Yunshan Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yunshan Sun has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Liyi Zhang
School of Information Engineering, Tianjin University of Commerce, Tianjin, China
1 shared publication - Yuan Zhang
School of Electronic Engineering, Tianjin University of Technology and Education, Tianjin, China
1 shared publication
Latest Publications
- 3 December 2020
- Published by Bentham Science Publishers Ltd. in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
- Vol. 13 (8) , 1119-1128
Rigid Motion Artifact Reduction in CT Using the Phase Correlation Method
Background: In computed tomography (CT), it is often not possible for the subject to remain stationary during a scan. Unfortunately, a patient motion would result in degraded spatial resolution and image artifacts. It is desirable to improve reconstruction quality and reduce motion artifacts caused by patient motion. Methods: In this work, a method was proposed to eliminate the influence of the motion on image quality based on phase correlation method. Based on our previous work, projections were first taken by Radon transform and motion parameters were estimated by the phase-only correlation of projections in Radon domain. In addition, an improved image reconstruction algorithm was performed to compensate for the motion effects. Results: Experimental results proved that the proposed method could not only obtain high precision and good real-time performance, but also ensure a superior artifact reduction. Conclusion: Besides, the efficacy of the proposed method have been demonstrated on both simulated and human head experiments.
- 3 December 2020
- Published by Bentham Science Publishers Ltd. in Recent Advances in Electrical & Electronic Engineering (Formerly Recent Patents on Electrical & Electronic Engineering)
- Vol. 13 (8) , 1119-1128
Rigid Motion Artifact Reduction in CT Using the Phase Correlation Method
Background: In computed tomography (CT), it is often not possible for the subject to remain stationary during a scan. Unfortunately, a patient motion would result in degraded spatial resolution and image artifacts. It is desirable to improve reconstruction quality and reduce motion artifacts caused by patient motion. Methods: In this work, a method was proposed to eliminate the influence of the motion on image quality based on phase correlation method. Based on our previous work, projections were first taken by Radon transform and motion parameters were estimated by the phase-only correlation of projections in Radon domain. In addition, an improved image reconstruction algorithm was performed to compensate for the motion effects. Results: Experimental results proved that the proposed method could not only obtain high precision and good real-time performance, but also ensure a superior artifact reduction. Conclusion: Besides, the efficacy of the proposed method have been demonstrated on both simulated and human head experiments.