Wei Sheng Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wei Sheng Tan has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- David A. Carter
Department of Physiology, The University of Melbourne, Victoria 3010, Australia
1 shared publication Jiali Zou
Geriatric Hospital Affiliated to Wuhan University of Science and Technology, Wuhan, China
1 shared publication- Jinsong Zhang
Nanjing Med Univ, Inst Poisoning, Nanjing 211100, Peoples R China
1 shared publication - Linda Alba Gallo
School of Biomedical Sciences, The University of Queensland
1 shared publication - Thomas P. Mullins
Mater Research Institute, The University of Queensland, South Brisbane, QLD, Australia
1 shared publication - Wenjuan Huang
Department of Internal Medicine, Harbin Medical University Cancer Hospital, Harbin Medical University, Harbin, China
1 shared publication
Latest Publications
- Open Access
- 24 August 2023
- Published by Springer Nature in Lipids in Health and Disease
- Vol. 22 (1) , 1-10
Development and validation of a nomogram prediction model for hypertension-diabetes comorbidity based on chronic disease management in the community
Purpose: Develop and validate a nomogram prediction model for hypertension-diabetes comorbidities based on chronic disease management in the community. Patients and methods: The nomogram prediction model was developed in a cohort of 7200 hypertensive patients at a community health service center in Hongshan District, Wuhan City. The data were collected from January 2022 to December 2022 and randomly divided into modeling and validation groups at a 7:3 ratio. The Lasso regression model was used for data dimensionality reduction, feature selection, and clinical test feature construction. Multivariate logistic regression analysis was used to build the prediction model. Results: The application of the nomogram in the verification group showed good discrimination, with an AUC of 0.9205 (95% CI: 0.8471–0.9527) and a good calibration effect. Decision curve analysis demonstrated that the predictive model was clinically useful. Conclusion: This study presents a nomogram prediction model that incorporates age, waist-height ratio and elevated density lipoprotein cholesterol (HDL-CHOLESTEROL), which can be used to predict the risk of codeveloping diabetes in hypertensive patients.
- 24 August 2023
- Published by Springer Nature in Lipids in Health and Disease
- Vol. 22 (1) , 1-10
Open AccessDevelopment and validation of a nomogram prediction model for hypertension-diabetes comorbidity based on chronic disease management in the community
Purpose: Develop and validate a nomogram prediction model for hypertension-diabetes comorbidities based on chronic disease management in the community. Patients and methods: The nomogram prediction model was developed in a cohort of 7200 hypertensive patients at a community health service center in Hongshan District, Wuhan City. The data were collected from January 2022 to December 2022 and randomly divided into modeling and validation groups at a 7:3 ratio. The Lasso regression model was used for data dimensionality reduction, feature selection, and clinical test feature construction. Multivariate logistic regression analysis was used to build the prediction model. Results: The application of the nomogram in the verification group showed good discrimination, with an AUC of 0.9205 (95% CI: 0.8471–0.9527) and a good calibration effect. Decision curve analysis demonstrated that the predictive model was clinically useful. Conclusion: This study presents a nomogram prediction model that incorporates age, waist-height ratio and elevated density lipoprotein cholesterol (HDL-CHOLESTEROL), which can be used to predict the risk of codeveloping diabetes in hypertensive patients.
- 16 March 2020
- Published by Wiley in Nephrology
- Vol. 25 (7) , 575-581
Validation of non‐invasive transcutaneous measurement for glomerular filtration rate in lean and obese C57BL/6J mice
Aim: The measurement of glomerular filtration rate (GFR) in experimental rodents is pivotal to understanding the progression of kidney disease and benefits of treatment strategies. A non‐invasive clearance device has been developed, which measures transcutaneous decay of injected FITC‐sinistrin in conscious rodents. The technique was validated against the well‐established plasma clearance method in the same mice, but on consecutive days, using only models of uninephrectomy and polycystic kidney disease. We aimed to validate this widely used technique in the same lean or obese mice, at the same time.Methods: Five‐week‐old male C57BL/6J mice were randomised to a high fat diet (n = 12) or normal diet (n = 11) for 10 weeks. Transcutaneous and plasma clearance of FITC‐sinistrin were measured simultaneously in each mouse.Results: In lean mice, there was a positive correlation between transcutaneous and plasma derived GFR (P < .01, R2 = .704), although there was an approximate 40% underestimation by the transcutaneous method (P < .0001). In obese mice, no correlation was observed between transcutaneous and plasma derived GFR, nor elimination half‐life which removes any effect of the conversion factor and injected dose. The limits of agreement in a Bland‐Altman plot were narrower when we used new conversion factors derived from mice in the current study and, in lean mice, a generic conversion factor which assumes 20% extracellular volume.Conclusion: The non‐invasive clearance device may be useful for serial GFR measurements in lean and healthy mice, provided validation studies have been carried out, but its utility in obesity requires further study.
- 16 March 2020
- Published by Wiley in Nephrology
- Vol. 25 (7) , 575-581
Validation of non‐invasive transcutaneous measurement for glomerular filtration rate in lean and obese C57BL/6J mice
Aim: The measurement of glomerular filtration rate (GFR) in experimental rodents is pivotal to understanding the progression of kidney disease and benefits of treatment strategies. A non‐invasive clearance device has been developed, which measures transcutaneous decay of injected FITC‐sinistrin in conscious rodents. The technique was validated against the well‐established plasma clearance method in the same mice, but on consecutive days, using only models of uninephrectomy and polycystic kidney disease. We aimed to validate this widely used technique in the same lean or obese mice, at the same time.Methods: Five‐week‐old male C57BL/6J mice were randomised to a high fat diet (n = 12) or normal diet (n = 11) for 10 weeks. Transcutaneous and plasma clearance of FITC‐sinistrin were measured simultaneously in each mouse.Results: In lean mice, there was a positive correlation between transcutaneous and plasma derived GFR (P < .01, R2 = .704), although there was an approximate 40% underestimation by the transcutaneous method (P < .0001). In obese mice, no correlation was observed between transcutaneous and plasma derived GFR, nor elimination half‐life which removes any effect of the conversion factor and injected dose. The limits of agreement in a Bland‐Altman plot were narrower when we used new conversion factors derived from mice in the current study and, in lean mice, a generic conversion factor which assumes 20% extracellular volume.Conclusion: The non‐invasive clearance device may be useful for serial GFR measurements in lean and healthy mice, provided validation studies have been carried out, but its utility in obesity requires further study.