Jinseok Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jinseok Kim has a total of 249 co-authors. Here are the top co-authors by number of shared publications:
Jae-Chul Kim
16 shared publicationsSung-Hun Lim
12 shared publications- HyungDal Park
Center for Bionics, Korea Institute of Science and Technology, Seoul 02792, Republic of Korea
9 shared publications - Minsu Jang
Center for Bionics, Korea Institute of Science and Technology, Seoul, South Korea
8 shared publications - Seonho Seok
Center for Nanoscience and Nanotechnology (C2N), University-Paris-Saclay, 91400 Orsay, France
6 shared publications - Wonsuk Choi
Center for Bionics, Korea Institute of Science and Technology, Seoul, Republic of Korea
6 shared publications
Latest Publications
- Open Access
- 3 October 2026
- Published by Springer Nature in Micro and Nano Systems Letters
- Vol. 14 (1) , 14
Enhanced mechanical and electrical performance of Ti/Au microelectrode arrays using a pre-cured polyimide substrate
- 3 October 2026
- Published by Springer Nature in Micro and Nano Systems Letters
- Vol. 14 (1) , 14
Open AccessEnhanced mechanical and electrical performance of Ti/Au microelectrode arrays using a pre-cured polyimide substrate
- Open Access
Bio‐Compatible Flexible Memristive Devices Enabled by BNNT/MWCNT–ZnO Quantum Dot Hybrid Percolation Networks
Flexible, transparent resistive random‐access memory (ReRAM) is promising for next‐generation wearable and bio‐integrated electronics requiring low power and material safety. Here, we report a flexible and transparent ReRAM device based on a BNNT rod/MWCNT–ZnO quantum dot (QD) nanocomposite and evaluate its electrical operation under static bending, stability after low‐temperature exposure, and biocompatibility. The fabricated Al/nanocomposite/ITO/PET device exhibited approximately 63% optical transmittance in the visible region and maintained resistive switching under a 3 cm static bending radius. It demonstrated nonvolatile memory characteristics, including an ON/OFF current ratio over 10 3 , electrical endurance exceeding 20 000 cycles, and retention beyond 75 000 s. The memory performance remained stable at −30°C, indicating environmental robustness. Charge transport analysis revealed that switching behavior is governed by space‐charge‐limited current (SCLC) conduction at low voltages and Fowler–Nordheim tunneling at high electric fields, while the BNNT layer acts as a charge‐blocking layer to enhance retention stability. For biocompatibility, cytotoxicity testing showed cell viability satisfied ISO 10993–5, while 8‐week subcutaneous implantation revealed a transient acute inflammation that attenuated over time without necrosis. Despite non‐encapsulated conditions, explanted devices retained distinguishable resistive states, demonstrating in vivo functional stability. Overall, this nanocomposite‐based ReRAM shows potential as a memory platform for wearable and implantable bioelectronics.
Open AccessBio‐Compatible Flexible Memristive Devices Enabled by BNNT/MWCNT–ZnO Quantum Dot Hybrid Percolation Networks
Flexible, transparent resistive random‐access memory (ReRAM) is promising for next‐generation wearable and bio‐integrated electronics requiring low power and material safety. Here, we report a flexible and transparent ReRAM device based on a BNNT rod/MWCNT–ZnO quantum dot (QD) nanocomposite and evaluate its electrical operation under static bending, stability after low‐temperature exposure, and biocompatibility. The fabricated Al/nanocomposite/ITO/PET device exhibited approximately 63% optical transmittance in the visible region and maintained resistive switching under a 3 cm static bending radius. It demonstrated nonvolatile memory characteristics, including an ON/OFF current ratio over 10 3 , electrical endurance exceeding 20 000 cycles, and retention beyond 75 000 s. The memory performance remained stable at −30°C, indicating environmental robustness. Charge transport analysis revealed that switching behavior is governed by space‐charge‐limited current (SCLC) conduction at low voltages and Fowler–Nordheim tunneling at high electric fields, while the BNNT layer acts as a charge‐blocking layer to enhance retention stability. For biocompatibility, cytotoxicity testing showed cell viability satisfied ISO 10993–5, while 8‐week subcutaneous implantation revealed a transient acute inflammation that attenuated over time without necrosis. Despite non‐encapsulated conditions, explanted devices retained distinguishable resistive states, demonstrating in vivo functional stability. Overall, this nanocomposite‐based ReRAM shows potential as a memory platform for wearable and implantable bioelectronics.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 6467-6477
Real-Time Three-Dimensional Endoscope Shape Monitoring Using Long and Twist- Suppressed Fiber Bragg Grating Sensors
Standard flexible colonoscopy is a powerful diagnostic tool for detecting colorectal cancer. However, the procedure entirely depends on the skill and perception of the colonoscopist, leading to unpredictable outcomes such as loop formation, potentially leading to severe complications. Consequently, there is a growing demand for a real-time shape monitoring system for colonoscopes. Despite various research efforts and commercial products that use magnetic sensors, challenges such as signal vulnerability, cost, and limited applicability persist. Optical fiber sensors (OFS), which address these drawbacks, are gaining increasing attention. However, measuring the shape of long colonoscopes accurately remains challenging for OFS due to twist-induced noise. In this study, we developed a twist-suppressed fiber Bragg grating (FBG) sensor to measure long 3-D shapes by enhancing the linearity of the sensor and introducing a node-type structure. We also introduced an insertion length measurement algorithm for stable monitoring with this shape sensor. The twist-suppressed shape sensor exhibited a torsion angle suppression of 92% compared to conventional FBG shape sensors, achieving a torsional angle of 0.48°/cm. We evaluated the performance of the sensor by measuring bending directions and various loop shapes. Clinical tests with FBG sensors demonstrated their potential for real-time monitoring and reducing the time required for loop reduction. A colonoscopic monitoring system capable of precise shape measurements can facilitate safer and quicker procedures.
- 18 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 6467-6477
Real-Time Three-Dimensional Endoscope Shape Monitoring Using Long and Twist- Suppressed Fiber Bragg Grating Sensors
Standard flexible colonoscopy is a powerful diagnostic tool for detecting colorectal cancer. However, the procedure entirely depends on the skill and perception of the colonoscopist, leading to unpredictable outcomes such as loop formation, potentially leading to severe complications. Consequently, there is a growing demand for a real-time shape monitoring system for colonoscopes. Despite various research efforts and commercial products that use magnetic sensors, challenges such as signal vulnerability, cost, and limited applicability persist. Optical fiber sensors (OFS), which address these drawbacks, are gaining increasing attention. However, measuring the shape of long colonoscopes accurately remains challenging for OFS due to twist-induced noise. In this study, we developed a twist-suppressed fiber Bragg grating (FBG) sensor to measure long 3-D shapes by enhancing the linearity of the sensor and introducing a node-type structure. We also introduced an insertion length measurement algorithm for stable monitoring with this shape sensor. The twist-suppressed shape sensor exhibited a torsion angle suppression of 92% compared to conventional FBG shape sensors, achieving a torsional angle of 0.48°/cm. We evaluated the performance of the sensor by measuring bending directions and various loop shapes. Clinical tests with FBG sensors demonstrated their potential for real-time monitoring and reducing the time required for loop reduction. A colonoscopic monitoring system capable of precise shape measurements can facilitate safer and quicker procedures.
- Top Cited Papers
- 11 September 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (9) , 800-814
A shape-morphing cortex-adhesive sensor for closed-loop transcranial ultrasound neurostimulation
- 11 September 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (9) , 800-814
Top Cited PapersA shape-morphing cortex-adhesive sensor for closed-loop transcranial ultrasound neurostimulation
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (12) , 13883-13892
Rotational Angle Estimation Using an Acceleration Sensor Array and Real-Time Detection Algorithm
The instantaneous center of rotation (ICOR) is essential engineering information, providing wheel slip data for fully autonomous skid-steering mobile robots driven by deep learning-based dead-reckoning algorithms. Conventionally, cost-effective and compact inertial measurement unit (IMU) sensors based on microelectromechanical systems (MEMSs) have been employed for ICOR measurement. However, these sensors inherently rely on the differential value of gyroscope data, leading to significant estimation errors due to the amplified noise at low sampling rates. To address this challenge, we developed an acceleration sensor array based on a fiber Bragg grating, inspired by existing MEMS acceleration sensor arrays, which allows ICOR estimation solely from the acceleration data provided by two sensors at the beginning of rotation. The estimation accuracies in the clockwise and counter-clockwise directions were measured to be 3.1 ± 5.1 mm and 3.7 ± 9.9 mm, respectively. Furthermore, a peak detection algorithm was proposed for extracting the peak acceleration under different ICOR conditions using the variance and Bollinger bands. The precision level was comparable to those of optical cameras and MEMS IMU sensors that use computationally intensive algorithms, such as Kalman filters, even without differentiation. This breakthrough in measurement capability opens up the possibility for real-time ICOR estimation, allowing the complete automation of skid-steering-based robots and benefiting fields constrained by the structural limitations of conventional MEMS IMU sensors.
- 14 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (12) , 13883-13892
Rotational Angle Estimation Using an Acceleration Sensor Array and Real-Time Detection Algorithm
The instantaneous center of rotation (ICOR) is essential engineering information, providing wheel slip data for fully autonomous skid-steering mobile robots driven by deep learning-based dead-reckoning algorithms. Conventionally, cost-effective and compact inertial measurement unit (IMU) sensors based on microelectromechanical systems (MEMSs) have been employed for ICOR measurement. However, these sensors inherently rely on the differential value of gyroscope data, leading to significant estimation errors due to the amplified noise at low sampling rates. To address this challenge, we developed an acceleration sensor array based on a fiber Bragg grating, inspired by existing MEMS acceleration sensor arrays, which allows ICOR estimation solely from the acceleration data provided by two sensors at the beginning of rotation. The estimation accuracies in the clockwise and counter-clockwise directions were measured to be 3.1 ± 5.1 mm and 3.7 ± 9.9 mm, respectively. Furthermore, a peak detection algorithm was proposed for extracting the peak acceleration under different ICOR conditions using the variance and Bollinger bands. The precision level was comparable to those of optical cameras and MEMS IMU sensors that use computationally intensive algorithms, such as Kalman filters, even without differentiation. This breakthrough in measurement capability opens up the possibility for real-time ICOR estimation, allowing the complete automation of skid-steering-based robots and benefiting fields constrained by the structural limitations of conventional MEMS IMU sensors.
- Open Access
- 30 June 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (7) , 862
High-Porosity Sieve-Type Neural Electrodes for Motor Function Recovery and Nerve Signal Acquisition
In this study, the effects of electrode porosity on nerve regeneration and functional recovery after sciatic nerve transection in rats was investigated. A sieve-type neural electrode with 70% porosity was designed and compared with an electrode with 30% porosity. Electrodes were fabricated from photosensitive polyimide and implanted into the transected sciatic nerves. Motor function recovery was evaluated using the Sciatic Function Index. The number of active channels and their signal quality were recorded and analyzed to assess the sensory neural signal acquisition. Electrical impedance spectroscopy was used to evaluate the electrode performance. The group implanted with the 70% porosity electrode demonstrated significantly enhanced nerve regeneration and motor function recovery, approaching control group levels by the fifth week. In contrast, the group with the 30% porosity electrode exhibited limited improvement. Immunohistochemical analysis confirmed extensive nerve fiber growth within the 70% porous structure. Moreover, the 70% porosity electrode consistently acquired neural signals from more channels compared to the 30% porosity electrode, demonstrating its superior performance in sensory signal detection. These findings emphasize the importance of optimizing electrode porosity in the development of advanced neural interfaces, with the potential to enhance clinical outcomes in peripheral nerve repair and neuroprosthetic applications.
- 30 June 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (7) , 862
Open AccessHigh-Porosity Sieve-Type Neural Electrodes for Motor Function Recovery and Nerve Signal Acquisition
In this study, the effects of electrode porosity on nerve regeneration and functional recovery after sciatic nerve transection in rats was investigated. A sieve-type neural electrode with 70% porosity was designed and compared with an electrode with 30% porosity. Electrodes were fabricated from photosensitive polyimide and implanted into the transected sciatic nerves. Motor function recovery was evaluated using the Sciatic Function Index. The number of active channels and their signal quality were recorded and analyzed to assess the sensory neural signal acquisition. Electrical impedance spectroscopy was used to evaluate the electrode performance. The group implanted with the 70% porosity electrode demonstrated significantly enhanced nerve regeneration and motor function recovery, approaching control group levels by the fifth week. In contrast, the group with the 30% porosity electrode exhibited limited improvement. Immunohistochemical analysis confirmed extensive nerve fiber growth within the 70% porous structure. Moreover, the 70% porosity electrode consistently acquired neural signals from more channels compared to the 30% porosity electrode, demonstrating its superior performance in sensory signal detection. These findings emphasize the importance of optimizing electrode porosity in the development of advanced neural interfaces, with the potential to enhance clinical outcomes in peripheral nerve repair and neuroprosthetic applications.
- Open Access
- 18 April 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 543
Analysis of Experimental Biaxial Surface Wrinkling Pattern Based on Direct 3D Numerical Simulation
This paper presents a direct 3D numerical simulation of biaxial surface wrinkling of thin metal film on a compliant substrate. The selected compliant substrate is a commercial Scotch tape on which a gold metal thin film has been transferred by using low adhesion between the thin metal film and polyimide substrate. Compared with the previous fabrication of a cylindrical thin-film wrinkling pattern, an undulated wrinkling pattern has been implemented by increasing the width of the thin metal film in order to create biaxial straining in the thin film. To understand the wrinkling behavior due to biaxial loading, a simple direct numerical simulation based on material imperfections defined in the compliant substrate has been conducted. Through modeling and simulation, it was found that the wrinkling mode is determined by the biaxiality ratio (BR), the ratio between transversal strain and longitudinal strain. Depending on the BR, the wrinkling mode belongs to one of the cylindrical, undulated (or herringbone), checkerboard, or labyrinth modes as a function of applied strain. The cylindrical wrinkling is dominant at the input of BR less than 0.5, while the undulated (or herringbone) ones become dominant just after the onset of the wrinkling pattern at BR greater than 0.9. Through the comparison of the wrinkling patterns between simulation and experiment, the applied BR of the fabricated thin film has been successfully estimated.
- 18 April 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 543
Open AccessAnalysis of Experimental Biaxial Surface Wrinkling Pattern Based on Direct 3D Numerical Simulation
This paper presents a direct 3D numerical simulation of biaxial surface wrinkling of thin metal film on a compliant substrate. The selected compliant substrate is a commercial Scotch tape on which a gold metal thin film has been transferred by using low adhesion between the thin metal film and polyimide substrate. Compared with the previous fabrication of a cylindrical thin-film wrinkling pattern, an undulated wrinkling pattern has been implemented by increasing the width of the thin metal film in order to create biaxial straining in the thin film. To understand the wrinkling behavior due to biaxial loading, a simple direct numerical simulation based on material imperfections defined in the compliant substrate has been conducted. Through modeling and simulation, it was found that the wrinkling mode is determined by the biaxiality ratio (BR), the ratio between transversal strain and longitudinal strain. Depending on the BR, the wrinkling mode belongs to one of the cylindrical, undulated (or herringbone), checkerboard, or labyrinth modes as a function of applied strain. The cylindrical wrinkling is dominant at the input of BR less than 0.5, while the undulated (or herringbone) ones become dominant just after the onset of the wrinkling pattern at BR greater than 0.9. Through the comparison of the wrinkling patterns between simulation and experiment, the applied BR of the fabricated thin film has been successfully estimated.
- Open Access
- 14 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 3711-3721
Fully Implantable Neurostimulation System for Long-Term Behavioral Animal Study
Spinal cord stimulation (SCS) is an emerging therapeutic option for patients with neuropathic pain due to spinal cord injury (SCI). Numerous studies on pain relief effects with SCS have been conducted and demonstrated promising results while the mechanisms of analgesic effect during SCS remain unclear. However, an experimental system that enables large-scale long-term animal studies is still an unmet need for those mechanistic studies. This study proposed a fully wireless neurostimulation system that can efficiently support a long-term animal study for neuropathic pain relief. The developed system consists of an implantable stimulator, an animal cage with an external charging coil, and a wireless communication interface. The proposed device has the feature of remotely controlling stimulation parameters via radio-frequency (RF) communication and wirelessly charging via magnetic induction in freely moving rats. Users can program stimulation parameters such as pulse width, intensity, and duration through an interface on a computer. The stimulator was packaged with biocompatible epoxy to ensure long-term durability under in vivo conditions. Animal experiments using SCI rats were conducted to demonstrate the functionality of the device, including long-term usability and therapeutic effects. The developed system can be tailored to individual user needs with commercially available components, thus providing a cost-effective solution for large-scale long-term animal studies on neuropathic pain relief.
- 14 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 3711-3721
Open AccessFully Implantable Neurostimulation System for Long-Term Behavioral Animal Study
Spinal cord stimulation (SCS) is an emerging therapeutic option for patients with neuropathic pain due to spinal cord injury (SCI). Numerous studies on pain relief effects with SCS have been conducted and demonstrated promising results while the mechanisms of analgesic effect during SCS remain unclear. However, an experimental system that enables large-scale long-term animal studies is still an unmet need for those mechanistic studies. This study proposed a fully wireless neurostimulation system that can efficiently support a long-term animal study for neuropathic pain relief. The developed system consists of an implantable stimulator, an animal cage with an external charging coil, and a wireless communication interface. The proposed device has the feature of remotely controlling stimulation parameters via radio-frequency (RF) communication and wirelessly charging via magnetic induction in freely moving rats. Users can program stimulation parameters such as pulse width, intensity, and duration through an interface on a computer. The stimulator was packaged with biocompatible epoxy to ensure long-term durability under in vivo conditions. Animal experiments using SCI rats were conducted to demonstrate the functionality of the device, including long-term usability and therapeutic effects. The developed system can be tailored to individual user needs with commercially available components, thus providing a cost-effective solution for large-scale long-term animal studies on neuropathic pain relief.
- Open Access
- 28 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 747
Direct Numerical Simulation of Surface Wrinkling for Extraction of Thin Metal Film Material Properties
This paper presents a direct numerical simulation for the extraction of material properties based on thin-film wrinkling on scotch tape. Conventional FEM-based buckling simulation sometimes requires complex modeling techniques concerning mesh element manipulation or boundary conditions. The direct numerical simulation differs from FEM (finite element method)-based conventional two-step linear–nonlinear buckling simulation in that mechanical imperfections are directly applied into the elements of the simulation model. Hence, it can be performed in one step to find the wrinkling wavelength and amplitude, which are key parameters to extract the material mechanical properties. Moreover, the direct simulation can reduce simulation time and modeling complexity. Using the direct model, the effect of the number of imperfections on wrinkling characteristics was first studied, and then wrinkling wavelengths depending on the elastic moduli of the associated materials were prepared for the extraction of material properties. Thin-film wrinkling test patterns on scotch tape were fabricated using the transfer technique with low adhesion between metal films and the polyimide substrate. The material properties of the thin metal films were determined by comparing the measured wrinkling wavelengths and the proposed direct simulation results. By consequence, the elastic moduli of 300 nm thick gold film and 300 nm thick aluminum were determined as 250 GPa and 300 GPa, respectively.
- 28 March 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (4) , 747
Open AccessDirect Numerical Simulation of Surface Wrinkling for Extraction of Thin Metal Film Material Properties
This paper presents a direct numerical simulation for the extraction of material properties based on thin-film wrinkling on scotch tape. Conventional FEM-based buckling simulation sometimes requires complex modeling techniques concerning mesh element manipulation or boundary conditions. The direct numerical simulation differs from FEM (finite element method)-based conventional two-step linear–nonlinear buckling simulation in that mechanical imperfections are directly applied into the elements of the simulation model. Hence, it can be performed in one step to find the wrinkling wavelength and amplitude, which are key parameters to extract the material mechanical properties. Moreover, the direct simulation can reduce simulation time and modeling complexity. Using the direct model, the effect of the number of imperfections on wrinkling characteristics was first studied, and then wrinkling wavelengths depending on the elastic moduli of the associated materials were prepared for the extraction of material properties. Thin-film wrinkling test patterns on scotch tape were fabricated using the transfer technique with low adhesion between metal films and the polyimide substrate. The material properties of the thin metal films were determined by comparing the measured wrinkling wavelengths and the proposed direct simulation results. By consequence, the elastic moduli of 300 nm thick gold film and 300 nm thick aluminum were determined as 250 GPa and 300 GPa, respectively.
- Open Access
- 24 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (6) , 6377-6385
Investigation of FBG Linear/Angular Acceleration Sensor for Novel Type Inertial Measurement
A novel inertial measurement unit (IMU) was proposed to measure the three-axis linear/angular acceleration of a body using six fiber Bragg grating (FBG) optical fiber acceleration sensors sharing the same rotational center. The six acceleration sensors were shown to accurately distinguish between movements in different directions using a vibration generator and rotary motor/encoder device. The results also indicated that the measurement range of the FBG linear acceleration sensor was ±14 g, its average sensitivity was approximately 229.4 pm/g, and its nonlinearity was under 0.05%. Furthermore, the average sensitivity and nonlinearity of the FBG angular acceleration sensor were 21°/s 2 /pm and 0.23%, respectively. When measuring linear and angular acceleration, the cross-axis sensitivity of the IMU was within 2.0%. The measurement accuracy of the roll and pitch angle during 360° rotation as well as that of the yaw angle during 720° rotation were both in the range of 0.54%–1.31%. Most of results indicated that the FBG-based IMU sensor was within the performance specifications of an equivalent conventional IMU sensor. Thus, the concept underlying the proposed sensor can be confidently used as a basis to develop a high-precision IMU sensor that is unaffected by electromagnetic interference.
- 24 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (6) , 6377-6385
Open AccessInvestigation of FBG Linear/Angular Acceleration Sensor for Novel Type Inertial Measurement
A novel inertial measurement unit (IMU) was proposed to measure the three-axis linear/angular acceleration of a body using six fiber Bragg grating (FBG) optical fiber acceleration sensors sharing the same rotational center. The six acceleration sensors were shown to accurately distinguish between movements in different directions using a vibration generator and rotary motor/encoder device. The results also indicated that the measurement range of the FBG linear acceleration sensor was ±14 g, its average sensitivity was approximately 229.4 pm/g, and its nonlinearity was under 0.05%. Furthermore, the average sensitivity and nonlinearity of the FBG angular acceleration sensor were 21°/s 2 /pm and 0.23%, respectively. When measuring linear and angular acceleration, the cross-axis sensitivity of the IMU was within 2.0%. The measurement accuracy of the roll and pitch angle during 360° rotation as well as that of the yaw angle during 720° rotation were both in the range of 0.54%–1.31%. Most of results indicated that the FBG-based IMU sensor was within the performance specifications of an equivalent conventional IMU sensor. Thus, the concept underlying the proposed sensor can be confidently used as a basis to develop a high-precision IMU sensor that is unaffected by electromagnetic interference.