Molla Tefera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Molla Tefera has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Atnafu Guadie
Department of Chemistry, University of Gondar, Gondar, Ethiopia
7 shared publications- Adane Kassa
Department of Chemistry, College of Natural and Computational Sciences, Debre Markos University, P.O. Box 269, Debre Markos, Ethiopia
4 shared publications Dessie Ezez
4 shared publications- Atakilt Abebe
Department of Chemistry, College of Science, Bahir Dar University, P.O.Box 79, Bahir Dar, Ethiopia
3 shared publications - Belete Asefa Aragaw
Department of Chemistry, College of Science, Bahir Dar University, P.O.Box 79, Bahir Dar, Ethiopia
3 shared publications Merid Tessema
Department of Chemistry, Addis Ababa University, P. O. Box 1176, Addis Ababa, Ethiopia
3 shared publications
Latest Publications
- Open Access
- 20 January 2026
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2026 (1)
Enhanced Detection of Organochlorine Pesticide Residues in Sesame Seeds ( Sesamum indicum L .) Using Advanced GC‐MS/MS Techniques
Considering the economic and edible values of sesame seeds, it is important to monitor sesame seed for the safety of consumers and for international trade as it helps the country government and suppliers as products to gain market acceptance more effectively. The objective of this study was to determine selected organochlorine pesticide (OCP) residues in sesame seeds. Quick, easy, cheap, efficient, rugged, and safe method followed by gas chromatography coupled with tandem mass spectrometry (GC‐MS/MS) was used for the rapid separation and determination of 20 OCPs in sesame seeds. Acetonitrile in combination with 1% glacial acetic acid was used as an extraction solvent. Primary secondary amine, graphitized carbon black, and octadecylsilane in QuEChERS kit were used for d‐SPE clean up before GC‐MS/MS analysis. The GC‐MS/MS analysis was evaluated in terms of linearity, recovery, and precision. The calibration curves were obtained for all analytes and displayed good linearity over the selected concentration range with regression coefficients ( r 2 ) ≥ 0.999. The recoveries for spiked analytes in sesame seed samples were ranged from 93.58 to 115.81 with RSDs lower than 1%. The LOD and LOQ for all investigated pesticides were in the range of 0.05–0.88 μg/kg and from 0.16 to 2.93 μg/kg, respectively.
- 20 January 2026
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2026 (1)
Open AccessEnhanced Detection of Organochlorine Pesticide Residues in Sesame Seeds ( Sesamum indicum L .) Using Advanced GC‐MS/MS Techniques
Considering the economic and edible values of sesame seeds, it is important to monitor sesame seed for the safety of consumers and for international trade as it helps the country government and suppliers as products to gain market acceptance more effectively. The objective of this study was to determine selected organochlorine pesticide (OCP) residues in sesame seeds. Quick, easy, cheap, efficient, rugged, and safe method followed by gas chromatography coupled with tandem mass spectrometry (GC‐MS/MS) was used for the rapid separation and determination of 20 OCPs in sesame seeds. Acetonitrile in combination with 1% glacial acetic acid was used as an extraction solvent. Primary secondary amine, graphitized carbon black, and octadecylsilane in QuEChERS kit were used for d‐SPE clean up before GC‐MS/MS analysis. The GC‐MS/MS analysis was evaluated in terms of linearity, recovery, and precision. The calibration curves were obtained for all analytes and displayed good linearity over the selected concentration range with regression coefficients ( r 2 ) ≥ 0.999. The recoveries for spiked analytes in sesame seed samples were ranged from 93.58 to 115.81 with RSDs lower than 1%. The LOD and LOQ for all investigated pesticides were in the range of 0.05–0.88 μg/kg and from 0.16 to 2.93 μg/kg, respectively.
- Open Access
- 8 October 2025
- Published by Taylor & Francis in Cogent Food & Agriculture
- Vol. 11 (1)
Heavy metal analysis, nutritional values and polyphenol levels of indigenous onion cultivars from Ethiopia: variability implication for its health concerns
- 8 October 2025
- Published by Taylor & Francis in Cogent Food & Agriculture
- Vol. 11 (1)
Open AccessHeavy metal analysis, nutritional values and polyphenol levels of indigenous onion cultivars from Ethiopia: variability implication for its health concerns
- Open Access
- 23 July 2025
- Published by Springer Nature in Food Safety and Risk
- Vol. 12 (1) , 1-12
Evaluating the contamination of soil, water and vegetables with heavy metals along with the estimation of transfer factor and human health risk in Gondar city, Ethiopia
- 23 July 2025
- Published by Springer Nature in Food Safety and Risk
- Vol. 12 (1) , 1-12
Open AccessEvaluating the contamination of soil, water and vegetables with heavy metals along with the estimation of transfer factor and human health risk in Gondar city, Ethiopia
- Open Access
- 8 July 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (28) , 29929-29949
A Review of Voltammetric Techniques for Sensitive Detection of Organophosphate Pesticides in Environmental Samples
This review looks closely at new developments in voltammetric techniques for detecting organophosphate pesticides (OPPs) in environmental samples. OPPs are commonly used in farming but can be harmful to human health and the environment due to their toxicity and long-lasting effects. The review explores different electrochemical sensors, such as enzyme-based biosensors, metal oxide electrodes, and systems using nanomaterials, which have improved the sensitivity and selectivity for detecting OPPs. It highlights key innovations like hybrid enzyme-inorganic nanoflowers and modified graphene electrodes for their excellent performance, achieving low detection limits and quick response times. The use of nanomaterials, such as carbon nanotubes and gold nanoparticles, enhances the sensors’ electrochemical properties, allowing for real-time monitoring of pesticide residues. The review also addresses challenges in accurately analyzing OPPs and stresses the need for portable, user-friendly devices for on-site testing. The importance of these technological advancements for food safety and environmental monitoring is emphasized, highlighting the crucial role of reliable detection methods in reducing health risks from pesticide exposure. This review is a useful resource for researchers and practitioners, providing insights into current methods and future developments in effective sensing technologies for organophosphate pesticides.
- 8 July 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (28) , 29929-29949
Open AccessA Review of Voltammetric Techniques for Sensitive Detection of Organophosphate Pesticides in Environmental Samples
This review looks closely at new developments in voltammetric techniques for detecting organophosphate pesticides (OPPs) in environmental samples. OPPs are commonly used in farming but can be harmful to human health and the environment due to their toxicity and long-lasting effects. The review explores different electrochemical sensors, such as enzyme-based biosensors, metal oxide electrodes, and systems using nanomaterials, which have improved the sensitivity and selectivity for detecting OPPs. It highlights key innovations like hybrid enzyme-inorganic nanoflowers and modified graphene electrodes for their excellent performance, achieving low detection limits and quick response times. The use of nanomaterials, such as carbon nanotubes and gold nanoparticles, enhances the sensors’ electrochemical properties, allowing for real-time monitoring of pesticide residues. The review also addresses challenges in accurately analyzing OPPs and stresses the need for portable, user-friendly devices for on-site testing. The importance of these technological advancements for food safety and environmental monitoring is emphasized, highlighting the crucial role of reliable detection methods in reducing health risks from pesticide exposure. This review is a useful resource for researchers and practitioners, providing insights into current methods and future developments in effective sensing technologies for organophosphate pesticides.
- Open Access
- 5 February 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (6) , 5601-5615
Bilayered Film Modified Glassy Carbon Electrode for the Simultaneous Determination of Paracetamol and Chloroquine in Pharmaceutical and Biological Samples
A new, cost-effective selective and highly sensitive electrochemical sensor (poly(cobalt(II) bis(1,10-phenanthroline) and copper(I) bis(2,2-bipyrdine)), poly(Co(Phen)2/Cu(Bip)2)/GCE) was synthesized based on the sequential electropolymerization of diaquabis(1,10-phenanthroline) cobalt(II)iodide dehydrate ([Co(Phen)2(H2O)2]I2·2H2O) and bis(2,2'-bipyridine)hydroxyl copper(II) iodide ([Cu(Bip)2OH]I) at a glassy carbon electrode. The established sensor (poly(Co(Phen)2/Cu(Bip)2)/GCE)) was employed for the simultaneous electrochemical determination of paracetamol (PCM) and chloroquine (CQ). The established sensor was characterized by FTIR, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The electrochemical performance of unmodified GCE and poly(Co(Phen)2/Cu(Bip)2)/GCE was evaluated for the simultaneous voltammetric determination of PCM and CQ. Using poly(Co(Phen)2/Cu(Bip)2)/GCE and optimized conditions, the simultaneous square wave voltammetric determination of PCM and CQ shows linearity in the concentration range between 0.5 and 200 μM, with sensitivity of 0.389 and 0.462 μA/μM and detection limits (LOD) of (3δ/m) 4.38 × 10-2 and 7.48 × 10-2 μM, respectively. Poly(Co(Phen)2/Cu(Bip)2)/GCE showed excellent performance for the simultaneous sensing of PCM and CQ in pharmaceutical, serum, and urine samples, with spiked recoveries exceeding 98.9, 97.9, and 98.2%, respectively, demonstrating low LOD, excellent sensitivity, admirable selectivity, venerable repeatability, and long-lasting stability. Poly(Co(Phen)2/Cu(Bip)2)/GCE's selectivity for the simultaneous determination of PCM and CQ was shown, demonstrating excellent selectivity despite potential interferences like sulfamethoxazole (SMX), salbutamol (SBM), guanine (Gua), and atorvastatin (ATS). These results designate that poly(Co(Phen)2/Cu(Bip)2)/GCE exhibits admirable applicability for the simultaneous electrochemical sensing of PCM and CQ in various real samples.
- 5 February 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (6) , 5601-5615
Open AccessBilayered Film Modified Glassy Carbon Electrode for the Simultaneous Determination of Paracetamol and Chloroquine in Pharmaceutical and Biological Samples
A new, cost-effective selective and highly sensitive electrochemical sensor (poly(cobalt(II) bis(1,10-phenanthroline) and copper(I) bis(2,2-bipyrdine)), poly(Co(Phen)2/Cu(Bip)2)/GCE) was synthesized based on the sequential electropolymerization of diaquabis(1,10-phenanthroline) cobalt(II)iodide dehydrate ([Co(Phen)2(H2O)2]I2·2H2O) and bis(2,2'-bipyridine)hydroxyl copper(II) iodide ([Cu(Bip)2OH]I) at a glassy carbon electrode. The established sensor (poly(Co(Phen)2/Cu(Bip)2)/GCE)) was employed for the simultaneous electrochemical determination of paracetamol (PCM) and chloroquine (CQ). The established sensor was characterized by FTIR, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The electrochemical performance of unmodified GCE and poly(Co(Phen)2/Cu(Bip)2)/GCE was evaluated for the simultaneous voltammetric determination of PCM and CQ. Using poly(Co(Phen)2/Cu(Bip)2)/GCE and optimized conditions, the simultaneous square wave voltammetric determination of PCM and CQ shows linearity in the concentration range between 0.5 and 200 μM, with sensitivity of 0.389 and 0.462 μA/μM and detection limits (LOD) of (3δ/m) 4.38 × 10-2 and 7.48 × 10-2 μM, respectively. Poly(Co(Phen)2/Cu(Bip)2)/GCE showed excellent performance for the simultaneous sensing of PCM and CQ in pharmaceutical, serum, and urine samples, with spiked recoveries exceeding 98.9, 97.9, and 98.2%, respectively, demonstrating low LOD, excellent sensitivity, admirable selectivity, venerable repeatability, and long-lasting stability. Poly(Co(Phen)2/Cu(Bip)2)/GCE's selectivity for the simultaneous determination of PCM and CQ was shown, demonstrating excellent selectivity despite potential interferences like sulfamethoxazole (SMX), salbutamol (SBM), guanine (Gua), and atorvastatin (ATS). These results designate that poly(Co(Phen)2/Cu(Bip)2)/GCE exhibits admirable applicability for the simultaneous electrochemical sensing of PCM and CQ in various real samples.
- Open Access
- 10 July 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (29) , 25758-25765
Selective Determination of Norfloxacin in Pharmaceutical Formulations and Human Urine Samples Using Poly(8-aminonaphthaline-2-sulfonic Acid)-Modified Glassy Carbon Electrodes
In this study, a glassy carbon electrode was modified potentiodynamically with poly(8-aminonaphthaline-2-sulfonic acid) [poly(ANSA)/GCE] for the detection of norfloxacin (NFN) in tablet formulations and human urine samples. Improvement of the effective surface area of the modified electrode and decreased charge-transfer resistance confirmed surface modification of the GCE by a conductive poly(ANSA) film. The appearance of an oxidative peak without a reductive peak in the reverse scan direction showed the irreversibility of the electrochemical oxidation of NFN in both the bare GCE and poly(ANSA)/GCE. A better coefficient of determination for the peak current on the square root of the scan rate (R2 = 0.99514) than the scan rate (R2 = 0.97109), indicating the oxidation of NFN at the poly(ANSA)/GCE, was predominantly diffusion mass transport-controlled. Under optimized pH and square wave parameters, the voltammetric current response of NFN at the poly(ANSA)/GCE showed linear dependence on the concentration, ranging from 1.0 × 10-8 to 4.0 × 10-4 M with a limit of detection of 4.1 × 10-10. The NFN level in the studied tablet brands was in the range of 90.30-103.3% of their labeled values. Recovery results in tablet and urine samples ranged from 98.35 to 101.20% and 97.75 to 99.60%, respectively, and interference recovery results were less than 2.13% error in the presence of ampicillin, chloroquine phosphate, and cloxacillin. The present method had a better performance for the determination of NFN in tablet formulations and urine samples as compared with recently reported voltammetric methods due to its requirement of a simple electrode modification step, which provides the least limit of detection and a reasonably wider linear dynamic range.
- 10 July 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (29) , 25758-25765
Open AccessSelective Determination of Norfloxacin in Pharmaceutical Formulations and Human Urine Samples Using Poly(8-aminonaphthaline-2-sulfonic Acid)-Modified Glassy Carbon Electrodes
In this study, a glassy carbon electrode was modified potentiodynamically with poly(8-aminonaphthaline-2-sulfonic acid) [poly(ANSA)/GCE] for the detection of norfloxacin (NFN) in tablet formulations and human urine samples. Improvement of the effective surface area of the modified electrode and decreased charge-transfer resistance confirmed surface modification of the GCE by a conductive poly(ANSA) film. The appearance of an oxidative peak without a reductive peak in the reverse scan direction showed the irreversibility of the electrochemical oxidation of NFN in both the bare GCE and poly(ANSA)/GCE. A better coefficient of determination for the peak current on the square root of the scan rate (R2 = 0.99514) than the scan rate (R2 = 0.97109), indicating the oxidation of NFN at the poly(ANSA)/GCE, was predominantly diffusion mass transport-controlled. Under optimized pH and square wave parameters, the voltammetric current response of NFN at the poly(ANSA)/GCE showed linear dependence on the concentration, ranging from 1.0 × 10-8 to 4.0 × 10-4 M with a limit of detection of 4.1 × 10-10. The NFN level in the studied tablet brands was in the range of 90.30-103.3% of their labeled values. Recovery results in tablet and urine samples ranged from 98.35 to 101.20% and 97.75 to 99.60%, respectively, and interference recovery results were less than 2.13% error in the presence of ampicillin, chloroquine phosphate, and cloxacillin. The present method had a better performance for the determination of NFN in tablet formulations and urine samples as compared with recently reported voltammetric methods due to its requirement of a simple electrode modification step, which provides the least limit of detection and a reasonably wider linear dynamic range.
- Open Access
- 23 March 2023
- Published by Springer Nature in Applied Water Science
- Vol. 13 (4) , 1-12
Evaluation of water quality of Angereb reservoir: a chemometrics approach
Deterioration of water quality of lakes and reservoirs has become major global concerns that impose serious environmental impacts for both aquatic and terrestrial environments. In the current study, many parameters like temperature (Temp), electric conductivity (EC), dissolved oxygen (DO), turbidity (TU), pH, biological oxygen demand (BOD), chemical oxygen demand (COD), total alkalinity (TA), total dissolved solids (TDS), total organic carbon (TOC), nitrate(NO3−), phosphate (PO43−) and chlorophyll a (chl-a) were determined. The study covered the Angereb reservoir and its tributaries on a monthly basis from January to March 2019 at five sampling stations in accordance with APHA 2017 guide lines for physicochemical analysis. The values of all the investigated parameters, except DO (at AU, AD, KU and KD), COD and TU, were below the maximum permissible limits set by WHO. Thus, the findings for DO, TU and COD demonstrated that remedial actions should be taken to improve the quality of the water in the reservoir and its tributaries. Multivariate statistical methods (PCA and CA) were applied to detect spatial and temporal variations of water quality parameter. The first three principal components were enough to develop the PCA score plot which explained about 71.32% of the total variance in the dataset. The PCA and CA have provided similar information; grouped the 24 samples into 3 significant clusters showing spatial variations but minimal temporal variations were observed within the samples collected in the period of January in the reservoir site. The water quality parameters, TU and BOD, were moderately positively loaded on the space of the first principal component and were found to be associated with each other, whereas the EC and TDS have shown moderate negative loading and positively associated with each other. This study suggested PCA and CA methods found to be useful tools for monitoring and controlling water quality parameters for selected sampling stations of surface water.
- 23 March 2023
- Published by Springer Nature in Applied Water Science
- Vol. 13 (4) , 1-12
Open AccessEvaluation of water quality of Angereb reservoir: a chemometrics approach
Deterioration of water quality of lakes and reservoirs has become major global concerns that impose serious environmental impacts for both aquatic and terrestrial environments. In the current study, many parameters like temperature (Temp), electric conductivity (EC), dissolved oxygen (DO), turbidity (TU), pH, biological oxygen demand (BOD), chemical oxygen demand (COD), total alkalinity (TA), total dissolved solids (TDS), total organic carbon (TOC), nitrate(NO3−), phosphate (PO43−) and chlorophyll a (chl-a) were determined. The study covered the Angereb reservoir and its tributaries on a monthly basis from January to March 2019 at five sampling stations in accordance with APHA 2017 guide lines for physicochemical analysis. The values of all the investigated parameters, except DO (at AU, AD, KU and KD), COD and TU, were below the maximum permissible limits set by WHO. Thus, the findings for DO, TU and COD demonstrated that remedial actions should be taken to improve the quality of the water in the reservoir and its tributaries. Multivariate statistical methods (PCA and CA) were applied to detect spatial and temporal variations of water quality parameter. The first three principal components were enough to develop the PCA score plot which explained about 71.32% of the total variance in the dataset. The PCA and CA have provided similar information; grouped the 24 samples into 3 significant clusters showing spatial variations but minimal temporal variations were observed within the samples collected in the period of January in the reservoir site. The water quality parameters, TU and BOD, were moderately positively loaded on the space of the first principal component and were found to be associated with each other, whereas the EC and TDS have shown moderate negative loading and positively associated with each other. This study suggested PCA and CA methods found to be useful tools for monitoring and controlling water quality parameters for selected sampling stations of surface water.
- 15 February 2023
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 118
Occurrence and accumulation of metals in lupine seeds in Ethiopia
- 15 February 2023
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 118
Occurrence and accumulation of metals in lupine seeds in Ethiopia
- Open Access
- 3 February 2023
- Published by Taylor & Francis in International Journal of Food Properties
- Vol. 26 (1) , 581-590
Phytochemical analysis of Withania somnifera leaf extracts by GC-MS and evaluating antioxidants and antibacterial activities
Many people in developing countries mainly depend on medicinal plants like Withania somnifera and their products for healthcare. In this study, reflux and maceration extraction methods were applied to investigate total phenolic (TPC) and flavonoid contents (TFC); and antioxidant properties of Withania somnifera extracts toward DPPH and hydrogen peroxide (H2O2) were studied. Highest TPC was detected with methanol extracts with value of 198.24 ± 1.16 mg GAE/g and TFC of 31.52 ± 0.91 mg QE/g. The minimum amount of TPC was observed in aqueous extract (101.41 ± 1.07 mg GAE/g) and the TFC in ethyl acetate extract 9.72 ± 1.32 mg QE/g. The maximum value of DPPH radical scavenging was estimated in maceration methanol extract 81.98 ± 0.49% and value of H2O2 was obtained in maceration acetone extract 76.18 ± 1.06%. The major identified molecules were Heptasiloxane,1,1,3,3,5,5,7,7,9,9,11,11,13,13-tetradecamethyl-(50.04%), and trans-2,4 Dimethylthiane, S, S- dioxide (4.09%) The broad spectrum of antibacterial activity was observed in Escherichia coli reflux methanol extract. In both extraction techniques methanol was the best extracting solvent for phenolic and flavonoid contents as antioxidants as well as antibacterial activities.
- 3 February 2023
- Published by Taylor & Francis in International Journal of Food Properties
- Vol. 26 (1) , 581-590
Open AccessPhytochemical analysis of Withania somnifera leaf extracts by GC-MS and evaluating antioxidants and antibacterial activities
Many people in developing countries mainly depend on medicinal plants like Withania somnifera and their products for healthcare. In this study, reflux and maceration extraction methods were applied to investigate total phenolic (TPC) and flavonoid contents (TFC); and antioxidant properties of Withania somnifera extracts toward DPPH and hydrogen peroxide (H2O2) were studied. Highest TPC was detected with methanol extracts with value of 198.24 ± 1.16 mg GAE/g and TFC of 31.52 ± 0.91 mg QE/g. The minimum amount of TPC was observed in aqueous extract (101.41 ± 1.07 mg GAE/g) and the TFC in ethyl acetate extract 9.72 ± 1.32 mg QE/g. The maximum value of DPPH radical scavenging was estimated in maceration methanol extract 81.98 ± 0.49% and value of H2O2 was obtained in maceration acetone extract 76.18 ± 1.06%. The major identified molecules were Heptasiloxane,1,1,3,3,5,5,7,7,9,9,11,11,13,13-tetradecamethyl-(50.04%), and trans-2,4 Dimethylthiane, S, S- dioxide (4.09%) The broad spectrum of antibacterial activity was observed in Escherichia coli reflux methanol extract. In both extraction techniques methanol was the best extracting solvent for phenolic and flavonoid contents as antioxidants as well as antibacterial activities.