Chengli Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chengli Li has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Yujun Xu
Department of Interventional MRI Shandong Provincial Hospital, Shandong First Medical University, Jinan, China
8 shared publicationsMing Liu
Department of Interventional MRI Shandong Provincial Hospital, Shandong First Medical University, Jinan, China
7 shared publicationsXiangmeng He
Department of Interventional MRI Shandong Provincial Hospital, Shandong First Medical University, Jinan, China
7 shared publicationsLigang Wang
Department of Medical Imaging and Interventional Radiology, Affiliated Yantai Yuhuangding Hospital of Qingdao University, Yantai, Shandong, People's Republic of China
6 shared publicationsChao Liu
Department of Tumor Minimally Invasive, Tai'an Central Hospital, Tai'an, Shandong, People's Republic of China
5 shared publicationsKai Zhang
Department of Ultrasound, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
4 shared publications
Latest Publications
- 27 October 2023
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 196 (7) , 4088-4104
A Comparative Study of Antitumor Immunity Induced by Radiofrequency Microwave and Cryoablation in Hepatocellular Carcinoma
Purpose This study aimed to compare the immune responses induced by microwave ablation (MWA), radiofrequency ablation (RFA), and cryoablation (CRYO) in hepatocellular carcinoma (HCC) and identify differences in immune responses and the timing of immune changes. Materials and Methods A bilateral subcutaneous model was established in C57 mice, and the successfully modeled mice were divided into the microwave (n = 15), radiofrequency (n = 15), CRYO (n = 15), control (n = 9), and blank groups (n = 3). Mice in the control group were dissected before ablation, whereas mice in the three ablation groups underwent ultrasound-guided ablation of one axillary tumor. Three mice were sacrificed and dissected at 1–4 weeks after ablation. After tissue processing, flow cytometry was used to detect the levels of CD8 + T and regulatory T (Treg) cells in the tissue, and western blotting was used to assess the level of programmed cell death ligand 1 (PD-L1) protein in the tumor tissue. Results The pattern of immune changes after the three types of ablation was consistent, with immune changes occurring at 3–4 weeks. CRYO induced the most significant increase in the percentage of CD8 + T cells. There were no significant differences in the levels of Treg cells and the level of PD-L1 protein among the three types of ablation (p > 0.05), but the decline in Treg cells and PD-L1 protein level caused by CRYO was the most pronounced. Conclusion In the HCC mouse model, the immune changes following the three types of ablation were consistent, with immune changes occurring at 3–4 weeks. Among them, CRYO elicited the strongest adaptive immune response, and RFA outperformed MWA.
- 27 October 2023
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 196 (7) , 4088-4104
A Comparative Study of Antitumor Immunity Induced by Radiofrequency Microwave and Cryoablation in Hepatocellular Carcinoma
Purpose This study aimed to compare the immune responses induced by microwave ablation (MWA), radiofrequency ablation (RFA), and cryoablation (CRYO) in hepatocellular carcinoma (HCC) and identify differences in immune responses and the timing of immune changes. Materials and Methods A bilateral subcutaneous model was established in C57 mice, and the successfully modeled mice were divided into the microwave (n = 15), radiofrequency (n = 15), CRYO (n = 15), control (n = 9), and blank groups (n = 3). Mice in the control group were dissected before ablation, whereas mice in the three ablation groups underwent ultrasound-guided ablation of one axillary tumor. Three mice were sacrificed and dissected at 1–4 weeks after ablation. After tissue processing, flow cytometry was used to detect the levels of CD8 + T and regulatory T (Treg) cells in the tissue, and western blotting was used to assess the level of programmed cell death ligand 1 (PD-L1) protein in the tumor tissue. Results The pattern of immune changes after the three types of ablation was consistent, with immune changes occurring at 3–4 weeks. CRYO induced the most significant increase in the percentage of CD8 + T cells. There were no significant differences in the levels of Treg cells and the level of PD-L1 protein among the three types of ablation (p > 0.05), but the decline in Treg cells and PD-L1 protein level caused by CRYO was the most pronounced. Conclusion In the HCC mouse model, the immune changes following the three types of ablation were consistent, with immune changes occurring at 3–4 weeks. Among them, CRYO elicited the strongest adaptive immune response, and RFA outperformed MWA.
- Open Access
- 1 January 2023
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 15 (3) , 174-183
Three-dimensional template combined with MR-guided iodine-125 brachytherapy for recurrent brain metastases
Purpose: Treatment of recurrent brain metastases is extremely challenging. Here, we evaluated the feasibility and efficacy of an individualized three-dimensional template combined with MR-guided iodine-125 ( 125 I) brachytherapy in the treatment of recurrent brain metastases. Material and...
- 1 January 2023
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 15 (3) , 174-183
Open AccessThree-dimensional template combined with MR-guided iodine-125 brachytherapy for recurrent brain metastases
Purpose: Treatment of recurrent brain metastases is extremely challenging. Here, we evaluated the feasibility and efficacy of an individualized three-dimensional template combined with MR-guided iodine-125 ( 125 I) brachytherapy in the treatment of recurrent brain metastases. Material and...
- Open Access
- 8 June 2020
- Published by Springer Nature in Radiation Oncology
- Vol. 15 (1) , 1-10
A novel three-dimensional template combined with MR-guided 125I brachytherapy for recurrent glioblastoma
Background: At present, the treatment of recurrent glioblastoma is extremely challenging. In this study, we used a novel three-dimensional non-coplanar template (3DNPT) combined with open MR to guide 125I seed implantation for recurrent glioblastoma. The aim of this study was to evaluate the feasibility, accuracy, and effectiveness of this technique. Methods: Twenty-four patients of recurrent glioblastoma underwent 3DNPT with open MR-guided 125I brachytherapy from August 2017 to January 2019. Preoperative treatment plan and 3DNPT were made according to enhanced isovoxel T1-weighted MR images. 125I seeds were implanted using 3DNPT and 1.0-T open MR imaging guidance. Dosimetry verification was performed after brachytherapy based on postoperative CT/MR fusion images. Preoperative and postoperative dosimetry parameters of D90, V100, V200, conformity index (CI), external index (EI) were compared. The objective response rate (ORR) at 6 months and 1-year survival rate were calculated. Median overall survival (OS) measured from the date of brachytherapy was estimated by Kaplan-Meier method. Results: There were no significant differences between preoperative and postoperative dosimetry parameters of D90, V100, V200, CI, EI (P > 0.05). The ORR at 6 months was 75.0%. The 1-year survival rate was 58.3%. Median OS was 12.9 months. One case of small amount of epidural hemorrhage occurred during the procedure. There were 3 cases of symptomatic brain edema after brachytherapy treatment, including grade three toxicity in 1 case and grade two toxicity in 2 cases. The three patients were treated with corticosteroid for 2 to 4 weeks. The clinical symptoms related to brain edema were significantly alleviated thereafter. Conclusions: 3DNPT combined with open MR-guided 125I brachytherapy for circumscribed recurrent glioblastoma is feasible, effective, and with low risk of complications. Postoperative dosimetry matched the preoperative treatment plan. The described method can be used as a novel implantation technique for 125I brachytherapy in the treatment of recurrent gliomas. Trial registration: The study was approved by the Institutional Review Board of Shandong Provincial Hospital Affiliated to Shandong University (NSFC:NO.2017–058), registered 1st July 2017.
- 8 June 2020
- Published by Springer Nature in Radiation Oncology
- Vol. 15 (1) , 1-10
Open AccessA novel three-dimensional template combined with MR-guided 125I brachytherapy for recurrent glioblastoma
Background: At present, the treatment of recurrent glioblastoma is extremely challenging. In this study, we used a novel three-dimensional non-coplanar template (3DNPT) combined with open MR to guide 125I seed implantation for recurrent glioblastoma. The aim of this study was to evaluate the feasibility, accuracy, and effectiveness of this technique. Methods: Twenty-four patients of recurrent glioblastoma underwent 3DNPT with open MR-guided 125I brachytherapy from August 2017 to January 2019. Preoperative treatment plan and 3DNPT were made according to enhanced isovoxel T1-weighted MR images. 125I seeds were implanted using 3DNPT and 1.0-T open MR imaging guidance. Dosimetry verification was performed after brachytherapy based on postoperative CT/MR fusion images. Preoperative and postoperative dosimetry parameters of D90, V100, V200, conformity index (CI), external index (EI) were compared. The objective response rate (ORR) at 6 months and 1-year survival rate were calculated. Median overall survival (OS) measured from the date of brachytherapy was estimated by Kaplan-Meier method. Results: There were no significant differences between preoperative and postoperative dosimetry parameters of D90, V100, V200, CI, EI (P > 0.05). The ORR at 6 months was 75.0%. The 1-year survival rate was 58.3%. Median OS was 12.9 months. One case of small amount of epidural hemorrhage occurred during the procedure. There were 3 cases of symptomatic brain edema after brachytherapy treatment, including grade three toxicity in 1 case and grade two toxicity in 2 cases. The three patients were treated with corticosteroid for 2 to 4 weeks. The clinical symptoms related to brain edema were significantly alleviated thereafter. Conclusions: 3DNPT combined with open MR-guided 125I brachytherapy for circumscribed recurrent glioblastoma is feasible, effective, and with low risk of complications. Postoperative dosimetry matched the preoperative treatment plan. The described method can be used as a novel implantation technique for 125I brachytherapy in the treatment of recurrent gliomas. Trial registration: The study was approved by the Institutional Review Board of Shandong Provincial Hospital Affiliated to Shandong University (NSFC:NO.2017–058), registered 1st July 2017.
- 1 January 2020
- Published by Medknow in Journal of Cancer Research and Therapeutics
- Vol. 16 (7) , 1625-1633
Multiparametric magnetic resonance-guided and monitored microwave ablation in liver cancer
Atocellular carcinoma, 34 – recurrent hepatocellular carcinoma, and 10 – metastatic liver cancers) in 45 patients were treated with MWA ablation using MR guidance and monitoring. The mean diameter of the liver lesions was 1.7 ± 0.9 cm (range, 0.5–4.6 cm). The 56 liver lesions were divided into 3 groups according to diameter: the 2.0 cm group (20 lesions). Technical success, technical effectiveness, local tumor progression, procedure duration, and complications were assessed. Primary technical effectiveness was assessed 3 months after the MWA, while local tumor progression was assessed more than 3 months after the MWA. The follow-up time for assessment of treatment response ranged from 12 to 30 months (median, 23 months). Results: The technical success rate was 100%. Primary technical effectiveness was achieved in 52/56 (92.8%) lesions. Local tumor progression was detected in three tumors after initial technical effectiveness. The median duration of the intervention per tumor was 66 min (range, 40–156 min). There were no significant differences between lesion groups in the technical success rate, primary technical effectiveness rate, or local tumor progression rate. There were no major complications following the ablation therapy. Conclusions: 1.0T open multiparametric MR-guided and MR-monitored MWA for liver cancer is safe and feasible and decreases the risk of local tumor progression; it also provides good primary technique effectiveness rates and is especially suitable when ultrasound and CT facilitated treatments are inappropriate....
- 1 January 2020
- Published by Medknow in Journal of Cancer Research and Therapeutics
- Vol. 16 (7) , 1625-1633
Multiparametric magnetic resonance-guided and monitored microwave ablation in liver cancer
Atocellular carcinoma, 34 – recurrent hepatocellular carcinoma, and 10 – metastatic liver cancers) in 45 patients were treated with MWA ablation using MR guidance and monitoring. The mean diameter of the liver lesions was 1.7 ± 0.9 cm (range, 0.5–4.6 cm). The 56 liver lesions were divided into 3 groups according to diameter: the 2.0 cm group (20 lesions). Technical success, technical effectiveness, local tumor progression, procedure duration, and complications were assessed. Primary technical effectiveness was assessed 3 months after the MWA, while local tumor progression was assessed more than 3 months after the MWA. The follow-up time for assessment of treatment response ranged from 12 to 30 months (median, 23 months). Results: The technical success rate was 100%. Primary technical effectiveness was achieved in 52/56 (92.8%) lesions. Local tumor progression was detected in three tumors after initial technical effectiveness. The median duration of the intervention per tumor was 66 min (range, 40–156 min). There were no significant differences between lesion groups in the technical success rate, primary technical effectiveness rate, or local tumor progression rate. There were no major complications following the ablation therapy. Conclusions: 1.0T open multiparametric MR-guided and MR-monitored MWA for liver cancer is safe and feasible and decreases the risk of local tumor progression; it also provides good primary technique effectiveness rates and is especially suitable when ultrasound and CT facilitated treatments are inappropriate....
- 1 June 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 212 (6) , 1361-1369
MRI-Guided Cryoablation of Hepatic Dome Hepatocellular Carcinomas Using 1-T Open High-Field-Strength Scanner
OBJECTIVE. The objective of our study was to prospectively evaluate the feasibility, safety, and effectiveness of 1-T open MRI-guided percutaneous cryoablation of hepatic dome hepatocellular carcinomas (HCCs). SUBJECTS AND METHODS. Thirty-seven patients with 37 hepatic dome HCCs underwent MRI-guided percutaneous cryoablations. MR fluoroscopy with a freehand technique was applied in the procedure. All lesions ranged in size from 8 to 38 mm. Patients were followed for at least 12 months after cryoablation or until death. Survival period, local tumor control, and complications were recorded. RESULTS. MRI-guided percutaneous cryoablation procedures were successfully performed on all 37 lesions. The technical success rate was 100%. The median follow-up time was 21.0 months (range, 10–26 months). Two patients with local tumor progression at the 4th and 11th month after the procedure were treated with a supplementary cryoablation. One patient died of upper gastrointestinal hemorrhage at the 10th month after cryo...
- 1 June 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 212 (6) , 1361-1369
MRI-Guided Cryoablation of Hepatic Dome Hepatocellular Carcinomas Using 1-T Open High-Field-Strength Scanner
OBJECTIVE. The objective of our study was to prospectively evaluate the feasibility, safety, and effectiveness of 1-T open MRI-guided percutaneous cryoablation of hepatic dome hepatocellular carcinomas (HCCs). SUBJECTS AND METHODS. Thirty-seven patients with 37 hepatic dome HCCs underwent MRI-guided percutaneous cryoablations. MR fluoroscopy with a freehand technique was applied in the procedure. All lesions ranged in size from 8 to 38 mm. Patients were followed for at least 12 months after cryoablation or until death. Survival period, local tumor control, and complications were recorded. RESULTS. MRI-guided percutaneous cryoablation procedures were successfully performed on all 37 lesions. The technical success rate was 100%. The median follow-up time was 21.0 months (range, 10–26 months). Two patients with local tumor progression at the 4th and 11th month after the procedure were treated with a supplementary cryoablation. One patient died of upper gastrointestinal hemorrhage at the 10th month after cryo...
- 12 June 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (1) , 85-92
Real-time MR-guided brain biopsy using 1.0-T open MRI scanner
Objectives To evaluate the safety, feasibility and diagnostic performance of real-time MR-guided brain biopsy using a 1.0-T open MRI scanner. Methods Medical records of 86 consecutive participants who underwent brain biopsy under the guidance of a 1.0-T open MRI scanner with real-time and MR fluoroscopy techniques were evaluated retrospectively. All procedures were performed under local anaesthesia and intravenous conscious sedation. Diagnostic yield, diagnostic accuracy, complication rate and procedure duration were assessed. The lesions were divided into two groups according to maximum diameters: ≤ 1.5 cm (n = 16) and > 1.5 cm (n = 70). The two groups were compared using Fisher’s exact test. Results Diagnostic yield and diagnostic accuracy were 95.3% and 94.2%, respectively. The diagnostic yield of lesions ≤ 1.5 cm and > 1.5 cm were 93.8% and 95.7%, respectively. There was no significant difference in diagnostic yield between the two groups (p > 0.05). Mean procedure duration was 41 ± 5 min (range 33–49 min). All biopsy needles were placed with one pass. Complication rate was 3.5% (3/86). Minor complications included three cases of a small amount of haemorrhage. No serious complications were observed. Conclusions Real-time MR-guided brain biopsy using a 1.0-T open MRI scanner is a safe, feasible and accurate diagnostic technique for pathological diagnosis of brain lesions. The procedure duration is shortened and biopsy work flow is simplified. It could be considered as an alternative for brain biopsy. Key Points • Real-time MRI-guided brain biopsy using a 1.0-T open MRI scanner is safe, feasible and accurate. • No serious complications occurred in real-time MRI-guided brain biopsy. • Procedure duration is shortened and biopsy work flow is simplified.
- 12 June 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (1) , 85-92
Real-time MR-guided brain biopsy using 1.0-T open MRI scanner
Objectives To evaluate the safety, feasibility and diagnostic performance of real-time MR-guided brain biopsy using a 1.0-T open MRI scanner. Methods Medical records of 86 consecutive participants who underwent brain biopsy under the guidance of a 1.0-T open MRI scanner with real-time and MR fluoroscopy techniques were evaluated retrospectively. All procedures were performed under local anaesthesia and intravenous conscious sedation. Diagnostic yield, diagnostic accuracy, complication rate and procedure duration were assessed. The lesions were divided into two groups according to maximum diameters: ≤ 1.5 cm (n = 16) and > 1.5 cm (n = 70). The two groups were compared using Fisher’s exact test. Results Diagnostic yield and diagnostic accuracy were 95.3% and 94.2%, respectively. The diagnostic yield of lesions ≤ 1.5 cm and > 1.5 cm were 93.8% and 95.7%, respectively. There was no significant difference in diagnostic yield between the two groups (p > 0.05). Mean procedure duration was 41 ± 5 min (range 33–49 min). All biopsy needles were placed with one pass. Complication rate was 3.5% (3/86). Minor complications included three cases of a small amount of haemorrhage. No serious complications were observed. Conclusions Real-time MR-guided brain biopsy using a 1.0-T open MRI scanner is a safe, feasible and accurate diagnostic technique for pathological diagnosis of brain lesions. The procedure duration is shortened and biopsy work flow is simplified. It could be considered as an alternative for brain biopsy. Key Points • Real-time MRI-guided brain biopsy using a 1.0-T open MRI scanner is safe, feasible and accurate. • No serious complications occurred in real-time MRI-guided brain biopsy. • Procedure duration is shortened and biopsy work flow is simplified.
- 26 May 2018
- Published by Springer Nature in Neurochemical Research
- Vol. 43 (7) , 1317-1327
Combined Strategy of Radioactive 125I Seeds and Salinomycin for Enhanced Glioma Chemo-radiotherapy: Evidences for ROS-Mediated Apoptosis and Signaling Crosstalk
Radioactive 125I seeds-based radiotherapy has achieved great success in treatment of human cancers. However, radioresistance and severe side effects badly limited its clinic application. Recently, chemoradiotherapy as a superior strategy has been rapidly developed and widely used in clinic. However, the underlying mechanism remains elusive. Herein, in the present study, a combined chemoradiation model of 125I seeds and salinomycin (SAL) in vitro and in vivo was designed, and the enhanced anticancer efficiency and mechanism were also evaluated in human glioma. The results showed that combined treatment of 125I seeds and SAL induced enhanced growth inhibition against human glioma cells through induction of cell apoptosis. Further investigation revealed that combined treatment of 125I seeds and SAL triggered enhanced DNA damage through inducing reactive oxide species (ROS) generation. Additionally, enhanced dysfunction of MAPKs and AKT pathways both contributed to combined treatment-induced growth inhibition against human glioma cells. Importantly, the U251 human glioma xenograft growth was effectively inhibited by combined treatment of 125I seeds and SAL by induction of cell apoptosis with involvement of inhibiting cell proliferation and angiogenesis. Taken together, our results indicated that combined treatment of 125I seeds and SAL achieved enhanced growth inhibition and apoptosis in human glioma in vitro and in vivo through triggering ROS-mediated DNA damage and regulation of MAPKs and AKT pathways, which validated that the combined strategy of using 125I seeds and SAL could be a highly efficient way to achieve enhanced glioma chemo-radiotherapy.
- 26 May 2018
- Published by Springer Nature in Neurochemical Research
- Vol. 43 (7) , 1317-1327
Combined Strategy of Radioactive 125I Seeds and Salinomycin for Enhanced Glioma Chemo-radiotherapy: Evidences for ROS-Mediated Apoptosis and Signaling Crosstalk
Radioactive 125I seeds-based radiotherapy has achieved great success in treatment of human cancers. However, radioresistance and severe side effects badly limited its clinic application. Recently, chemoradiotherapy as a superior strategy has been rapidly developed and widely used in clinic. However, the underlying mechanism remains elusive. Herein, in the present study, a combined chemoradiation model of 125I seeds and salinomycin (SAL) in vitro and in vivo was designed, and the enhanced anticancer efficiency and mechanism were also evaluated in human glioma. The results showed that combined treatment of 125I seeds and SAL induced enhanced growth inhibition against human glioma cells through induction of cell apoptosis. Further investigation revealed that combined treatment of 125I seeds and SAL triggered enhanced DNA damage through inducing reactive oxide species (ROS) generation. Additionally, enhanced dysfunction of MAPKs and AKT pathways both contributed to combined treatment-induced growth inhibition against human glioma cells. Importantly, the U251 human glioma xenograft growth was effectively inhibited by combined treatment of 125I seeds and SAL by induction of cell apoptosis with involvement of inhibiting cell proliferation and angiogenesis. Taken together, our results indicated that combined treatment of 125I seeds and SAL achieved enhanced growth inhibition and apoptosis in human glioma in vitro and in vivo through triggering ROS-mediated DNA damage and regulation of MAPKs and AKT pathways, which validated that the combined strategy of using 125I seeds and SAL could be a highly efficient way to achieve enhanced glioma chemo-radiotherapy.
- 10 January 2018
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 48 (2) , 382-388
1.0T MR‐guided percutaneous coaxial cutting needle biopsy in pancreatic lesion diagnosis
Background: Pancreatic carcinoma is a common cause of cancer deaths worldwide. Biopsy is often required for the initial diagnosis of pancreatic masses. Biopsy can be performed endoscopically or percutaneously with computed tomography (CT) and ultrasound (US) guidance. MRI offers many inherent advantages over CT and US.Purpose/Hypothesis: To prospectively evaluate the feasibility, accuracy, and safety of MRI‐guided percutaneous coaxial cutting needle biopsy of pancreatic lesions using an open 1.0T high‐field MR scanner.Study Type: Prospective.Population: Thirty‐one patients with 31 pancreatic lesions underwent MR‐guided percutaneous coaxial cutting needle biopsy.Field Strength/Sequence: 1.0T T2WI‐TSE PDW‐aTSE T1WI‐TFE.Assessment: Final diagnosis was confirmed by surgery and clinical follow‐up for at least 12 months. The accuracy, sensitivity, and specificity were calculated. Complications were recorded.Statistical Tests: There was no statistical analysis in this study.Results: The procedure was technically successful and final biopsy samples were adequate for histopathological examination in all patients. Biopsy pathology revealed malignant pancreatic tumor in 25 patients (25/31, 80.6%), and benign pancreatic lesions were present in six patients (6/31, 19.4%). The final diagnosis was pancreatic malignancy in 27 patients and benign disease in four patients, which was confirmed by surgery and clinical follow‐up. Two biopsy results were false‐negative. The diagnostic accuracy in biopsies was 93.5% (29 of 31). The sensitivity to detect a malignant disease was 92.6% (25 of 27), and the specificity was 100%. All patients tolerated the procedure well; minor peripancreatic hemorrhage was found in two patients after the procedure, and none had major complications either during or after the procedure.Data Conclusion: MRI‐guided percutaneous biopsy of pancreatic lesions using an open 1.0T high‐field scanner has high diagnostic accuracy, which is feasible and safe for use in clinical practice.Level of Evidence: 2Technical Efficacy: Stage 2J. MAGN. RESON. IMAGING 2018;48:382–388.
- 10 January 2018
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 48 (2) , 382-388
1.0T MR‐guided percutaneous coaxial cutting needle biopsy in pancreatic lesion diagnosis
Background: Pancreatic carcinoma is a common cause of cancer deaths worldwide. Biopsy is often required for the initial diagnosis of pancreatic masses. Biopsy can be performed endoscopically or percutaneously with computed tomography (CT) and ultrasound (US) guidance. MRI offers many inherent advantages over CT and US.Purpose/Hypothesis: To prospectively evaluate the feasibility, accuracy, and safety of MRI‐guided percutaneous coaxial cutting needle biopsy of pancreatic lesions using an open 1.0T high‐field MR scanner.Study Type: Prospective.Population: Thirty‐one patients with 31 pancreatic lesions underwent MR‐guided percutaneous coaxial cutting needle biopsy.Field Strength/Sequence: 1.0T T2WI‐TSE PDW‐aTSE T1WI‐TFE.Assessment: Final diagnosis was confirmed by surgery and clinical follow‐up for at least 12 months. The accuracy, sensitivity, and specificity were calculated. Complications were recorded.Statistical Tests: There was no statistical analysis in this study.Results: The procedure was technically successful and final biopsy samples were adequate for histopathological examination in all patients. Biopsy pathology revealed malignant pancreatic tumor in 25 patients (25/31, 80.6%), and benign pancreatic lesions were present in six patients (6/31, 19.4%). The final diagnosis was pancreatic malignancy in 27 patients and benign disease in four patients, which was confirmed by surgery and clinical follow‐up. Two biopsy results were false‐negative. The diagnostic accuracy in biopsies was 93.5% (29 of 31). The sensitivity to detect a malignant disease was 92.6% (25 of 27), and the specificity was 100%. All patients tolerated the procedure well; minor peripancreatic hemorrhage was found in two patients after the procedure, and none had major complications either during or after the procedure.Data Conclusion: MRI‐guided percutaneous biopsy of pancreatic lesions using an open 1.0T high‐field scanner has high diagnostic accuracy, which is feasible and safe for use in clinical practice.Level of Evidence: 2Technical Efficacy: Stage 2J. MAGN. RESON. IMAGING 2018;48:382–388.
- Open Access
- 20 July 2017
- Published by International Institute of Anticancer Research in Anticancer Research
- Vol. 37 (8) , 4635-4641
MR-guided Percutaneous Biopsy of Focal Hepatic Dome Lesions with Free-hand Combined with MR Fluoroscopy Using 1.0-T Open High-field Scanner
Aim: To prospectively estimate the safety, feasibility and accuracy of 1.0T open-magnetic resonance (MR)-guided percutaneous biopsy in free-hand of focal lesions located in the hepatic dome. Materials and Methods: All percutaneous MR-guided biopsies of the lesions were performed at the Shandong Medical Imaging Research Institute. Thirty-six patients with focal liver lesions located in the hepatic dome measuring 6-36 mm in the maximum diameter were included in this study. Lesions were divided into two groups on the basis of maximum nodule diameters: ≤1.5 cm (n=14) and >1.5 cm (n=22). Surgical pathology of nodules or clinical and imaging follow-up for at least 12 months were used to establish final diagnosis. Diagnostic accuracy, specificity, sensitivity, average procedure time and complications were recorded and analyzed. Results: All obtained samples were sufficient for diagnosis. Accuracy, sensitivity and specificity of MRI-guided percutaneous liver lesions biopsy in diagnosing malignant tumors were 97.2%, 96.7% and 100%, respectively. Accuracy, sensitivity and specificity were 92.9%, 90.9% and 100% for the lesions that were 1.5 cm or smaller in diameter and 100%, 100% and 100% for lesions larger than 1.5 cm in diameter, respectively. There was no significant difference between the two groups (p>0.05). The average procedure time for each pass of the needle from skin entry to the target lesion was 1.1 min and the total procedural time was 28.5 min. Biopsy-induced complications included peri-hepatic hemorrhage in 8.3% (3/36) of cases. No serious complications occurred. Conclusion: 1.0T open-MR-guided free-hand percutaneous biopsy is a safe, feasible and highly accurate diagnostic method for pathological diagnosis of focal liver lesions located in the hepatic dome.
- 20 July 2017
- Published by International Institute of Anticancer Research in Anticancer Research
- Vol. 37 (8) , 4635-4641
Open AccessMR-guided Percutaneous Biopsy of Focal Hepatic Dome Lesions with Free-hand Combined with MR Fluoroscopy Using 1.0-T Open High-field Scanner
Aim: To prospectively estimate the safety, feasibility and accuracy of 1.0T open-magnetic resonance (MR)-guided percutaneous biopsy in free-hand of focal lesions located in the hepatic dome. Materials and Methods: All percutaneous MR-guided biopsies of the lesions were performed at the Shandong Medical Imaging Research Institute. Thirty-six patients with focal liver lesions located in the hepatic dome measuring 6-36 mm in the maximum diameter were included in this study. Lesions were divided into two groups on the basis of maximum nodule diameters: ≤1.5 cm (n=14) and >1.5 cm (n=22). Surgical pathology of nodules or clinical and imaging follow-up for at least 12 months were used to establish final diagnosis. Diagnostic accuracy, specificity, sensitivity, average procedure time and complications were recorded and analyzed. Results: All obtained samples were sufficient for diagnosis. Accuracy, sensitivity and specificity of MRI-guided percutaneous liver lesions biopsy in diagnosing malignant tumors were 97.2%, 96.7% and 100%, respectively. Accuracy, sensitivity and specificity were 92.9%, 90.9% and 100% for the lesions that were 1.5 cm or smaller in diameter and 100%, 100% and 100% for lesions larger than 1.5 cm in diameter, respectively. There was no significant difference between the two groups (p>0.05). The average procedure time for each pass of the needle from skin entry to the target lesion was 1.1 min and the total procedural time was 28.5 min. Biopsy-induced complications included peri-hepatic hemorrhage in 8.3% (3/36) of cases. No serious complications occurred. Conclusion: 1.0T open-MR-guided free-hand percutaneous biopsy is a safe, feasible and highly accurate diagnostic method for pathological diagnosis of focal liver lesions located in the hepatic dome.
- Open Access
- 6 May 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 42 (6) , 1740-1746
MRI‐guided percutaneous transpedicular biopsy of thoracic and lumbar spine using a 0.23t scanner with optical instrument tracking
Purpose To prospectively evaluate the safety and accuracy of magnetic resonance imaging (MRI)‐guided percutaneous transpedicular biopsy of thoracic and lumbar spine using 0.23T magnetic resonance imaging with optical tracking. Materials and Methods Sixty‐seven thoracic and lumbar spine lesions in 67 patients underwent MRI‐guided percutaneous transpedicular biopsy using 0.23T MRI with optical tracking. These lesions were divided into two groups according to the location: 16 lesions in the thoracic spine and 51 lesions in the lumbar spine. The diagnostic accuracy, sensitivity, and specificity were calculated, and comparison of the two groups was performed using Fisher's exact test. Each patient was monitored for complications. Results All specimens obtained were sufficient for diagnosis. Histological examination of MRI‐guided percutaneous biopsy revealed 38 malignant and 29 benign lesions. The final diagnoses from surgery or clinical follow‐up were 42 malignant lesions and 25 benign lesions. The combined diagnostic performance of MRI‐guided percutaneous transpedicular thoracic and lumbar biopsy in diagnosing malignant tumors was as follows: accuracy, 94%; sensitivity, 89%; and specificity, 100%. There was no significant difference between the two groups (P = 1, Fisher's exact test). No serious complications occurred. Conclusion MRI‐guided percutaneous transpedicular biopsy is a safe and accurate diagnostic technique to evaluate thoracic and lumbar spine lesions. J. Magn. Reson. Imaging 2015.
- 6 May 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 42 (6) , 1740-1746
Open AccessMRI‐guided percutaneous transpedicular biopsy of thoracic and lumbar spine using a 0.23t scanner with optical instrument tracking
Purpose To prospectively evaluate the safety and accuracy of magnetic resonance imaging (MRI)‐guided percutaneous transpedicular biopsy of thoracic and lumbar spine using 0.23T magnetic resonance imaging with optical tracking. Materials and Methods Sixty‐seven thoracic and lumbar spine lesions in 67 patients underwent MRI‐guided percutaneous transpedicular biopsy using 0.23T MRI with optical tracking. These lesions were divided into two groups according to the location: 16 lesions in the thoracic spine and 51 lesions in the lumbar spine. The diagnostic accuracy, sensitivity, and specificity were calculated, and comparison of the two groups was performed using Fisher's exact test. Each patient was monitored for complications. Results All specimens obtained were sufficient for diagnosis. Histological examination of MRI‐guided percutaneous biopsy revealed 38 malignant and 29 benign lesions. The final diagnoses from surgery or clinical follow‐up were 42 malignant lesions and 25 benign lesions. The combined diagnostic performance of MRI‐guided percutaneous transpedicular thoracic and lumbar biopsy in diagnosing malignant tumors was as follows: accuracy, 94%; sensitivity, 89%; and specificity, 100%. There was no significant difference between the two groups (P = 1, Fisher's exact test). No serious complications occurred. Conclusion MRI‐guided percutaneous transpedicular biopsy is a safe and accurate diagnostic technique to evaluate thoracic and lumbar spine lesions. J. Magn. Reson. Imaging 2015.