João Marcos Madurro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
João Marcos Madurro has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Ana Graci Brito Madurro
Institute of Biotechnology, Federal University of Uberlândia, Uberlândia, Brazil
17 shared publications - Lucas Franco Ferreira
Institute of Science and Technology, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, MG, Brazil
6 shared publications Anna C.R. Moço
Institute of Biotechnology, Federal University of Uberlândia, 38405-319, Uberlândia, Minas Gerais, Brazil
3 shared publications- Diego Leoni Franco
Chemistry Institute, Federal University of Uberlândia (UFU), Patos de Minas 38700-002, MG, Brazil
3 shared publications - José Manuel Rodrigueiro Flauzino
Department of Bioengineering, Royal School of Mines, Imperial College London, London, UK
3 shared publications Ana G. Brito-Madurro
Institute of Biotechnology, Federal University of Uberlândia, 38405-319, Uberlândia, Minas Gerais, Brazil
2 shared publications
Latest Publications
- Open Access
- 17 November 2026
- Published by Springer Nature in Journal of Solid State Electrochemistry
- p. 1-17
Distinct interfacial effects of a CNT-AuNPs nanocomposite on commercial and lab-made screen-printed carbon electrodes
- 17 November 2026
- Published by Springer Nature in Journal of Solid State Electrochemistry
- p. 1-17
Open AccessDistinct interfacial effects of a CNT-AuNPs nanocomposite on commercial and lab-made screen-printed carbon electrodes
- 6 April 2026
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 277, 117499
Methyl orange-enhanced DNA hybridization: A gene sensor approach for hepatitis delta detection
- 6 April 2026
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 277, 117499
Methyl orange-enhanced DNA hybridization: A gene sensor approach for hepatitis delta detection
- Open Access
- 7 December 2025
- Published by Wiley in Electroanalysis
- Vol. 37 (12)
Advanced Electrochemical Genosensor for Zika Virus Detection in Biological Samples Based on Cysteamine‐Graphene Quantum Dots Bilayer
This paper describes a novel electrochemical genosensor designed for rapid and simplified detection of Zika virus DNA, using the biological dye safranin as a biomolecular intercalator. The genosensor uses a gold‐printed circuit board as electrode, modified with a bilayer formed by cysteamine and graphene quantum dots to immobilize oligonucleotide probes specifically designed for the detection of the Zika virus. The genosensor construction was monitored by scanning electron microscopy (SEM), dynamic force microscope (DFM), and Fourier transform infrared (FTIR). Electrochemical detection was carried out based on differential pulse voltammetry, monitoring the peak current of the DNA intercalator (safranin). The genosensor demonstrated high sensitivity, detecting 1.2 pg mL −1 , selectivity against other arboviruses (chikungunya and dengue) and good stability for at least 45 days. These parameters indicate potential for use of this genosensor in medical diagnostic testing for Zika virus, aiming at early screening of patients, especially in epidemic situations.
- 7 December 2025
- Published by Wiley in Electroanalysis
- Vol. 37 (12)
Open AccessAdvanced Electrochemical Genosensor for Zika Virus Detection in Biological Samples Based on Cysteamine‐Graphene Quantum Dots Bilayer
This paper describes a novel electrochemical genosensor designed for rapid and simplified detection of Zika virus DNA, using the biological dye safranin as a biomolecular intercalator. The genosensor uses a gold‐printed circuit board as electrode, modified with a bilayer formed by cysteamine and graphene quantum dots to immobilize oligonucleotide probes specifically designed for the detection of the Zika virus. The genosensor construction was monitored by scanning electron microscopy (SEM), dynamic force microscope (DFM), and Fourier transform infrared (FTIR). Electrochemical detection was carried out based on differential pulse voltammetry, monitoring the peak current of the DNA intercalator (safranin). The genosensor demonstrated high sensitivity, detecting 1.2 pg mL −1 , selectivity against other arboviruses (chikungunya and dengue) and good stability for at least 45 days. These parameters indicate potential for use of this genosensor in medical diagnostic testing for Zika virus, aiming at early screening of patients, especially in epidemic situations.
- 30 January 2025
- Published by Springer Nature in Chemical Papers
- Vol. 79 (4) , 2091-2104
Electropolymerization of p-anisidine: influence of pH on electrosynthesis
- 30 January 2025
- Published by Springer Nature in Chemical Papers
- Vol. 79 (4) , 2091-2104
Electropolymerization of p-anisidine: influence of pH on electrosynthesis
- 17 August 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 161, 108798
Advancement in SARS-CoV-2 diagnosis: A new and stable electrochemical biosensor for genomic RNA detection
- 17 August 2024
- Published by Elsevier in Bioelectrochemistry
- Vol. 161, 108798
Advancement in SARS-CoV-2 diagnosis: A new and stable electrochemical biosensor for genomic RNA detection
- Open Access
- 31 October 2023
- Published by Universidade Federal do Triangulo Minero in Revista Brasileira de Ciência, Tecnologia e Inovação
- Vol. 8 (1) , 14-29
Immunosensor for bovine anaplasmosis diagnosis on graphite platform functionalized with poly (3-hydroxybenzoic acid)
This study describe the development of an electrochemical immunosensor with a transducer platform functionalized with the poly-(3- hydroxybenzoic acid), to detection of antibodies against the surface protein (Am1) of Anaplasma marginale. This biological probe was immobilized on the polymer under graphite and characterized electrochemically. The detections of antigen-antibody interactions were conducted using the signal obtained from the oxidation of 4-aminoantipyrine (4 -AAP), interleaved with Am1, to enable the use of voltammetry technique of differential pulse. The detections of antibodies of A. marginale, using the graphite electrode functionalized with the probe Am1 was 66% higher than the graphite electrode not functionalized. The time of storage of the immunosensor was satisfactory, with reduced peak current by 35%, after 90 days. The results demonstrate the excellent applicability of this new functionalized platform for probe immobilization and diagnosis of anaplasmosis without the interference of the most similar bovine diseases
- 31 October 2023
- Published by Universidade Federal do Triangulo Minero in Revista Brasileira de Ciência, Tecnologia e Inovação
- Vol. 8 (1) , 14-29
Open AccessImmunosensor for bovine anaplasmosis diagnosis on graphite platform functionalized with poly (3-hydroxybenzoic acid)
This study describe the development of an electrochemical immunosensor with a transducer platform functionalized with the poly-(3- hydroxybenzoic acid), to detection of antibodies against the surface protein (Am1) of Anaplasma marginale. This biological probe was immobilized on the polymer under graphite and characterized electrochemically. The detections of antigen-antibody interactions were conducted using the signal obtained from the oxidation of 4-aminoantipyrine (4 -AAP), interleaved with Am1, to enable the use of voltammetry technique of differential pulse. The detections of antibodies of A. marginale, using the graphite electrode functionalized with the probe Am1 was 66% higher than the graphite electrode not functionalized. The time of storage of the immunosensor was satisfactory, with reduced peak current by 35%, after 90 days. The results demonstrate the excellent applicability of this new functionalized platform for probe immobilization and diagnosis of anaplasmosis without the interference of the most similar bovine diseases
- 24 November 2022
- Published by Wiley in Journal of Molecular Recognition
- Vol. 36 (2) , e2995
Electro‐immunosensor for ultra‐sensitive determination of cardiac troponin I based on reduced graphene oxide and polytyramine
This work reports the construction of a novel nanostructured immunosensor for detection of the troponin I biomarker (cTnI). Anti‐troponin I antibody was anchored on the modified graphite electrode with reduced graphene oxide and polytyramine for detection of troponin I in serum samples. The performance of the electro‐immunosensor was evaluated by differential pulse voltammetry. The immunosensor presented a wide work range, from 4 ng mL−1 to 4 pg mL−1, whose detection limit (4 pg mL−1) is significantly lower than the basal level in human serum, and maintained 100% of response after 30 days of storage. Moreover, the immunosensor showed good selectivity for detection of cTnI in real sample containing interfering substances and specificity of response to cTnI in the serum of healthy and sick patients, and demonstrated the possibility of reuse for two consecutive analyses, in addition to using a simplified and inexpensive platform when compared to other devices, demonstrating them excellent potential for application in diagnosis in the early stages of acute myocardial infarction.
- 24 November 2022
- Published by Wiley in Journal of Molecular Recognition
- Vol. 36 (2) , e2995
Electro‐immunosensor for ultra‐sensitive determination of cardiac troponin I based on reduced graphene oxide and polytyramine
This work reports the construction of a novel nanostructured immunosensor for detection of the troponin I biomarker (cTnI). Anti‐troponin I antibody was anchored on the modified graphite electrode with reduced graphene oxide and polytyramine for detection of troponin I in serum samples. The performance of the electro‐immunosensor was evaluated by differential pulse voltammetry. The immunosensor presented a wide work range, from 4 ng mL−1 to 4 pg mL−1, whose detection limit (4 pg mL−1) is significantly lower than the basal level in human serum, and maintained 100% of response after 30 days of storage. Moreover, the immunosensor showed good selectivity for detection of cTnI in real sample containing interfering substances and specificity of response to cTnI in the serum of healthy and sick patients, and demonstrated the possibility of reuse for two consecutive analyses, in addition to using a simplified and inexpensive platform when compared to other devices, demonstrating them excellent potential for application in diagnosis in the early stages of acute myocardial infarction.