Hong Suk Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hong Suk Park has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Kwang Bo Park
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
8 shared publicationsYoung Soo Do
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
7 shared publicationsDongho Hyun
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
6 shared publicationsSung Ki Cho
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
6 shared publicationsSung Wook Choo
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
6 shared publicationsSung Wook Shin
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
6 shared publications
Latest Publications
- Open Access
- 1 December 2022
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 12 (12) , 5420-5432
Risk factors for stent occlusion after catheter-directed thrombolysis and iliac vein stenting in the treatment of May-Thurner syndrome with iliofemoral deep vein thrombosis: a retrospective cohort study
Original Article Risk factors for stent occlusion after catheter-directed thrombolysis and iliac vein stenting in the treatment of May-Thurner syndrome with iliofemoral deep vein thrombosis: a retrospective cohort study Myung Sub Kim, Hong Suk Park, Hyun Pyo Hong, Dongho Hyun, Sung Ki Cho, Kwang Bo Park, Sung Wook Shin, Sung Wook Choo, Young Soo Do
- 1 December 2022
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 12 (12) , 5420-5432
Open AccessRisk factors for stent occlusion after catheter-directed thrombolysis and iliac vein stenting in the treatment of May-Thurner syndrome with iliofemoral deep vein thrombosis: a retrospective cohort study
Original Article Risk factors for stent occlusion after catheter-directed thrombolysis and iliac vein stenting in the treatment of May-Thurner syndrome with iliofemoral deep vein thrombosis: a retrospective cohort study Myung Sub Kim, Hong Suk Park, Hyun Pyo Hong, Dongho Hyun, Sung Ki Cho, Kwang Bo Park, Sung Wook Shin, Sung Wook Choo, Young Soo Do
- 19 November 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (6) , 746-753
Guidewire-catheter induced hydrodissection to assist radiofrequency ablation for subcapsular hepatocellular carcinoma with iodized oil retention in patients with failed artificial ascites due to perihepatic adhesion
We aimed to evaluate the usefulness of guidewire-catheter induced hydrodissection (GIH) to assist radiofrequency ablation (RFA) for subcapsular hepatocellular carcinoma (HCC) with iodized oil retention in patients with failed artificial ascites due to perihepatic adhesion. This retrospective study included 17 patients with small subcapsular HCC ineligible for ultrasonography-guided RFA who received RFA under guidance of fluoroscopy and cone-beam computed tomography immediately after iodized oil transarterial chemoembolization (TACE) between April 2011 and January 2016. In the study patients, creation of artificial ascites to protect the perihepatic structures failed due to perihepatic adhesion and GIH was attempted to separate the perihepatic structures from the ablation zone. The technical success rate of GIH, technique efficacy of RFA with GIH, local tumor progression (LTP), peritoneal seeding, and complications were evaluated. The technical success rate of GIH was 88.24% (15 of 17 patients). Technique efficacy was achieved in all 15 patients receiving RFA with GIH. During an average follow-up period of 48.1 months, LTP developed in three patients. Cumulative LTP rates at 1, 2, 3, and 5 years were 13.3%, 20.6%, 20.6%, and 20.6%, respectively. No patient had peritoneal seeding. Two of the 15 patients receiving RFA with GIH had a CIRSE grade 3 liver abscess, but none had complications associated with thermal injury to the diaphragm or abdominal wall near the ablation zone. GIH can be a useful method to assist RFA for subcapsular HCC with iodized oil retention in patients with failed artificial ascites due to perihepatic adhesion.
- 19 November 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (6) , 746-753
Guidewire-catheter induced hydrodissection to assist radiofrequency ablation for subcapsular hepatocellular carcinoma with iodized oil retention in patients with failed artificial ascites due to perihepatic adhesion
We aimed to evaluate the usefulness of guidewire-catheter induced hydrodissection (GIH) to assist radiofrequency ablation (RFA) for subcapsular hepatocellular carcinoma (HCC) with iodized oil retention in patients with failed artificial ascites due to perihepatic adhesion. This retrospective study included 17 patients with small subcapsular HCC ineligible for ultrasonography-guided RFA who received RFA under guidance of fluoroscopy and cone-beam computed tomography immediately after iodized oil transarterial chemoembolization (TACE) between April 2011 and January 2016. In the study patients, creation of artificial ascites to protect the perihepatic structures failed due to perihepatic adhesion and GIH was attempted to separate the perihepatic structures from the ablation zone. The technical success rate of GIH, technique efficacy of RFA with GIH, local tumor progression (LTP), peritoneal seeding, and complications were evaluated. The technical success rate of GIH was 88.24% (15 of 17 patients). Technique efficacy was achieved in all 15 patients receiving RFA with GIH. During an average follow-up period of 48.1 months, LTP developed in three patients. Cumulative LTP rates at 1, 2, 3, and 5 years were 13.3%, 20.6%, 20.6%, and 20.6%, respectively. No patient had peritoneal seeding. Two of the 15 patients receiving RFA with GIH had a CIRSE grade 3 liver abscess, but none had complications associated with thermal injury to the diaphragm or abdominal wall near the ablation zone. GIH can be a useful method to assist RFA for subcapsular HCC with iodized oil retention in patients with failed artificial ascites due to perihepatic adhesion.
- 17 March 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (9) , 6568-6577
Radiologic and clinical results of transarterial ethanol embolization for renal angiomyolipoma
Objective We sought to determine the efficacy and safety of selective arterial embolization for renal angiomyolipoma (AML) using ethanol alone or ethanol with additional embolic materials and to analyze the factors influencing safety and efficacy. Methods One hundred nineteen AMLs treated with embolization were included retrospectively during a 15-year period. Technical, radiologic, and clinical success were recorded and risk factor analysis was performed. Complications on follow-up images, post-embolization syndrome (PES), major complications, and changes in renal function were also evaluated. Results Technical success was achieved in 106 of 119 tumors. Tumor size significantly decreased after treatment (reduction rate: 55%). Significant risk factors for tumor reduction included tumor enhancement on preprocedural CT and residual tumor staining. Radiologic success was achieved in 114 of 119 tumors (risk factor: residual tumor staining), and clinical success was achieved in 22 of 23 patients. Complications on follow-up images occurred in 40 of 119 tumors, and PES occurred in 53 of 104 patients. No major complications occurred. There were no cases of renal function impairment. Conclusion Selective transarterial embolization using ethanol alone or ethanol with additional embolic materials reduced AML size, alleviated symptoms, and can be performed safely without permanent impairment. Key Points • Percutaneous transarterial ethanol embolization reduces AML size and alleviates symptoms. • Embolization can be performed safely without permanent impairment of renal function.
- 17 March 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (9) , 6568-6577
Radiologic and clinical results of transarterial ethanol embolization for renal angiomyolipoma
Objective We sought to determine the efficacy and safety of selective arterial embolization for renal angiomyolipoma (AML) using ethanol alone or ethanol with additional embolic materials and to analyze the factors influencing safety and efficacy. Methods One hundred nineteen AMLs treated with embolization were included retrospectively during a 15-year period. Technical, radiologic, and clinical success were recorded and risk factor analysis was performed. Complications on follow-up images, post-embolization syndrome (PES), major complications, and changes in renal function were also evaluated. Results Technical success was achieved in 106 of 119 tumors. Tumor size significantly decreased after treatment (reduction rate: 55%). Significant risk factors for tumor reduction included tumor enhancement on preprocedural CT and residual tumor staining. Radiologic success was achieved in 114 of 119 tumors (risk factor: residual tumor staining), and clinical success was achieved in 22 of 23 patients. Complications on follow-up images occurred in 40 of 119 tumors, and PES occurred in 53 of 104 patients. No major complications occurred. There were no cases of renal function impairment. Conclusion Selective transarterial embolization using ethanol alone or ethanol with additional embolic materials reduced AML size, alleviated symptoms, and can be performed safely without permanent impairment. Key Points • Percutaneous transarterial ethanol embolization reduces AML size and alleviates symptoms. • Embolization can be performed safely without permanent impairment of renal function.
- 3 March 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (9) , 6531-6538
Percutaneous radiologic gastrostomy with single gastropexy: outcomes in 636 patients
Objectives This study aimed to assess the technical success and overall complication rate of percutaneous radiologic gastrostomy (PRG) with single gastropexy using a separate tract from that used for tube placement. Methods From January 2014 to December 2018, 636 patients (469 men, 167 women; mean age 66.8 years; age range, 22–98 years) underwent PRG using single gastropexy at a tertiary center. Preprocedural computed tomography (CT) was recommended if there were no data on the location of the stomach on previous CT. After a single anchor was applied, the PRG tube was inserted through a separate tract from that used for tube placement. The technical success rate and major and minor complications were retrospectively reviewed. The number of patients and percentages were used as descriptive statistics for evaluating the complication rate. Results The technical success rate of PRG with single gastropexy was 99.2% (631/636). There were 32 complications among the 631 procedures. There were 19 (3.0%) major complications, including peritonitis (n = 7), migration (n = 5), infection (n=4), malposition (n = 2), and bleeding (n = 1). There were 13 (2.1%) minor complications, including local infection (n = 11), malfunction (n = 1), and pneumoperitoneum (n = 1). The overall complication rate within 30 days of PRG placement was 4.1% (26/631). Conclusions PRG with single gastropexy using a separate tract from that used for tube placement is technically feasible with a low complication rate. Key Points • Percutaneous radiologic gastrostomy with single gastropexy using a separate tract from that used for tube placement is technically feasible. • Complications including peritonitis and bleeding were comparatively low with the conventional technique.
- 3 March 2021
- Published by Springer Nature in European Radiology
- Vol. 31 (9) , 6531-6538
Percutaneous radiologic gastrostomy with single gastropexy: outcomes in 636 patients
Objectives This study aimed to assess the technical success and overall complication rate of percutaneous radiologic gastrostomy (PRG) with single gastropexy using a separate tract from that used for tube placement. Methods From January 2014 to December 2018, 636 patients (469 men, 167 women; mean age 66.8 years; age range, 22–98 years) underwent PRG using single gastropexy at a tertiary center. Preprocedural computed tomography (CT) was recommended if there were no data on the location of the stomach on previous CT. After a single anchor was applied, the PRG tube was inserted through a separate tract from that used for tube placement. The technical success rate and major and minor complications were retrospectively reviewed. The number of patients and percentages were used as descriptive statistics for evaluating the complication rate. Results The technical success rate of PRG with single gastropexy was 99.2% (631/636). There were 32 complications among the 631 procedures. There were 19 (3.0%) major complications, including peritonitis (n = 7), migration (n = 5), infection (n=4), malposition (n = 2), and bleeding (n = 1). There were 13 (2.1%) minor complications, including local infection (n = 11), malfunction (n = 1), and pneumoperitoneum (n = 1). The overall complication rate within 30 days of PRG placement was 4.1% (26/631). Conclusions PRG with single gastropexy using a separate tract from that used for tube placement is technically feasible with a low complication rate. Key Points • Percutaneous radiologic gastrostomy with single gastropexy using a separate tract from that used for tube placement is technically feasible. • Complications including peritonitis and bleeding were comparatively low with the conventional technique.
- 6 June 2020
- Published by SAGE Publications in Phlebology: The Journal of Venous Disease
- Vol. 35 (9) , 672-678
Factors associated with the development of post-thrombotic syndrome in patients with iliofemoral deep venous thrombosis who underwent catheter-directed thrombolysis
Objective: To identify predictors of post-thrombotic syndrome in patients with iliofemoral deep venous thrombosis who underwent catheter-directed thrombolysis. Methods: Fifty-two consecutive patients who underwent catheter-directed thrombolysis were included in this retrospective study. In addition to catheter-directed thrombolysis, aspiration thrombectomy or stent placement was performed if needed. At six months, duplex ultrasound was performed to assess iliofemoral patency and deep venous reflux. Post-thrombotic syndrome was assessed using the clinical, etiologic, anatomic, and pathophysiologic classification (post-thrombotic syndrome present ≥3 on a scale from 0 to 6). Univariate analysis and multivariate logistic regression were used to identify predictors of post-thrombotic syndrome. Results: Median follow-up was 52 months and post-thrombotic syndrome developed in nine patients (17.3%). In univariate analysis, stent placement (odds ratio 0.16, p = 0.022) was negatively associated with post-thrombotic syndrome, whereas iliofemoral venous obstruction with reflux at six months (OR 6.08, p = 0.037) was positively associated with post-thrombotic syndrome. Multivariate analysis indicated that stent placement was associated with reduced risk of post-thrombotic syndrome (OR 0.17, p = 0.043), and iliofemoral obstruction with reflux was associated with increased risk (OR 6.67, p = 0.046). Conclusion: Stent placement and iliofemoral venous obstruction with reflux, respectively, were important protective and risk factors for post-thrombotic syndrome in patients who underwent catheter-directed thrombolysis.
- 6 June 2020
- Published by SAGE Publications in Phlebology: The Journal of Venous Disease
- Vol. 35 (9) , 672-678
Factors associated with the development of post-thrombotic syndrome in patients with iliofemoral deep venous thrombosis who underwent catheter-directed thrombolysis
Objective: To identify predictors of post-thrombotic syndrome in patients with iliofemoral deep venous thrombosis who underwent catheter-directed thrombolysis. Methods: Fifty-two consecutive patients who underwent catheter-directed thrombolysis were included in this retrospective study. In addition to catheter-directed thrombolysis, aspiration thrombectomy or stent placement was performed if needed. At six months, duplex ultrasound was performed to assess iliofemoral patency and deep venous reflux. Post-thrombotic syndrome was assessed using the clinical, etiologic, anatomic, and pathophysiologic classification (post-thrombotic syndrome present ≥3 on a scale from 0 to 6). Univariate analysis and multivariate logistic regression were used to identify predictors of post-thrombotic syndrome. Results: Median follow-up was 52 months and post-thrombotic syndrome developed in nine patients (17.3%). In univariate analysis, stent placement (odds ratio 0.16, p = 0.022) was negatively associated with post-thrombotic syndrome, whereas iliofemoral venous obstruction with reflux at six months (OR 6.08, p = 0.037) was positively associated with post-thrombotic syndrome. Multivariate analysis indicated that stent placement was associated with reduced risk of post-thrombotic syndrome (OR 0.17, p = 0.043), and iliofemoral obstruction with reflux was associated with increased risk (OR 6.67, p = 0.046). Conclusion: Stent placement and iliofemoral venous obstruction with reflux, respectively, were important protective and risk factors for post-thrombotic syndrome in patients who underwent catheter-directed thrombolysis.
- Open Access
- 1 January 2015
- Published by Hindawi Limited in BioMed Research International
- Vol. 2015, 1-6
A Novel Foam Contrast Agent Suitable for Fluoroscopic Interventional Procedure: Comparative Study of Physical Properties and Experimental Intervention in Animal Model
In fluoroscopic contrast study for interventional procedure, liquid contrast agent may be diluted in body fluid, losing its contrast effect. We developed a novel contrast agent of “foam state” to maintain contrast effect for enough time and performed a comparative study of physical properties and its usefulness in experimental intervention in animal model. The mean size of microbubble of foam contrast was µm. The viscosity was cP (centipoise) and the specific gravity was 0.616. The foam decayed slowly and it had 97.5 minutes of half-life. In terms of the sustainability in a slow flow environment, foam contrast washed out much more slowly than a conventional contrast. In experimental colonic stent placement, foam contrast revealed significantly better results than conventional contrast in procedure time, total amount of contrast usage, and the number of injections (). Our foam contrast has high viscosity and low specific gravity and maintains foam state for a sufficient time. Foam contrast with these properties was useful in experimental intervention in animal model. We anticipate that foam contrast may be applied to various kinds of interventional procedures.- 1 January 2015
- Published by Hindawi Limited in BioMed Research International
- Vol. 2015, 1-6
Open AccessA Novel Foam Contrast Agent Suitable for Fluoroscopic Interventional Procedure: Comparative Study of Physical Properties and Experimental Intervention in Animal Model
In fluoroscopic contrast study for interventional procedure, liquid contrast agent may be diluted in body fluid, losing its contrast effect. We developed a novel contrast agent of “foam state” to maintain contrast effect for enough time and performed a comparative study of physical properties and its usefulness in experimental intervention in animal model. The mean size of microbubble of foam contrast was µm. The viscosity was cP (centipoise) and the specific gravity was 0.616. The foam decayed slowly and it had 97.5 minutes of half-life. In terms of the sustainability in a slow flow environment, foam contrast washed out much more slowly than a conventional contrast. In experimental colonic stent placement, foam contrast revealed significantly better results than conventional contrast in procedure time, total amount of contrast usage, and the number of injections (). Our foam contrast has high viscosity and low specific gravity and maintains foam state for a sufficient time. Foam contrast with these properties was useful in experimental intervention in animal model. We anticipate that foam contrast may be applied to various kinds of interventional procedures. - 1 April 2014
- Published by Elsevier in Journal of Surgical Research
- Vol. 187 (2) , 445-449
A novel animal model of gastrointestinal obstruction for the development of stent
- 1 April 2014
- Published by Elsevier in Journal of Surgical Research
- Vol. 187 (2) , 445-449
A novel animal model of gastrointestinal obstruction for the development of stent
- 1 November 2013
- Published by Elsevier in European Journal of Radiology
- Vol. 82 (11) , 1913-1918
Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement
- 1 November 2013
- Published by Elsevier in European Journal of Radiology
- Vol. 82 (11) , 1913-1918
Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement
- 27 December 2011
- Published by Springer Nature in Urological Research
- Vol. 40 (4) , 425-428
Squamous cell carcinoma must be considered in patients with long standing upper ureteral stone and pyonephrosis
- 27 December 2011
- Published by Springer Nature in Urological Research
- Vol. 40 (4) , 425-428
Squamous cell carcinoma must be considered in patients with long standing upper ureteral stone and pyonephrosis
- Open Access
- 30 November 2011
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 27 (4) , 162-167
Natural History of Type II Endoleaks after Endovascular Aneurysm Repair in Abdominal Aortic Aneurysm
Cho DM, et al. Korean J Vasc Endovasc Surg. 2011 Nov;27(4):162-167. http://dx.doi.org/10.5758/kjves.2011.27.4.162
- 30 November 2011
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 27 (4) , 162-167
Open AccessNatural History of Type II Endoleaks after Endovascular Aneurysm Repair in Abdominal Aortic Aneurysm
Cho DM, et al. Korean J Vasc Endovasc Surg. 2011 Nov;27(4):162-167. http://dx.doi.org/10.5758/kjves.2011.27.4.162