficiency. These findings have important implications for energy efficiency policies and practices in the context of climate change mitigation and rising energy prices.
- Open Access
- 13 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (20) , 13110
A Grid-Tied Inverter with Renewable Energy Source Integration in an Off-Grid System with a Functional Experimental Prototype
Renewable energy implementation in residential-scale grid-connected systems is already popular, and the growth of such systems is increasing every year. Grid-connected solar systems are relatively simple to install and operate; in addition, such power plants are relatively inexpensive compared to other renewable sources and grid-connection options. However, most residential grid-connected system owners believe that they will become independent from a distribution system operator (DSO) once a renewable energy source (RES) becomes available. As a rule, after installation, without DSOs, grid-connected systems are typically shut down due to a faulty grid, despite RES availability; therefore, such RES grid-connected system owners at later phases aim to become at least partially independent of DSOs. After such a change, the importance of developing a grid-tied inverter connection to an off-grid system will increase. While developing such a system connection the main issue analyzed in this paper is to control the excess power without affecting the accumulated energy levels in a system. As a result, a solution for such a system structure is presented with its main advantage to control excess power without affecting the accumulated energy level.
- 13 October 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (20) , 13110
Open AccessA Grid-Tied Inverter with Renewable Energy Source Integration in an Off-Grid System with a Functional Experimental Prototype
Renewable energy implementation in residential-scale grid-connected systems is already popular, and the growth of such systems is increasing every year. Grid-connected solar systems are relatively simple to install and operate; in addition, such power plants are relatively inexpensive compared to other renewable sources and grid-connection options. However, most residential grid-connected system owners believe that they will become independent from a distribution system operator (DSO) once a renewable energy source (RES) becomes available. As a rule, after installation, without DSOs, grid-connected systems are typically shut down due to a faulty grid, despite RES availability; therefore, such RES grid-connected system owners at later phases aim to become at least partially independent of DSOs. After such a change, the importance of developing a grid-tied inverter connection to an off-grid system will increase. While developing such a system connection the main issue analyzed in this paper is to control the excess power without affecting the accumulated energy levels in a system. As a result, a solution for such a system structure is presented with its main advantage to control excess power without affecting the accumulated energy level.
- Open Access
- 9 February 2015
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 21 (1) , 42-47
Research of the Voltage Stability of Distribution Network Connected Induction Machines
There are a lot of wind power plants based on double feed induction machine technology which are connected to electrical network. These usually don’t consider reactive power (even reactive power consumption), so they generally affect the entire network voltage stability and can cause instability in themselves and become no longer balanced by the torque. This paper presents a method to study the relationship between the active power and voltage at the point of common coupling (PCC) connected wind power plant to identify the voltage stability limit. It is a fundament to define a permitted operation region in complying with the voltage stability limit at the PCC connected wind power.DOI: http://dx.doi.org/10.5755/j01.eee.21.1.9804
- 9 February 2015
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 21 (1) , 42-47
Open AccessResearch of the Voltage Stability of Distribution Network Connected Induction Machines
There are a lot of wind power plants based on double feed induction machine technology which are connected to electrical network. These usually don’t consider reactive power (even reactive power consumption), so they generally affect the entire network voltage stability and can cause instability in themselves and become no longer balanced by the torque. This paper presents a method to study the relationship between the active power and voltage at the point of common coupling (PCC) connected wind power plant to identify the voltage stability limit. It is a fundament to define a permitted operation region in complying with the voltage stability limit at the PCC connected wind power.DOI: http://dx.doi.org/10.5755/j01.eee.21.1.9804