ASAirton Oliveira Santos-Junior

Airton Oliveira Santos-Junior

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Airton Oliveira Santos-Junior has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Calcium Hydroxide Combined with Bioactive Glasses: Physicochemical, Antimicrobial and Bond Strength Evaluation

    by Larissa Braz Pontes, Gabriel Dutra Rissato, Pedro Luís Busto Rosim, Airton Oliveira Santos-Junior, Marina Trevelin Souza, Edgar Dutra Zanotto, Mário Tanomaru-Filho, Juliane Maria Guerreiro-Tanomaru

    This study evaluated the pH, solubility, antimicrobial activity, and bond strength of a calcium hydroxide intracanal medication (80% calcium hydroxide and 20% zirconium oxide in polyethylene glycol 400 vehicle), evaluated alone or combined with 20% F18 bioactive glass or copper-doped F18 bioactive glass. Polyethylene tubes containing the medications were immersed in distilled water. pH (n=10) was measured after 1, 3, 7, 14, and 21 days, and solubility (n=7) was determined after 7 and 14 days. Antimicrobial activity (n=6) was assessed using a modified direct contact test against Enterococcus faecalis and/or Candida albicans. For bond strength analysis (n=12), bovine roots were filled with the medications for 14 days and subsequently obturated with Bio-C Sealer or AH Plus. Specimens were subjected to a push-out test, and data were analyzed by ANOVA and Tukey’s test (α=0.05). All formulations exhibited an alkaline pH (p>0.05). The formulation without bioactive glass showed higher solubility (p<0.05). The copper-doped bioactive glass formulation was the most effective against E. faecalis in single- and dual-species biofilms (p<0.05), whereas the formulation without bioactive glass completely eradicated C. albicans (p0.05). When Bio-C Sealer was used, the F18 bioactive glass formulation exhibited the highest bond strength to dentin (p<0.05). Calcium hydroxide combined with F18 bioactive glass reduced solubility and improved the bond strength of Bio-C Sealer, whereas copper-doped bioactive glass enhanced antimicrobial performance, supporting their potential clinical applicability.

  • Open Access

    Physical and surface analysis of calcium silicate Clinker after acid challenge: a micro-CT and SEM study

    by Karina Ines Medina Carita Tavares, Airton Oliveira Santos-Junior, Jáder Camilo Pinto, Fernanda Ferrari Esteves Torres, Juliane Maria Guerreiro-Tanomaru, Mário Tanomaru-Filho

    The purpose of this study was to evaluate the effect of immersion in butyric acid (BA, pH 4.1) or phosphate-buffered saline (PBS, pH 7.0) on the properties of Clinker (CL) with particle sizes of 2 to 30 µm or < 2 µm associated with zirconium oxide and manipulated with distilled water (DW) or liquid with additives (LA) compared with Bio-C Repair (BCR) and Biodentine (BIO). Dentin tubes were prepared and filled with materials. After 24 hours, the specimens were immersed in BA or PBS (n = 5) for 7 and 28 days. Micro-computed tomography was used to evaluate volumetric change, porosity, and material/dentin interface. Surface analysis was performed by scanning electron microscopy (SEM). Statistical analyses included Kruskal-Wallis and Dunn, Mann-Whitney, Wilcoxon, unpaired t-test, paired t-test, and ANOVA and Tukey tests (α = 0.05). All groups exhibited volumetric changes similar to BCR and BIO (p > 0.05). BA significantly increased porosity (approximately 8%) compared with PBS (approximately 2%), except for CL 2 to 30 µm with LA (p < 0.05). After 28 days in BA, all groups showed increased porosity and gaps at the interface compared with baseline values (p < 0.05). CL 2 to 30 µm with DW showed greater porosity and interface gaps than the other groups (p < 0.05). SEM analysis revealed that all groups showed hydroxyapatite formation on the material surface in PBS, and structural loss in BA. Findings: Acidic pH damages the material/dentin interface, increases porosity, and promotes dimensional changes in calcium silicate cements. Distilled water without additives increases the Clinker’s porosity, interface gaps, and volume loss.

  • Open Access

    Impact of acidic pH and sealer thickness on the physical behavior of endodontic sealers: a micro-CT study

    by Karina Ines Medina Carita Tavares, Airton Oliveira Santos-Junior, Jáder Camilo Pinto, Fernanda Ferrari Esteves Torres, Juliane Maria Guerreiro-Tanomaru, Mário Tanomaru-Filho

    The aim of this study was to evaluate the effect of immersion in an acidic (butyric acid – BA; pH 4.1) or neutral (phosphate-buffered saline - PBS; pH 7.0) environment on the physical behavior of Bio-C Sealer (BCS) or AH Plus Jet (AHPJ) after filling oval root canals with different thicknesses of sealer. Thirty-two oval root canals were prepared and filled with BCS or AHPJ (n = 16), using the single-cone technique. Greater, middle, and smaller thicknesses of sealer were established in the cervical, middle, and apical thirds of the root canals, respectively. Then, the samples were immersed in BA or PBS (n = 8) for time intervals of 7 and 30 days. Micro-CT scans were performed after the materials set and after the experimental time intervals ended. Volumetric change and the percentage of voids and gaps at the material/dentin interface were evaluated. Kruskal-Wallis and Dunn, Friedman, Wilcoxon paired, and ANOVA/Tukey tests were performed (α = 0.05). Significant volumetric change and percentage of voids and gaps at the interface of BCS and AHPJ were observed in BA after 30 days (p < 0.05). Both materials showed a higher percentage of voids and volumetric loss in the greater sealer thickness (p < 0.05). Baseline showed a lower percentage of voids and gaps at the interface when compared with the experimental periods (p < 0.05). An acidic environment harms the properties of endodontic sealers after 30 days. The greater sealer thickness negatively affected the volumetric change and presence of voids in oval root canals.

  • Open Access

    Physicochemical and antibiofilm properties of new ready-to-use and powder/gel bioceramic endodontic sealers.

    by Jéssica Arielli Pradelli, José Leandro de Abreu Jampani, Airton Oliveira Santos-Junior, Mario Tanomaru-Filho, Juliane Maria Guerreiro-Tanomaru

    NeoSealer Flo (NSF) is a novel ready-to-use endodontic bioceramic sealer, and NeoMTA2 (NMTA2) is a powder-gel bioceramic used as a repair or filling material. Setting time (ST), pH, solubility, radiopacity, and flow were evaluated in accordance with the ISO 6876:2012 standards for NSF and NMTA2, in comparison with Bio-C Sealer (BCS) and AH Plus Jet (AHP). Bond strength was assessed using the push-out test. Antibiofilm activity was evaluated by a modified direct contact test on Enterococcus faecalis biofilm with fresh sealer eluate and material after setting. Data were analyzed using the t-test, ANOVA, and Tukey post-hoc tests (α = 0.05). AHP exhibited the highest ST value, followed by NMTA2 (p < 0.05). NSF and BCS showed solubility above 3%, while NMTA2 exhibited values lower than 3% (p < 0.05). All materials demonstrated radiopacity above 3 mm Al (p > 0.05). NMTA2 demonstrated flow below ISO-recommendation (p < 0.05). NSF showed the highest bond strength values (p < 0.05). The bioceramic sealers induced higher pH compared with AHP (p < 0.05). NMTA2 exhibited more significant antibiofilm activity after the sealer set (p < 0.05). For fresh sealer eluate, NSF, BCS, and AHP demonstrated higher levels of antibiofilm activity compared with NMTA2 (p < 0.05). NSF and NMTA2 demonstrated the required physicochemical and mechanical properties, as well as antibiofilm activity against E. faecalis. However, NSF and BCS presented higher solubility. NMTA2 presented adequate solubility, however lower flow rates than those recommended by ISO standards.


  • Effectiveness and safety of three NiTi systems in endodontic retreatment of MB1 and MB2 root canals: a micro-CT and CBCT combined analysis

    by Airton Oliveira Santos-Junior, Rocharles Cavalcante Fontenele, Karina Ines Medina Carita Tavares, Fernanda Ferrari Esteves Torres, Jáder Camilo Pinto, Pedro Luis Busto Rosim, Andréa Gonçalves, Marco Antonio Hungaro Duarte, Juliane Maria Guerreiro-Tanomaru, Mário Tanomaru-Filho

    Objective To evaluate the performance in endodontic retreatment and pericervical dentin preservation using ProDesign Logic (PDL), Reciproc Blue (RB), and WaveOne Gold (WOG) NiTi systems in first (MB1) and second (MB2) mesiobuccal root canals of maxillary molars, using cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT). Materials and methods MB1 and MB2 canals were prepared, filled, and randomized into four groups (n = 8). MB1 were retreated using PDL up to file 40/0.05 or RB R40 (40/0.06), while MB2 were retreated using PDL up to file 35/0.05 or WOG (35/0.06). Micro-CT scans were performed before and after retreatment to assess the remaining filling material, canal transportation, and canal centralization. Dentin removal and remaining dentin were measured at four levels below the furcation through CBCT scans analyzed with the e-Vol DX software, with micro-CT serving as the reference standard. Results RB was more effective than PDL in removing MB1 filling material, while PDL outperformed WOG in the apical third of MB2 (p < 0.05). Overall, CBCT measurements for dentin removal were consistent with micro-CT in MB1 but occasionally underestimated in MB2 (p < 0.05). A significant reduction in MB2 danger zone dentin thickness below 0.5 mm was observed after retreatment (p < 0.05). Conclusions RB was more effective in retreating MB1, while PDL was more efficient in the apical third of MB2. A substantial decrease in dentin thickness in the MB2 danger zone was noted after retreatment, regardless of the NiTi system or imaging modality used. Overall, CBCT scans provided consistent assessments of dentin. Clinical relevance Selecting appropriate NiTi systems minimizes dentin removal in MB1 and MB2 danger zones, reducing the risk of perforation in the furcation area. CBCT reliably assesses dentin thickness, aiding clinical decisions and improving endodontic retreatment outcomes.


  • Open Access

    A novel artificial intelligence‐powered tool for automated root canal segmentation in single‐rooted teeth on cone‐beam computed tomography

    by Airton Oliveira Santos‐Junior, Rocharles Cavalcante Fontenele, Frederico Sampaio Neves, Mário Tanomaru‐Filho, Reinhilde Jacobs

    Aim: To develop and validate an artificial intelligence (AI)‐powered tool based on convolutional neural network (CNN) for automatic segmentation of root canals in single‐rooted teeth using cone‐beam computed tomography (CBCT).Methodology: A total of 69 CBCT scans were retrospectively recruited from a hospital database and acquired from two devices with varying protocols. These scans were randomly assigned to the training (n = 31, 88 teeth), validation (n = 8, 15 teeth) and testing (n = 30, 120 teeth) sets. For the training and validation data sets, each CBCT scan was imported to the Virtual Patient Creator platform, where manual segmentation of root canals was performed by two operators, establishing the ground truth. Subsequently, the AI model was tested on 30 CBCT scans (120 teeth), and the AI‐generated three‐dimensional (3D) virtual models were exported in standard triangle language (STL) format. Importantly, the testing data set encompassed different types of single‐rooted teeth. An experienced operator evaluated the automated segmentation, and manual refinements were made to create refined 3D models (R‐AI). The AI and R‐AI models were compared for performance evaluation. Additionally, 30% of the testing sample was manually segmented at two different times to compare AI‐based and human segmentation methods. The time taken by each segmentation method to obtain 3D models was recorded in seconds(s) for further comparison.Results: The AI‐driven tool demonstrated highly accurate segmentation of single‐rooted teeth (Dice similarity coefficient [DSC] ranging from 89% to 93%; 95% Hausdorff distance [HD] ranging from 0.10 to 0.13 mm), with no significant impact of tooth type on accuracy metrics (p > .05). The AI approach outperformed the manual method (p < .05), showing higher DSC and lower 95% HD values. In terms of time efficiency, manual segmentation required significantly more time (2262.4 ± 679.1 s) compared to R‐AI (94 ± 64.7 s) and AI (41.8 ± 12.2 s) methods (p < .05), representing a 54‐fold decrease.Conclusions: The novel AI‐based tool exhibited highly accurate and time‐efficient performance in the automatic root canal segmentation on CBCT, surpassing the human performance.


  • Open Access

    Effect of F18 Bioactive Glass-Treated Gutta-Percha on Interaction with Endodontic Sealers

    by David Hernández Maldonado, José Leandro de Abreu Jampani, Airton Oliveira Santos-Júnior, Marina Trevelin Souza, Edgar Dutra Zanotto, Juliane Maria Guerreiro-Tanomaru, Mário Tanomaru-Filho

    This study evaluated the effect of F18 bioactive glass applied to gutta-percha by dip-coating or incorporation on surface bioactivity and bond strength to Bio-C Sealer (BCS) and AH Plus (AHP). Gutta-percha discs (n = 3 per group) were dip-coated with F18 bioactive glass at 2.5%, 5%, and 10% by weight and analyzed by SEM and EDS before and after 28 days of immersion in PBS. Uncoated gutta-percha served as the control for analyses. For the tensile bond strength test, twelve specimens per group (n = 12) were prepared using unmodified gutta-percha, 5% F18 dip-coated gutta-percha, or 2% F18-incorporated gutta-percha, each tested with BCS and AHP. Unmodified gutta-percha with each sealer served as the control. Bond strength was measured using a universal testing machine and analyzed by two-way ANOVA and Tukey's test (α = 0.05). After PBS immersion, the 5% and 10% dip-coated groups exhibited more pronounced F18 deposition and the formation of continuous bioactive surface layers, whereas the control group showed no such features. Regarding bond strength, the 5% F18 dip-coated gutta-percha showed higher values with BCS compared to the control (p < 0.05), and the 2% F18-incorporated gutta-percha also increased bond strength to BCS versus the control (p < 0.05). For AHP, 5% dip-coating reduced bond strength compared with the control (p < 0.05), whereas 2% incorporation did not differ (p > 0.05). F18 bioactive glass promoted surface mineralization of gutta-percha and improved its bond strength to Bio-C Sealer, whether applied by dip-coating or incorporation.


  • Open Access

    Effect of the Blooming Artifact Reduction filter on the detection of voids in root canal fillings using cone-beam computed tomography images

    by Airton Oliveira Santos-Junior, Rocharles Cavalcante Fontenele, Jáder Camilo Pinto, André Ferreira Leite, Fernanda Ferrari Esteves Torres, Karina Ines Medina Carita Tavares, Marcelo Gonçalves, Juliane Maria Guerreiro-Tanomaru, Mário Tanomaru-Filho

    This study evaluated the effectiveness of the blooming artifact reduction (BAR) filter (e-Vol DX Software, CDT, Bauru, SP, Brazil) for detecting voids in root canals filled with various sealers, using two CBCT devices and micro-CT as a reference. Twenty mandibular incisors with long-oval root canals were filled with AH Plus Jet (AHPJ) or Bio-C Sealer (BCS). Each tooth was placed in the mandibular alveolar socket of a dry skull, covered with Mix-D material, and scanned with VeraView X800 and OP300 Maxio CBCT devices. Micro-CT images served as a reference. Three calibrated examiners assessed the CBCT scans, without and with the BAR filter (intensity level 1 for OP300 Maxio and level 3 for VeraView X800), for void detection using a 5-point scale. Diagnostic values (area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity) were compared using multi-way analysis of variance (p=0.05). Intra- and inter-observer agreement was evaluated using the weighted Kappa index. For OP300, using BAR filter 1 significantly improved ROC curve values for detecting voids in the apical third with AHPJ and BCS (p<0.05). It also increased specificity for detecting voids in the apical third with AHPJ (p0.05), but using BAR filter 3 significantly enhanced specificity for detecting voids in the cervical/middle thirds with BCS (p<0.05). The diagnostic performance of the BAR filter is CBCT-device dependent. In OP300 scans, it enhances the detection of voids in the apical third with AHPJ and BCS. In VeraView X800 scans, it improves specificity for detecting voids in the cervical/middle thirds with BCS.

  • Open Access

    Physicochemical properties, bond strength, and antibiofilm activity of a powder-gel bioceramic endodontic sealer

    by Jéssica Arielli Pradelli, Pedro Luís Busto Rosim, Airton Oliveira Santos-Junior, Mario Tanomaru-Filho, Juliane Maria Guerreiro-Tanomaru

    Physicochemical properties, bond strength, and antibiofilm activity of a powder-gel bioceramic endodontic sealer, Sealer Plus BC (SPBC, MK Life, Porto Alegre, RS, Brazil), were evaluated in comparison with Bio-C Sealer (BCS, Angelus, Londrina, PR, Brazil), a reference bioceramic sealer, and AH Plus Jet (AHP, Dentsply DeTrey, Konstanz, Germany), a standard resin-based sealer. The setting time, pH, solubility, flow, and radiopacity were evaluated in accordance with ISO 6876:2012 standards. Bond strength was measured using the Push-Out test. Antibiofilm activity against Enterococcus faecalis alone or in combination with Candida albicans was assessed using a modified direct contact test with the eluate of fresh sealer (25 mg/mL) and after 24 hours of material setting. The data were analyzed using ANOVA and Tukey statistical tests (α = 0.05). SPBC exhibited higher Setting Time values compared to BCS and lower values compared to AHP (p < 0.05). BCS and SPBC had higher solubility values than 3% (p<0.05). BCS demonstrated flow values higher than those of SPBC and AHP (p<0.05). SPBC showed lower radiopacity (p<0.05) and higher bond strength (p<0.05) than BCS and AHP. SPBC and BCS exhibited alkaline pH throughout all evaluated periods. They demonstrated antimicrobial activity against Enterococcus faecalis and/or Candida albicans in the eluate of fresh sealer and 24 hours after setting (p < 0.05). In conclusion, SPBC powder-gel sealer, as a filling material, meets most ISO 6876 standards for physicochemical properties, demonstrates bond strength to dentin, and exhibits antimicrobial activity against both dual and single-specimen biofilms. However, it has a solubility greater than 3%.


  • Open Access

    Influence of Bioceramic Clinker particle size, radiopacifier, and liquids on their physicochemical properties

    by Karina Ines Medina Carita Tavares, Airton Oliveira Santos-Junior, Jáder Camilo Pinto, Fernanda Ferrari Esteves Torres, Marco Antonio Hungaro Duarte, Juliane Maria Guerreiro-Tanomaru, Mário Tanomaru-Filho

    This study evaluated the addition of calcium tungstate (CaWO4) as a radiopacifier and the manipulation with distilled water (DW) or liquid with additives (LA) on the physicochemical properties of Clinker (CL; Angelus) with different particle sizes (2 to 30 µm and t-tests were performed (α=0.05). CL 2 to 30 µm showed shorter initial ST and higher final ST when manipulated with LA (p4 increased the CL radiopacity for both particle sizes (p0.05). All materials presented alkaline pH (p>0.05), especially in 24 hours and 7 days. Regarding the solubility, all groups exhibited mass gain, while White MTA in distilled water demonstrated mass loss (p4 showed greater mass gain and higher radiopacity when manipulated with LA than DW (p<0.05). CL <2 µm manipulated with LA provides a shorter final ST. Both particle sizes positively influence the alkalization capacity of CL, especially in the initial periods. The addition of calcium tungstate and manipulation using LA showed adequate physicochemical properties for clinical application.