Cher Heng Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cher Heng Tan has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Chusilp Charnsangavej
3 shared publicationsKian Soon Lim
2 shared publicationsLeonardo Marcal
2 shared publicationsPiyaporn Boonsirikamchai
2 shared publicationsPriya Bhosale
2 shared publicationsPriya R. Bhosale
From the Departments of *Diagnostic Radiology, †Radiation Oncology Treatment, and ‡GI Medical Oncology, University of Texas, MD Anderson Cancer Center, Houston, TX
2 shared publications
Latest Publications
- 14 September 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1131) , 20210509
Comparison of diagnostic performance and inter-reader agreement between PI-RADS v2.1 and PI-RADS v2: systematic review and meta-analysis
Objectives: To perform a systematic review and meta-analysis comparing diagnostic performance and inter reader agreement between PI-RADS v. 2.1 and PI-RADS v. 2 in the detection of clinically significant prostate cancer (csPCa). Methods: A systematic review was performed, searching the major biomedical databases (Medline, Embase, Scopus), using the keywords “PIRADS 2.1” or “PI RADS 2.1” or “PI-RADS 2.1”. Studies reporting on head-to-head diagnostic comparison between PI-RADS v. 2.1 and v. 2 were included. Pooled sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were compared between PI-RADS v. 2.1 and v. 2. Summary receiver operator characteristic graphs were plotted. Analysis was performed for whole gland, and pre-planned subgroup analysis was performed by tumour location (whole gland vs transition zone (TZ)), high b-value DWI (b-value ≥1400 s/mm2), and reader experience (<5 years vs ≥5 years with prostate MRI interpretation). Inter-reader agreement and pooled rates of csPCa for PI-RADS 1–3 lesions were compared between PI-RADS v. 2.1 and v. 2. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool v. 2 (QUADAS-2). Results: Eight studies (1836 patients, 1921 lesions) were included. Pooled specificity for PI-RADS v. 2.1 was significantly lower than PI-RADS v. 2 for whole gland (0.62 vs 0.66, p = 0.02). Pooled sensitivities, PPVs and NPVs were not significantly different (p = 0.17, 0.31, 0.41). Pooled specificity for PI-RADS v. 2.1 was significantly lower than PI-RADS v. 2 for TZ only (0.67 vs 0.72, p = 0.01). Pooled sensitivities, PPVs and NPVs were not significantly different (p = 0.06, 0.36, 0.17). Amongst studies utilising diffusion-weighted imaging with highest b-value of ≥1400 s/mm2, pooled sensitivities, specificities, PPVs and NPVs were not significantly different (p = 0.52, 0.4, 0.5, 0.47). There were no significant differences in pooled sensitivities, specificities, PPVs and NPVs between PI-RADS v. 2.1 and PI-RADS v. 2 for less-experienced readers (p = 0.65, 0.37, 0.65, 0.81) and for more experienced readers (p = 0.57, 0.90, 0.91, 0.65). For PI-RADS v. 2.1 alone, there were no significant differences in pooled sensitivity, specificity, PPV and NPV between less and more experienced readers (p = 0.38, 0.70, 1, 0.48). Inter-reader agreement was moderate to substantial for both PI-RADS v. 2.1 and v. 2. There were no significant differences between pooled csPCa rates between PI-RADS v. 2.1 and v. 2 for PI-RADS 1–2 lesions (6.6% vs 7.3%, p = 0.53), or PI-RADS 3 lesions (24.1% vs 26.8%, p = 0.28). Conclusions: Diagnostic performance and inter-reader agreement for PI-RADS v. 2.1 is comparable to PI-RADS v. 2, however the significantly lower specificity of PI-RADS v. 2.1 may result in increased number of unnecessary biopsies. Advances in knowledge: 1. Compared to PI-RADS v. 2, PI-RADS v. 2.1 has a non-significantly higher sensitivity but a significantly lower specificity for detection of clinically significant prostate cancer. 2. PI-RADS v. 2.1 could potentially result in considerable increase in number of negative targeted biopsy rates for PI-RADS 3 lesions, which could have been potentially avoided.
- 14 September 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1131) , 20210509
Comparison of diagnostic performance and inter-reader agreement between PI-RADS v2.1 and PI-RADS v2: systematic review and meta-analysis
Objectives: To perform a systematic review and meta-analysis comparing diagnostic performance and inter reader agreement between PI-RADS v. 2.1 and PI-RADS v. 2 in the detection of clinically significant prostate cancer (csPCa). Methods: A systematic review was performed, searching the major biomedical databases (Medline, Embase, Scopus), using the keywords “PIRADS 2.1” or “PI RADS 2.1” or “PI-RADS 2.1”. Studies reporting on head-to-head diagnostic comparison between PI-RADS v. 2.1 and v. 2 were included. Pooled sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were compared between PI-RADS v. 2.1 and v. 2. Summary receiver operator characteristic graphs were plotted. Analysis was performed for whole gland, and pre-planned subgroup analysis was performed by tumour location (whole gland vs transition zone (TZ)), high b-value DWI (b-value ≥1400 s/mm2), and reader experience (<5 years vs ≥5 years with prostate MRI interpretation). Inter-reader agreement and pooled rates of csPCa for PI-RADS 1–3 lesions were compared between PI-RADS v. 2.1 and v. 2. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool v. 2 (QUADAS-2). Results: Eight studies (1836 patients, 1921 lesions) were included. Pooled specificity for PI-RADS v. 2.1 was significantly lower than PI-RADS v. 2 for whole gland (0.62 vs 0.66, p = 0.02). Pooled sensitivities, PPVs and NPVs were not significantly different (p = 0.17, 0.31, 0.41). Pooled specificity for PI-RADS v. 2.1 was significantly lower than PI-RADS v. 2 for TZ only (0.67 vs 0.72, p = 0.01). Pooled sensitivities, PPVs and NPVs were not significantly different (p = 0.06, 0.36, 0.17). Amongst studies utilising diffusion-weighted imaging with highest b-value of ≥1400 s/mm2, pooled sensitivities, specificities, PPVs and NPVs were not significantly different (p = 0.52, 0.4, 0.5, 0.47). There were no significant differences in pooled sensitivities, specificities, PPVs and NPVs between PI-RADS v. 2.1 and PI-RADS v. 2 for less-experienced readers (p = 0.65, 0.37, 0.65, 0.81) and for more experienced readers (p = 0.57, 0.90, 0.91, 0.65). For PI-RADS v. 2.1 alone, there were no significant differences in pooled sensitivity, specificity, PPV and NPV between less and more experienced readers (p = 0.38, 0.70, 1, 0.48). Inter-reader agreement was moderate to substantial for both PI-RADS v. 2.1 and v. 2. There were no significant differences between pooled csPCa rates between PI-RADS v. 2.1 and v. 2 for PI-RADS 1–2 lesions (6.6% vs 7.3%, p = 0.53), or PI-RADS 3 lesions (24.1% vs 26.8%, p = 0.28). Conclusions: Diagnostic performance and inter-reader agreement for PI-RADS v. 2.1 is comparable to PI-RADS v. 2, however the significantly lower specificity of PI-RADS v. 2.1 may result in increased number of unnecessary biopsies. Advances in knowledge: 1. Compared to PI-RADS v. 2, PI-RADS v. 2.1 has a non-significantly higher sensitivity but a significantly lower specificity for detection of clinically significant prostate cancer. 2. PI-RADS v. 2.1 could potentially result in considerable increase in number of negative targeted biopsy rates for PI-RADS 3 lesions, which could have been potentially avoided.
- 1 August 2020
- Published by Elsevier in Urologic Oncology: Seminars and Original Investigations
- Vol. 38 (8) , 650-660
A systematic review and meta-analysis of magnetic resonance imaging and ultrasound guided fusion biopsy of prostate for cancer detection—Comparing transrectal with transperineal approaches
- 1 August 2020
- Published by Elsevier in Urologic Oncology: Seminars and Original Investigations
- Vol. 38 (8) , 650-660
A systematic review and meta-analysis of magnetic resonance imaging and ultrasound guided fusion biopsy of prostate for cancer detection—Comparing transrectal with transperineal approaches
- 25 August 2018
- Published by Springer Nature in Abdominal Radiology
- Vol. 44 (2) , 493-508
Pathological variants of hepatocellular carcinoma on MRI: emphasis on histopathologic correlation
Hepatocellular carcinoma (HCC) is a unique tumor because it is one of the few cancers which can be treated based on imaging alone. Magnetic resonance imaging (MRI) carries higher sensitivity and specificity for the diagnosis of HCC than either computed tomography (CT) or ultrasound. MRI is imaging modality of choice for the evaluation of complex liver lesions and HCC because of its inherent ability to depict cellularity, fat, and hepatocyte composition with high soft tissue contrast. The imaging features of progressed HCC are well described. However, many HCC tumors do not demonstrate classical imaging features, posing a diagnostic dilemma to radiologists. Some of these can be attributed to variations in tumor biology and histology, which result in radiological features that differ from the typical progressed HCC. This pictorial review seeks to demonstrate the appearance of different variants of HCC on MRI imaging, in relation to their histopathologic features.
- 25 August 2018
- Published by Springer Nature in Abdominal Radiology
- Vol. 44 (2) , 493-508
Pathological variants of hepatocellular carcinoma on MRI: emphasis on histopathologic correlation
Hepatocellular carcinoma (HCC) is a unique tumor because it is one of the few cancers which can be treated based on imaging alone. Magnetic resonance imaging (MRI) carries higher sensitivity and specificity for the diagnosis of HCC than either computed tomography (CT) or ultrasound. MRI is imaging modality of choice for the evaluation of complex liver lesions and HCC because of its inherent ability to depict cellularity, fat, and hepatocyte composition with high soft tissue contrast. The imaging features of progressed HCC are well described. However, many HCC tumors do not demonstrate classical imaging features, posing a diagnostic dilemma to radiologists. Some of these can be attributed to variations in tumor biology and histology, which result in radiological features that differ from the typical progressed HCC. This pictorial review seeks to demonstrate the appearance of different variants of HCC on MRI imaging, in relation to their histopathologic features.
- 1 April 2015
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (4) , W439-W448
Dynamic Contrast-Enhanced MRI for the Detection of Prostate Cancer: Meta-Analysis
OBJECTIVE. The purpose of this study was to systematically review and meta-analyze dynamic contrast-enhanced MRI (DCE-MRI) for the detection of prostate cancer in comparison with standard evaluation with T2-weighted imaging. MATERIALS AND METHODS. A PubMed electronic database search for the terms “dynamic contrast-enhanced,” “prostate,” and “MRI” was completed for articles up to September 17, 2013. All included studies had histopathologic correlation. Two by two contingency data were constructed for each study. A binormal bayesian ROC model was used to estimate and compare sensitivity, specificity, and AUC among eligible modalities. RESULTS. Both DCE-MRI (0.82–0.86) and diffusion-weighted MRI (DWI) (0.84–0.88) yielded significantly better AUC than T2-weighted imaging (0.68–0.77). Moreover, partial AUC for the combination of DCE-MRI, DWI, and T2-weighted imaging was improved significantly (0.111; 0.103–0.119) when compared with DCE-MRI alone (0.079; 0.072–0.085) and T2-weighted imaging alone (0.079; 0.074–...
- 1 April 2015
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (4) , W439-W448
Dynamic Contrast-Enhanced MRI for the Detection of Prostate Cancer: Meta-Analysis
OBJECTIVE. The purpose of this study was to systematically review and meta-analyze dynamic contrast-enhanced MRI (DCE-MRI) for the detection of prostate cancer in comparison with standard evaluation with T2-weighted imaging. MATERIALS AND METHODS. A PubMed electronic database search for the terms “dynamic contrast-enhanced,” “prostate,” and “MRI” was completed for articles up to September 17, 2013. All included studies had histopathologic correlation. Two by two contingency data were constructed for each study. A binormal bayesian ROC model was used to estimate and compare sensitivity, specificity, and AUC among eligible modalities. RESULTS. Both DCE-MRI (0.82–0.86) and diffusion-weighted MRI (DWI) (0.84–0.88) yielded significantly better AUC than T2-weighted imaging (0.68–0.77). Moreover, partial AUC for the combination of DCE-MRI, DWI, and T2-weighted imaging was improved significantly (0.111; 0.103–0.119) when compared with DCE-MRI alone (0.079; 0.072–0.085) and T2-weighted imaging alone (0.079; 0.074–...
- 18 April 2013
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 19 (4) , 312-9
MRI of gallbladder cancer
Diagnostic and Interventional Radiology
- 18 April 2013
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 19 (4) , 312-9
MRI of gallbladder cancer
Diagnostic and Interventional Radiology
- 1 June 2012
- Published by SAGE Publications in Acta Radiologica
- Vol. 53 (5) , 494-500
The varying faces of gall bladder carcinoma: pictorial essay
The objective of this review is to highlight the pertinent imaging features and potential pitfalls in the diagnosis and staging of gall bladder carcinoma. This condition is notoriously non-specific on imaging on many occasions, particularly in its early stages; gall bladder carcinoma shows numerous features that overlap with a large number of benign conditions, leading to delayed diagnosis and incurable disease. Radiologists should be familiar with its typical and atypical imaging features.
- 1 June 2012
- Published by SAGE Publications in Acta Radiologica
- Vol. 53 (5) , 494-500
The varying faces of gall bladder carcinoma: pictorial essay
The objective of this review is to highlight the pertinent imaging features and potential pitfalls in the diagnosis and staging of gall bladder carcinoma. This condition is notoriously non-specific on imaging on many occasions, particularly in its early stages; gall bladder carcinoma shows numerous features that overlap with a large number of benign conditions, leading to delayed diagnosis and incurable disease. Radiologists should be familiar with its typical and atypical imaging features.
- 1 August 2011
- Published by Wolters Kluwer Health in American Journal of Clinical Oncology
- Vol. 34 (4) , 411-416
Multidetector Computed Tomography Follow-up of Hypoattenuating Small Liver Lesions in Patients With Rectal Cancer
Objective: To study the behavior of hypoattenuating liver lesions, deemed too small to characterize at baseline scanning with multidetector computed tomography (CT), in patients with rectal cancer. Methods: Retrospective review of locally advanced rectal cancer patients from a radiation oncology therapy database was conducted. Patients who presented before neoadjuvant chemoradiation without metastases at baseline CT and with follow-up scans for at least 1 year after therapy were evaluated. CT studies were reviewed for the presence and change in size of hypoattenuating liver lesions (P = 0.41) and N-stage (P > 0.99). Conclusion: In patients with rectal cancer, majority of small hypoattenuating liver lesions remain stable and are treated as benign lesions, at multidetector CT follow-up of more than a year. Nevertheless, hepatic lesion stability during systemic therapy should still be interpreted with caution and closely followed for at least 1 year after completion of therapy.
- 1 August 2011
- Published by Wolters Kluwer Health in American Journal of Clinical Oncology
- Vol. 34 (4) , 411-416
Multidetector Computed Tomography Follow-up of Hypoattenuating Small Liver Lesions in Patients With Rectal Cancer
Objective: To study the behavior of hypoattenuating liver lesions, deemed too small to characterize at baseline scanning with multidetector computed tomography (CT), in patients with rectal cancer. Methods: Retrospective review of locally advanced rectal cancer patients from a radiation oncology therapy database was conducted. Patients who presented before neoadjuvant chemoradiation without metastases at baseline CT and with follow-up scans for at least 1 year after therapy were evaluated. CT studies were reviewed for the presence and change in size of hypoattenuating liver lesions (P = 0.41) and N-stage (P > 0.99). Conclusion: In patients with rectal cancer, majority of small hypoattenuating liver lesions remain stable and are treated as benign lesions, at multidetector CT follow-up of more than a year. Nevertheless, hepatic lesion stability during systemic therapy should still be interpreted with caution and closely followed for at least 1 year after completion of therapy.
- 1 January 2011
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 31 (1) , 117-133
Pathways of Extrapelvic Spread of Pelvic Disease: Imaging Findings
The complex extraperitoneal anatomy of the pelvis includes various outlets for the transit of organs and neurovascular structures to the rest of the body. These outlets include the greater sciatic foramen, lesser sciatic foramen, inguinal canal, femoral triangle, obturator canal, anal and genitourinary hiatuses of the pelvic floor, prevesical space, and iliopsoas compartment. All of these structures serve as conduits for the dissemination of malignant and benign inflammatory diseases from the pelvic cavity and into the soft-tissue structures of the abdominal wall, buttocks, and upper thigh. Knowledge of the pelvic anatomy is crucial to understand these patterns of disease spread. Cross-sectional imaging provides important anatomic information and depicts the extent of disease and its involvement of surrounding extrapelvic structures, information that is important for planning surgery and radiation therapy.
- 1 January 2011
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 31 (1) , 117-133
Pathways of Extrapelvic Spread of Pelvic Disease: Imaging Findings
The complex extraperitoneal anatomy of the pelvis includes various outlets for the transit of organs and neurovascular structures to the rest of the body. These outlets include the greater sciatic foramen, lesser sciatic foramen, inguinal canal, femoral triangle, obturator canal, anal and genitourinary hiatuses of the pelvic floor, prevesical space, and iliopsoas compartment. All of these structures serve as conduits for the dissemination of malignant and benign inflammatory diseases from the pelvic cavity and into the soft-tissue structures of the abdominal wall, buttocks, and upper thigh. Knowledge of the pelvic anatomy is crucial to understand these patterns of disease spread. Cross-sectional imaging provides important anatomic information and depicts the extent of disease and its involvement of surrounding extrapelvic structures, information that is important for planning surgery and radiation therapy.
- Open Access
- 1 January 2011
- Published by E-MED LTD in Cancer Imaging
- Vol. 11 (1) , 9-15
Imaging features of hematogenous metastases to the pancreas: pictorial essay
Review: Imaging features of hematogenous metastases to the pancreas: pictorial essay - Cancer Imaging Review: Imaging features of hematogenous metastases to the pancreas: pictorial essay - This pictorial essay illustrates the imaging appearances of a wide variety of metastases to the pancreas as seen on computed tomography (CT), magnetic resonance imaging and positron emission tomography/CT. Key clinical and radiologic features (lesion distribution, non-contrast imaging appearance, enhancement pattern and pattern of spread) that may aid differentiation of primary from solitary secondary pancreatic malignancies are discussed.
- 1 January 2011
- Published by E-MED LTD in Cancer Imaging
- Vol. 11 (1) , 9-15
Open AccessImaging features of hematogenous metastases to the pancreas: pictorial essay
Review: Imaging features of hematogenous metastases to the pancreas: pictorial essay - Cancer Imaging Review: Imaging features of hematogenous metastases to the pancreas: pictorial essay - This pictorial essay illustrates the imaging appearances of a wide variety of metastases to the pancreas as seen on computed tomography (CT), magnetic resonance imaging and positron emission tomography/CT. Key clinical and radiologic features (lesion distribution, non-contrast imaging appearance, enhancement pattern and pattern of spread) that may aid differentiation of primary from solitary secondary pancreatic malignancies are discussed.
- Open Access
- 1 January 2011
- Published by Hindawi Limited in International Journal of Hepatology
- Vol. 2011, 1-11
APASL and AASLD Consensus Guidelines on Imaging Diagnosis of Hepatocellular Carcinoma: A Review
Consensus guidelines for radiological diagnosis of hepatocellular carcinoma (HCC) have been drafted by several large international working groups. This article reviews the similarities and differences between the most recent guidelines proposed by the American Association for Study of Liver Diseases and the Asian Pacific Association for the Study of the Liver. Current evidence for the various imaging modalities for diagnosis of HCC and their relevance to the consensus guidelines are reviewed.
- 1 January 2011
- Published by Hindawi Limited in International Journal of Hepatology
- Vol. 2011, 1-11
Open AccessAPASL and AASLD Consensus Guidelines on Imaging Diagnosis of Hepatocellular Carcinoma: A Review
Consensus guidelines for radiological diagnosis of hepatocellular carcinoma (HCC) have been drafted by several large international working groups. This article reviews the similarities and differences between the most recent guidelines proposed by the American Association for Study of Liver Diseases and the Asian Pacific Association for the Study of the Liver. Current evidence for the various imaging modalities for diagnosis of HCC and their relevance to the consensus guidelines are reviewed.