Brodie William Hobson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Brodie William Hobson has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
H. Burak Gunay
6 shared publications- Andre A. Markus
Department of Civil and Environmental Engineering, Carleton University, Ottawa, ON, Canada
4 shared publications Burak Gunay
4 shared publications- Burak Gunay
Carleton University, Ottawa, Canada
2 shared publications Darwish Darwazeh
National Research Council
2 shared publicationsGuy R. Newsham
2 shared publications
Latest Publications
- 8 October 2026
- Published by Springer Nature
- p. 410-424
Developing a Validation Framework for Virtual Home Energy Labelling: Insights from Stakeholder Interviews and a Literature Review
- 8 October 2026
- Published by Springer Nature
- p. 410-424
Developing a Validation Framework for Virtual Home Energy Labelling: Insights from Stakeholder Interviews and a Literature Review
- Open Access
- 27 March 2026
- Published by Elsevier in Energy and Buildings
- Vol. 360
Evaluation of electric heating systems in Canadian residential buildings
- 27 March 2026
- Published by Elsevier in Energy and Buildings
- Vol. 360
Open AccessEvaluation of electric heating systems in Canadian residential buildings
- Open Access
- 26 August 2025
- Published by Elsevier in Building and Environment
- Vol. 285
Do homebuyers prioritize sustainability? Examining the GHG emission impact of housing choices
- 26 August 2025
- Published by Elsevier in Building and Environment
- Vol. 285
Open AccessDo homebuyers prioritize sustainability? Examining the GHG emission impact of housing choices
- Open Access
- 10 June 2025
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 46 (6) , 775-791
Deriving optimal direct load control sequences for HVAC systems of small commercial buildings
Direct load control (DLC) for building HVAC systems, through preconditioning and setup/setback sequences, can substantially reduce electricity consumption during peak periods. Yet, the effectiveness of a DLC sequence strictly depends on the thermophysical attributes of a building and its occupants’ tolerance to variations in the thermal environment. The current one-size-fits-all approach to DLC disregards the inter-building diversity of these factors. This paper demonstrates the inter-building diversity of preconditioning and setup/setback needs by deriving unique DLC sequences for different buildings. To this end, variants of an EnergyPlus model representing a small commercial building in Toronto, Ontario are created by altering its envelope, HVAC capacity, and occupants’ temperature preference characteristics. Through a metaheuristic search, personalized DLC sequences that minimize the HVAC-related electricity costs and the time spent outside a preferred temperature range are estimated for each variant. These personalized DLC sequences were compared with six baseline DLC sequences. Unlike the baseline DLC sequences, the optimal sequences could attain an average of 20% reduction in HVAC-related electricity costs while keeping the time spent outside the preferred temperature ranges under 3% for all variants. Practical application: This paper presents an optimization method to derive unique direct load control sequences demonstrating the inter-building diversity of preconditioning and setup/setback needs. The method is tested on a range of buildings with varying characteristics in a simulation environment. The findings of the study are useful in the domains of HVAC controls, demand response, and electrification of HVAC systems.
- 10 June 2025
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 46 (6) , 775-791
Open AccessDeriving optimal direct load control sequences for HVAC systems of small commercial buildings
Direct load control (DLC) for building HVAC systems, through preconditioning and setup/setback sequences, can substantially reduce electricity consumption during peak periods. Yet, the effectiveness of a DLC sequence strictly depends on the thermophysical attributes of a building and its occupants’ tolerance to variations in the thermal environment. The current one-size-fits-all approach to DLC disregards the inter-building diversity of these factors. This paper demonstrates the inter-building diversity of preconditioning and setup/setback needs by deriving unique DLC sequences for different buildings. To this end, variants of an EnergyPlus model representing a small commercial building in Toronto, Ontario are created by altering its envelope, HVAC capacity, and occupants’ temperature preference characteristics. Through a metaheuristic search, personalized DLC sequences that minimize the HVAC-related electricity costs and the time spent outside a preferred temperature range are estimated for each variant. These personalized DLC sequences were compared with six baseline DLC sequences. Unlike the baseline DLC sequences, the optimal sequences could attain an average of 20% reduction in HVAC-related electricity costs while keeping the time spent outside the preferred temperature ranges under 3% for all variants. Practical application: This paper presents an optimization method to derive unique direct load control sequences demonstrating the inter-building diversity of preconditioning and setup/setback needs. The method is tested on a range of buildings with varying characteristics in a simulation environment. The findings of the study are useful in the domains of HVAC controls, demand response, and electrification of HVAC systems.
- Open Access
- 9 December 2024
- Published by Elsevier in Energy and Buildings
- Vol. 328
Projecting and estimating HVAC energy savings from correcting control faults: Comparison between physical and virtual metering approaches
- 9 December 2024
- Published by Elsevier in Energy and Buildings
- Vol. 328
Open AccessProjecting and estimating HVAC energy savings from correcting control faults: Comparison between physical and virtual metering approaches
- 12 September 2023
- Published by Elsevier in Energy and Buildings
- Vol. 298
Minimum sensor grid density and configuration to enable CO2-based demand-controlled ventilation in an office building
- 12 September 2023
- Published by Elsevier in Energy and Buildings
- Vol. 298
Minimum sensor grid density and configuration to enable CO2-based demand-controlled ventilation in an office building
- 18 January 2023
- Published by Elsevier in Energy and Buildings
- Vol. 282
Estimating energy savings from HVAC controls fault correction through inverse greybox model-based virtual metering
- 18 January 2023
- Published by Elsevier in Energy and Buildings
- Vol. 282
Estimating energy savings from HVAC controls fault correction through inverse greybox model-based virtual metering
- Open Access
- 7 November 2022
- Published by Association for Computing Machinery (ACM)
- p. 104-111
Occupancy Estimation Using Sparse Sensor Coverage
Estimation of occupant count in commercial and institutional buildings enables energy experts to make better decisions on which buildings to prioritize for green upgrading and retrofitting from a large building portfolio. A cheap easy-to-install solution will enable energy experts to obtain occupancy estimation by easily scaling to large building portfolios. This paper presents a method for estimating occupancy based on sparse coverage of low-cost IoT sensors. The method is tested on 2 datasets, one academic building in Denmark (DK) and one academic building in Canada (CAN). The datasets contain PIR, CO2 measurements, and electric energy data together with ground truth occupancy counts. We show that 20% sensor coverage is comparable to full sensor coverage (60%) with an NRMSE of 0.142 (DK) and 0.174 (CAN) for 20% sensor coverage and an NRMSE of 0.129 (DK) and 0.163 (CAN) for full sensor coverage. Results show that with less sensor coverage, sensor placement becomes more important and that even with 20% it is possible to get as good of an accuracy as full coverage. The occupant count is used for key performance indicators of the buildings’ energy usage which shows higher energy use per occupant at low occupancy.
- 7 November 2022
- Published by Association for Computing Machinery (ACM)
- p. 104-111
Open AccessOccupancy Estimation Using Sparse Sensor Coverage
Estimation of occupant count in commercial and institutional buildings enables energy experts to make better decisions on which buildings to prioritize for green upgrading and retrofitting from a large building portfolio. A cheap easy-to-install solution will enable energy experts to obtain occupancy estimation by easily scaling to large building portfolios. This paper presents a method for estimating occupancy based on sparse coverage of low-cost IoT sensors. The method is tested on 2 datasets, one academic building in Denmark (DK) and one academic building in Canada (CAN). The datasets contain PIR, CO2 measurements, and electric energy data together with ground truth occupancy counts. We show that 20% sensor coverage is comparable to full sensor coverage (60%) with an NRMSE of 0.142 (DK) and 0.174 (CAN) for 20% sensor coverage and an NRMSE of 0.129 (DK) and 0.163 (CAN) for full sensor coverage. Results show that with less sensor coverage, sensor placement becomes more important and that even with 20% it is possible to get as good of an accuracy as full coverage. The occupant count is used for key performance indicators of the buildings’ energy usage which shows higher energy use per occupant at low occupancy.
- 1 November 2021
- Published by Elsevier in Energy and Buildings
- Vol. 250
A framework for a multi-source, data-driven building energy management toolkit
- 1 November 2021
- Published by Elsevier in Energy and Buildings
- Vol. 250
A framework for a multi-source, data-driven building energy management toolkit