Marta Calzolari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marta Calzolari has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Luisa Dias Pereira
Low Carbon & Resource Efficiency, R&Di, Instituto de Soldadura e Qualidade, 2740-120 Porto Salvo, Portugal
3 shared publications - Pietromaria Davoli
University of Ferrara
3 shared publications - Elena Lucchi
Dipartimento di Ingegneria Civile e Architettura (DICAr), University of Pavia, 27100 Pavia, Italy
2 shared publications - Mirco Andreotti
INFN Sezione di Ferrara
2 shared publications - Alexandra Troi
Institute for Renewable Energy, EURAC Research, 39100 Bolzano, Italy
1 shared publication - Dario Bottino-Leone
Institute for Renewable Energy, European Academy of Bolzano (EURAC Research), Viale Druso 1, 39100 Bolzano, Italy
1 shared publication
Latest Publications
- Open Access
Applied Research of the Hygrothermal Behaviour of an Internally Insulated Historic Wall without Vapour Barrier: In Situ Measurements and Dynamic Simulations
The hygrothermal behaviour of an internally insulated historic wall is still hard to predict, mainly because the physical characteristics of the materials composing the historic wall are unknown. In this study, the hygrothermal assessment of an internally thermal insulated masonry wall of an historic palace located in Ferrara, in Italy, is shown. In situ non-destructive monitoring method is combined with a hygrothermal simulation tool, aiming to better analyse and discuss future refurbishment scenarios. In this context, the original U-value of the wall (not refurbished) is decreased from 1.44 W/m2K to 0.26 W/m2K (10 cm stone wool). Under the site specific conditions of this wall, not reached by the sun or rain, it was verified that even in the absence of vapour barrier, no frost damage is likely to occur and the condensation risk is very limited. Authors proposed further discussion based on simulation. The results showed that the introduction of a second gypsum board to the studied technology compensated such absence, while the reduction of the insulation material thickness provides a reduction of RH peaks in the interstitial area by 1%; this second solution proved to be more efficient, providing a 3% RH reduction and the avoidance of further thermal losses.
Open AccessApplied Research of the Hygrothermal Behaviour of an Internally Insulated Historic Wall without Vapour Barrier: In Situ Measurements and Dynamic Simulations
The hygrothermal behaviour of an internally insulated historic wall is still hard to predict, mainly because the physical characteristics of the materials composing the historic wall are unknown. In this study, the hygrothermal assessment of an internally thermal insulated masonry wall of an historic palace located in Ferrara, in Italy, is shown. In situ non-destructive monitoring method is combined with a hygrothermal simulation tool, aiming to better analyse and discuss future refurbishment scenarios. In this context, the original U-value of the wall (not refurbished) is decreased from 1.44 W/m2K to 0.26 W/m2K (10 cm stone wool). Under the site specific conditions of this wall, not reached by the sun or rain, it was verified that even in the absence of vapour barrier, no frost damage is likely to occur and the condensation risk is very limited. Authors proposed further discussion based on simulation. The results showed that the introduction of a second gypsum board to the studied technology compensated such absence, while the reduction of the insulation material thickness provides a reduction of RH peaks in the interstitial area by 1%; this second solution proved to be more efficient, providing a 3% RH reduction and the avoidance of further thermal losses.
- Open Access
Design and Construction of a New Metering Hot Box for the In Situ Hygrothermal Measurement in Dynamic Conditions of Historic Masonries
The main purpose of the HeLLo project is to contribute to data available on the literature on the real hygrothermal behavior of historic walls and the suitability of insulation technologies. Furthermore, it also aims at minimizing the energy simulation errors at the design phase and at improving their conservation features. In this framework, one of the preliminary activities of the study is the creation of a real in situ hot box to measure and analyze different insulation technologies applied to a real historic wall, to quantify the hygrothermal performance of a masonry building. Inside this box, ‘traditional’ experiments can be carried out: recording heat flux, surface temperature, and air temperatures, as well as relative humidity values through the use of a new sensing system (composed of thermocouples and temperature/relative humidity combined sensors). Within this paper, the process of development, construction, and validation of this new metering box is exhibited. The new hot box, specifically studied for historic case studies, when compared to other boxes, presents other advantages compared to previous examples, widely exemplified.
Open AccessDesign and Construction of a New Metering Hot Box for the In Situ Hygrothermal Measurement in Dynamic Conditions of Historic Masonries
The main purpose of the HeLLo project is to contribute to data available on the literature on the real hygrothermal behavior of historic walls and the suitability of insulation technologies. Furthermore, it also aims at minimizing the energy simulation errors at the design phase and at improving their conservation features. In this framework, one of the preliminary activities of the study is the creation of a real in situ hot box to measure and analyze different insulation technologies applied to a real historic wall, to quantify the hygrothermal performance of a masonry building. Inside this box, ‘traditional’ experiments can be carried out: recording heat flux, surface temperature, and air temperatures, as well as relative humidity values through the use of a new sensing system (composed of thermocouples and temperature/relative humidity combined sensors). Within this paper, the process of development, construction, and validation of this new metering box is exhibited. The new hot box, specifically studied for historic case studies, when compared to other boxes, presents other advantages compared to previous examples, widely exemplified.
- Open Access
- 1 January 2020
- Published by EJournal Publishing in International Journal of Environmental Science and Development
- Vol. 11 (6) , 278-285
From the Dynamic Simulations Assessment of the Hygrothermal Behavior of Internal Insulation Systems for Historic Buildings towards the HeLLo Project
- 1 January 2020
- Published by EJournal Publishing in International Journal of Environmental Science and Development
- Vol. 11 (6) , 278-285
Open AccessFrom the Dynamic Simulations Assessment of the Hygrothermal Behavior of Internal Insulation Systems for Historic Buildings towards the HeLLo Project