Felix Doellinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Felix Doellinger has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
Jacopo Saccomanno
Department of Infectious Diseases and Respiratory Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
4 shared publicationsRalf-Harto Hübner
Department of Infectious Diseases and Respiratory Medicine, Charité - Universitätsmedizin Berlin, Berlin, Germany
3 shared publicationsChristoph Ruwwe-Glösenkamp
Department of Infectious Diseases and Respiratory Medicine, Charité -Universitätsmedizin Berlin, Berlin, Germany
2 shared publications- Felix Wilhelm Feldhaus
Department of Radiology, Charité Universitätsmedizin Berlin, Berlin, Germany
2 shared publications Jobst Roehmel
Department of Pediatric Respiratory Medicine, Immunology and Critical Care Medicine, Charité–Universitätsmedizin Berlin, Berlin, Germany
2 shared publications- Konrad Neumann
Institute of Biometry and Clinical Epidemiology, Charité—Universitätsmedizin Berlin, corporate member of Freie Universität Berlin und Humboldt-Universität zu Berlin, 10117 Berlin, Germany
2 shared publications
Latest Publications
- 23 December 2025
- Published by Springer Nature in European Radiology
- Vol. 36 (5) , 4140-4151
MRI scoring of pleural findings in cystic fibrosis does not require intravenous contrast media
Objectives Cystic fibrosis (CF) leads to severe lung disease requiring regular monitoring. The morpho-functional chest MRI score enables reproducible semi-quantitative assessment of CF-related pulmonary and pleural changes, but the optimal sequences for pleural evaluation and the need for intravenous contrast media remain uncertain. This study aims to investigate the usability and agreement of different unenhanced and contrast-enhanced MRI sequences in assessing CF-related pleural findings using a blinded multi-reader study design. Materials and methods This study included 75 people with CF (pwCF), who underwent morpho-functional chest MRI comprising contrast-enhanced and unenhanced sequences. Three 3D gradient echo T1-weighted sequences (unenhanced with (T1UEFS) and without fat saturation (T1UE), contrast-enhanced with fat saturation (T1CEFS)) and a high-resolution T2-weighted sequence with fat saturation (T2FS) were evaluated by two blinded independent readers applying the chest MRI scoring system for each individual lung lobe and the entire pleura (lobar/total pleural findings score). In case of deviations, a thoracic radiologist adjudicated. Statistical analyses included Spearman’s correlation, Kruskal–Wallis test, and intraclass correlation coefficients. Results Interreader agreement was consistently good for all sequences and for all pulmonary lobes. While all unenhanced MRI sequences showed strong correlation with T1CEFS regarding the total pleural findings score, T1UEFS showed the highest agreement. T2FS tended to overestimate, and T1UE tended to underestimate lobar and total pleural findings scores. Conclusions Contrast-enhanced T1-weighted imaging is standard for assessing CF-related pleural inflammation and thickening. Our findings show that contrast agent-free fat-saturated T1-weighted sequences provide equivalent diagnostic value, indicating contrast media are not required for pleural assessment in pwCF. Key Points Question It is unclear which MRI sequence is best for assessing signs of pleurisy in pwCF and whether intravenous contrast media is required. Findings Pleural inflammation and thickening can be diagnosed just as precisely with an unenhanced fat-saturated T1-weighted sequence as with a contrast-enhanced T1-weighted sequence. Clinical relevance The assessment of pleural findings in MRI is not dependent on the use of intravenous contrast media. For pwCF, this paves the way for future routine MRI monitoring without contrast agents, thereby streamlining imaging protocols and reducing patient burden. Graphical Abstract
- 23 December 2025
- Published by Springer Nature in European Radiology
- Vol. 36 (5) , 4140-4151
MRI scoring of pleural findings in cystic fibrosis does not require intravenous contrast media
Objectives Cystic fibrosis (CF) leads to severe lung disease requiring regular monitoring. The morpho-functional chest MRI score enables reproducible semi-quantitative assessment of CF-related pulmonary and pleural changes, but the optimal sequences for pleural evaluation and the need for intravenous contrast media remain uncertain. This study aims to investigate the usability and agreement of different unenhanced and contrast-enhanced MRI sequences in assessing CF-related pleural findings using a blinded multi-reader study design. Materials and methods This study included 75 people with CF (pwCF), who underwent morpho-functional chest MRI comprising contrast-enhanced and unenhanced sequences. Three 3D gradient echo T1-weighted sequences (unenhanced with (T1UEFS) and without fat saturation (T1UE), contrast-enhanced with fat saturation (T1CEFS)) and a high-resolution T2-weighted sequence with fat saturation (T2FS) were evaluated by two blinded independent readers applying the chest MRI scoring system for each individual lung lobe and the entire pleura (lobar/total pleural findings score). In case of deviations, a thoracic radiologist adjudicated. Statistical analyses included Spearman’s correlation, Kruskal–Wallis test, and intraclass correlation coefficients. Results Interreader agreement was consistently good for all sequences and for all pulmonary lobes. While all unenhanced MRI sequences showed strong correlation with T1CEFS regarding the total pleural findings score, T1UEFS showed the highest agreement. T2FS tended to overestimate, and T1UE tended to underestimate lobar and total pleural findings scores. Conclusions Contrast-enhanced T1-weighted imaging is standard for assessing CF-related pleural inflammation and thickening. Our findings show that contrast agent-free fat-saturated T1-weighted sequences provide equivalent diagnostic value, indicating contrast media are not required for pleural assessment in pwCF. Key Points Question It is unclear which MRI sequence is best for assessing signs of pleurisy in pwCF and whether intravenous contrast media is required. Findings Pleural inflammation and thickening can be diagnosed just as precisely with an unenhanced fat-saturated T1-weighted sequence as with a contrast-enhanced T1-weighted sequence. Clinical relevance The assessment of pleural findings in MRI is not dependent on the use of intravenous contrast media. For pwCF, this paves the way for future routine MRI monitoring without contrast agents, thereby streamlining imaging protocols and reducing patient burden. Graphical Abstract
- Top Cited Papers
- 24 February 2025
- Published by Elsevier in Annals of the Rheumatic Diseases
- Vol. 84 (4) , 653-656
Teclistamab in relapsed systemic sclerosis after autologous haematopoietic stem cell transplantation
- 24 February 2025
- Published by Elsevier in Annals of the Rheumatic Diseases
- Vol. 84 (4) , 653-656
Top Cited PapersTeclistamab in relapsed systemic sclerosis after autologous haematopoietic stem cell transplantation
- 1 November 2024
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 21 (11) , 1550-1559
Long-Term Impact of Lumacaftor/Ivacaftor Treatment on Cystic Fibrosis Disease Progression in Children 2–5 Years of Age Homozygous for F508del-CFTR : A Phase 2, Open-Label Clinical Trial
Rationale: Clinical trials show that lumacaftor/ivacaftor (LUM/IVA) treatment has the potential to modify early cystic fibrosis (CF) disease progression in children as young as 2 years of age. Objectives: To assess the long-term impact of LUM/IVA treatment on CF disease progression in children aged 2–5 years. Methods: This phase 2 trial had two parts: part 1, a 48-week, randomized, double-blind, placebo-controlled study of LUM/IVA in children aged 2–5 years (previously reported) was followed by a 48-week open-label treatment period in which all children received LUM/IVA (part 2; reported here). Endpoints assessed in part 2 included absolute changes from baseline in chest magnetic resonance imaging (MRI) global score at Week 96; weight-for-age, stature-for-age, and body mass index (BMI)-for-age z-scores at Week 96; lung clearance index based on lung volume turnover required to reach 2.5% of starting N2 concentration (LCI2.5) through Week 96; chest MRI morphological score, chest MRI perfusion score, weight, stature, BMI, and microbiology cultures (oropharyngeal swabs) at Week 96; sweat chloride, amount of immunoreactive trypsinogen, fecal elastase-1 concentration, and fecal calprotectin through Week 96; and number of pulmonary exacerbations, time to first pulmonary exacerbation, and number of CF-related hospitalizations. Results: Forty-nine children received one or more doses of LUM/IVA in the open-label period (33 in the LUM/IVA to LUM/IVA group and 16 in the placebo to LUM/IVA group), with a mean exposure of 47.1 (standard deviation [SD], 5.2) weeks. The mean absolute change in MRI global score (negative value indicates improvement) from baseline at Week 96 was −2.7 (SD, 7.0; 95% confidence interval [CI], −5.2 to −0.1) in the LUM/IVA to LUM/IVA group and −5.6 (SD, 6.9; 95% CI, −9.2 to −1.9) in the placebo to LUM/IVA group. Improvements in LCI2.5, sweat chloride concentration, and markers of pancreatic function and intestinal inflammation were also observed in both groups. Growth parameters remained stable in both groups. The majority of children had adverse events considered mild (38.8%) or moderate (40.8%). Two (4.1%) children discontinued LUM/IVA treatment because of adverse events (distal intestinal obstruction syndrome [n = 1] and alanine aminotransferase increase [n = 1]). Conclusions: These findings confirm the potential for early LUM/IVA treatment to alter the trajectory of CF disease progression, including CF lung disease, in children as young as 2 years of age. Clinical trial registered with ClinicalTrials.gov (NCT03625466).
- 1 November 2024
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 21 (11) , 1550-1559
Long-Term Impact of Lumacaftor/Ivacaftor Treatment on Cystic Fibrosis Disease Progression in Children 2–5 Years of Age Homozygous for F508del-CFTR : A Phase 2, Open-Label Clinical Trial
Rationale: Clinical trials show that lumacaftor/ivacaftor (LUM/IVA) treatment has the potential to modify early cystic fibrosis (CF) disease progression in children as young as 2 years of age. Objectives: To assess the long-term impact of LUM/IVA treatment on CF disease progression in children aged 2–5 years. Methods: This phase 2 trial had two parts: part 1, a 48-week, randomized, double-blind, placebo-controlled study of LUM/IVA in children aged 2–5 years (previously reported) was followed by a 48-week open-label treatment period in which all children received LUM/IVA (part 2; reported here). Endpoints assessed in part 2 included absolute changes from baseline in chest magnetic resonance imaging (MRI) global score at Week 96; weight-for-age, stature-for-age, and body mass index (BMI)-for-age z-scores at Week 96; lung clearance index based on lung volume turnover required to reach 2.5% of starting N2 concentration (LCI2.5) through Week 96; chest MRI morphological score, chest MRI perfusion score, weight, stature, BMI, and microbiology cultures (oropharyngeal swabs) at Week 96; sweat chloride, amount of immunoreactive trypsinogen, fecal elastase-1 concentration, and fecal calprotectin through Week 96; and number of pulmonary exacerbations, time to first pulmonary exacerbation, and number of CF-related hospitalizations. Results: Forty-nine children received one or more doses of LUM/IVA in the open-label period (33 in the LUM/IVA to LUM/IVA group and 16 in the placebo to LUM/IVA group), with a mean exposure of 47.1 (standard deviation [SD], 5.2) weeks. The mean absolute change in MRI global score (negative value indicates improvement) from baseline at Week 96 was −2.7 (SD, 7.0; 95% confidence interval [CI], −5.2 to −0.1) in the LUM/IVA to LUM/IVA group and −5.6 (SD, 6.9; 95% CI, −9.2 to −1.9) in the placebo to LUM/IVA group. Improvements in LCI2.5, sweat chloride concentration, and markers of pancreatic function and intestinal inflammation were also observed in both groups. Growth parameters remained stable in both groups. The majority of children had adverse events considered mild (38.8%) or moderate (40.8%). Two (4.1%) children discontinued LUM/IVA treatment because of adverse events (distal intestinal obstruction syndrome [n = 1] and alanine aminotransferase increase [n = 1]). Conclusions: These findings confirm the potential for early LUM/IVA treatment to alter the trajectory of CF disease progression, including CF lung disease, in children as young as 2 years of age. Clinical trial registered with ClinicalTrials.gov (NCT03625466).
- 2 February 2023
- Published by S. Karger AG in Respiration
- Vol. 102 (4) , 296-307
Bronchoscopic Measurement of Collateral Ventilation: State of the Art
Endoscopic lung volume reduction procedure with valves is a well-studied treatment option for advanced lung emphysema to target lung hyperinflation in carefully selected patients with COPD. Before valve implantation, collateral ventilation (CV) of the target lobe needs to be assessed to obtain an optimal treatment effect. The analysis of CV according to current standards occurs via an in vivo assessment with the Chartis®system (PulmonX Inc., Redwood City, CA, USA) and a computed tomography (CT) scan of the thorax with interlobar fissure analysis. The focus of this review is to provide detailed information about the Chartis®procedure and interpretation of Chartis® phenotypes. As a main tool in the assessment of CV and being a safe procedure, the Chartis® assessment should be performed by default to confirm interlobar fissure analysis in most emphysema patients. Based on the obtained results, lung volume reduction therapy options should be discussed in an interdisciplinary emphysema conference.
- 2 February 2023
- Published by S. Karger AG in Respiration
- Vol. 102 (4) , 296-307
Bronchoscopic Measurement of Collateral Ventilation: State of the Art
Endoscopic lung volume reduction procedure with valves is a well-studied treatment option for advanced lung emphysema to target lung hyperinflation in carefully selected patients with COPD. Before valve implantation, collateral ventilation (CV) of the target lobe needs to be assessed to obtain an optimal treatment effect. The analysis of CV according to current standards occurs via an in vivo assessment with the Chartis®system (PulmonX Inc., Redwood City, CA, USA) and a computed tomography (CT) scan of the thorax with interlobar fissure analysis. The focus of this review is to provide detailed information about the Chartis®procedure and interpretation of Chartis® phenotypes. As a main tool in the assessment of CV and being a safe procedure, the Chartis® assessment should be performed by default to confirm interlobar fissure analysis in most emphysema patients. Based on the obtained results, lung volume reduction therapy options should be discussed in an interdisciplinary emphysema conference.
- Open Access
- 11 October 2022
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 17, 2553-2566
When Treatment of Pulmonary Emphysema with Endobronchial Valves Did Not Work: Evaluation of Quantitative CT Analysis and Pulmonary Function Tests Before and After Valve Explantation
Purpose: To investigate changes in quantitative CT analysis (QCT) and pulmonary function tests (PFT) in pulmonary emphysema patients who required premature removal of endobronchial valves (EBV). Patients and Methods: Our hospital’s medical records listed 274 patients with high-grade COPD (GOLD stages 3 and 4) and pulmonary emphysema who were treated with EBV to reduce lung volume. Prior to intervention, a complete evaluation was performed that included quantitative computed tomography analysis (QCT) of scans acquired at full inspiration and full expiration, pulmonary function tests (PFT), and paraclinical findings (6-minute walking distance test (6MWDT) and quality of life questionnaires). In 41 of these 274 patients, EBV treatment was unsuccessful and the valves had to be removed for various reasons. A total of 10 of these 41 patients ventured a second attempt at EBV therapy and underwent complete reevaluation. In our retrospective study, results from three time points were compared: Before EBV implantation (BL), after EBV implantation (TP2), and after EBV explantation (TP3). QCT parameters included lung volume, total emphysema score (TES, ie, the emphysema index) and the 15th percentile of lung attenuation (P15) for the whole lung and each lobe separately. Differences in these parameters between inspiration and expiration were calculated (Vol. Diff (%), TES Diff (%), P15 Diff (%)). The results of PFT and further clinical tests were taken from the patient’s records. Results: We found persistent therapy effect in the target lobe even after valve explantation together with a compensatory hyperinflation of the rest of the lung. As a result of these two divergent effects, the volume of the total lung remained rather constant. Furthermore, there was a slight deterioration of the emphysema score for the whole lung, whereas the TES of the target lobe persistently improved. Conclusion: Interestingly, we found evidence that, contrary to our expectations, unsuccessful EBV therapy can have a persistent positive effect on target lobe QCT scores.
- 11 October 2022
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 17, 2553-2566
Open AccessWhen Treatment of Pulmonary Emphysema with Endobronchial Valves Did Not Work: Evaluation of Quantitative CT Analysis and Pulmonary Function Tests Before and After Valve Explantation
Purpose: To investigate changes in quantitative CT analysis (QCT) and pulmonary function tests (PFT) in pulmonary emphysema patients who required premature removal of endobronchial valves (EBV). Patients and Methods: Our hospital’s medical records listed 274 patients with high-grade COPD (GOLD stages 3 and 4) and pulmonary emphysema who were treated with EBV to reduce lung volume. Prior to intervention, a complete evaluation was performed that included quantitative computed tomography analysis (QCT) of scans acquired at full inspiration and full expiration, pulmonary function tests (PFT), and paraclinical findings (6-minute walking distance test (6MWDT) and quality of life questionnaires). In 41 of these 274 patients, EBV treatment was unsuccessful and the valves had to be removed for various reasons. A total of 10 of these 41 patients ventured a second attempt at EBV therapy and underwent complete reevaluation. In our retrospective study, results from three time points were compared: Before EBV implantation (BL), after EBV implantation (TP2), and after EBV explantation (TP3). QCT parameters included lung volume, total emphysema score (TES, ie, the emphysema index) and the 15th percentile of lung attenuation (P15) for the whole lung and each lobe separately. Differences in these parameters between inspiration and expiration were calculated (Vol. Diff (%), TES Diff (%), P15 Diff (%)). The results of PFT and further clinical tests were taken from the patient’s records. Results: We found persistent therapy effect in the target lobe even after valve explantation together with a compensatory hyperinflation of the rest of the lung. As a result of these two divergent effects, the volume of the total lung remained rather constant. Furthermore, there was a slight deterioration of the emphysema score for the whole lung, whereas the TES of the target lobe persistently improved. Conclusion: Interestingly, we found evidence that, contrary to our expectations, unsuccessful EBV therapy can have a persistent positive effect on target lobe QCT scores.
- 3 December 2021
- Published by S. Karger AG in Respiration
- Vol. 101 (4) , 408-416
Impact of Ventilation Modes on Bronchoscopic Chartis Assessment Outcome in Candidates for Endobronchial Valve Treatment
Background: Endobronchial valve therapy has proven to reduce lung hyperinflation and decrease disease burden in patients with severe lung emphysema. Exclusion of collateral ventilation (CV) of the targeted lobe by using an endobronchial assessment system (Chartis; PulmonX, Drive Redwood City, CA, USA) in combination with software-based fissure integrity analysis (FCS [fissure completeness score]) of computed tomography scans of the lung are established tools to select appropriate patients for endobronchial valve treatment. So far, there is no conclusive evidence if the ventilation mode during bronchoscopy impacts the outcome of Chartis assessments. Methods: Patients with Chartis assessments and software-based quantification of FCS (StratX; PulmonX, Drive Redwood City, CA, USA) were enrolled in this retrospective study. During bronchoscopy, pulmonary fissure integrity was evaluated with the Chartis assessment system in each patient first under spontaneous breathing and subsequently under high-frequency (HF) jet ventilation. Results: In total, 102 patients were analyzed. Four Chartis phenotypes CV positive (CV+), CV negative (CV−), low flow, and low plateau in spontaneous breathing and HF jet ventilation were identified. The frequency of each Chartis phenotype per lobe was similar in both settings. When comparing Chartis assessments in spontaneous breathing and HF jet ventilation, there was an overall good concordance rate for all analyzed fissures. In agreement, receiver operating characteristic analysis of the FCS showed an almost similar prediction for CV+ and CV− status independent of the ventilation modes. Conclusion: Chartis assessment in spontaneous breathing and HF jet ventilation had similar rates in detecting CV in lung emphysema. Our results suggest that both modes are equivalent for the assessment of CV.
- 3 December 2021
- Published by S. Karger AG in Respiration
- Vol. 101 (4) , 408-416
Impact of Ventilation Modes on Bronchoscopic Chartis Assessment Outcome in Candidates for Endobronchial Valve Treatment
Background: Endobronchial valve therapy has proven to reduce lung hyperinflation and decrease disease burden in patients with severe lung emphysema. Exclusion of collateral ventilation (CV) of the targeted lobe by using an endobronchial assessment system (Chartis; PulmonX, Drive Redwood City, CA, USA) in combination with software-based fissure integrity analysis (FCS [fissure completeness score]) of computed tomography scans of the lung are established tools to select appropriate patients for endobronchial valve treatment. So far, there is no conclusive evidence if the ventilation mode during bronchoscopy impacts the outcome of Chartis assessments. Methods: Patients with Chartis assessments and software-based quantification of FCS (StratX; PulmonX, Drive Redwood City, CA, USA) were enrolled in this retrospective study. During bronchoscopy, pulmonary fissure integrity was evaluated with the Chartis assessment system in each patient first under spontaneous breathing and subsequently under high-frequency (HF) jet ventilation. Results: In total, 102 patients were analyzed. Four Chartis phenotypes CV positive (CV+), CV negative (CV−), low flow, and low plateau in spontaneous breathing and HF jet ventilation were identified. The frequency of each Chartis phenotype per lobe was similar in both settings. When comparing Chartis assessments in spontaneous breathing and HF jet ventilation, there was an overall good concordance rate for all analyzed fissures. In agreement, receiver operating characteristic analysis of the FCS showed an almost similar prediction for CV+ and CV− status independent of the ventilation modes. Conclusion: Chartis assessment in spontaneous breathing and HF jet ventilation had similar rates in detecting CV in lung emphysema. Our results suggest that both modes are equivalent for the assessment of CV.
- Open Access
- 1 August 2020
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 15, 1877-1886
Quantitative CT Analysis in Patients with Pulmonary Emphysema: Do Calculated Differences Between Full Inspiration and Expiration Correlate with Lung Function?
Purpose: The aim of this retrospective study was to evaluate correlations between parameters of quantitative computed tomography (QCT) analysis, especially the 15th percentile of lung attenuation (P15), and parameters of clinical tests in a large group of patients with pulmonary emphysema. Patients and Methods: One hundred and seventy-two patients with pulmonary emphysema and chronic obstructive pulmonary disease (COPD) global initiative for chronic obstructive lung disease (GOLD) stage 3 or 4 were assessed by nonenhanced thin-section CT scans in full inspiratory and expiratory breath-hold, pulmonary function test (PFT), a 6-minute walk test (6MWT), and quality of life questionnaires (SGRQ and CAT). QCT parameters included total lung volume (TLV), total emphysema score (TES), and P15, all measured at inspiration (IN) and expiration (EX). Differences between inspiration and expiration were calculated for TLV (TLVDiff), TES (TESDiff), and P15 (P15Diff). Spearman correlation analysis was performed. Results: CT-measured lung volume in inspiration (TLVIN) correlated strongly with spirometry-measured total lung capacity (TLC) (r=0.81, p< 0.001) and moderately to strongly with residual volume (RV), forced vital capacity (FVC), and forced expiratory volume in 1 second (FEV1)/FVC (r=0.60, 0.56, and − 0.49, each p< 0.001). Lung volume in expiration (TLVEX) correlated moderately to strongly with TLC, RV and FEV1/FVC ratio (r=0.75, 0.66, and − 0.43, each p< 0.001). TES and P15 showed stronger correlations with the carbon monoxide transfer coefficient (KCO%) (r= − 0.42, 0.44, both p< 0.001), when measured during expiration. P15Diff correlated moderately with KCO% and carbon monoxide diffusing capacity (DLCO%) (r= 0.41, 0.40, both p< 0.001). The 6MWT and most QCT parameters showed significant differences between COPD GOLD 3 and 4 groups. Conclusion: Our results suggest that QCT can help predict the severity of lung function decrease in patients with pulmonary emphysema and COPD GOLD 3 or 4. Some QCT parameters, including P15EX and P15Diff, correlated moderately to strongly with parameters of pulmonary function tests.
- 1 August 2020
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 15, 1877-1886
Open AccessQuantitative CT Analysis in Patients with Pulmonary Emphysema: Do Calculated Differences Between Full Inspiration and Expiration Correlate with Lung Function?
Purpose: The aim of this retrospective study was to evaluate correlations between parameters of quantitative computed tomography (QCT) analysis, especially the 15th percentile of lung attenuation (P15), and parameters of clinical tests in a large group of patients with pulmonary emphysema. Patients and Methods: One hundred and seventy-two patients with pulmonary emphysema and chronic obstructive pulmonary disease (COPD) global initiative for chronic obstructive lung disease (GOLD) stage 3 or 4 were assessed by nonenhanced thin-section CT scans in full inspiratory and expiratory breath-hold, pulmonary function test (PFT), a 6-minute walk test (6MWT), and quality of life questionnaires (SGRQ and CAT). QCT parameters included total lung volume (TLV), total emphysema score (TES), and P15, all measured at inspiration (IN) and expiration (EX). Differences between inspiration and expiration were calculated for TLV (TLVDiff), TES (TESDiff), and P15 (P15Diff). Spearman correlation analysis was performed. Results: CT-measured lung volume in inspiration (TLVIN) correlated strongly with spirometry-measured total lung capacity (TLC) (r=0.81, p< 0.001) and moderately to strongly with residual volume (RV), forced vital capacity (FVC), and forced expiratory volume in 1 second (FEV1)/FVC (r=0.60, 0.56, and − 0.49, each p< 0.001). Lung volume in expiration (TLVEX) correlated moderately to strongly with TLC, RV and FEV1/FVC ratio (r=0.75, 0.66, and − 0.43, each p< 0.001). TES and P15 showed stronger correlations with the carbon monoxide transfer coefficient (KCO%) (r= − 0.42, 0.44, both p< 0.001), when measured during expiration. P15Diff correlated moderately with KCO% and carbon monoxide diffusing capacity (DLCO%) (r= 0.41, 0.40, both p< 0.001). The 6MWT and most QCT parameters showed significant differences between COPD GOLD 3 and 4 groups. Conclusion: Our results suggest that QCT can help predict the severity of lung function decrease in patients with pulmonary emphysema and COPD GOLD 3 or 4. Some QCT parameters, including P15EX and P15Diff, correlated moderately to strongly with parameters of pulmonary function tests.
- Open Access
- 1 June 2020
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 15, 1325-1334
An Integrative Approach of the Fissure Completeness Score and Chartis Assessment in Endobronchial Valve Treatment for Emphysema
Purpose: Lung volume reduction using one-way endobronchial valves is a bronchoscopic treatment for patients with severe emphysema without collateral ventilation between the treatment target lobe and the ipsilateral lobe(s). CT-scan fissure analysis is often used as a surrogate to predict the absence of collateral ventilation. We aimed to evaluate the predictive value of the fissure completeness score (FCS) compared to the functional Chartis measurement of collateral ventilation and to provide cut-off values of the FCS in patient selection. Patients and Methods: Multicenter study in patients eligible for treatment with one-way valves. The FCS was calculated by quantitative CT analysis (Thirona, the Netherlands) and compared to status of interlobar collateral ventilation measured with Chartis system (PulmonX, USA). Thresholds were calculated for the predictive values of the presence of collateral ventilation. Results: An FCS > 95% of the left major fissure had a positive predictive value (PPV) of 91%, with 1 in 11 fissures demonstrating collateral ventilation with Chartis measurement, whereas an FCS of ≤ 80% had a negative predictive value (NPV) of 100% for the presence of collateral ventilation. For the right major fissure, the NPV was 100% for an FCS ≤ 90%, but 69.7% for the right upper lobe fissure. Conclusion: Quantitative CT analysis is recommended in all patients evaluated for endobronchial valves. Patients with incomplete fissures (left major fissure: FCS < 80%; right major fissure: < 90%) can be excluded from Chartis measurement and endobronchial valve treatment. In patients with more complete fissures, the FCS is not specific enough for endobronchial valve treatment decisions. In this case, additional Chartis measurements are always recommended in the right lung. For the left lung, Chartis assessments may be omitted if the FCS is > 95%.
- 1 June 2020
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 15, 1325-1334
Open AccessAn Integrative Approach of the Fissure Completeness Score and Chartis Assessment in Endobronchial Valve Treatment for Emphysema
Purpose: Lung volume reduction using one-way endobronchial valves is a bronchoscopic treatment for patients with severe emphysema without collateral ventilation between the treatment target lobe and the ipsilateral lobe(s). CT-scan fissure analysis is often used as a surrogate to predict the absence of collateral ventilation. We aimed to evaluate the predictive value of the fissure completeness score (FCS) compared to the functional Chartis measurement of collateral ventilation and to provide cut-off values of the FCS in patient selection. Patients and Methods: Multicenter study in patients eligible for treatment with one-way valves. The FCS was calculated by quantitative CT analysis (Thirona, the Netherlands) and compared to status of interlobar collateral ventilation measured with Chartis system (PulmonX, USA). Thresholds were calculated for the predictive values of the presence of collateral ventilation. Results: An FCS > 95% of the left major fissure had a positive predictive value (PPV) of 91%, with 1 in 11 fissures demonstrating collateral ventilation with Chartis measurement, whereas an FCS of ≤ 80% had a negative predictive value (NPV) of 100% for the presence of collateral ventilation. For the right major fissure, the NPV was 100% for an FCS ≤ 90%, but 69.7% for the right upper lobe fissure. Conclusion: Quantitative CT analysis is recommended in all patients evaluated for endobronchial valves. Patients with incomplete fissures (left major fissure: FCS < 80%; right major fissure: < 90%) can be excluded from Chartis measurement and endobronchial valve treatment. In patients with more complete fissures, the FCS is not specific enough for endobronchial valve treatment decisions. In this case, additional Chartis measurements are always recommended in the right lung. For the left lung, Chartis assessments may be omitted if the FCS is > 95%.
- 31 August 2016
- Published by S. Karger AG in Respiration
- Vol. 92 (3) , 150-157
Predicting Lung Volume Reduction after Endobronchial Valve Therapy Is Maximized Using a Combination of Diagnostic Tools
Background: Bronchoscopic lung volume reduction using one-way endobronchial valves (EBVs) has been proven to be effective in patients with severe emphysema. However, the selection of patients without collateral ventilation prior to treatment is critical for procedural success. Collateral ventilation can be assessed directly with the Chartis system or indirectly using computed tomography (CT) fissure analysis. Objectives: We retrospectively evaluated the diagnostic value of a combination of the quantitative CT interlobar fissure completeness score (FCS) and Chartis in predicting responders to EBV therapy. Methods: CT data from four prospective studies were pooled and analyzed using semiautomated software to quantify the completeness of interlobar fissures. These FCSs were compared to a reference standard of achieving ≥350 ml of target lobe volume reduction after EBV treatment. Using a receiver operating characteristic curve, optimal thresholds predictive of complete fissures (responders) and incomplete fissures (non-responders) were determined. A subgroup of patients with partially complete fissures was identified, where software had lower accuracy. The complementary value of Chartis was investigated in this group. Results: A fissure was defined as complete (FCS >95%), incomplete (FCS <80%), or partially complete (80% < FCS < 95%). The positive predictive value (PPV) of complete fissures is 88.1%, and the negative predictive value (NPV) is 92.9%, with an overall accuracy of 89.2%. Chartis was utilized in patients with partially complete fissures, with a PPV of 82.3%, an NPV of 84.6%, and an accuracy of 83.3%. Conclusion: Combining diagnostic tools could reduce the burden on patients and the healthcare system while providing clinicians with a better means for patient selection for EBV therapy.
- 31 August 2016
- Published by S. Karger AG in Respiration
- Vol. 92 (3) , 150-157
Predicting Lung Volume Reduction after Endobronchial Valve Therapy Is Maximized Using a Combination of Diagnostic Tools
Background: Bronchoscopic lung volume reduction using one-way endobronchial valves (EBVs) has been proven to be effective in patients with severe emphysema. However, the selection of patients without collateral ventilation prior to treatment is critical for procedural success. Collateral ventilation can be assessed directly with the Chartis system or indirectly using computed tomography (CT) fissure analysis. Objectives: We retrospectively evaluated the diagnostic value of a combination of the quantitative CT interlobar fissure completeness score (FCS) and Chartis in predicting responders to EBV therapy. Methods: CT data from four prospective studies were pooled and analyzed using semiautomated software to quantify the completeness of interlobar fissures. These FCSs were compared to a reference standard of achieving ≥350 ml of target lobe volume reduction after EBV treatment. Using a receiver operating characteristic curve, optimal thresholds predictive of complete fissures (responders) and incomplete fissures (non-responders) were determined. A subgroup of patients with partially complete fissures was identified, where software had lower accuracy. The complementary value of Chartis was investigated in this group. Results: A fissure was defined as complete (FCS >95%), incomplete (FCS <80%), or partially complete (80% < FCS < 95%). The positive predictive value (PPV) of complete fissures is 88.1%, and the negative predictive value (NPV) is 92.9%, with an overall accuracy of 89.2%. Chartis was utilized in patients with partially complete fissures, with a PPV of 82.3%, an NPV of 84.6%, and an accuracy of 83.3%. Conclusion: Combining diagnostic tools could reduce the burden on patients and the healthcare system while providing clinicians with a better means for patient selection for EBV therapy.
- 24 December 2015
- Published by S. Karger AG in Respiration
- Vol. 91 (1) , 69-78
Outcomes of Endobronchial Valve Treatment Based on the Precise Criteria of an Endobronchial Catheter for Detection of Collateral Ventilation under Spontaneous Breathing
Background: Endoscopic lung volume reduction with valves is a valid therapeutic option for COPD patients with severe emphysema. The exclusion of interlobar collateral ventilation (CV) is an important predictor of clinical success. Objectives: Recently, a catheter-based endobronchial in vivo measurement system (Chartis, Pulmonx, USA) has become routine in the clinical evaluation of CV status in target lobes, but the criteria for phenotyping CV by Chartis evaluation have not yet been defined. We asked the questions, how many phenotypes can be identified using Chartis, what are the exact criteria to distinguish them, and how do the Chartis phenotypes respond to valve insertionκ Methods: In a retrospective study, 406 Chartis assessments of 166 patients with severe COPD were analyzed. Four Chartis phenotypes, CV positive (CV+), CV negative (CV-), low flow (LF) and low plateau were identified. Fifty-two patients without CV were treated with valves and followed for 3 months. Results: The Chartis phenotypes were discriminated with respect to decline in expiratory peak flow, increase in resistance index and change in total exhaled volume after 1, 2, 3, 4 and 5 min of measurement time (p < 0.0001, ANOVA), and the cutoff criteria were defined accordingly. To examine the application of these phenotyping criteria, students applied them to 100 Chartis assessments, and they demonstrated almost perfect inter- and intraobserver agreements (κ > 0.9). Compared to baseline, CV- and LF patients with ipsilateral CV- lobe showed an improvement in FEV1 (p < 0.05), vital capacity (p < 0.05) and target lobe volume reduction (p < 0.005) after valve insertion. Conclusion: This study describes the most prevalent Chartis phenotypes.
- 24 December 2015
- Published by S. Karger AG in Respiration
- Vol. 91 (1) , 69-78
Outcomes of Endobronchial Valve Treatment Based on the Precise Criteria of an Endobronchial Catheter for Detection of Collateral Ventilation under Spontaneous Breathing
Background: Endoscopic lung volume reduction with valves is a valid therapeutic option for COPD patients with severe emphysema. The exclusion of interlobar collateral ventilation (CV) is an important predictor of clinical success. Objectives: Recently, a catheter-based endobronchial in vivo measurement system (Chartis, Pulmonx, USA) has become routine in the clinical evaluation of CV status in target lobes, but the criteria for phenotyping CV by Chartis evaluation have not yet been defined. We asked the questions, how many phenotypes can be identified using Chartis, what are the exact criteria to distinguish them, and how do the Chartis phenotypes respond to valve insertionκ Methods: In a retrospective study, 406 Chartis assessments of 166 patients with severe COPD were analyzed. Four Chartis phenotypes, CV positive (CV+), CV negative (CV-), low flow (LF) and low plateau were identified. Fifty-two patients without CV were treated with valves and followed for 3 months. Results: The Chartis phenotypes were discriminated with respect to decline in expiratory peak flow, increase in resistance index and change in total exhaled volume after 1, 2, 3, 4 and 5 min of measurement time (p < 0.0001, ANOVA), and the cutoff criteria were defined accordingly. To examine the application of these phenotyping criteria, students applied them to 100 Chartis assessments, and they demonstrated almost perfect inter- and intraobserver agreements (κ > 0.9). Compared to baseline, CV- and LF patients with ipsilateral CV- lobe showed an improvement in FEV1 (p < 0.05), vital capacity (p < 0.05) and target lobe volume reduction (p < 0.005) after valve insertion. Conclusion: This study describes the most prevalent Chartis phenotypes.