Oladepo Olatunde
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Oladepo Olatunde has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Adewale Obaro
Department of Electrical Engineering Faculty of Engineering and the Built Environment Tshwane University of Technology Pretoria South Africa tut.ac.za
1 shared publication - Akintunde Samson Alayande
Department of Electrical and Electronics Engineering University of Lagos Akoka 100213 Lagos Nigeria
1 shared publication Amodu A. Olamide
Osun State University, Nigeria
1 shared publicationAwofolaju Tolulope Tola
Osun State University
1 shared publicationFaleti I. Olufemi
Osun State University, Nigeria
1 shared publicationGabriel A Adegboyega
1 shared publication
Latest Publications
- Open Access
- 30 November 2024
- Published by Universitas Ahmad Dahlan in Buletin Ilmiah Sarjana Teknik Elektro
- Vol. 6 (4) , 366-380
Multiagent based Power Management for Grid-connected Photovoltaic Source Using the Optimized Network Parameters From Butterworth Inertia Weight Particle Swarm Optimization
An efficient power management technique of a grid-connected renewable source proficiently coordinates the various controllable units necessary in the power system operation. It is achieved by responding to the dynamic load demand through efficient communication and advanced control structures. This paper presents a decentralized multiagent power management technique for a grid-connected photovoltaic/energy storage system using the optimized network parameters from the Butterworth inertial weight particle swarm optimization method. The power network is coordinated by intelligent agents and structured into a zonal generation and load multiagent system to update the load and power injected at different network buses. However, Butterworth inertial weighting function particle swarm optimization determines the optimized network parameters and the capacity of the connected energy sources fed into the multiagent system. The inertial weight of the optimization technique is patterned along the Butterworth filtering curve for holistic space search and improved convergence. Hence, the proposed technique solves the problem of inefficient optimization methods and provides a robust control and management system with agents capable of reorganizing and coping with the system's dynamic changes. The performance analysis of the IEEE 33-Bus distribution system shows an improved network coordinating method. The power loss reduction appreciated significantly from 65.42% to 68.58%, while the voltage deviation improved from 88.19% to 89.95% by integrating a renewable battery system. The voltage is maintained within the operational constraints of daily simulations. The method is targeted at efficient operation of distribution networks.
- 30 November 2024
- Published by Universitas Ahmad Dahlan in Buletin Ilmiah Sarjana Teknik Elektro
- Vol. 6 (4) , 366-380
Open AccessMultiagent based Power Management for Grid-connected Photovoltaic Source Using the Optimized Network Parameters From Butterworth Inertia Weight Particle Swarm Optimization
An efficient power management technique of a grid-connected renewable source proficiently coordinates the various controllable units necessary in the power system operation. It is achieved by responding to the dynamic load demand through efficient communication and advanced control structures. This paper presents a decentralized multiagent power management technique for a grid-connected photovoltaic/energy storage system using the optimized network parameters from the Butterworth inertial weight particle swarm optimization method. The power network is coordinated by intelligent agents and structured into a zonal generation and load multiagent system to update the load and power injected at different network buses. However, Butterworth inertial weighting function particle swarm optimization determines the optimized network parameters and the capacity of the connected energy sources fed into the multiagent system. The inertial weight of the optimization technique is patterned along the Butterworth filtering curve for holistic space search and improved convergence. Hence, the proposed technique solves the problem of inefficient optimization methods and provides a robust control and management system with agents capable of reorganizing and coping with the system's dynamic changes. The performance analysis of the IEEE 33-Bus distribution system shows an improved network coordinating method. The power loss reduction appreciated significantly from 65.42% to 68.58%, while the voltage deviation improved from 88.19% to 89.95% by integrating a renewable battery system. The voltage is maintained within the operational constraints of daily simulations. The method is targeted at efficient operation of distribution networks.
- Open Access
- 18 April 2022
- Published by Universitas Muhammadiyah Magelang in Mechanical Engineering for Society and Industry
- Vol. 2 (2) , 57-63
Mathematical modeling and cost comparison for electricity generation from petrol and liquified petroleum gas (LPG)
This study investigates and compares the cost of generating electricity from petrol and liquified petroleum gas (LPG) gas using a 2.5 kVA, 50Hz Elepaq generator. It also develops mathematical models that can be used to predict important parameters of the generator The generator is connected with a multi-fuel carburetor in the experimental setup, allowing both fuel sources to be fed alternatively. The electric bulbs of different ratings were connected and varied as load. The generator was first run using petrol. The time used to exhaust half litres of petrol was recorded. It was then run with LPG for a period equal to the time of run on petrol, taking note of the mass of LPG consumed. A cost comparison was carried out and mathematical models were developed for both fuels usage using MATLAB “polyfit” command. The results show that with less or equal 1350W connection of purely resistive load. It is more economical to run the generator using LPG. However, at any load beyond 1350 W, it is economical to run the generator using petrol. The two models developed best fit the experimental results obtained with a correlation of 0.9869 and 0.9962.
- 18 April 2022
- Published by Universitas Muhammadiyah Magelang in Mechanical Engineering for Society and Industry
- Vol. 2 (2) , 57-63
Open AccessMathematical modeling and cost comparison for electricity generation from petrol and liquified petroleum gas (LPG)
This study investigates and compares the cost of generating electricity from petrol and liquified petroleum gas (LPG) gas using a 2.5 kVA, 50Hz Elepaq generator. It also develops mathematical models that can be used to predict important parameters of the generator The generator is connected with a multi-fuel carburetor in the experimental setup, allowing both fuel sources to be fed alternatively. The electric bulbs of different ratings were connected and varied as load. The generator was first run using petrol. The time used to exhaust half litres of petrol was recorded. It was then run with LPG for a period equal to the time of run on petrol, taking note of the mass of LPG consumed. A cost comparison was carried out and mathematical models were developed for both fuels usage using MATLAB “polyfit” command. The results show that with less or equal 1350W connection of purely resistive load. It is more economical to run the generator using LPG. However, at any load beyond 1350 W, it is economical to run the generator using petrol. The two models developed best fit the experimental results obtained with a correlation of 0.9869 and 0.9962.
- 21 March 2022
- Published by Wiley in Energy Storage
- Vol. 4 (4)
Optimum utilization of grid‐connected hybrid power system using hybrid particle swarm optimization/whale optimization algorithm
Network management and optimization play a crucial role in integrating renewable energy sources on the distribution network. This paper presents the optimization of the grid‐connected photovoltaic/small hydropower hybrid power system using a hybrid particle swarm optimization‐whale optimization algorithm. The exploration strength of the particle swarm optimization is hybridized with the exploitation capability of the whale optimization algorithm for improved convergence, speed, and optimal network performance. The objective function is to minimize the feeder voltage deviation and power loss. The effectiveness of the proposed approach is verified on the standard 118—bus distribution system. The simulation is carried out with step changes in irradiation and loading conditions. The optimization result from the two hybridized algorithms is compared to its standalone form, simulated under the same conditions. The results show that the proposed method is superior in the optimal solution and convergence property. The results confirm the technique's contribution to improved network management and grid‐connected hybrid renewable power systems. It significantly reduced the voltage deviation by 62.58% on multiple locations of renewable sources. The voltage is achieved within the statutory range at all hours of the daily simulation. The technique is envisaged to be very useful in distribution network operators.
- 21 March 2022
- Published by Wiley in Energy Storage
- Vol. 4 (4)
Optimum utilization of grid‐connected hybrid power system using hybrid particle swarm optimization/whale optimization algorithm
Network management and optimization play a crucial role in integrating renewable energy sources on the distribution network. This paper presents the optimization of the grid‐connected photovoltaic/small hydropower hybrid power system using a hybrid particle swarm optimization‐whale optimization algorithm. The exploration strength of the particle swarm optimization is hybridized with the exploitation capability of the whale optimization algorithm for improved convergence, speed, and optimal network performance. The objective function is to minimize the feeder voltage deviation and power loss. The effectiveness of the proposed approach is verified on the standard 118—bus distribution system. The simulation is carried out with step changes in irradiation and loading conditions. The optimization result from the two hybridized algorithms is compared to its standalone form, simulated under the same conditions. The results show that the proposed method is superior in the optimal solution and convergence property. The results confirm the technique's contribution to improved network management and grid‐connected hybrid renewable power systems. It significantly reduced the voltage deviation by 62.58% on multiple locations of renewable sources. The voltage is achieved within the statutory range at all hours of the daily simulation. The technique is envisaged to be very useful in distribution network operators.
- Open Access
- 1 January 2021
- Published by RS Publication in International Journal of Emerging Trends in Engineering and Development
- Vol. 5 (11)
VOLTAGE STABILITY ASSESSMENT IN A POWER SYSTEM USING SINGULAR VALUE DECOMPOSITION TECHNIQUE
- 1 January 2021
- Published by RS Publication in International Journal of Emerging Trends in Engineering and Development
- Vol. 5 (11)
Open AccessVOLTAGE STABILITY ASSESSMENT IN A POWER SYSTEM USING SINGULAR VALUE DECOMPOSITION TECHNIQUE
- 1 September 2020
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (9)
Real-time multiperiod voltage control algorithm with OLTC and switched capacitors for smart distribution networks in the presence of energy storage system
Conventionally, voltage profile are regulated by controllers that are not operational flexible to the system dynamism and challenges offered by the integration of renewable energy sources. Consequently, there is a need for the adaptive coordinating mechanism as an interface between the passive network and the new active network. This will provide a platform for the smooth integration of distributed energy resources in most developing countries where traditional network is still operational. This paper proposes an algorithm for real-time multiperiod adaptive compensation of network reactive power support based on hierarchical structure and decentralized layered multiagent system voltage coordinating scheme. A multiperiod voltage control algorithm replicates the daily load flow evaluation aiming at ameliorating voltage fluctuation over a 24-hour simulation period. The algorithm applies the decentralized voltage control mechanism to monitor the network parameters and dynamically evaluate the capacity of the capacitor banks (CBs) to be injected for voltage compensation. This mitigates the challenges associated with under and over reactive power compensation experienced in the day-ahead programming and manual switching operation. The algorithm works in conjunction with an on-load tap changing transformer (OLTC) and energy storage system (ESS). The ESS complements the OLTC during switching delay, dip in its output root mean square and voltage fluctuation as network loading condition varies. The effectiveness of the proposed method is verified on standard IEEE 33 and 118-bus distribution systems. The results show an improved voltage performance and reduction in stress/complexity associated with load and renewable generation forecast in manual switching operations.
- 1 September 2020
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (9)
Real-time multiperiod voltage control algorithm with OLTC and switched capacitors for smart distribution networks in the presence of energy storage system
Conventionally, voltage profile are regulated by controllers that are not operational flexible to the system dynamism and challenges offered by the integration of renewable energy sources. Consequently, there is a need for the adaptive coordinating mechanism as an interface between the passive network and the new active network. This will provide a platform for the smooth integration of distributed energy resources in most developing countries where traditional network is still operational. This paper proposes an algorithm for real-time multiperiod adaptive compensation of network reactive power support based on hierarchical structure and decentralized layered multiagent system voltage coordinating scheme. A multiperiod voltage control algorithm replicates the daily load flow evaluation aiming at ameliorating voltage fluctuation over a 24-hour simulation period. The algorithm applies the decentralized voltage control mechanism to monitor the network parameters and dynamically evaluate the capacity of the capacitor banks (CBs) to be injected for voltage compensation. This mitigates the challenges associated with under and over reactive power compensation experienced in the day-ahead programming and manual switching operation. The algorithm works in conjunction with an on-load tap changing transformer (OLTC) and energy storage system (ESS). The ESS complements the OLTC during switching delay, dip in its output root mean square and voltage fluctuation as network loading condition varies. The effectiveness of the proposed method is verified on standard IEEE 33 and 118-bus distribution systems. The results show an improved voltage performance and reduction in stress/complexity associated with load and renewable generation forecast in manual switching operations.