Franziska Hagemann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Franziska Hagemann has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- John Linkhorst
Process Engineering of Electrochemical Systems Technical University Darmstadt Darmstadt Germany
2 shared publications - Matthias Wessling
Chemical Process Engineering RWTH Aachen University Aachen Germany
2 shared publications Alexander Theißen
Department of Anesthesiology University Hospital Aachen Pauwelsstr. 30 52074 Aachen Germany
1 shared publication- Bettina Wiegmann
Department for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
1 shared publication - Christian Bleilevens
Department of Anesthesiology, Faculty of Medicine, University Hospital RWTH Aachen, 52074 Aachen, Germany
1 shared publication Erik Ortmann
1 shared publication
Latest Publications
- Open Access
- 30 April 2026
- Published by Elsevier in Journal of Membrane Science
- Vol. 751
Flow distribution in single-use intravenous in-line membrane filters
- 30 April 2026
- Published by Elsevier in Journal of Membrane Science
- Vol. 751
Open AccessFlow distribution in single-use intravenous in-line membrane filters
- Open Access
- 15 November 2024
- Published by Wiley in Advanced Healthcare Materials
- Vol. 14 (2) , e2403111
Enhanced Hemodynamics of Anisometric TPMS Topology Reduce Blood Clotting in 3D Printed Blood Contactors
Artificial organs, such as extracorporeal membrane oxygenators, dialyzers, and hemoadsorber cartridges, face persistent challenges related to the flow distribution within the cartridge. This uneven flow distribution leads to clot formation and inefficient mass transfer over the device's functional surface. In this work, a comprehensive methodology is presented for precisely integrating triply periodic minimal surfaces (TPMS) into module housings and question whether the internal surface topology determining the flow distribution affects blood coagulation. Three module types are compared with different internal topologies: tubular, isometric, and anisometric TPMS. First, this study includes a computational fluid dynamics (CFD) simulation of the internal hemodynamics, validated through experimental residence time distributions (RTD). Blood tests using human whole blood and subsequent visualization of blood clots by computed tomography, allow the quantification of structure‐induced blood clotting. The results indicate that TPMS topologies, particularly anisometric ones, serve as effective flow distributors and significantly reduce and delay blood clotting compared to conventional tubular geometries. For these novel TPMS modules, the inner surfaces can be activated chemically or functionalized to function as a selective adsorption site or biocatalytic surface or made of a permeable material to facilitate mass transfer.
- 15 November 2024
- Published by Wiley in Advanced Healthcare Materials
- Vol. 14 (2) , e2403111
Open AccessEnhanced Hemodynamics of Anisometric TPMS Topology Reduce Blood Clotting in 3D Printed Blood Contactors
Artificial organs, such as extracorporeal membrane oxygenators, dialyzers, and hemoadsorber cartridges, face persistent challenges related to the flow distribution within the cartridge. This uneven flow distribution leads to clot formation and inefficient mass transfer over the device's functional surface. In this work, a comprehensive methodology is presented for precisely integrating triply periodic minimal surfaces (TPMS) into module housings and question whether the internal surface topology determining the flow distribution affects blood coagulation. Three module types are compared with different internal topologies: tubular, isometric, and anisometric TPMS. First, this study includes a computational fluid dynamics (CFD) simulation of the internal hemodynamics, validated through experimental residence time distributions (RTD). Blood tests using human whole blood and subsequent visualization of blood clots by computed tomography, allow the quantification of structure‐induced blood clotting. The results indicate that TPMS topologies, particularly anisometric ones, serve as effective flow distributors and significantly reduce and delay blood clotting compared to conventional tubular geometries. For these novel TPMS modules, the inner surfaces can be activated chemically or functionalized to function as a selective adsorption site or biocatalytic surface or made of a permeable material to facilitate mass transfer.
- 1 August 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1626, 461319
Modeling hindered diffusion of antibodies in agarose beads considering pore size reduction due to adsorption
- 1 August 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1626, 461319
Modeling hindered diffusion of antibodies in agarose beads considering pore size reduction due to adsorption